The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index; 4 of the 5 sources its claims cite were checked for support.
Engineering a living cardiac pump on a chip using high-precision fabrication
Open accessAbstract
Biomimetic on-chip tissue models serve as a powerful tool for studying human physiology and developing therapeutics; however, their modeling power is hindered by our inability to develop highly ordered functional structures in small length scales. Here, we demonstrate how high-precision fabrication can enable scaled-down modeling of organ-level cardiac mechanical function. We use two-photon direct laser writing (TPDLW) to fabricate a nanoscale-resolution metamaterial scaffold with fine-tuned mechanical properties to support the formation and cyclic contraction of a miniaturized, induced pluripotent stem cell-derived ventricular chamber. Furthermore, we fabricate microfluidic valves with extreme sensitivity to rectify the flow generated by the ventricular chamber. The integrated microfluidic system recapitulates the ventricular fluidic function and exhibits a complete pressure-volume loop with isovolumetric phases. Together, our results demonstrate a previously unexplored application of high-precision fabrication that can be generalized to expand the accessible spectrum of organ-on-a-chip models toward structurally and biomechanically sophisticated tissue systems.
Overview
CoChat Summary
## TL;DR
The paper shows that two-photon direct laser writing can be used to build a miniaturized cardiac pump-on-a-chip with a living hiPSC-derived ventricular chamber, functional microvalves, and an afterload element. The integrated device generated unidirectional flow and a complete pressure-volume loop with isovolumetric phases, recapitulating key ventricular mechanics on a small scale.
## Key findings
- The chamber scaffold’s axial stiffness was tunable by helix thickness: increasing helix thickness from 8.3 ± 0.2 μm to 10.1 ± 0.3 μm increased stiffness from 41.7 ± 1.9 N/m to 71.3 ± 1.5 N/m.
- The helical chamber produced flow with a ~280 nl/s peak flow rate, ~65 nl stroke volume, and ~9.6% ejection fraction; chamber pressure varied from −1.4 Pa to 1.5 Pa.
- The selected suspension valve increased microfluidic resistance by two orders of magnitude in the closed state, switched states at 0.25 ± 0.06 Pa (open) and 0.11 ± 0.03 Pa (closed), and had rectification ratio > 0.80 ± 0.02 below 2 Hz.
- With valves and flow constrictor, the system produced net volume displacement of about ~4.14% ejection fraction and a complete PV loop; with a 70 μm constrictor, afterload rose to 28.6 ± 1.7 Pa from 13.1 ± 1.5 Pa with a 90 μm constrictor.
## Methods
- Design: The authors used two-photon direct laser writing (TPDLW) to fabricate a miniaturized helical scaffold for a cardiac chamber, suspension valves for flow rectification, and flow constrictors for afterload control, all integrated into a PDMS microfluidic device.
- Sample/data: The chamber was seeded with 170,000 hiPSC-CMs and 4,000 hMSCs per device; hiPSC-CMs were derived from the Harvard Personal Genome Project line 1 (GM23338; PGP1). Reported functional data came from representative devices, with similar traces from multiple experiments (n ≥ 3).
- Main analysis: Flow was quantified by particle image velocimetry on fluorescent bead videos, and pressure was estimated using finite element modeling (COMSOL) and hydraulic resistance calculations; valve sensitivity, resistance, and rectification were measured under controlled pressure/flow conditions.
## Limitations
- The paper states that the scaffold’s stiffness had “slight strain softening” and does not mimic the strain stiffening of native contracting myocardium.
- The authors explicitly note that further investigation is required to understand the system’s electrophysiological characteristics.
