A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
An electronic interface for recording and stimulating nerves that innervate the bladder helps to restore normal bladder function in rats with spinal cord injury.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the severe implantation trauma caused by the full dissection of the epineurium can lead to axon damage, certain nerves are able to support this implantation procedure (Chew et al., 2013).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Chew et al., 2013
In the citing paper
“Microchannels were implanted on the dorsal surface of the S1-S2 spinal cord for feedback control of bladder functions [Fig.4(j)] 110”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [110]
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · cited 1×
“Regaining bladder control is among the principal desires of patients presenting with spinal cord injury (4).”
BackgroundThe neural control of micturition
Fowler, C. J., Griffiths, D., & de Groat, W. C. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2401 · Cited by 1,485 · cited 1×
“Normal micturition depends on coordinated bladder contraction and sphincter relaxation controlled by the lumbosacral neuronal circuitry, and is initiated and inhibited by descending control from the brainstem (1, 2).”
BackgroundConduction velocity is related to morphological cell type in rat dorsal root ganglion neurones.
Harper, A. A., & Lawson, S. N. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015573 · Cited by 745 · cited 1×
“25m/s, suggesting that Aa-b axons predominate in the compound action potential, with slower unit activity falling within the range of thinly myelinated Ad and C axons, in accordance with published literature on primary afferent classification (37, 38).”
ResultThe first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313
Sengupta, J. N., & Gebhart, G. F. (1994) · Journal of Neurophysiology · doi:10.1152/jn.1994.72.5.2420 · Cited by 246
High‐frequency electrical conduction block of mammalian peripheral motor nerve
Bhadra, N., & Kilgore, K. L. (2005) · Muscle & Nerve · doi:10.1002/mus.20428 · Cited by 239 · cited 1×
“This is an effective way to block conduction in the sciatic nerve (42) as well as ventral roots (43) and pudendal nerves (44) that innervate the urethral sphincter.”
BackgroundCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177 · cited 1×
“Together, these findings put in place the necessary tools to attempt a revision of the bladder control device initiated byBrindleymore than 30 years ago (5).”
Electrophysiological study of micturition reflexes in rats
Mallory, B., Steers, W. D., & De Groat, W. C. (1989) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1989.257.2.r410 · Cited by 169 · cited 2×
“In humans with full bladders, spontaneous voiding contractions occur every fewminutes, whereas in rats with a full bladder, we saw regular contractions about every 10 to 20 s, in accordance with previous data (34).”
BackgroundResultDynamic MRI of the pelvic floor muscles in an upright sitting position
B�, K., Lille�s, F., Talseth, T., & Hedland, H. (2001) · Neurourology and Urodynamics · doi:10.1002/1520-6777(2001)20:2<167::aid-nau19>3.0.co;2-4 · Cited by 160
Plasticity in reflex pathways to the lower urinary tract following spinal cord injury
de Groat, W. C., & Yoshimura, N. (2011) · Experimental Neurology · doi:10.1016/j.expneurol.2011.05.003 · Cited by 149 · cited 1×
“Slowly, an automatic micturition pattern can emerge from plasticity within the lumbosacral neuronal circuitry (3).”
BackgroundAfferent fibers supplying the uterus in the rat
Berkley, K. J., Robbins, A., & Sato, Y. (1988) · Journal of Neurophysiology · doi:10.1152/jn.1988.59.1.142 · Cited by 145 · cited 1×
“This has enabled the identification of specific sensory modalities of reflex bladder emptying and fullness from a mixed nerve root, which receives divergent sensory information from the skin, viscera, musculature, and reproductive system (40, 41).”
BackgroundNeural control of the female urethral and anal rhabdosphincters and pelvic floor muscles
Thor, K. B., & de Groat, W. C. (2010) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00111.2010 · Cited by 144 · cited 1×
“These spikes probably correspond to muscle spindle afferents innervating the pelvic floor and urethral sphincter such as the pubocaudalis and rhabosphincter (35).”
