The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Zero-Mode Waveguides for Single-Molecule Analysis at High Concentrations
Abstract
Optical approaches for observing the dynamics of single molecules have required pico- to nanomolar concentrations of fluorophore in order to isolate individual molecules. However, many biologically relevant processes occur at micromolar ligand concentrations, necessitating a reduction in the conventional observation volume by three orders of magnitude. We show that arrays of zero-mode waveguides consisting of subwavelength holes in a metal film provide a simple and highly parallel means for studying single-molecule dynamics at micromolar concentrations with microsecond temporal resolution. We present observations of DNA polymerase activity as an example of the effectiveness of zero-mode waveguides for performing single-molecule experiments at high concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Inhibited Spontaneous Emission in Solid-State Physics and Electronics
Yablonovitch, E. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.2059 · Cited by 14,067
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Self-citationMicro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Single-Molecule Enzymatic Dynamics
Lu, H. P. (1998) · Science · doi:10.1126/science.282.5395.1877 · Cited by 1,470
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
Self-citationFluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Single Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
Inhibited Spontaneous Emission
Kleppner, D. (1981) · Physical Review Letters · doi:10.1103/physrevlett.47.233 · Cited by 1,067
Patel, S. S., Wong, I., & Johnson, K. A. (1991) · Biochemistry · doi:10.1021/bi00216a029 · Cited by 492
Statistical accuracy in fluorescence correlation spectroscopy
Koppel, D. E. (1974) · Physical Review A · doi:10.1103/physreva.10.1938 · Cited by 450
Thompson, N. L., Burghardt, T. P., & Axelrod, D. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84905-3 · Cited by 316
Xie, X. S., & Lu, H. P. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.23.15967 · Cited by 268
Single-molecule detection by two-photon-excited fluorescence
Mertz, J., Xu, C., & Webb, W. W. (1995) · Optics Letters · doi:10.1364/ol.20.002532 · Cited by 225
Self-citationCell biology beyond the diffraction limit: near-field scanning optical microscopy
de Lange, F., Cambi, A., Huijbens, R., de Bakker, B., Rensen, W., Garcia-Parajo, M., van Hulst, N., & Figdor, C. G. (2001) · Journal of Cell Science · doi:10.1242/jcs.114.23.4153 · Cited by 206
Direct haplotyping of kilobase-size DNA using carbon nanotube probes
Woolley, A. T., Guillemette, C., Li Cheung, C., Housman, D. E., & Lieber, C. M. (2000) · Nature Biotechnology · doi:10.1038/77760 · Cited by 168
Fluorescence correlation spectroscopy for the detection and study of single molecules in biology
Medina, M. Á., & Schwille, P. (2002) · BioEssays · doi:10.1002/bies.10118 · Cited by 166
Barak, L. S., & Webb, W. W. (1981) · The Journal of Cell Biology · doi:10.1083/jcb.90.3.595 · Cited by 129
Self-citationStarr, T. E., & Thompson, N. L. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76130-9 · Cited by 127
Schomburg, D., Scomburg, I., & Chang, A. (2007) · Springer eBooks · doi:10.1007/978-3-540-47818-8 · Cited by 47
Conformational-relaxation models of single-enzyme kinetics
Lerch, H.-P., Mikhailov, A. S., & Hess, B. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232376799 · Cited by 34
Cited by
Sequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066
Next-generation DNA sequencing
Shendure, J., & Ji, H. (2008) · Nature Biotechnology · doi:10.1038/nbt1486 · Cited by 4,509
Plasmonics for extreme light concentration and manipulation
Schuller, J. A., Barnard, E. S., Cai, W., Jun, Y. C., White, J. S., & Brongersma, M. L. (2010) · Nature Materials · doi:10.1038/nmat2630 · Cited by 4,364
Coming of age: ten years of next-generation sequencing technologies
Goodwin, S., McPherson, J. D., & McCombie, W. R. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2016.49 · Cited by 4,352
Real-Time DNA Sequencing from Single Polymerase Molecules
Eid, J., Fehr, A., Gray, J., Luong, K., Lyle, J., Otto, G., Peluso, P., Rank, D., Baybayan, P., Bettman, B., et al. (2009) · Science · doi:10.1126/science.1162986 · Cited by 3,732
Self-citation
Metadata
- Authors
- Levene, M. J., Korlach, J., Turner, S. W., Foquet, M., Craighead, H. G., & Webb, W. W.
- Venue
- Science
- Published
- 2003-01-31
- Volume
- 299
- Issue
- 5607
- Pages
- 682-686
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1982538875
- Cited by
- 1,378
- References
- 24
- FWCI
- 33.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.