- Evident from the text: the paper mainly reports representative device traces and functional proof-of-concept rather than a large-scale quantitative study of robustness across many devices.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
2 Valid · 2 Not valid · 1 Not checked · 49 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“Similarly, the PV loops were characterized by two distinct filling and ejection phases that are separated by rapid vertical isovolumetric phases (Fig. 4G), as it is observed in the classic PV loop of the native ventricle (15).”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
What the sources say
- Supportedcites [15] M. B. Bastos, D. Burkhoff, J. Maly, J. Daemen, C. A. den Uil, K. Ameloot, M. Lenzen, F. Mahfoud, F. Zijlstra, J. J. Schreuder, N. M. Van Mieghem, Invasive left ventricle pressure–volume analysis: Overview and practical clinical implications. Eur. Heart J. 41, 1286– 1297 (2020). 31435675 PMC7084193 source
The General considerations section describes the ideal left-ventricular PV loop as rectangular or trapezoidal, with isovolumetric contraction, ejection, isovolumetric relaxation, and passive filling as its four phases (Figure 2A). This supports the comparison to a classic ventricular loop with filling and ejection separated by isovolumetric phases; the passage does not explicitly call those phases rapid. (LLM, conf=0.88)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Furthermore, we fabricate microfluidic valves with extreme sensitivity to rectify the flow generated by the ventricular chamber.”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: unclear — It is unclear why the paper says it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“for example, increasing from 41.7 ± 1.9 to 71.3 ± 1.5 N/m when the thickness increased from 8.3 ± 0.2 to 10.1 ± 0.3 μm (fig. S4 and table S1).”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“helical chambers were embedded in the miniPUMP device, generating bidirectional flow in the device’s channels (Fig. 2A)”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We found that only the suspension valve (Fig. 3, E and F), which was inspired after a ball check valve and consisted of a free-floating plate drifting between the open and the closed state (Fig. 3, G and H), could be fabricated to reliably rectify flow efficiently at low pressures and flow rates.”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 54 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 24
- Probably not a substantial claim. 11
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This has driven a trend toward miniaturization in OOC systems, enabling reduced cell input without sacrificing essential functionality (Michas et al., 2022).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The miniaturized approach described by Michas et al. is currently the most cell-efficient (with 174,000 cells per ECC), representing a cost-saving strategy that aligns well with the broader OOC trend toward minimizing input material while retaining essential functionality (Michas et al., 2022).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Several ECCs are derived from human induced Pluripotent Stem Cells (hiPSCs), commonly differentiated into CMs and FBs (Li et al., 2018; Michas et al., 2022; Kuckelkorn et al., 2025; Ribeiro et al., 2025).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Incorporation of valves is critical for reproducing physiologic PV loops and ensuring unidirectional flow (MacQueen et al., 2018; Michas et al., 2022).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
The cited source says what the claim attributes to it.
In the citing paper
“In contrast, Michas et al. and Macqueen et al. successfully incorporated valves into microfluidic and bioreactor platforms, respectively, with Michas et al. demonstrating unidirectional flow and MacQueen et al. reporting improved PV loop morphology as a result of valve presence (Michas et al., 2022; MacQueen et al., 2018).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Organogenesis in a dish: Modeling development and disease using organoid technologies
Lancaster, M. A., & Knoblich, J. A. (2014) · Science · doi:10.1126/science.1247125 · Cited by 2,931 · cited 1×
“The development of such models can be attributed to progress in induced pluripotent stem cell (iPSC) technology (3), as well as innovative methods to assemble cells into aggregates and functional structures, from organoids (4) to different types of three-dimensional (3D) organ-on-chip models (5).”
BackgroundWarren, L., Manos, P. D., Ahfeldt, T., Loh, Y.-H., Li, H., Lau, F., Ebina, W., Mandal, P. K., Smith, Z. D., Meissner, A., et al. (2010) · Cell Stem Cell · doi:10.1016/j.stem.2010.08.012 · Cited by 2,662
Three-dimensional microfabrication with two-photon-absorbed photopolymerization
Maruo, S., Nakamura, O., & Kawata, S. (1997) · Optics Letters · doi:10.1364/ol.22.000132 · Cited by 1,952 · cited 11×
“Here, we harness the high precision of TPDLW to implement a miniaturized metamaterial scaffold that supports the anisotropic contraction of an in vitro cardiac ventricle, as well as functional miniaturized valves featuring sufficient sensitivity to respond to the cardiac chamber’s flow.”