BackgroundBladder Inhibition by Penile Nerve Stimulation in Spinal Cord Injury Patients
Wheeler, J. S., Walter, J. S., & Zaszczurynski, P. J. (1992) · Journal of Urology · doi:10.1016/s0022-5347(17)37145-8 · Cited by 124
(1998) · PubMed · Cited by 107
Neuromodulation of the lower urinary tract
Craggs, M. D., & McFarlane, J. P. (1999) · Experimental Physiology · doi:10.1111/j.1469-445x.1999.tb00080.x · Cited by 100 · cited 1×
“The hypothesized mechanism for this particular “neuromodulation” is afferent-directed inhibition of detrusor muscle motor neurons (50).”
BackgroundSelf-citationA technique for anodally blocking large nerve fibres through chronically implanted electrodes.
Brindley, G. S., & Craggs, M. D. (1980) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.12.1083 · Cited by 94
Self-citationConduction velocity distribution of afferent fibers innervating the rat urinary bladder
Vera, P. L., & Nadelhaft, I. (1990) · Brain Research · doi:10.1016/0006-8993(90)91693-b · Cited by 86
Kirkham, A. P. S., Knight, S. L., Craggs, M. D., Casey, A. T. H., & Shah, P. J. R. (2002) · Spinal Cord · doi:10.1038/sj.sc.3101278 · Cited by 85 · cited 1×
“Noninvasive penile nerve stimulation has worked particularly well at suppressing bladder contractions in patients with spinal cord injury (47, 48), and the same benefit has been shown when SARS has been applied to extradural mixed or intradural posterior sacral roots (49).”
BackgroundSelf-citationRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Boger, A., Bhadra, N., & Gustafson, K. J. (2008) · Neurourology and Urodynamics · doi:10.1002/nau.20538 · Cited by 77 · cited 1×
“This is an effective way to block conduction in the sciatic nerve (42) as well as ventral roots (43) and pudendal nerves (44) that innervate the urethral sphincter.”
BackgroundJezernik, S., Grill, W. M., & Sinkjaer, T. (2001) · Neurourology and Urodynamics · doi:10.1002/1520-6777(2001)20:2<215::aid-nau23>3.0.co;2-0 · Cited by 77
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · cited 2×
“Tripolar microchannel electrodes suppress noise and increase the effective extracellular impedance in the vicinity of the electrodes, thereby amplifying the extracellular potential to hundreds of microvolts (28, 39).”
BackgroundSelf-citationLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
Self-citationFitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · cited 2×
“Microchannel implants were recorded initially by penetrating with tungsten electrodes (impedance 1 to 2 megohms at 1 kHz) (39).”
BackgroundSelf-citationDelivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · cited 2×
“The current study confirms our previous studies reporting that rootlets acutely confined within microchannel electrodes produce excellent SNR (30) and that a proportion carry bladder information (31).”
ResultSelf-citationAoyagi, Y., Stein, R. B., Branner, A., Pearson, K. G., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00143-2 · Cited by 68
Monitoring of renal function in patients with spinal cord injury
MacDiarmid, S., McIntyre, W. J., Anthony, A., Bailey, R. R., Turner, J. G., & Arnold, E. P. (2000) · British Journal of Urology · doi:10.1046/j.1464-410x.2000.00680.x · Cited by 64
Nance, D. M., Burns, J., Klein, C. M., & Burden, H. W. (1988) · Brain Research Bulletin · doi:10.1016/0361-9230(88)90211-0 · Cited by 63
Bladder Inhibition by Penile Electrical Stimulation
Nakamura, M., & Sakurai, T. (1984) · British Journal of Urology · doi:10.1111/j.1464-410x.1984.tb05833.x · Cited by 62 · cited 1×
“Noninvasive penile nerve stimulation has worked particularly well at suppressing bladder contractions in patients with spinal cord injury (47, 48), and the same benefit has been shown when SARS has been applied to extradural mixed or intradural posterior sacral roots (49).”
BackgroundKurstjens, G. A. M., Borau, A., RODRÍGUEZ, A., Rijkhoff, N., & Sinkjær, T. (2005) · The Journal of Urology · doi:10.1097/01.ju.0000173005.70269.9c · Cited by 59
Possover, M., Schurch, B., & Henle, K.-P. (2010) · Neurourology and Urodynamics · doi:10.1002/nau.20897 · Cited by 56 · cited 1×
“The latter technique enables micturition through an open sphincter, avoiding DSD, and has been effectively shown in a human patient (45).”
