A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
An electronic interface for recording and stimulating nerves that innervate the bladder helps to restore normal bladder function in rats with spinal cord injury.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the severe implantation trauma caused by the full dissection of the epineurium can lead to axon damage, certain nerves are able to support this implantation procedure (Chew et al., 2013).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Chew et al., 2013
In the citing paper
“Microchannels were implanted on the dorsal surface of the S1-S2 spinal cord for feedback control of bladder functions [Fig.4(j)] 110”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [110]
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · cited 1×
“Regaining bladder control is among the principal desires of patients presenting with spinal cord injury (4).”
BackgroundThe neural control of micturition
Fowler, C. J., Griffiths, D., & de Groat, W. C. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2401 · Cited by 1,485 · cited 1×
“Normal micturition depends on coordinated bladder contraction and sphincter relaxation controlled by the lumbosacral neuronal circuitry, and is initiated and inhibited by descending control from the brainstem (1, 2).”
BackgroundConduction velocity is related to morphological cell type in rat dorsal root ganglion neurones.
Harper, A. A., & Lawson, S. N. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015573 · Cited by 745 · cited 1×
“25m/s, suggesting that Aa-b axons predominate in the compound action potential, with slower unit activity falling within the range of thinly myelinated Ad and C axons, in accordance with published literature on primary afferent classification (37, 38).”
ResultThe first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313
Sengupta, J. N., & Gebhart, G. F. (1994) · Journal of Neurophysiology · doi:10.1152/jn.1994.72.5.2420 · Cited by 246
High‐frequency electrical conduction block of mammalian peripheral motor nerve
Bhadra, N., & Kilgore, K. L. (2005) · Muscle & Nerve · doi:10.1002/mus.20428 · Cited by 239 · cited 1×
“This is an effective way to block conduction in the sciatic nerve (42) as well as ventral roots (43) and pudendal nerves (44) that innervate the urethral sphincter.”
BackgroundCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177 · cited 1×
“Together, these findings put in place the necessary tools to attempt a revision of the bladder control device initiated byBrindleymore than 30 years ago (5).”
Electrophysiological study of micturition reflexes in rats
Mallory, B., Steers, W. D., & De Groat, W. C. (1989) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1989.257.2.r410 · Cited by 169 · cited 2×
“In humans with full bladders, spontaneous voiding contractions occur every fewminutes, whereas in rats with a full bladder, we saw regular contractions about every 10 to 20 s, in accordance with previous data (34).”
BackgroundResult
Cited by
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Self-citationTopological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Choi, S., Han, S. I., Kim, D., Hyeon, T., & Kim, D.-H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00706c · Cited by 591
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Such microchannel electrodes have, for example, been implanted in nerves at locations very proximal to the dorsal root ganglia to monitor bladder function in rodents at long-term implantation time points (Chew et al., 2013).”
BackgroundBioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Lee, S., Shi, Q., & Lee, C. (2019) · APL Materials · doi:10.1063/1.5063498 · Cited by 164
Applications of nanogenerators for biomedical engineering and healthcare systems
Wang, W., Pang, J., Su, J., Li, F., Li, Q., Wang, X., Wang, J., Ibarlucea, B., Liu, X., Li, Y., et al. (2021) · InfoMat · doi:10.1002/inf2.12262 · Cited by 122
Biomimetic Microelectronics for Regenerative Neuronal Cuff Implants
Karnaushenko, D., Münzenrieder, N., Karnaushenko, D. D., Koch, B., Meyer, A. K., Baunack, S., Petti, L., Tröster, G., Makarov, D., & Schmidt, O. G. (2015) · Advanced Materials · doi:10.1002/adma.201503696 · Cited by 120
Toward Bioelectronic Medicine—Neuromodulation of Small Peripheral Nerves Using Flexible Neural Clip
Lee, S., Peh, W. Y. X., Wang, J., Yang, F., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2017) · Advanced Science · doi:10.1002/advs.201700149 · Cited by 96
Microfluidic neural probes: in vivo tools for advancing neuroscience
Sim, J. Y., Haney, M. P., Park, S. I., McCall, J. G., & Jeong, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00103g · Cited by 94
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
“In addition, neural recordings are essential for brain–machine interfaces [59] and closed-loop therapeutic devices that interface with the brain [9, 15], nerves [22, 116] or visceral organs [44].”