MethodInfluentialInduced pluripotent stem cell technology: a decade of progress.
Shi, Y., Inoue, H., Wu, J. C., & Yamanaka, S. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.245 · Cited by 1,525 · cited 1×
“The development of such models can be attributed to progress in induced pluripotent stem cell (iPSC) technology (3), as well as innovative methods to assemble cells into aggregates and functional structures, from organoids (4) to different types of three-dimensional (3D) organ-on-chip models (5).”
BackgroundFunctional Cardiomyocytes Derived From Human Induced Pluripotent Stem Cells
Zhang, J., Wilson, G. F., Soerens, A. G., Koonce, C. H., Yu, J., Palecek, S. P., Thomson, J. A., & Kamp, T. J. (2009) · Circulation Research · doi:10.1161/circresaha.108.192237 · Cited by 1,407
Multivascular networks and functional intravascular topologies within biocompatible hydrogels
Grigoryan, B., Paulsen, S. J., Corbett, D. C., Sazer, D. W., Fortin, C. L., Zaita, A. J., Greenfield, P. T., Calafat, N. J., Gounley, J. P., Ta, A. H., et al. (2019) · Science · doi:10.1126/science.aav9750 · Cited by 1,396
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Progress and potential in organoid research
Rossi, G., Manfrin, A., & Lutolf, M. P. (2018) · Nature Reviews Genetics · doi:10.1038/s41576-018-0051-9 · Cited by 1,182
Kadic, M., Milton, G. W., van Hecke, M., & Wegener, M. (2019) · Nature Reviews Physics · doi:10.1038/s42254-018-0018-y · Cited by 1,106
Sustained in vitro intestinal epithelial culture within a Wnt-dependent stem cell niche
Ootani, A., Li, X., Sangiorgi, E., Ho, Q. T., Ueno, H., Toda, S., Sugihara, H., Fujimoto, K., Weissman, I. L., Capecchi, M. R., et al. (2009) · Nature Medicine · doi:10.1038/nm.1951 · Cited by 906
Cited by
Induced pluripotent stem cells (iPSCs): molecular mechanisms of induction and applications
Cerneckis, J., Cai, H., & Shi, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01809-0 · Cited by 452
Challenges and opportunities for the next generation of cardiovascular tissue engineering
Cho, S., Discher, D. E., Leong, K. W., Vunjak-Novakovic, G., & Wu, J. C. (2022) · Nature Methods · doi:10.1038/s41592-022-01591-3 · Cited by 176
Shiwarski, D. J., Hudson, A. R., Tashman, J. W., Bakırcı, E., Moss, S., Coffin, B. D., & Feinberg, A. W. (2025) · Science Advances · doi:10.1126/sciadv.adu5905 · Cited by 146
Lee, S. J., Jeong, W., & Atala, A. (2024) · Advanced Materials · doi:10.1002/adma.202408032 · Cited by 116
From Organ-on-a-Chip to Human-on-a-Chip: A Review of Research Progress and Latest Applications
Huang, Y., Liu, T., Huang, Q., & Wang, Y. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00004 · Cited by 109
Microfluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
“A miniaturized cardiac scaffold can mimic the formation and cyclic contraction of a ventricular chamber 118 .”
