Engineering a living cardiac pump on a chip using high-precision fabrication
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index; 4 of the 5 sources its claims cite were checked for support.
Abstract
Biomimetic on-chip tissue models serve as a powerful tool for studying human physiology and developing therapeutics; however, their modeling power is hindered by our inability to develop highly ordered functional structures in small length scales. Here, we demonstrate how high-precision fabrication can enable scaled-down modeling of organ-level cardiac mechanical function. We use two-photon direct laser writing (TPDLW) to fabricate a nanoscale-resolution metamaterial scaffold with fine-tuned mechanical properties to support the formation and cyclic contraction of a miniaturized, induced pluripotent stem cell-derived ventricular chamber. Furthermore, we fabricate microfluidic valves with extreme sensitivity to rectify the flow generated by the ventricular chamber. The integrated microfluidic system recapitulates the ventricular fluidic function and exhibits a complete pressure-volume loop with isovolumetric phases. Together, our results demonstrate a previously unexplored application of high-precision fabrication that can be generalized to expand the accessible spectrum of organ-on-a-chip models toward structurally and biomechanically sophisticated tissue systems.
Overview
CoChat Summary
## TL;DR
The paper shows that two-photon direct laser writing can be used to build a miniaturized cardiac pump-on-a-chip with a living hiPSC-derived ventricular chamber, functional microvalves, and an afterload element. The integrated device generated unidirectional flow and a complete pressure-volume loop with isovolumetric phases, recapitulating key ventricular mechanics on a small scale.
## Key findings
- The chamber scaffold’s axial stiffness was tunable by helix thickness: increasing helix thickness from 8.3 ± 0.2 μm to 10.1 ± 0.3 μm increased stiffness from 41.7 ± 1.9 N/m to 71.3 ± 1.5 N/m.
- The helical chamber produced flow with a ~280 nl/s peak flow rate, ~65 nl stroke volume, and ~9.6% ejection fraction; chamber pressure varied from −1.4 Pa to 1.5 Pa.
- The selected suspension valve increased microfluidic resistance by two orders of magnitude in the closed state, switched states at 0.25 ± 0.06 Pa (open) and 0.11 ± 0.03 Pa (closed), and had rectification ratio > 0.80 ± 0.02 below 2 Hz.
- With valves and flow constrictor, the system produced net volume displacement of about ~4.14% ejection fraction and a complete PV loop; with a 70 μm constrictor, afterload rose to 28.6 ± 1.7 Pa from 13.1 ± 1.5 Pa with a 90 μm constrictor.
## Methods
- Design: The authors used two-photon direct laser writing (TPDLW) to fabricate a miniaturized helical scaffold for a cardiac chamber, suspension valves for flow rectification, and flow constrictors for afterload control, all integrated into a PDMS microfluidic device.
- Sample/data: The chamber was seeded with 170,000 hiPSC-CMs and 4,000 hMSCs per device; hiPSC-CMs were derived from the Harvard Personal Genome Project line 1 (GM23338; PGP1). Reported functional data came from representative devices, with similar traces from multiple experiments (n ≥ 3).
- Main analysis: Flow was quantified by particle image velocimetry on fluorescent bead videos, and pressure was estimated using finite element modeling (COMSOL) and hydraulic resistance calculations; valve sensitivity, resistance, and rectification were measured under controlled pressure/flow conditions.
## Limitations
- The paper states that the scaffold’s stiffness had “slight strain softening” and does not mimic the strain stiffening of native contracting myocardium.
- The authors explicitly note that further investigation is required to understand the system’s electrophysiological characteristics.