BackgroundStretchable Low Impedance Electrodes for Bioelectronic Recording from Small Peripheral Nerves
Decataldo, F., Cramer, T., Martelli, D., Gualandi, I., Korim, W. S., Yao, S. T., Tessarolo, M., Murgia, M., Scavetta, E., Amici, R., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-46967-2 · Cited by 74
Gribi, S., du Bois de Dunilac, S., Ghezzi, D., & Lacour, S. P. (2018) · Nature Communications · doi:10.1038/s41467-018-06895-7 · Cited by 72
Self-citationChronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70
Self-citationAlam, M., Rodrigues, W., Pham, B., & Thakor, N. V. (2016) · Brain Research · doi:10.1016/j.brainres.2016.05.039 · Cited by 79
Prevention of the foreign body response to implantable medical devices by inflammasome inhibition
Barone, D. G., Carnicer-Lombarte, A., Tourlomousis, P., Hamilton, R. S., Prater, M., Rutz, A. L., Dimov, I. B., Malliaras, G. G., Lacour, S. P., Robertson, A. A. B., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115857119 · Cited by 67
“In this model, axons and glia regenerate through the microchannels to restore function and the channels can function as an electrical interface (21, 22).”
BackgroundSelf-citationApplication of Graphene in Tissue Engineering of the Nervous System
Ławkowska, K., Pokrywczyńska, M., Koper, K., Kluth, L. A., Drewa, T. A., & Adamowicz, J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms23010033 · Cited by 67
Badia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
High-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Initiation of Bladder Voiding with Epidural Stimulation in Paralyzed, Step Trained Rats
Gad, P. N., Roy, R. R., Zhong, H., Lu, D. C.-T., Gerasimenko, Y., & Edgerton, V. R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0108184 · Cited by 61
“Recently a closed-loop neuroprosthesis interface was used to measure bladder fullness through implanted afferent dorsal rootlets into microchannel electrodes to measure and interpret sensory activity related to bladder fullness in spinal rats [30].”
MethodStauffer, F., Zhang, Q., Tybrandt, K., Zambrano, B. L., Hengsteler, J., Stoll, A., Trueeb, C., Hagander, M., Sujata, J., Hoffmann, F., et al. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800031 · Cited by 60
Carnicer‐Lombarte, A., Boys, A. J., Güemes, A., Gurke, J., Velasco‐Bosom, S., Hilton, S., Barone, D. G., & Malliaras, G. G. (2024) · Nature Communications · doi:10.1038/s41467-024-51988-1 · Cited by 60
“Our choice of electrode dimensions and layout wassimilarto those of multielectrode cuffs able to record 20 and stimulate at high resolutions 21 .”
Dong, W., Cheng, X. L., Xiong, T., & Wang, X. (2019) · Biomedical Microdevices · doi:10.1007/s10544-018-0353-x · Cited by 57
Recent progress on peripheral neural interface technology towards bioelectronic medicine
Cho, Y., Park, J., Lee, C., & Lee, S. (2020) · Bioelectronic Medicine · doi:10.1186/s42234-020-00059-z · Cited by 55
“An alternative approach is proposed through the modulation of bladder nerves by using neural interfaces (Chew et al. 2013).”
A guide towards long-term functional electrodes interfacing neuronal tissue
Renz, A. F., Reichmuth, A. M., Stauffer, F., Thompson-Steckel, G., & Vörös, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae0c2 · Cited by 50
“One example demonstrated this by placing surgically separated roots into multiple channels of soft microelectrode arrays (MEAs) to monitor bladder filling and contraction activity in rats for two months [52].”
