An optical lattice clock with spin-polarized 87Sr atoms
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0→3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional uncertainty of 2.6×10-15, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy [Phys. Rev. Lett. 98, 083002 (2007)].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186
Optical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Quantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Single-Ion Nuclear Clock for Metrology at the 19th Decimal Place
Campbell, C. J., Radnaev, A. G., Kuzmich, A., Dzuba, V. A., Flambaum, V. V., & Derevianko, A. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.120802 · Cited by 347
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Optical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
Colloquium: Physics of optical lattice clocks
Derevianko, A., & Katori, H. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.331 · Cited by 253
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
“JILA07: [35]; SYRTE08: [36], JILA08: [37], UT09: [38], PTB11: [33], NICT-a 12: [39], NICT-b 12: [40], SYRTE 13: [29], PTB13: [30], NMIJ14: [31].”
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Self-citationOptical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
“ratio we previously reported in [8]. Right: the points for Cs of the left gure with the smallest statistical uncertainty are compared with similar measurement worldwide since 2006 (green : LNE-SYRTE [24, 8], red : JILA [25, 26], light blue : Tokyo University [27], orange : PTB [28, 10, 6], pink : NICT [27, 29, 30, 5],…”
BackgroundSelf-citationLong term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Self-citationIntermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
Metadata
- Authors
- Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, G. D., Laurent, P., Rosenbusch, P., Bize, S., Santarelli, G., Clairon, A., Lemonde, P., Grosche, G., Lipphardt, B., & Schnatz, H.
- Venue
- The European Physical Journal D
- Published
- 2007-12-07
- Volume
- 48
- Issue
- 1
- Pages
- 11-17
- ISSN
- 1434-6060 (ISSN-L)
- 1434-6079
- OpenAlex
- W2763613630
- Cited by
- 96
- References
- 5
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.