- Evident from the text: the paper mainly reports representative device traces and functional proof-of-concept rather than a large-scale quantitative study of robustness across many devices.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
2 Valid · 2 Not valid · 1 Not checked · 49 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“Similarly, the PV loops were characterized by two distinct filling and ejection phases that are separated by rapid vertical isovolumetric phases (Fig. 4G), as it is observed in the classic PV loop of the native ventricle (15).”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
What the sources say
- Supportedcites [15] M. B. Bastos, D. Burkhoff, J. Maly, J. Daemen, C. A. den Uil, K. Ameloot, M. Lenzen, F. Mahfoud, F. Zijlstra, J. J. Schreuder, N. M. Van Mieghem, Invasive left ventricle pressure–volume analysis: Overview and practical clinical implications. Eur. Heart J. 41, 1286– 1297 (2020). 31435675 PMC7084193 source
The General considerations section describes the ideal left-ventricular PV loop as rectangular or trapezoidal, with isovolumetric contraction, ejection, isovolumetric relaxation, and passive filling as its four phases (Figure 2A). This supports the comparison to a classic ventricular loop with filling and ejection separated by isovolumetric phases; the passage does not explicitly call those phases rapid. (LLM, conf=0.88)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Furthermore, we fabricate microfluidic valves with extreme sensitivity to rectify the flow generated by the ventricular chamber.”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: unclear — It is unclear why the paper says it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“for example, increasing from 41.7 ± 1.9 to 71.3 ± 1.5 N/m when the thickness increased from 8.3 ± 0.2 to 10.1 ± 0.3 μm (fig. S4 and table S1).”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“helical chambers were embedded in the miniPUMP device, generating bidirectional flow in the device’s channels (Fig. 2A)”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We found that only the suspension valve (Fig. 3, E and F), which was inspired after a ball check valve and consisted of a free-floating plate drifting between the open and the closed state (Fig. 3, G and H), could be fabricated to reliably rectify flow efficiently at low pressures and flow rates.”
§ Engineering a living cardiac pump on a chip using high-precision fabrication > RESULTS
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 54 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 24
- Probably not a substantial claim. 11
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This has driven a trend toward miniaturization in OOC systems, enabling reduced cell input without sacrificing essential functionality (Michas et al., 2022).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The miniaturized approach described by Michas et al. is currently the most cell-efficient (with 174,000 cells per ECC), representing a cost-saving strategy that aligns well with the broader OOC trend toward minimizing input material while retaining essential functionality (Michas et al., 2022).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Several ECCs are derived from human induced Pluripotent Stem Cells (hiPSCs), commonly differentiated into CMs and FBs (Li et al., 2018; Michas et al., 2022; Kuckelkorn et al., 2025; Ribeiro et al., 2025).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Incorporation of valves is critical for reproducing physiologic PV loops and ensuring unidirectional flow (MacQueen et al., 2018; Michas et al., 2022).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
The cited source says what the claim attributes to it.
In the citing paper
“In contrast, Michas et al. and Macqueen et al. successfully incorporated valves into microfluidic and bioreactor platforms, respectively, with Michas et al. demonstrating unidirectional flow and MacQueen et al. reporting improved PV loop morphology as a result of valve presence (Michas et al., 2022; MacQueen et al., 2018).”
From Mini-hearts for disease modeling and drug testing – process optimization versus biological functionality (2026) · cites this paper as Michas et al., 2022
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Organogenesis in a dish: Modeling development and disease using organoid technologies
Lancaster, M. A., & Knoblich, J. A. (2014) · Science · doi:10.1126/science.1247125 · Cited by 2,931 · cited 1×
“The development of such models can be attributed to progress in induced pluripotent stem cell (iPSC) technology (3), as well as innovative methods to assemble cells into aggregates and functional structures, from organoids (4) to different types of three-dimensional (3D) organ-on-chip models (5).”
BackgroundWarren, L., Manos, P. D., Ahfeldt, T., Loh, Y.-H., Li, H., Lau, F., Ebina, W., Mandal, P. K., Smith, Z. D., Meissner, A., et al. (2010) · Cell Stem Cell · doi:10.1016/j.stem.2010.08.012 · Cited by 2,662
Three-dimensional microfabrication with two-photon-absorbed photopolymerization
Maruo, S., Nakamura, O., & Kawata, S. (1997) · Optics Letters · doi:10.1364/ol.22.000132 · Cited by 1,952 · cited 11×
“Here, we harness the high precision of TPDLW to implement a miniaturized metamaterial scaffold that supports the anisotropic contraction of an in vitro cardiac ventricle, as well as functional miniaturized valves featuring sufficient sensitivity to respond to the cardiac chamber’s flow.”