MethodImplantable Sensors for Regenerative Medicine
Klosterhoff, B. S., Tsang, M., She, D., Ong, K. G., Allen, M. G., Willett, N. J., & Guldberg, R. E. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4035436 · Cited by 48
Carnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46
Zamani, M., & Demosthenous, A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2309678 · Cited by 49
“-Extrema could be used as the basis of a future neural amplifying and spike sorting chip for upper-limb prostheses or other applications such as cortical neural recording [27] and bladder control after spinal cord injury [28].”
Peripheral Nerve Conduction Block by High-Frequency Alternating Currents: A Systematic Review
Avendaño‐Coy, J., Serrano‐Muñoz, D., Taylor, J., Goicoechea, C., & Gómez‐Soriano, J. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2833141 · Cited by 41
“In experiments “in vitro”, the nerve block was determined by recording action potentials [43]–[46], and in experiments “in vivo”, it was determined either by recording the force of a muscle [3], [19]–[33], [39], [42] or by recording the pressure of the urethral sphincter [4], [34]–[38], [40], [41].”
MethodResearch Update: Platinum-elastomer mesocomposite as neural electrode coating
Minev, I. R., Wenger, N., Courtine, G., & Lacour, S. P. (2015) · APL Materials · doi:10.1063/1.4906502 · Cited by 36
Self-citationMetcalfe, B., Nielsen, T. N., Donaldson, N., Hunter, A. J., & Taylor, J. T. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-017-0054-z · Cited by 37
“This is convincing evidence that action potential velocities can be detected using the VSD method, not only from microchannels [17] but sometimes, as in this experiment, from cuffs on whole nerves, if the internal resistance of the cuff is high.”
MethodSelf-citationA Multichannel High-Frequency Power-Isolated Neural Stimulator With Crosstalk Reduction
Jiang, D., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2832541 · Cited by 36
“real perceptual sensation, state-of-the-art neural stimulators for the spinal cord [7], and the peripheral nervous system [8], [9] are also enhanced with novel electrode design features such as”
BackgroundNovel Neurostimulation of Autonomic Pelvic Nerves Overcomes Bladder-Sphincter Dyssynergia
Peh, W. Y. X., Mogan, R. P., Thow, X. Y., Chua, S. M., Rusly, A., Thakor, N. V., & Yen, S.-C. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00186 · Cited by 35
Metcalfe, B. W., Chew, D. J., Clarke, C. T., Donaldson, N. D. N., & Taylor, J. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.05.003 · Cited by 34
“The left fifth lumbar dorsal root (L5) was micro-dissected into fine rootlets/fascicles with fine glass pulled pipettes, in a method described previously [12],[13],[14].”
Self-citationChronic monitoring of lower urinary tract activity via a sacral dorsal root ganglia interface
Khurram, A., Ross, S. E., Sperry, Z. J., Ouyang, Z., Stephan, C., Jiman, A. A., & Bruns, T. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6801 · Cited by 34
Biodegradable batteries with immobilized electrolyte for transient MEMS
She, D., Tsang, M., & Allen, M. G. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0377-x · Cited by 31
Electronic Skins for Healthcare Monitoring and Smart Prostheses
Chen, H., Dejace, L., & Lacour, S. P. (2020) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-071320-101023 · Cited by 31
Self-citationRoss, S. E., Ouyang, Z., Rajagopalan, S., & Bruns, T. M. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1966-6 · Cited by 29
Feasibility of Real-Time Conditional Sacral Neuromodulation Using Wireless Bladder Pressure Sensor
Majerus, S. J. A., Offutt, S. J., Brink, T. S., Vasoli, V. M., McAdams, I. S., Damaser, M. S., & Zirpel, L. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3117518 · Cited by 28
Ren, J., Chew, D. J., Biers, S. M., & Thiruchelvam, N. (2015) · Neurourology and Urodynamics · doi:10.1002/nau.22730 · Cited by 29
Self-citationEmerging Neural Stimulation Technologies for Bladder Dysfunctions
Lee, J. W., Kim, D., Yoo, S., Lee, H., Lee, G.-H., & Nam, Y. (2015) · International Neurourology Journal · doi:10.5213/inj.2015.19.1.3 · Cited by 32
“In cases of bladder control problems, efforts have been made in several studies to monitor the bladder state and to control the time course of bladder storage and emptying, thus providing a basis for developing closed-loop bladder neuroprostheses without the need for transecting the nerves [9,14,31].”
