Tumor Detection by Nuclear Magnetic Resonance
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Spin echo nuclear magnetic resonance measurements may be used as a method for discriminating between malignant tumors and normal tissue. Measurements of spin-lattice ( T 1 ) and spin-spin ( T 2 ) magnetic relaxation times were made in six normal tissues in the rat (muscle, kidney, stomach, intestine, brain, and liver) and in two malignant solid tumors, Walker sarcoma and Novikoff hepatoma. Relaxation times for the two malignant tumors were distinctly outside the range of values for the normal tissues studied, an indication that the malignant tissues were characterized by an increase in the motional freedom of tissue water molecules. The possibility of using magnetic relaxation methods for rapid discrimination between benign and malignant surgical specimens has also been considered. Spin-lattice relaxation times for two benign fibroadenomas were distinct from those for both malignant tissues and were the same as those of muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Biological Effects of Magnetic Fields
(1995) · Springer eBooks · doi:10.1007/978-1-4684-8352-9 · Cited by 337
Nuclear Magnetic Resonance Evidence using D2O for Structured Water in Muscle and Brain
Cope, F. W. (1969) · Biophysical Journal · doi:10.1016/s0006-3495(69)86388-5 · Cited by 258
Nuclear Magnetic Resonance Studies of Living Muscle
Bratton, C. B., Hopkins, A. L., & Weinberg, J. W. (1965) · Science · doi:10.1126/science.147.3659.738 · Cited by 180
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Water as an active constituent in cell biology
Ball, P. (2008) · Chemical Reviews · doi:10.1021/cr068037a · Cited by 2,177
Methods for the assessment of human body composition: traditional and new
Lukaski, H. C. (1987) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/46.4.537 · Cited by 1,152
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Spin warp NMR imaging and applications to human whole-body imaging
Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/4/017 · Cited by 803
A flow velocity zeugmatographic interlace for NMR imaging in humans
Moran, P. R. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90170-9 · Cited by 745
Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials
(2015) · Neuro-Oncology · doi:10.1093/neuonc/nov095 · Cited by 663
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Effects of Molecular Crowding on the Structures, Interactions, and Functions of Nucleic Acids
Nakano, S.-I., Miyoshi, D., & Sugimoto, N. (2014) · Chemical Reviews · doi:10.1021/cr400113m · Cited by 567
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Human Body Composition: Advances in Models and Methods
B. Heymsfield, S., Wang, Z., Baumgartner, R. N., & Ross, R. (1997) · Annual Review of Nutrition · doi:10.1146/annurev.nutr.17.1.527 · Cited by 527
19F magnetic resonance imaging
Holland, G. N., Bottomley, P. A., & Hinshaw, W. S. (1977) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(77)90263-3 · Cited by 491
Gadolinium‐based contrast agents for magnetic resonance cancer imaging
Zhou, Z., & Lu, Z. (2013) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1198 · Cited by 427
Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simple
Weigel, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24619 · Cited by 426
Mahmoudi, M., Hosseinkhani, H., Hosseinkhani, M., Boutry, S., Simchi, A., Journeay, W. S., Subramani, K., & Laurent, S. (2011) · Chemical Reviews · doi:10.1021/cr1001832 · Cited by 418
Practical T2 quantitation for clinical applications
Poon, C. S., & Henkelman, R. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020512 · Cited by 393
MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Mansfield, P., & Maudsley, A. A. (1977) · The British Journal of Radiology · doi:10.1259/0007-1285-50-591-188 · Cited by 364
Neural bases of personal and extrapersonal neglect in humans
Committeri, G., Pitzalis, S., Galati, G., Patria, F., Pelle, G., Sabatini, U., Castriota-Scanderbeg, A., Piccardi, L., Guariglia, C., & Pizzamiglio, L. (2007) · Brain · doi:10.1093/brain/awl265 · Cited by 322
“The combination of different MR parameters, mainly T1 and T2 relaxation times, may thus provide not only sensitivity, but tissue specificity, allowing the complete and accurate characterization of pathological tissue in vivo (e.g. Damadian, 1971).”
BackgroundErnst, R. R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.08.006 · Cited by 314
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Depth and refocusing pulses designed for multipulse NMR with surface coils
Robin Bendall, M., & Gordon, R. E. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90211-1 · Cited by 306
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Low-field permanent magnets for industrial process and quality control
Mitchell, J., Gladden, L. F., Chandrasekera, T. C., & Fordham, E. J. (2014) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.09.001 · Cited by 300
Molecular crowding effects on structure and stability of DNA
Miyoshi, D., & Sugimoto, N. (2008) · Biochimie · doi:10.1016/j.biochi.2008.02.009 · Cited by 291
Single-scan multidimensional magnetic resonance
Tal, A., & Frydman, L. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.04.001 · Cited by 277
Recent advances in the NMR of solid polymers
McBrierty, V. J., & Douglass, D. C. (1981) · Journal of Polymer Science: Macromolecular Reviews · doi:10.1002/pol.1981.230160105 · Cited by 271
Cleveland, G. G., Chang, D. C., Hazlewood, C. F., & Rorschach, H. E. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85754-2 · Cited by 243
Latest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 223
“These differences were previously exploited in 1971 by Damadian, who found that relaxation times in cancerous tissue samples from rats were longer than those in noncancerous tissue (79).”
BackgroundPlewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 220
Cell water dynamics on multiple time scales
Persson, E., & Halle, B. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709585105 · Cited by 217
“In fact, tissue-specific variations in water relaxation times provided the impetus for developing magnetic resonance imaging (10).”
BackgroundAssessing skeletal muscle mass: historical overview and state of the art
Heymsfield, S. B., Adamek, M., Gonzalez, M. C., Jia, G., & Thomas, D. M. (2014) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1007/s13539-014-0130-5 · Cited by 212
“Raymond Damadian, working at SUNY Downstate, completed construction of the first whole-body MRI scanner in 1977 [43] and equipment for hospitals became available during the early 1980s.”
BackgroundAnalysis of biological NMR relaxation data with continuous distributions of relaxation times
Kroeker, R. M., & Mark Henkelman, R. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90074-0 · Cited by 210
Normal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging
Maier, S. E., Bogner, P., Bajzik, G., Mamata, H., Mamata, Y., Repa, I., Jolesz, F. A., & Mulkern, R. V. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn02842 · Cited by 158
“For patient imaging, diffusion was measured along only a single direction, in a ( 1 ,1,1) gradient configuration to achieve maximal diffusion encoding”
BackgroundMethodInfluentialEllingson, B. M. (2015) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-014-0506-0 · Cited by 132
Biological wires, communication systems, and implications for disease
Friesen, D. E., Craddock, T. J. A., Kalra, A. P., & Tuszynski, J. A. (2015) · Biosystems · doi:10.1016/j.biosystems.2014.10.006 · Cited by 48
Metadata
- Authors
- Damadian, R.
- Venue
- Science
- Published
- 1971-03-19
- Volume
- 171
- Issue
- 3976
- Pages
- 1151-1153
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2086807063
- Cited by
- 1,466
- References
- 4
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.