MethodInfluentialInduced pluripotent stem cell technology: a decade of progress.
Shi, Y., Inoue, H., Wu, J. C., & Yamanaka, S. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.245 · Cited by 1,525 · cited 1×
“The development of such models can be attributed to progress in induced pluripotent stem cell (iPSC) technology (3), as well as innovative methods to assemble cells into aggregates and functional structures, from organoids (4) to different types of three-dimensional (3D) organ-on-chip models (5).”
BackgroundFunctional Cardiomyocytes Derived From Human Induced Pluripotent Stem Cells
Zhang, J., Wilson, G. F., Soerens, A. G., Koonce, C. H., Yu, J., Palecek, S. P., Thomson, J. A., & Kamp, T. J. (2009) · Circulation Research · doi:10.1161/circresaha.108.192237 · Cited by 1,407
Multivascular networks and functional intravascular topologies within biocompatible hydrogels
Grigoryan, B., Paulsen, S. J., Corbett, D. C., Sazer, D. W., Fortin, C. L., Zaita, A. J., Greenfield, P. T., Calafat, N. J., Gounley, J. P., Ta, A. H., et al. (2019) · Science · doi:10.1126/science.aav9750 · Cited by 1,396
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Progress and potential in organoid research
Rossi, G., Manfrin, A., & Lutolf, M. P. (2018) · Nature Reviews Genetics · doi:10.1038/s41576-018-0051-9 · Cited by 1,182
Kadic, M., Milton, G. W., van Hecke, M., & Wegener, M. (2019) · Nature Reviews Physics · doi:10.1038/s42254-018-0018-y · Cited by 1,106
Sustained in vitro intestinal epithelial culture within a Wnt-dependent stem cell niche
Ootani, A., Li, X., Sangiorgi, E., Ho, Q. T., Ueno, H., Toda, S., Sugihara, H., Fujimoto, K., Weissman, I. L., Capecchi, M. R., et al. (2009) · Nature Medicine · doi:10.1038/nm.1951 · Cited by 906
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Auxetic mechanical metamaterials
Kolken, H. M. A., & Zadpoor, A. A. (2017) · RSC Advances · doi:10.1039/c6ra27333e · Cited by 788
Palagi, S., & Fischer, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0016-9 · Cited by 716
DeForest, C. A., & Anseth, K. S. (2011) · Nature Chemistry · doi:10.1038/nchem.1174 · Cited by 708 · cited 1×
“Propelled by its increasing accessibility and throughput (26–28), as well as its potential in patterning materials to guide cell adhesion (29), spatial arrangement (30), and extracellular stiffness (20), high-precision fabrication is well poised to advance small-scale in vitro models to begin to explore fundamental in…”
BackgroundOrgans-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657 · cited 1×
“The development of such models can be attributed to progress in induced pluripotent stem cell (iPSC) technology (3), as well as innovative methods to assemble cells into aggregates and functional structures, from organoids (4) to different types of three-dimensional (3D) organ-on-chip models (5).”
