Engineering a living cardiac pump on a chip using high-precision fabrication

Open access

Abstract

Biomimetic on-chip tissue models serve as a powerful tool for studying human physiology and developing therapeutics; however, their modeling power is hindered by our inability to develop highly ordered functional structures in small length scales. Here, we demonstrate how high-precision fabrication can enable scaled-down modeling of organ-level cardiac mechanical function. We use two-photon direct laser writing (TPDLW) to fabricate a nanoscale-resolution metamaterial scaffold with fine-tuned mechanical properties to support the formation and cyclic contraction of a miniaturized, induced pluripotent stem cell-derived ventricular chamber. Furthermore, we fabricate microfluidic valves with extreme sensitivity to rectify the flow generated by the ventricular chamber. The integrated microfluidic system recapitulates the ventricular fluidic function and exhibits a complete pressure-volume loop with isovolumetric phases. Together, our results demonstrate a previously unexplored application of high-precision fabrication that can be generalized to expand the accessible spectrum of organ-on-a-chip models toward structurally and biomechanically sophisticated tissue systems.

Overview

CoChat Summary

## TL;DR

The paper shows that two-photon direct laser writing can be used to build a miniaturized cardiac pump-on-a-chip with a living hiPSC-derived ventricular chamber, functional microvalves, and an afterload element. The integrated device generated unidirectional flow and a complete pressure-volume loop with isovolumetric phases, recapitulating key ventricular mechanics on a small scale.

## Key findings

  • The chamber scaffold’s axial stiffness was tunable by helix thickness: increasing helix thickness from 8.3 ± 0.2 μm to 10.1 ± 0.3 μm increased stiffness from 41.7 ± 1.9 N/m to 71.3 ± 1.5 N/m.
  • The helical chamber produced flow with a ~280 nl/s peak flow rate, ~65 nl stroke volume, and ~9.6% ejection fraction; chamber pressure varied from −1.4 Pa to 1.5 Pa.
  • The selected suspension valve increased microfluidic resistance by two orders of magnitude in the closed state, switched states at 0.25 ± 0.06 Pa (open) and 0.11 ± 0.03 Pa (closed), and had rectification ratio > 0.80 ± 0.02 below 2 Hz.
  • With valves and flow constrictor, the system produced net volume displacement of about ~4.14% ejection fraction and a complete PV loop; with a 70 μm constrictor, afterload rose to 28.6 ± 1.7 Pa from 13.1 ± 1.5 Pa with a 90 μm constrictor.

## Methods

  • Design: The authors used two-photon direct laser writing (TPDLW) to fabricate a miniaturized helical scaffold for a cardiac chamber, suspension valves for flow rectification, and flow constrictors for afterload control, all integrated into a PDMS microfluidic device.
  • Sample/data: The chamber was seeded with 170,000 hiPSC-CMs and 4,000 hMSCs per device; hiPSC-CMs were derived from the Harvard Personal Genome Project line 1 (GM23338; PGP1). Reported functional data came from representative devices, with similar traces from multiple experiments (n ≥ 3).
  • Main analysis: Flow was quantified by particle image velocimetry on fluorescent bead videos, and pressure was estimated using finite element modeling (COMSOL) and hydraulic resistance calculations; valve sensitivity, resistance, and rectification were measured under controlled pressure/flow conditions.

## Limitations

  • The paper states that the scaffold’s stiffness had “slight strain softening” and does not mimic the strain stiffening of native contracting myocardium.
  • The authors explicitly note that further investigation is required to understand the system’s electrophysiological characteristics.
  • Evident from the text: the paper mainly reports representative device traces and functional proof-of-concept rather than a large-scale quantitative study of robustness across many devices.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1126/sciadv.abm3791