Criscione, J. D., Rezaei, Z., Cantu, C. M. H., Murphy, S. A., Shin, S. R., & Kim, D. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114840 · Cited by 87
Advances in Microfluidics: Technical Innovations and Applications in Diagnostics and Therapeutics
Aubry, G., Lee, H. J., & Lu, H. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c04562 · Cited by 75
Recent Advances of Auxetic Metamaterials in Smart Materials and Structural Systems
Zhang, Y., Jiang, W., Jiang, W., Zhang, X. Y., Dong, J., Xie, Y. M., Evans, K. E., & Ren, X. Y. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202421746 · Cited by 152
Next-Generation Microfluidics for Biomedical Research and Healthcare Applications
Deliorman, M., Ali, D. S., & Qasaimeh, M. A. (2023) · Biomedical Engineering and Computational Biology · doi:10.1177/11795972231214387 · Cited by 64
“Zhu et al 29 4 with permission from American Association for the Advancement of Science (a), from Bhuiyan et al, 5 with permission from American Chemical Society (b), from Li et al, 6 with permission from American Institute of Physics Publishing (c), and from Michas et al, 7 with permission from American Association f…”
BackgroundDirect laser writing-enabled 3D printing strategies for microfluidic applications
Young, O. M., Xu, X., Sarker, S., & Sochol, R. D. (2024) · Lab on a Chip · doi:10.1039/d3lc00743j · Cited by 67
Round-robin testing of commercial two-photon polymerization 3D printers
Cantoni, F., Maher, D., Bosler, E., Kühne, S., Barbe, L., Oberschmidt, D., Marquette, C. A., Taboryski, R., Tenje, M., & Bunea, A. (2023) · Additive manufacturing · doi:10.1016/j.addma.2023.103761 · Cited by 41
Blueprints of Architected Materials: A Guide to Metamaterial Design for Tissue Engineering
Kalogeropoulou, M., Kracher, A., Fucile, P., Mihaila, S. M., & Moroni, L. (2024) · Advanced Materials · doi:10.1002/adma.202408082 · Cited by 48
Micro/Nanorobots for Advanced Light‐Based Biosensing and Imaging
Neettiyath, A., & Pumera, M. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202415875 · Cited by 44
Zhang, F., Cheng, H., Qu, K.-Y., Qian, X., Lin, Y., Zhang, Y., Qian, S.-C., Huang, N., Cui, C., & Chen, M. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100626 · Cited by 53
“The heart-on-chip technologies are intended to faithfully reproduce the complicated native cardiac tissue by supplying biochemical and biophysical signals [7,8].”
BackgroundEngineering Cardiac Tissue for Advanced Heart‐On‐A‐Chip Platforms
Chen, X., Liu, S., Han, M., Long, M., Li, T., Hu, L., Wang, L., Huang, W., & Wu, Y. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202301338 · Cited by 38
Revolutionizing the female reproductive system research using microfluidic chip platform
Yan, J., Wu, T., Zhang, J., Gao, Y., Wu, J., & Wang, S. (2023) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-02258-7 · Cited by 36
“Over the past decade, several organs-on-chips for tissue or organ models have been developed, such as for the lung [54–61], kidney [62–66], intestine [67–71], liver [72–77], heart [78– 81], blood vessel [82–87], skin [88–91].”
BackgroundJuguilon, C., Khosravi, R., Radisic, M., & Wu, J. C. (2025) · Circulation Research · doi:10.1161/circresaha.125.325497 · Cited by 47
Mechanical Metamaterials for Bioengineering: In Vitro, Wearable, and Implantable Applications
Kazim, M., Pal, A., & Goswami, D. (2025) · Advanced Engineering Materials · doi:10.1002/adem.202401806 · Cited by 34
Microscale 3D Printing and Tuning of Cellulose Nanocrystals Reinforced Polymer Nanocomposites
Groetsch, A., Stelzl, S., Nagel, Y., Kochetkova, T., Scherrer, N. C., Ovsianikov, A., Michler, J., Pethő, L., Siqueira, G. D. F., Nyström, G., et al. (2022) · Small · doi:10.1002/smll.202202470 · Cited by 28
Moore, J., Ewoldt, J. K., Venturini, G., Pereira, A. C., Padilha, K., Lawton, M. L., Lin, W., Goel, R. K., Luptak, I., Perissi, V., et al. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24054724 · Cited by 29
Self-citationKim, M. S., Choi, Y., & Lee, K. Y. (2025) · Polymers · doi:10.3390/polym17172337 · Cited by 39
“Such innovations underscore the remarkable potential of TPP and TPDLW in recreating the biomechanical complexity, structural fidelity, and functional integration required for advanced cardiovascular organ-on-chip systems (Figure 7a) [32].”