BackgroundPeña, E., Pelot, N. A., & Grill, W. M. (2021) · Scientific Reports · doi:10.1038/s41598-021-84503-3 · Cited by 26
In vitro multichannel single-unit recordings of action potentials from the mouse sciatic nerve
Chen, L., Ilham, S. J., Guo, T., Emadi, S., & Feng, B. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa7efa · Cited by 26
Design of Ceramic Packages for Ultrasonically Coupled Implantable Medical Devices
Shen, K., & Maharbiz, M. M. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2957732 · Cited by 24
“within the body for several months; this lifetime is similar to that of conventional polymer-based encapsulation techniques [25], [47]–[49].”
BackgroundSoft, wireless and subdermally implantable recording and neuromodulation tools
Cai, L., & Gutruf, P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe805 · Cited by 24
Metcalfe, B., Hunter, A. J., Graham-Harper-Cater, J., & Taylor, J. T. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108967 · Cited by 22
“The dorsal roots were exposed by incision through the dura and the left fifth lumbar dorsal root was micro-dissected into fine rootlets/fascicles with fine glass pulled pipettes, in a method described previously [27, 28, 29].”
MethodSrinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E., Song, C., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., et al. (2016) · European Journal of Neuroscience · doi:10.1111/ejn.13080 · Cited by 20
“Acute non-regenerative implementations of microchannels have been evaluated, whereby dissected nerve strands were placed in microchannels and recordings were performed (Delivopoulos et al., 2012; Minev et al., 2012; Chew et al., 2013).”
BackgroundMethodResultSelf-citationPeña, E., Pelot, N. A., & Grill, W. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abadb5 · Cited by 21
“Most studies used sine waves (Bhadra and Kilgore 2005; Williamson and Andrews 2005; Gaunt and Prochazka 2009; Dowden et al. 2010; Chew et al. 2013; Patel and Butera 2015; Jiman et al. 2019), and others used square waves (Boger et al. 2013; Buckley et al. 2017; Yang et al. 2017) or trains of…”
BackgroundPikov, V., McCreery, D. B., & Han, M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abca13 · Cited by 21
Tutorial: a guide to techniques for analysing recordings from the peripheral nervous system
Koh, R. G. L., Zariffa, J., Jabban, L., Yen, S., Donaldson, N., & Metcalfe, B. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7d74 · Cited by 19
“One exception to this is the microchannel interface, in which the nerve trunk may be micro-dissected into fascicles that may then be placed within channels that constrain the extracellular space [49].”
BackgroundSelf-citationLim, J., Zoss, P., Powley, T. L., Lee, H., & Ward, M. P. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00637-6 · Cited by 20
“…(PDMS) based microchannel device (200 µm thick), which was implanted in teased dorsal roots (dorsal rootlets) within the rat vertebral column to measure bladder fullness and to prevent spontaneous voiding episodes in rats with neurogenic bladder caused by spinal cord injury 24 .”
BackgroundMethodInfluentialGuo, T., Chen, L., Tran, K. T. M., Ghelich, P., Guo, Y., Nolta, N. F., Emadi, S., Han, M., & Feng, B. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128111 · Cited by 18
“Recently, a flexible microchannel electrode array was developed for single-unit recordings from teased spinal nerve or dorsal root filaments of about 100 μm thick [24, 25].”
