CoChat

Elastomeric passive transmission for autonomous force-velocity adaptation applied to 3D-printed prosthetics

The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

A 3D-printed passively variable transmission for rapid, strong actuation is shown in a lightweight, tendon-driven prosthetic hand.

Overview

Integrity signals

Registry

Crossref · 10.1126/scirobotics.aau5543

Cites

36 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 6

  1. M. V. Liarokapis A. G. Zisimatos C. I. Mavrogiannis K. J. Kyriakopoulos. OPENBIONICS: An open-source initiative for the creation of affordable modular light-weight underactuated robot hands and prosthetic devices in 2nd ASU Rehabilitation Robotics Workshop (Arizona State University 2014).
  2. Y. Ishikawa W. Yu H. Yokoi Y. Kakazu Development of robot hands with an adjustable power transmitting mechanism in Intelligent Engineering Systems Through Neural Networks (ASME Press 2000) vol. 10 pp. 631–636.
  3. J. W. Sensinger R. F. Weir Design and analysis of a non-backdrivable series elastic actuator in 9th International Conference on Rehabilitation Robotics 2005 (ICORR 2005) pp. 390–393. · doi:10.1109/icorr.2005.1501126
  4. R. F. Weir J. W. Sensinger Design of artificial arms and hands for prosthetic applications in Standard Handbook of Biomedical Engineering and Design (McGraw-Hill Professional 2003) chap. 32.
  5. A. Arienti M. Calisti F. Giorgio-Serchi C. Laschi Poseidrone: Design of a soft-bodied ROV with crawling swimming and manipulation ability in Oceans-San Diego (IEEE 2013) pp. 1–7.
  6. H. G. Marques M. Christophe A. Lenz K. Dalamagkidis U. Culha MYOROBOTICS: A modular toolkit for legged locomotion research using musculoskeletal designs presented at the 6th International Symposium on Adaptive Motion of Animals and Machines Darmstadt Germany 11 to 13 March 2013 (AMAM 2013).

Cited by

See all 78

Metadata

Authors
O’Brien, K. W., Xu, A., Levine, D. J., Aubin, C. A., Yang, H.-J., Xiao, M. F., Wiesner, L. W., & Shepherd, R. F.
Affiliations
Cornell University (US)
Corresponding author
Shepherd, Robert F.
Venue
Science Robotics
Published
2018-10-17
Volume
3
Issue
23
ISSN
2470-9476 (ISSN-L)
OpenAlex
W2896709460
Cited by
71
References
36
Citations by year
2026: 5 · 2025: 8 · 2024: 8 · 2023: 9 · 2022: 15 · 2021: 12 · 2020: 8 · 2019: 6
FWCI
2.60
Type
journal article
Language
en
Open access
closed
Locations
  • Science Robotics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation (DMR-1719875)
  • Office of Naval Research (N00014-17-1-2837)
  • Air Force Office of Scientific Research (FA9550-18-1-0243)
  • National Center for Advancing Translational Sciences (TL1TR002386)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
3D-printed prostheses, variable transmission, soft robotics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.