Wu, H., Shi, S., Liu, Y., Zhang, Q., Lam, R. H. W., Lim, C. T., & Hu, J. (2023) · Biofabrication · doi:10.1088/1758-5090/acdaf9 · Cited by 29
Dutta, S. D., Ganguly, K., Randhawa, A., Patil, T. V., Kim, H., Acharya, R., & Lim, K. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301874 · Cited by 24
Zhang, Y., Yu, H., Zhang, X., Zheng, J., Wang, J., Guo, H., Qiu, Y., Wang, X., Liu, L., & Li, W. J. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202313922 · Cited by 21
Hydraulic–electric analogy for design and operation of microfluidic systems
Li, Z., Liu, C., & Sun, J. (2023) · Lab on a Chip · doi:10.1039/d3lc00265a · Cited by 24
Multifactorial approaches to enhance maturation of human iPSC-derived cardiomyocytes
Kistamás, K., Müller, A., Muenthaisong, S., Lamberto, F., Zana, M., Dulac, M., Leal, F., Maziz, A., Costa, P. F., Bernotienė, E., et al. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.122668 · Cited by 17
Biohybrid Soft Robots Powered by Myocyte: Current Progress and Future Perspectives
Yuan, Z., Guo, Q., Jin, D., Zhang, P., & Yang, W. (2023) · Micromachines · doi:10.3390/mi14081643 · Cited by 24
“Reproduced from Reference [16] with Figure 7.”
BackgroundMethodInfluentialMultiorifice acoustic microrobot for boundary-free multimodal 3D swimming
Mahkam, N., Ugurlu, M. C., Kalva, S. K., Aghakhani, A., Razansky, D., & Sitti, M. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2417111122 · Cited by 17
“The microrobots are fabricated using a two - photon polymerization - based 3D micro printing technique with a resolution down to 100 nm and bio compatible resins (39, 57–59), as shown in Fig.”
Xu, N., Lin, H., Lin, J., Cheng, J., Wang, P., & Lin, L. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c03892 · Cited by 15
Jin, G., Kim, D., Mun, S., & Bang, S. (2024) · BioChip Journal · doi:10.1007/s13206-024-00141-7 · Cited by 16
The Art of Building Living Tissues: Exploring the Frontiers of Biofabrication with 3D Bioprinting
Verma, S., Khanna, V., Kumar, S., & Kumar, S. (2023) · ACS Omega · doi:10.1021/acsomega.3c02600 · Cited by 14
Nanoscale printed tunable specimen geometry enables high-throughput miniaturized fracture testing
Jelinek, A., Žák, S., Cordill, M. J., Kiener, D., & Alfreider, M. (2023) · Materials & Design · doi:10.1016/j.matdes.2023.112329 · Cited by 13
Ahmed, D. W., Eiken, M. K., DePalma, S. J., Helms, A. S., Zemans, R. L., Spence, J. R., Baker, B. M., & Loebel, C. (2023) · iScience · doi:10.1016/j.isci.2023.108472 · Cited by 11
Bioprinting approaches in cardiac tissue engineering to reproduce blood-pumping heart function
Kim, M. J., Hwang, D. G., & Jang, J. (2024) · iScience · doi:10.1016/j.isci.2024.111664 · Cited by 22
“14 Therefore, research has increasingly focused on fabricating engineered heart valves (EHVs) and reca-pitulating the heart valve functions.”