MethodMinimally invasive probes for programmed microfluidic delivery of molecules in vivo
McCall, J. G., & Jeong, J. (2017) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2017.08.010 · Cited by 16
Knight, S. L., Edirisinghe, N., Leaker, B. R., Susser, J., & Craggs, M. D. (2017) · Neurourology and Urodynamics · doi:10.1002/nau.23310 · Cited by 16
“This has been achieved through recording of intra-vesical pressure,(14,15) by using the dyssynergic activity of the urethral or anal sphincters or with more technical difficulty by recording from bladder sensory nerves.(19) CN has been shown to be as effective as continuous neuromodulation in suppressing NDO and incre…”
MethodSelf-citationAn ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15
“would allow for amplifier settling and firing rate recordings, and is appropriate for the case described in [21] where changes occur over minutes.”
BackgroundInfluentialSelf-citationSpinal cord bioelectronic interfaces: opportunities in neural recording and clinical challenges
Jiang, L., Woodington, B. J., Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac605f · Cited by 16
“Recording these signals can be paired with sacral nerve stimulation to create closed-loop bladder emptying neuroprosthetics [136], improving on current open-loop designs such as the Finetech-Brindley stimulator [137] (Vocare® system, USA).”
BackgroundClosed-loop stimulation of the pelvic nerve for optimal micturition
Peh, W. Y. X., Raczkowska, M. N., Teh, Y., Alam, M., Thakor, N. V., & Yen, S.-C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aadee9 · Cited by 15
“There have been several studies trying to engineer implantable ways to determine bladder state indirectly from neural activity, including high-density penetrating microelectrode arrays [83] and recording microchannel electrode [34] in dorsal root ganglia.”
BackgroundA Nonparametric Stochastic Optimizer for TDMA-Based Neuronal Signaling
Suzuki, J., Phan, D. H., & Budiman, H. (2014) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2014.2355015 · Cited by 14
Sabetian, P., & Yoo, P. B. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5551 · Cited by 14
“As recently shown by Chew et al [51], distinct neural signals may be recorded with 100 myelinated nerve fibers firing within a 100 μm2 channel.”
Metcalfe, B., Chew, D. J., Clarke, C., Donaldson, N., & Taylor, J. T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944166 · Cited by 14
Self-citationEthical Implications of Sensory Prostheses
Hansson, S. O. (2014) · Springer eBooks · doi:10.1007/978-94-007-4707-4_46 · Cited by 15
Cho, Y., Shin, H., Park, J., & Lee, S. (2021) · Micromachines · doi:10.3390/mi12060720 · Cited by 14
“In addition, a therapeutic alternative method for the neurogenic bladder has been suggested through the modulation of the bladder nerves including the parasympathetic nervous system (PSNS) [5,6].”
MethodMicrochannel neural interface manufacture by stacking silicone and metal foil laminae
Lancashire, H. T., Vanhoestenberghe, A., Pendegrass, C. J., Ajam, Y. A., Magee, E., Donaldson, N., & Blunn, G. W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/034001 · Cited by 13
“studies showing MNI devices with 20 [3, 7], 10 [12], 8 [6, 9], 5 [13], and 4 [31] microchannels containing electrodes.”
BackgroundMethodInfluentialSelf-citationArray profiling reveals contribution of Cthrc1 to growth of the denervated rat urinary bladder
Zhu, B., Ekman, M., Svensson, D., Lindvall, J. M., Nilsson, B., Uvelius, B., & Swärd, K. (2018) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00499.2017 · Cited by 12
“Denervation of the urinary bladder occurs after trauma and surgery and in diabetes (8, 9).”
BackgroundActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“Activation of motor regions is another use of peripheral nerve interfaces to manage respiratory ventilation and urinary incontinence, correct foot drop, and restore or achieve control of prosthetic limbs with tactile feedback [8], [9], [10].”