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1. Miniaturized metamaterial scaffolds support contracting cardiac chambers. (A) Schematic of the complete miniPUMP system, featuring a cardiac chamber, cardiac valves, and unidirectional flow against a pressure gradient. (B) Schematic of a cardiac tissue chamber supported by a hollow TPDLW-derived scaffold. (C and D) Scanning electron microscopy (SEM) images of a chamber scaffold (C) based on the auxetic inverted hexagon unit cell (D) denoted by the dashed rectangle. (E and F) Cardiac chamber on an inverted hexagon scaffold (E) mediating the collapse of the scaffold (F) within 24 hours. The scaffold was allowed to freely deform starting the day (E) was captured. (G and H) SEM image of the helical unit cell (G) within a complete helical scaffold (H). The arrows in (G) indicate the thickness of the helix. (I to K) SEM images (I and J) and the force-displacement (K) curves of mechanical compression of helical scaffolds. Each color indicates one of the n = 3 scaffolds per helix thickness that were tested. The helix thickness was 10.1 ± 0.3 μm for the thick helix and 8.3 ± 0.2 μm for the thin helix. (L) Cardiac chamber on a helical scaffold. The scaffold was allowed to freely deform starting the day (L) was captured.
Fig. 1. Miniaturized metamaterial scaffolds support contracting cardiac chambers. (A) Schematic of the complete miniPUMP system, featuring a cardiac chamber, cardiac valves, and unidirectional flow against a pressure gradient. (B) Schematic of a cardiac tissue chamber supported by a hollow TPDLW-derived scaffold. (C and D) Scanning electron microscopy (SEM) images of a chamber scaffold (C) based on the auxetic inverted hexagon unit cell (D) denoted by the dashed rectangle. (E and F) Cardiac chamber on an inverted hexagon scaffold (E) mediating the collapse of the scaffold (F) within 24 hours. The scaffold was allowed to freely deform starting the day (E) was captured. (G and H) SEM image of the helical unit cell (G) within a complete helical scaffold (H). The arrows in (G) indicate the thickness of the helix. (I to K) SEM images (I and J) and the force-displacement (K) curves of mechanical compression of helical scaffolds. Each color indicates one of the n = 3 scaffolds per helix thickness that were tested. The helix thickness was 10.1 ± 0.3 μm for the thick helix and 8.3 ± 0.2 μm for the thin helix. (L) Cardiac chamber on a helical scaffold. The scaffold was allowed to freely deform starting the day (L) was captured.CC BY-NC · PubMed Central
Fig. 2. Computationally derived PV data of ventricular ejection. (A) Schematic of a miniPUMP system featuring a beating cardiac chamber and bidirectional chamber-induced flow. (B) Design of the microfluidic simulation model of the device in (A). The flow rate measured in (A) was used as input to the model. (C and D) Examples of the velocity (C) and pressure (D) output of the microfluidic model. (E to G) Representative examples of the measured flow rate (E), calculated ejection volume (F), and simulated intraventricular pressure (G) of a miniPUMP system as in (A) 7 days after the scaffold was allowed to freely deform. Similar traces resulted from multiple experiments performed on different occasions from distinct devices (n = 6).
Fig. 2. Computationally derived PV data of ventricular ejection. (A) Schematic of a miniPUMP system featuring a beating cardiac chamber and bidirectional chamber-induced flow. (B) Design of the microfluidic simulation model of the device in (A). The flow rate measured in (A) was used as input to the model. (C and D) Examples of the velocity (C) and pressure (D) output of the microfluidic model. (E to G) Representative examples of the measured flow rate (E), calculated ejection volume (F), and simulated intraventricular pressure (G) of a miniPUMP system as in (A) 7 days after the scaffold was allowed to freely deform. Similar traces resulted from multiple experiments performed on different occasions from distinct devices (n = 6).CC BY-NC · PubMed Central
Fig. 3. Miniaturized valves rectify the chamber-induced flow. (A to F) Schematics and SEM images of the bileaflet valve (A and B), the spring valve (C and D), and the suspension valve (E and F). (G and H) Function schematic of the suspension valve in its closed (G) and open (H) state. Blue arrows indicate flow. (I and J) The finalized design of the suspension valve in the closed (I) and open (J) state. (K) The flow rate through the suspension valve in the closed and open state under the effect of variable steady pressure characterized for a valve as in (E). The error bar represents the SE of the calculation method. (L) The minimum pressure necessary to open and close a representative suspension valve, averaged across n = 5 opening and closing cycles. (M) The rectification ratio of a valve (n = 1) actuated by rectangular pressure pulses, averaged across n = 7, 15, 25, and 49 pulse cycles at 1, 2, 3, and 4 Hz, respectively. (N) Schematic of the miniPUMP system featuring the cardiac chamber and suspension valves to achieve unidirectional flow. (O to Q) Representative examples of the volume displacement through the channels leading to the cardiac chamber (O), the supply well (P), and the output well (Q) in a device as in (N). Similar traces resulted from multiple experiments performed on different occasions from distinct miniPUMP devices (n = 9).
Fig. 3. Miniaturized valves rectify the chamber-induced flow. (A to F) Schematics and SEM images of the bileaflet valve (A and B), the spring valve (C and D), and the suspension valve (E and F). (G and H) Function schematic of the suspension valve in its closed (G) and open (H) state. Blue arrows indicate flow. (I and J) The finalized design of the suspension valve in the closed (I) and open (J) state. (K) The flow rate through the suspension valve in the closed and open state under the effect of variable steady pressure characterized for a valve as in (E). The error bar represents the SE of the calculation method. (L) The minimum pressure necessary to open and close a representative suspension valve, averaged across n = 5 opening and closing cycles. (M) The rectification ratio of a valve (n = 1) actuated by rectangular pressure pulses, averaged across n = 7, 15, 25, and 49 pulse cycles at 1, 2, 3, and 4 Hz, respectively. (N) Schematic of the miniPUMP system featuring the cardiac chamber and suspension valves to achieve unidirectional flow. (O to Q) Representative examples of the volume displacement through the channels leading to the cardiac chamber (O), the supply well (P), and the output well (Q) in a device as in (N). Similar traces resulted from multiple experiments performed on different occasions from distinct miniPUMP devices (n = 9).CC BY-NC · PubMed Central
Fig. 4. The complete miniPUMP exhibits cardiac pump function with a full PV loop. (A to C) Schematic of the miniPUMP system (A) featuring the cardiac chamber, suspension valves, and a combination of a glass column and a flow constrictor (B) to implement an elevated afterload (C). The afterload in (C) represents the mean and SD from n = 4 devices. The afterload of each device is calculated from a computational model of the channel containing the constrictor using flow measurements in the device as input. (D) Schematic of the complex 3D microfluidic model of the system in (A). (E to G) Representative examples of the calculated ejection volume (E), the simulated pressure (F), and the resulting chamber PV loop (G) from a miniPUMP device as in (A). Asterisks denote the isovolumetric phases. The inserts in (E) are magnifications of the denoted segments of (E). Similar traces resulted from multiple experiments performed on different occasions from distinct devices (n = 3) shown in fig. S13.
Fig. 4. The complete miniPUMP exhibits cardiac pump function with a full PV loop. (A to C) Schematic of the miniPUMP system (A) featuring the cardiac chamber, suspension valves, and a combination of a glass column and a flow constrictor (B) to implement an elevated afterload (C). The afterload in (C) represents the mean and SD from n = 4 devices. The afterload of each device is calculated from a computational model of the channel containing the constrictor using flow measurements in the device as input. (D) Schematic of the complex 3D microfluidic model of the system in (A). (E to G) Representative examples of the calculated ejection volume (E), the simulated pressure (F), and the resulting chamber PV loop (G) from a miniPUMP device as in (A). Asterisks denote the isovolumetric phases. The inserts in (E) are magnifications of the denoted segments of (E). Similar traces resulted from multiple experiments performed on different occasions from distinct devices (n = 3) shown in fig. S13.CC BY-NC · PubMed Central