3D-Microprinted PDMS-Based Microfluidic Vessels for Organ-on-a-Chip Applications
Xu, X., Chen, C., Wen, Z., Young, O. M., Felix, B. M., Bandyopadhyay, B. C., Bentley, W. E., & Sochol, R. D. (2024) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems58180.2024.10439438 · Cited by 10
“To enable such capabilities for OOC systems, the additive micro/nano-manufacturing approach, DLW, is uniquely suited [14-16].”
MethodSelf-citationIntegrating Hierarchical Vasculature into Engineered Cardiac Tissues
Zhuang, R. Z., Chesnais, F., & Vunjak‐Novakovic, G. (2025) · Advanced Materials · doi:10.1002/adma.202509242 · Cited by 11
Garmroudi, A., Tushar, M. A. K., Liu, C., & Li, Z. (2025) · npj Robotics · doi:10.1038/s44182-025-00056-x · Cited by 13
“5D-i) 75 .”
Organoid bioprinting to pattern the matrix microenvironment
Zhang, D. H., Huerta-López, C., & Heilshorn, S. C. (2025) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2025.100607 · Cited by 14
Heart-on-a-chip and vasculature-on-a-chip platforms as models of cardiovascular disease
Khosravi, R., & Radisic, M. (2026) · Nature Reviews Cardiology · doi:10.1038/s41569-026-01255-1 · Cited by 18
“…infraphysiological conditions that are representative of disease states, help to predict fluid flow characteristics in microfluidic channels and microvascular networks 112 , and generate pressure–volume loops to determine intraventricular pressure and ejection fraction in ventricular models 113 .”
InfluentialDhand, A. P., Juarros, M. A., Martin, T. G., Rodriguez‐Rivera, G. J., Hunt, D. R., Obenreder, M. C., Crosby, C. O., Meurer-Zeman, B., Mcafee, Q. W., Valle-Ayala, H., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.10.01.616163 · Cited by 7
Meiers, D. T., Rothammer, M., Maier, M., Zollfrank, C., & von Freymann, G. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202201688 · Cited by 7
Geometry and length control of 3D engineered heart tissues using direct laser writing
Karakan, M. Ç., Ewoldt, J. K., Segarra, A. J., Sundaram, S., Wang, M. C., White, A. E., Chen, C. S., & Ekinci, K. L. (2024) · Lab on a Chip · doi:10.1039/d3lc00752a · Cited by 7
Self-citationAdvancing Cardiac Organoid Engineering Through Application of Biophysical Forces
Blazeski, A., García‐Cardeña, G., & Kamm, R. D. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3514378 · Cited by 8
“Although CMs have been used to create a biophysical pump that can drive flow through fabricated conduits [192], organoids in multi-organ models have not yet been used as actuators coupled to the circulation.”
Yang, C., Zhang, Z., Fan, X., Liu, Y., Deng, C., Zhang, M., Wang, X., Deng, L., Gao, H., Deng, Y., et al. (2025) · Nano Letters · doi:10.1021/acs.nanolett.5c00346 · Cited by 6
Multiphoton Polymerization-Based Micro/Nanomanufacturing Toward Precision Medicine
Hu, J., Ren, A., Lv, W., Aazmi, A., Qin, C., Liang, X., Xu, X., Yu, M., Li, Q., Yang, H., et al. (2024) · Engineering · doi:10.1016/j.eng.2024.10.016 · Cited by 7
Understanding the Lymphatic System: Tissue-on-Chip Modeling
Polacheck, W. J., Dixon, J. B., & Aw, W. Y. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110222-100246 · Cited by 9
Bridging high resolution sub-cellular imaging with physiologically relevant engineered tissues
Kooh, Y. K. G., & Huebsch, N. (2024) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2024.1481933 · Cited by 7
Advancing Engineered Heart Muscle Tissue Complexity with Hydrogel Composites
Dickerson, D. A. (2022) · Advanced Biology · doi:10.1002/adbi.202200067 · Cited by 6
3D Bioprinting of Collagen-based Microfluidics for Engineering Fully-biologic Tissue SystemsPreprint
Shiwarski, D. J., Hudson, A. R., Tashman, J. W., Bakırcı, E., Moss, S., Coffin, B. D., & Feinberg, A. W. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.01.26.577422 · Cited by 5
Cano-Jorge, M., Gómez, S., den Toonder, J. M. J., Wang, Y., & Passier, R. C. (2025) · Cardiovascular Research · doi:10.1093/cvr/cvaf247 · Cited by 7
“43 Cardiac chamber models offer significant advantages in physiological relevance, as they simultaneously facilitate modulation of multiaxial preload and adjustable afterload while providing haemodynamic readouts.”