BackgroundTitin mutations in iPS cells define sarcomere insufficiency as a cause of dilated cardiomyopathy
Hinson, J. T., Chopra, A., Nafissi, N., Polacheck, W. J., Benson, C. C., Swist, S., Gorham, J., Yang, L., Schafer, S., Sheng, C. C., et al. (2015) · Science · doi:10.1126/science.aaa5458 · Cited by 638
Self-citationA Platform for Generation of Chamber-Specific Cardiac Tissues and Disease Modeling
Zhao, Y., Rafatian, N., Feric, N. T., Cox, B. J., Aschar-Sobbi, R., Wang, E. Y., Aggarwal, P., Zhang, B., Conant, G., Ronaldson-Bouchard, K., et al. (2019) · Cell · doi:10.1016/j.cell.2018.11.042 · Cited by 610
Cardioids reveal self-organizing principles of human cardiogenesis
Hofbauer, P., Jahnel, S. M., Papai, N., Giesshammer, M., Deyett, A., Schmidt, C., Penc, M., Tavernini, K., Grdseloff, N., Meledeth, C., et al. (2021) · Cell · doi:10.1016/j.cell.2021.04.034 · Cited by 588
Scalable submicrometer additive manufacturing
Saha, S. K., Wang, D., Nguyen, V. H., Chang, Y., Oakdale, J. S., & Chen, S.-C. (2019) · Science · doi:10.1126/science.aax8760 · Cited by 513
Modeling human diseases with induced pluripotent stem cells: from 2D to 3D and beyond
Liu, C., Oikonomopoulos, A., Sayed, N., & Wu, J. C. (2018) · Development · doi:10.1242/dev.156166 · Cited by 267 · cited 1×
“INTRODUCTION Biomimetic tissue models are rapidly evolving toward elaborate, next-generation in vitro culture models to study organ-level function during development, adulthood, regeneration, and disease (1, 2).”
BackgroundInvasive left ventricle pressure–volume analysis: overview and practical clinical implications
Bastos, M. B., Burkhoff, D., Maly, J., Daemen, J., den Uil, C. A., Ameloot, K., Lenzen, M., Mahfoud, F., Zijlstra, F., Schreuder, J. J., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz552 · Cited by 237 · cited 3×
“4 of 12 work of generating flow against the pressure gradient and are a valuable clinical metric for the assessment of cardiac health that would greatly enhance the modeling power of in vitro models (15).”
BackgroundInfluentialA tissue-engineered scale model of the heart ventricle
MacQueen, L. A., Sheehy, S. P., Chantre, C. O., Zimmerman, J. F., Pasqualini, F. S., Liu, X., Goss, J. A., Campbell, P. H., Gonzalez, G. M., Park, S.-J., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0271-5 · Cited by 227
Self-organizing human cardiac microchambers mediated by geometric confinement
Ma, Z., Wang, J., Loskill, P., Huebsch, N., Koo, S., Svedlund, F. L., Marks, N. C., Hua, E. W., Grigoropoulos, C. P., Conklin, B. R., et al. (2015) · Nature Communications · doi:10.1038/ncomms8413 · Cited by 214 · cited 1×
“DISCUSSION iPSC-derived cardiac models have progressively evolved from 2D isotropic monolayers to anisotropically aligned layers using adhesive or topological cues (11), 3D organoids using cell-mediated self-assembly (16, 17), and linear tissue microbundles using directed self-assembly between anchoring points (12, 13…”
BackgroundMultimaterial 3D laser microprinting using an integrated microfluidic system
Mayer, F., Richter, S., Westhauser, J., Blasco, E., Barner-Kowollik, C., & Wegener, M. (2019) · Science Advances · doi:10.1126/sciadv.aau9160 · Cited by 189
Li, R. A., Keung, W., Cashman, T. J., Backeris, P. C., Johnson, B. V., Bardot, E. S., Wong, A. O. T., Chan, P. K. W., Chan, C. W. Y., & Costa, K. D. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.024 · Cited by 175 · cited 1×
“Recent efforts have extended self-assembly toward a cardiac chamber format by using innovative fabrication approaches to build centimeter- scale chambers that fill and eject fluid through their cyclic contractile activity (21, 22).”