Verification

Claims the paper makes

2 Valid · 2 Not valid · 1 Not checked · 49 Own results and interpretations

19 more claims

Create a free account to see all 54 claims and to verify the 1 reference still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • Probably not a substantial claim. 11

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

3 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 33 references

Cited by

See all 82

Metadata

Authors
Michas, C., Karakan, M. Ç., Nautiyal, P., Seidman, J. G., Seidman, C. E., Agarwal, A., Ekinci, K., Eyckmans, J., White, A. E., & Chen, C. S.
Affiliations
  • Boston University (US)
  • Florida International University (US)
  • Harvard University (US)
  • Brigham and Women's Hospital (US)
Corresponding author
  • White, Alice E.
  • Chen, Christopher S.
Venue
Science Advances
Published
2022-04-22
Volume
8
Issue
16
Pages
eabm3791-eabm3791
ISSN
2375-2548 (ISSN-L)
OpenAlex
W4224247795
Cited by
82
References
33
Citations by year
2026: 10 · 2025: 20 · 2024: 26 · 2023: 21 · 2022: 5
FWCI
5.23
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
  • National Heart, Lung, and Blood Institute (R01HL084553, R01HL080494)
  • National Institute of Biomedical Imaging and Bioengineering (UH3EB025765)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
organ-on-a-chip, cardiac pump, biomimetic tissue engineering, two-photon direct laser writing, iPSC-derived cardiomyocytes, microfluidic valves, pressure-volume loops, cardiac mechanical function

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.