Biodegradable and Biohybrid Materials for Next-Generation Brain-Computer Interfaces
Seyedkhani, S. A. (2024) · Artificial intelligence · doi:10.5772/intechopen.115156 · Cited by 4
Biofabrication strategies for cardiac tissue engineering
Okhovatian, S., Khosravi, R., Wang, E. Y., Zhao, Y., & Radisic, M. (2024) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2024.103166 · Cited by 6
Electrochemically Responsive 3D Nanoarchitectures
(2023) · doi:10.1002/adma.202304517 · Cited by 3
Guo, X., Sun, L., Xu, D., & Zhao, Y. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.158261 · Cited by 4
Targeting Epigenetics in Pulmonary Arterial Hypertension
Rahman, K. M. T., Islam, T., Islam, M. F., Carbone, R. G., Butzin, N. C., & Ali, M. K. (2023) · Springer eBooks · doi:10.1007/978-981-99-4780-5_14 · Cited by 2
Kong, M., Wu, Z., Zheng, Z., Zhang, B., Zeng, Y., Deng, H., Feng, D., Zhang, W., Li, C., Fu, X., et al. (2025) · Interdisciplinary medicine · doi:10.1002/inmd.20240085 · Cited by 8
Digital light processing 3D printing enables versatile fabrication of human engineered heart tissues
Dhand, A. P., Juarros, M. A., Martin, T. G., Garay‐Sarmiento, M., Alamana, C., Hunt, D. R., Rodriguez‐Rivera, G. J., Obenreder, M. C., Crosby, C. O., Meurer-Zeman, B., et al. (2026) · Cell Biomaterials · doi:10.1016/j.celbio.2026.100405 · Cited by 9
Kuckelkorn, C., Aksoy, E., Stojanovic, N., Oulahyane, L., Ritter, M., Pfannkuche, K., & Fischer, H. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202403897 · Cited by 3
A human engineered mini-heart platform for mimicking ventricular pump function
Ribeiro, M. C., Cano-Jorge, M., ten Den, S., Snippert, D., Karperien, M., Kamperman, T., Lajoinie, G., Versluis, M., & Passier, R. (2025) · bioRxiv · doi:10.1101/2025.08.25.672056 · Cited by 1
“(Kupfer et al., 2020; R. A. Li et al., 2018; Macqueen et al., 2018; Michas et al., 2022).”
Medical applications of additive manufacturing
(2024) · doi:10.1016/b978-0-443-18462-8.00015-5 · Cited by 1
Recent advances in biological pumps as a building block for bioartificial hearts
Brimmer, S., Ji, P., Birla, A. K., Keswani, S. G., Caldarone, C. A., & Birla, R. K. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1061622 · Cited by 1
“As the field of biological pumps has progressed, more recent efforts have focused on the use of micro-fluidics to develop “on-thechip” models of these pumps (Michas et al., 2022).”
BackgroundTowards advanced regenerative therapeutics to tackle cardio-cerebrovascular diseases
Chen, X., Lin, W., & Tortorella, M. D. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100520 · Cited by 1
“An integrated microfluidic system with high-precision fabrication has been successfully generalized to expand the accessible spectrum of organ-on-a-chip models towards structurally and biomechanically sophisticated tissue systems [160].”
