Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Electrospray ionization with an ultralow flow rate (≤4 nanoliters per minute) was used to directly couple capillary electrophoresis with tandem mass spectrometry for the analysis and identification of biomolecules in mixtures. A Fourier transform mass spectrometer provided full spectra (>30 kilodaltons) at a resolving power of ≈60,000 for injections of 0.7 × 10 −18 to 3 × 10 −18 mole of 8- to 29-kilodalton proteins with errors of <1 dalton in molecular mass. Using a crude isolate from human blood, a value of 28,780.6 daltons (calculated, 28,780.4 daltons) was measured for carbonic anhydrase, representing 1 percent by weight of the protein in a single red blood cell. Dissociation of molecular ions from 9 × 10 −18 mole of carbonic anhydrase gave nine sequence-specific fragment ions, more data than required for unique retrieval of this enzyme from the protein database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Capillary Zone Electrophoresis
Jorgenson, J. W., & Lukacs, K. D. (1983) · Science · doi:10.1126/science.6623076 · Cited by 1,289
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Curl, R. F., & Smalley, R. E. (1988) · Science · doi:10.1126/science.242.4881.1017 · Cited by 469
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Purification and properties of bovine erythrocyte carbonic anhydrase
Lindskog, S. F. (1960) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(60)90156-6 · Cited by 255
Mørtz, E., O'Connor, P. B., Roepstorff, P., Kelleher, N. L., Wood, T. D., McLafferty, F. W., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8264 · Cited by 220
Self-citationAttomole-Sensitivity Electrospray Source for Large-Molecule Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., Little, D. P., Aaserud, D. J., & McLafferty, F. W. (1995) · Analytical Chemistry · doi:10.1021/ac00116a030 · Cited by 217
Self-citationHigh-resolution tandem FT mass spectrometry above 10 kDa
McLafferty, F. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00047a009 · Cited by 194
Self-citationLoo, J. A., Edmonds, C. G., & Smith, R. D. (1991) · Analytical Chemistry · doi:10.1021/ac00021a018 · Cited by 189
Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85017-r · Cited by 157
Self-citationHofstadler, S. A., Severs, J. C., Smith, R. D., Swanek, F. D., & Ewing, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<919::aid-rcm597>3.0.co;2-8 · Cited by 137
Capillary Electrophoresis/Mass Spectrometry
Smith, R. D., Wahl, J. H., Goodlett, D. R., & Hofstadler, S. A. (1993) · Analytical Chemistry · doi:10.1021/ac00061a717 · Cited by 133
Automated assignment of charge states from resolved isotopic peaks for multiply charged ions
Senko, M. W., Beu, S. C., & McLafferty, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)00091-d · Cited by 119
Self-citationHigh‐resolution tandem mass spectra of 37‐67 kDa proteins
Speir, J. P., Senko, M. W., Little, D. P., Loo, J. A., & McLafferty, F. W. (1995) · Journal of Mass Spectrometry · doi:10.1002/jms.1190300108 · Cited by 86
Self-citationWahl, J. H., Goodlett, D. R., Udseth, H. R., & Smith, R. D. (1993) · ELECTROPHORESIS · doi:10.1002/elps.1150140170 · Cited by 86
Analytical chemistry in microenvironments: single nerve cells
Ewing, A. G., Strein, T. G., & Lau, Y. Y. (1992) · Accounts of Chemical Research · doi:10.1021/ar00022a002 · Cited by 79
On-line capillary electrophoresis with Fourier transform ion cyclotron resonance mass spectrometry
Hofstadler, S. A., Wahl, J. H., Bruce, J. E., & Smith, R. D. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00068a070 · Cited by 72
Composition of Normal Human Red Cells
PENNELL, R. B. (1974) · Elsevier eBooks · doi:10.1016/b978-0-12-677201-2.50009-x · Cited by 48
Kelleher, N. L., Costello, C. A., Begley, T. P., & McLafferty, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00584-z · Cited by 40
Self-citationValaskovic, G. A., & McLafferty, F. W. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199605)10:7<825::aid-rcm569>3.0.co;2-q · Cited by 32
Self-citation
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
“Its strengths are high sensitivity, mass accuracy, resolution and dynamic rang”
BackgroundFourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationAnalysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Self-citation
Metadata
- Authors
- Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W.
- Venue
- Science
- Published
- 1996-08-30
- Volume
- 273
- Issue
- 5279
- Pages
- 1199-1202
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1968746767
- Cited by
- 398
- References
- 25
- FWCI
- 23.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.