Long-term implantable flexible neural interfaces for electrophysiological monitoring
Chen, B., Lu, J., Chen, Z., Han, X., Sun, Y., Lin, X., Tang, Z., Jia, S., Xie, G., Huo, F., et al. (2025) · Journal of Materials Chemistry C · doi:10.1039/d4tc04289a · Cited by 10
Effect of Engineered Cyanobacterial Capsules on a Neurogenic Bladder after Spinal Cord Injury
Xiao, Y., He, Y., Zhong, D., Liu, B., Tang, Z., Lan, X., Dong, Y., Du, H., Liu, Y., & Luo, J. F. (2025) · ACS Nano · doi:10.1021/acsnano.4c14140 · Cited by 10
Hybrid Bionic Nerve Interface for Application in Bionic Limbs
Cho, Y., Jeong, H. H., Shin, H., Pak, C. J., Cho, J., Kim, Y., Kim, D.-G., Kim, T. K., Kim, H., Kim, S., et al. (2023) · Advanced Science · doi:10.1002/advs.202303728 · Cited by 11
Rajneesh, C. P., Lai, C., Chen, S.-C., Hsieh, T.-H., Chin, H., & Peng, C. (2018) · International Urology and Nephrology · doi:10.1007/s11255-018-2028-1 · Cited by 10
A Review on Bio-Cyber Interfaces for Intrabody Molecular Communications SystemsPreprint
Koucheryavy, Y. A., Yastrebova, A., Martins, D. P., & Balasubramaniam, S. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2104.14944 · Cited by 13
“For example, a neuroprosthesis (with the size of 100 µ m × 100 µ m × 3 mm) was proposed for bladder control [73].”
Xie, Y., Qin, P., Guo, T., Abed, A. A., Lovell, N. H., & Tsai, D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/aced20 · Cited by 8
2D Carbon Material‐Based Bio‐Abiotic Interfaces
Du, H., Chen, W., Kong, X., & Wen, L. (2025) · Small Methods · doi:10.1002/smtd.202500662 · Cited by 8
Graphene-based Flexible and Stretchable Bioelectronics in Health Care Systems
Kumar, V. (2016) · Journal of Analytical & Pharmaceutical Research · doi:10.15406/japlr.2016.03.00053 · Cited by 6
“As results, in short period of time, the market size of health care gadgets is significantly increased with further expectations of more improved medical devices [3].”
BackgroundDesign of integrated neural stimulating and recording frontend for bladder control prosthesis
Tao, W., Li, F. R., Wang, C., Tu, G., Wang, Z., & Lü, X. (2017) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-017-0962-y · Cited by 6
“have showed that the ENG correlated to bladder state can be obtained by implanting nerve rootlets into microchannels [39].”
BackgroundRen, J., Chew, D. J., & Thiruchelvam, N. (2016) · Urologia Internationalis · doi:10.1159/000444591 · Cited by 6
Self-citationBeach, S. J., Grundeen, S., Doyle, A. M., & Theogarajan, L. S. (2020) · Engineering Research Express · doi:10.1088/2631-8695/ab407e · Cited by 6
An Active Microchannel Neural Interface with Artifact Reduction
Habibollahi, M., Hanzaee, F. F., Jiang, D., Lancashire, H., & Demosthenous, A. (2021) · 2021 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas51556.2021.9401318 · Cited by 5
“This proves a sufficiently fast response for artifacts with frequencies as high as 20 kHz, which are used to block nerve conduction [12].”
BackgroundBladder pressure encoding by sacral dorsal root ganglion fibres: implications for decoding
Lubba, C. H., Ouyang, Z., Jones, N. S., Bruns, T. M., & Schultz, S. R. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcb14 · Cited by 5
“Targeting these nerves, however, requires a difficult surgery and recordings using the common cuff interface often lack good signal-to-noise ratio (SNR) without severely damaging the nerve [50].”