Human iPSC-Based in Vitro Cardiovascular Tissue Models for Drug Screening Applications
Anand, S., Chen, G., Khanna, A., & Huang, N. F. (2025) · Current Cardiology Reports · doi:10.1007/s11886-025-02284-x · Cited by 1
“Two-photon micro-printing has also been used to create a miniature ventricular pump whose cell-driven pressure-volume loops mimic those of a native heart [72].”
Li, H., Wang, X., Song, Y., Hu, X., & Yao, J. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.26.728005
Stroke volume analog on a chip – in vitro hydrodynamic model of cardiac pumping efficiency
Zimmerman, J. F., MacQueen, L. A., Henze, D. E., Drennan, D. J., Kim, S. L., Ardoña, H. A. M., Choi, S., Jin, Q., & Parker, K. K. (2026) · Lab on a Chip · doi:10.1039/d5lc00547g
Liu, K., Shanmugasundaram, A., Sun, H., Li, L., Jeong, G., Ko, S. Y., Kim, E., Lee, B., & Shanmugasundaram, A. (2026) · ACS Sensors · doi:10.1021/acssensors.6c01331
“Numerous microfluidic valves have been presented including fluidic analogs to many logic devices [5], [29], novel manufacturing techniques [30], [31], [32] and specialized applications [33], [34].”
BackgroundMicrofluidic Pumping of Artificial Microcilia Via Asymmetric Beating of Cardiomyocytes
Cao, Z., Liu, Y., Sai, H., Tang, Y., Lv, P., Huang, J., Duan, H., & Huang, T. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202517931
From Bioinspired Topographies toward Non-Wettable Neural Implants
Sharbatian, A., Devkota, K., Vajari, D. A., & Stieglitz, T. (2023) · Micromachines · doi:10.3390/mi14101846
“IP-S is a non-cytotoxic resin formulation that has been reported in several publications to be suitable for biological applications [33–37].”
BackgroundDefining the parameter space for construction of cardiac ventricle models
Okhovatian, S., & Radisic, M. (2025) · Biophysics Reviews · doi:10.1063/5.0272634
Hecking, J., Cano-Jorge, M., Passier, R., & Rivera-Arbeláez, J. M. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1719533
Approaches for recapitulating the extracellular matrix in organs-on-chip
Singletary, M. W., Stack, R. N., Garcia, M., Schmoyer, S., Elayaperumal, S., & Polacheck, W. J. (2026) · Cell Biomaterials · doi:10.1016/j.celbio.2026.100577
Lim, D., Zhang, J., Lin, H., Xu, T., Li, Y., Zhang, Z., Hicks, S., Chudinov, I., Nechipurenko, D., Gardiner, E. E., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.17.496569 · Cited by 1
Metadata
- Authors
- Michas, C., Karakan, M. Ç., Nautiyal, P., Seidman, J. G., Seidman, C. E., Agarwal, A., Ekinci, K., Eyckmans, J., White, A. E., & Chen, C. S.
- Affiliations
- Boston University (US)
- Florida International University (US)
- Harvard University (US)
- Brigham and Women's Hospital (US)
- Corresponding author
- White, Alice E.
- Chen, Christopher S.
- ORCID
- Venue
- Science Advances
- Published
- 2022-04-22
- Volume
- 8
- Issue
- 16
- Pages
- eabm3791-eabm3791
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC9032966
- OpenAlex
- W4224247795
- Cited by
- 82
- References
- 33
- Citations by year
- 2026: 10 · 2025: 20 · 2024: 26 · 2023: 21 · 2022: 5
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Science Advances (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R01HL084553, R01HL080494)
- National Institute of Biomedical Imaging and Bioengineering (UH3EB025765)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- organ-on-a-chip, cardiac pump, biomimetic tissue engineering, two-photon direct laser writing, iPSC-derived cardiomyocytes, microfluidic valves, pressure-volume loops, cardiac mechanical function
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.