BackgroundRichter, B., Hahn, V., Bertels, S., Claus, T. K., Wegener, M., Delaittre, G., Barner‐Kowollik, C., & Bastmeyer, M. (2017) · Advanced Materials · doi:10.1002/adma.201604342 · Cited by 162 · cited 1×
“Propelled by its increasing accessibility and throughput (26–28), as well as its potential in patterning materials to guide cell adhesion (29), spatial arrangement (30), and extracellular stiffness (20), high-precision fabrication is well poised to advance small-scale in vitro models to begin to explore fundamental in…”
BackgroundIncreased afterload induces pathological cardiac hypertrophy: a new in vitro model
Hirt, M. N., Sörensen, N. A., Bartholdt, L. M., Boeddinghaus, J., Schaaf, S., Eder, A., Vollert, I., Stöhr, A., Schulze, T., Witten, A., et al. (2012) · Basic Research in Cardiology · doi:10.1007/s00395-012-0307-z · Cited by 154
Ruan, J.-L., Tulloch, N. L., Saiget, M., Paige, S. L., Razumova, M. V., Regnier, M., Tung, K. C., Keller, G., Pabon, L., Reinecke, H., et al. (2015) · Stem Cells · doi:10.1002/stem.2036 · Cited by 131
Ma, Z., Huebsch, N., Koo, S., Mandegar, M. A., Siemons, B., Boggess, S., Conklin, B. R., Grigoropoulos, C. P., & Healy, K. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0280-4 · Cited by 109 · cited 2×
“Propelled by its increasing accessibility and throughput (26–28), as well as its potential in patterning materials to guide cell adhesion (29), spatial arrangement (30), and extracellular stiffness (20), high-precision fabrication is well poised to advance small-scale in vitro models to begin to explore fundamental in…”
BackgroundBiohybrid valveless pump-bot powered by engineered skeletal muscle
Li, Z., Seo, Y., Aydin, O., Elhebeary, M., Kamm, R. D., Kong, H., & Saif, M. T. A. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1817682116 · Cited by 107 · cited 1×
“To avoid affecting our measurements, we opted to determine the flow rate indirectly, as suggested in previous work (31), using particle”
MethodShen, M., Quertermous, T., Fischbein, M. P., & Wu, J. C. (2021) · Circulation Research · doi:10.1161/circresaha.120.318049 · Cited by 80
van Meer, B. J., Krotenberg, A., Sala, L., Davis, R. P., Eschenhagen, T., Denning, C., Tertoolen, L. G. J., & Mummery, C. L. (2019) · Nature Communications · doi:10.1038/s41467-019-12354-8 · Cited by 73
Cited by
Induced pluripotent stem cells (iPSCs): molecular mechanisms of induction and applications
Cerneckis, J., Cai, H., & Shi, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01809-0 · Cited by 452
Challenges and opportunities for the next generation of cardiovascular tissue engineering
Cho, S., Discher, D. E., Leong, K. W., Vunjak-Novakovic, G., & Wu, J. C. (2022) · Nature Methods · doi:10.1038/s41592-022-01591-3 · Cited by 176
Shiwarski, D. J., Hudson, A. R., Tashman, J. W., Bakırcı, E., Moss, S., Coffin, B. D., & Feinberg, A. W. (2025) · Science Advances · doi:10.1126/sciadv.adu5905 · Cited by 146
Lee, S. J., Jeong, W., & Atala, A. (2024) · Advanced Materials · doi:10.1002/adma.202408032 · Cited by 116
Microfluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
“A miniaturized cardiac scaffold can mimic the formation and cyclic contraction of a ventricular chamber 118 .”
Metadata
- Authors
- Michas, C., Karakan, M. Ç., Nautiyal, P., Seidman, J. G., Seidman, C. E., Agarwal, A., Ekinci, K., Eyckmans, J., White, A. E., & Chen, C. S.
- Affiliations
- Boston University (US)
- Florida International University (US)
- Harvard University (US)
- Brigham and Women's Hospital (US)
- Corresponding author
- White, Alice E.
- Chen, Christopher S.
- ORCID
- Venue
- Science Advances
- Published
- 2022-04-22
- Volume
- 8
- Issue
- 16
- Pages
- eabm3791-eabm3791
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC9032966
- OpenAlex
- W4224247795
- Cited by
- 82
- References
- 33
- Citations by year
- 2026: 10 · 2025: 20 · 2024: 26 · 2023: 21 · 2022: 5
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Science Advances (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R01HL084553, R01HL080494)
- National Institute of Biomedical Imaging and Bioengineering (UH3EB025765)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- organ-on-a-chip, cardiac pump, biomimetic tissue engineering, two-photon direct laser writing, iPSC-derived cardiomyocytes, microfluidic valves, pressure-volume loops, cardiac mechanical function
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.