BackgroundTowards a Chipless and Wireless Passive System for Real‐Time Encoding of the Bladder Volume
Melloni, F., Bonacchini, G. E., Lanzani, G., & Caironi, M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000389 · Cited by 5
Delivopoulos, E., Shakesheff, K. M., & Peto, H. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319153 · Cited by 7
Self-citationJung, W., Jung, S., Kim, O., Park, H., Choi, W., Son, D., Chung, S. H., & Kim, J. (2019) · Micromachines · doi:10.3390/mi10030184 · Cited by 5
Metcalfe, B., Hunter, A. J., Graham-Harper-Cater, J., & Taylor, J. T. (2020) · Data in Brief · doi:10.1016/j.dib.2020.106561 · Cited by 5
Accessing the viscera: Technologies for interoception research
Pang, K. K. L., Mondal, R., Sahasrabudhe, A., & Anikeeva, P. (2025) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2025.103050 · Cited by 4
Neuronal signaling optimization for intrabody nanonetworks
Suzuki, J., Boonma, P., & Phan, D. H. (2014) · International Conference on Digital Information and Communication Technology and its Applications (DICTAP) · doi:10.1109/dictap.2014.6821659 · Cited by 4
“6= ∅ 1: v = 1 2: for each o ∈ O do 3: s = ∅ 4: for each n ∈ P do 5: if fo(n) fo(p) then 6: if s = ∅ then 7: s = n 8: else if fo(s) fo(n) then 9: s = n 10: end if 11: end if 12: end for 13: v = v × |fo(p)− fo(s)| 14: end for 15: return v”
Electrical/Spectroscopic Stability of Conducting and Biodegradable Graft‐Copolymer
Silva, A. C. D., Paschoal, V. H., Ribeiro, M. C. C., & de Torresi, S. I. C. (2022) · Macromolecular Chemistry and Physics · doi:10.1002/macp.202200275 · Cited by 4
Chronic infection of a Brindley sacral nerve root stimulator
Bramall, A. N., Chaudhary, B. R., Ahmad, J., & Shamji, M. F. (2016) · BMJ Case Reports · doi:10.1136/bcr-2015-213249 · Cited by 4
Closed-Loop Bladder Neuromodulation Therapy in Spinal Cord Injury Rat Model
Raczkowska, M. N., Peh, W. Y. X., Teh, Y., Alam, M., Yen, S., & Thakor, N. V. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717001 · Cited by 4
“A feedback control approach for bladder emptying has been demonstrated to be feasible in the rat model [8, 9], but the stimulation amplitudes and durations were non-adaptive”
BackgroundAn implantable ENG detector with in-system velocity selective recording (VSR) capability
Clarke, C., Rieger, R., Schüettler, M., Donaldson, N., & Taylor, J. T. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1567-9 · Cited by 4
“microchannels [2]) have impedances as Fig.”
Self-citationPrager, J., Metcalfe, B., Sadrafshari, S., Taylor, J. T., Donaldson, N., & Granger, N. P. (2024) · American Journal of Veterinary Research · doi:10.2460/ajvr.24.06.0173 · Cited by 3
Self-citationNeuroprosthetics for SCI Bladder Management: The Argument for Direct Bladder Stimulation
Walter, J. S. (2014) · International Journal of Physical Medicine & Rehabilitation · doi:10.4172/2329-9096.1000230 · Cited by 3
“Bilateral pudendal nerves also had wire electrodes sutured to them [16-22].”
BackgroundMechanically Compliant Neural Interfaces
Minev, I. R., & Lacour, S. P. (2016) · Microsystems and nanosystems · doi:10.1007/978-3-319-28694-5_13 · Cited by 3
“Our laboratory has demonstrated that roots housed in the soft channels continue to support healthy axons and vasculature after chronic implantation in rats [10].”