Malmstrom, J. A., McNaughton, T. G., & Horch, K. W. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.35 · Cited by 50
Bruns, T. M., Gaunt, R. A., & Weber, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056010 · Cited by 47
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46
Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
Bradley, R. M., Smoke, R. H., Akın, T., & Najafi, K. (1992) · Brain Research · doi:10.1016/0006-8993(92)91031-9 · Cited by 44
High frequency sacral root nerve block allows bladder voiding
Böger, A., Bhadra, N., & Gustafson, K. J. (2012) · Neurourology and Urodynamics · doi:10.1002/nau.21075 · Cited by 43 · cited 2×
“The bilateral L6 ventral roots were placed within a tungsten foil electrode cuff (43).”
BackgroundMethodLoeb, G. E. (1976) · Brain Research · doi:10.1016/0006-8993(76)90810-6 · Cited by 43 · cited 1×
“25m/s, suggesting that Aa-b axons predominate in the compound action potential, with slower unit activity falling within the range of thinly myelinated Ad and C axons, in accordance with published literature on primary afferent classification (37, 38).”
ResultChapter 15 Sensory-motor integration in urinary bladder function
McMahon, S. B. (1986) · Progress in brain research · doi:10.1016/s0079-6123(08)62766-1 · Cited by 40 · cited 1×
“Normal micturition depends on coordinated bladder contraction and sphincter relaxation controlled by the lumbosacral neuronal circuitry, and is initiated and inhibited by descending control from the brainstem (1, 2).”
BackgroundSelf-citationMinev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026005 · Cited by 36
Self-citationElectrical Stimulation of the Bladder and Gravidity
Magasi, P., & Simon, Z. (1986) · Urologia Internationalis · doi:10.1159/000281209 · Cited by 35 · cited 4×
“05] and 3-month nonrhizotomized [t(10) = 2.”
BackgroundInfluentialSadananda, P., Drake, M. J., Paton, J. F. R., & Pickering, A. E. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00062 · Cited by 28 · cited 1×
“org 6 No driven by spinal neural input (36).”
BackgroundPatient preferences for next generation neural prostheses to restore bladder function
Sanders, P. M. H., IJzerman, M. J., Roach, M. J., & Gustafson, K. J. (2011) · Spinal Cord · doi:10.1038/sc.2010.65 · Cited by 27 · cited 1×
“However, most of the patients with spinal cord injury would still prefer improved neural prostheses (13).”
BackgroundOptimal filtering of whole nerve signals
Jezernik, S., & Grill, W. M. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00334-x · Cited by 21 · cited 1×
“These include regenerative sieve electrodes (14–16) that require transection of a peripheral nerve for implantation, invasive penetrative arrays for intracellular recording from dorsal root ganglia (17–19), and cuff electrodes that wrap around intact sensory nerves and roots (20–23) but generally produce a poor SNR ev…”
BackgroundSchuettler, M., Seetohul, V., Rijkhoff, N. J. M., Moeller, F. V., Donaldson, N., & Taylor, J. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6090847 · Cited by 19
Self-citationUse of an Implanted Sacral Nerve Stimulator to Restore Urine Voiding in Chronically Paraplegic Dogs
Granger, N. P., Chew, D. J., Fairhurst, P. G., Fawcett, J. W., Lacour, S. P., Craggs, M. D., Mosse, C. A., Donaldson, N., & Jeffery, N. D. (2012) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12011 · Cited by 19 · cited 1×
“Recently, we have implanted several newly designed SARS devices into dogs, providing a good clinical solution for their incontinence (11).”
MethodSelf-citationGrünewald, V., Bhadra, N., Creasey, G. H., & Mortimer, J. T. (1998) · World Journal of Urology · doi:10.1007/s003450050076 · Cited by 16
Electronic Bladder Stimulation in Spinal Cord Paralysis
Magasi, P., Novoszel, T., & Koncz, P. (2010) · Urologia Internationalis · doi:10.1159/000280069 · Cited by 15
Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode
Schuettler, M., Seetohul, V., Taylor, J., & Donaldson, N. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260335 · Cited by 15 · cited 1×
“Techniques under development include velocity-selective recordings from multielectrode cuffs to generate a more detailed action potential profile (25, 26), but these currently require a very high sampling rate and detailed offline analysis (27).”