BackgroundSelf-citationA Review on Neural Amplifier Design for Brain–Machine Interface
Nath, S., Guha, K., & Baishnab, K. L. (2023) · Lecture notes in electrical engineering · doi:10.1007/978-981-99-4495-8_28 · Cited by 3
Suzuki, J., & Boonma, P. (2014) · Genetic and Evolutionary Computation Conference Companion (GECCO Companion) · doi:10.1145/2598394.2609854 · Cited by 3
Implementing MEMS technology for soft, (bio)electronics interfaces
Romeo, A., Hofmeister, Y., & Lacour, S. P. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2051173 · Cited by 3
Self-citationKlus, J., Boys, A. J., Serrano, R. R., Malliaras, G. G., & Carnicer‐Lombarte, A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae0c3b · Cited by 2
“Within nerves, single spike detection has been reported in both penetrating intra-fascicular device designs [42–44] as well as non-penetrating channel [9, 31, 45], paddle [46], and cuff designs [10, 12, 47–50].”
InfluentialClosed-Loop Visceral Bioelectronics Therapies
Raczkowska, M. N., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_118 · Cited by 2
Umansky, D., Elzinga, K. E., & Midha, R. (2024) · Handbook of clinical neurology · doi:10.1016/b978-0-323-90108-6.00012-0 · Cited by 2
Ramped kilohertz-frequency signals produce nerve conduction block without onset response
Peña, E., Pelot, N. A., & Grill, W. M. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/add20e · Cited by 2
“Reversible peripheral nerve block using kilohertz-frequency (KHF) electrical signals has substantial potential to treat conditions such as bladder dysfunction (Chew et al 2013, Peh et al 2018), heart failure (Buckley et al 2017), inflammatory disorders (Patel et al 2017), and pain-related disorders.”
Neural signal processing for closed-loop neuromodulation
Cha, K. S., Yeo, D., & Kim, K. H. (2016) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0231-5 · Cited by 2
“Neurogenic bladder SUA (spinal cord sensory nerves) Electrical stimulation (Spinal cord) firing rate of SUA correlated with bladder filling rats [70]”
Background
Metadata
- Authors
- Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., & Fawcett, J. W.
- Affiliations
- University of Cambridge (GB)
- King's College London (GB)
- University of Reading (GB)
- École Polytechnique Fédérale de Lausanne (CH)
- University College London (GB)
- Department of Medical Physics and Bioengineering, University College London, London WC1E 6BT, UK.
- Corresponding author
- Chew, Daniel J.
- Zhu, Lan
- ORCID
- Venue
- Science Translational Medicine
- Published
- 2013-11-06
- Volume
- 5
- Issue
- 210
- Pages
- 210ra155-210ra155
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2016920038
- Cited by
- 123
- References
- 56
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 9 · 2023: 7 · 2022: 6 · 2021: 10 · 2020: 12 · 2019: 14 · 2018: 14 · 2017: 12 · 2016: 12 · 2015: 9 · 2014: 10 · 2013: 1
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- DMU Open Research Archive (De Montfort University) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Portal (King's College London) (submittedVersion)
- Funders
- Christopher and Dana Reeve Foundation
- Fondation Bertarelli
- Acorda Therapeutics
- National Institute for Health and Care Research
- Novartis Pharma
- Engineering and Physical Sciences Research Council (EP/H00727X/1)
- Topics
- Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- neurogenic bladder, spinal cord injury, dorsal root stimulation, ventral root stimulation, detrusor-sphincter dyssynergia, sensory feedback, rat model
- MeSH terms
- Action Potentials, Animals, Axons, Urinary Bladder, Electric Stimulation, Female, Microelectrodes, Myelin Sheath, Nerve Block, Organ Size, Prosthesis Design, Spinal Cord Injuries, Spinal Nerve Roots, Urination, Rats, Sprague-Dawley, Implants, Experimental, Rats, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.