Self-citationSelective activation of the sacral anterior roots for induction of bladder voiding
Bhadra, N., Grünewald, V., Creasey, G. H., & Mortimer, J. T. (2005) · Neurourology and Urodynamics · doi:10.1002/nau.20184 · Cited by 14
Design of an Implant for Preventing Incontinence After Spinal Cord Injury
Donaldson, N., Perkins, T. A., Pachnis, I., Vanhoestenberghe, A., & Demosthenous, A. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2008.00606.x · Cited by 13 · cited 1×
“Bladder fullness may be determined by a frequency threshold of afferent activity in a subcutaneously dwelling “fullness monitor,” currently under development (55).”
BackgroundSelf-citationCho, K. H., & Lee, S. S. (2012) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2012.36.2.213 · Cited by 12 · cited 1×
“However, this entails loss of reflexive erectile function, loss of vaginal lubrication, and weakening of the pelvic floor muscles (8, 12).”
BackgroundFloyd, K., McMahon, S. B., & Jf, M. (1978) · PubMed · Cited by 12
Self-citationA summary of the theory of velocity selective neural recording
Taylor, J. T., Schüettler, M., Clarke, C., & Donaldson, N. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091151 · Cited by 10 · cited 1×
“Techniques under development include velocity-selective recordings from multielectrode cuffs to generate a more detailed action potential profile (25, 26), but these currently require a very high sampling rate and detailed offline analysis (27).”
BackgroundSelf-citationPopović, M. R. (2002) · Spinal Cord · doi:10.1038/sj.sc.3101342 · Cited by 8 · cited 1×
“To preserve sensory function for the patient (32), this implantation can be accomplished without cutting the root from the cord (rhizotomy).”
BackgroundImplanted Neuroprosthetic Devices
Brindley, G. S. (1982) · Stereotactic and Functional Neurosurgery · doi:10.1159/000101658 · Cited by 7
Cited by
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Self-citationTopological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Choi, S., Han, S. I., Kim, D., Hyeon, T., & Kim, D.-H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00706c · Cited by 591
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Such microchannel electrodes have, for example, been implanted in nerves at locations very proximal to the dorsal root ganglia to monitor bladder function in rodents at long-term implantation time points (Chew et al., 2013).”
BackgroundBioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Metadata
- Authors
- Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., & Fawcett, J. W.
- Affiliations
- University of Cambridge (GB)
- King's College London (GB)
- University of Reading (GB)
- École Polytechnique Fédérale de Lausanne (CH)
- University College London (GB)
- Department of Medical Physics and Bioengineering, University College London, London WC1E 6BT, UK.
- Corresponding author
- Chew, Daniel J.
- Zhu, Lan
- ORCID
- Venue
- Science Translational Medicine
- Published
- 2013-11-06
- Volume
- 5
- Issue
- 210
- Pages
- 210ra155-210ra155
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2016920038
- Cited by
- 123
- References
- 56
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 9 · 2023: 7 · 2022: 6 · 2021: 10 · 2020: 12 · 2019: 14 · 2018: 14 · 2017: 12 · 2016: 12 · 2015: 9 · 2014: 10 · 2013: 1
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- DMU Open Research Archive (De Montfort University) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Portal (King's College London) (submittedVersion)
- Funders
- Christopher and Dana Reeve Foundation
- Fondation Bertarelli
- Acorda Therapeutics
- National Institute for Health and Care Research
- Novartis Pharma
- Engineering and Physical Sciences Research Council (EP/H00727X/1)
- Topics
- Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- neurogenic bladder, spinal cord injury, dorsal root stimulation, ventral root stimulation, detrusor-sphincter dyssynergia, sensory feedback, rat model
- MeSH terms
- Action Potentials, Animals, Axons, Urinary Bladder, Electric Stimulation, Female, Microelectrodes, Myelin Sheath, Nerve Block, Organ Size, Prosthesis Design, Spinal Cord Injuries, Spinal Nerve Roots, Urination, Rats, Sprague-Dawley, Implants, Experimental, Rats, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.