Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Open accessThe DOI matches its Crossref record; 93 of the 97 references it cites were found in a registry or an index.
Abstract
Raman and Infrared (IR) spectroscopies provide information about the structure, functional groups and environment of the molecules in the sample. In combination with a microscope, these techniques can also be used to study molecular distributions in heterogeneous samples. Over the past few decades Raman and IR microspectroscopy based techniques have been extensively used to understand fundamental biology and responses of living systems under diverse physiological and pathological conditions. The spectra from biological systems are complex and diverse, owing to their heterogeneous nature consisting of bio-molecules such as proteins, lipids, nucleic acids, carbohydrates etc. Sometimes minor differences may contain critical information. Therefore, interpretation of the results obtained from Raman and IR spectroscopy is difficult and to overcome these intricacies and for deeper insight we need to employ various data mining methods. These methods must be suitable for handling large multidimensional data sets and for exploring the complete spectral information simultaneously. The effective implementation of these multivariate data analysis methods requires the pretreatment of data. The preprocessing of raw data helps in the elimination of noise (unwanted signals) and the enhancement of discriminating features. This review provides an outline of the state-of-the-art data processing tools for multivariate analysis and the various preprocessing methods that are widely used in Raman and IR spectroscopy including imaging for better qualitative and quantitative analysis of biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Despite the wealth of information RS affords, the analysis and interpretation of experimental RS data remains a major challenge (37–39).”
From Hyperspectral unmixing for Raman spectroscopy via physics-constrained autoencoders (2024) · cites this paper as [39]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Statistics and Chemometrics for Analytical Chemistry
Miller, J. N., & Miller, J. C. (2005) · Cited by 3,783
Data Mining and Knowledge Discovery Handbook
(2010) · doi:10.1007/978-0-387-09823-4 · Cited by 2,190
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513 · cited 3×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodAutomated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049 · cited 1×
“For a simple Raman signal like a Raman spectrum of a non-fluorescent solid compound, a straight line fit through a couple of points could be sufficient enough, whereas for a complex Raman signal like a Raman spectrum of tissues/cells one might need many base points along with a fifth-order or higher polynomial fit [24…”
BackgroundAutomated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630 · cited 1×
“thresholds of a classification model [9, 38, 68, 95].”
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507 · cited 1×
“Hence, it is called extended MSC [48, 49].”
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475 · cited 1×
“mechanism of disease progression [66–69].”
Near‐infrared Raman spectroscopy for the classification of epithelial pre‐cancers and cancers
Stone, N., Kendall, C., Shepherd, N., Crow, P., & Barr, H. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.882 · Cited by 472 · cited 1×
“This is done by dividing the original data set into a training and a validation dataset, where the training set is used for learning the parameters and the validation set is used for evaluating the performance of the classification technique [72, 93, 94].”
MethodReal-time Raman Spectroscopy for In Vivo Skin Cancer Diagnosis
Lui, H., Zhao, J., McLean, D., & Zeng, H. (2012) · Cancer Research · doi:10.1158/0008-5472.can-11-4061 · Cited by 429 · cited 1×
“performed principal component with general discriminant analysis (PC-GDA) and PLS on Raman spectroscopic data to distinguish malignant from benign skin lesions with good diagnostic accuracy [91].”
MethodChemometrics in Analytical Spectroscopy
Adams, M. J. (2004) · Royal Society of Chemistry eBooks · doi:10.1039/9781847550484 · Cited by 423 · cited 2×
“Basic concepts and definitions The basic definitions pertaining to statistical analysis are important when dealing with more complex multivariate data structures [19–21].”
BackgroundApplications of Infrared, Raman, and Resonance Raman Spectroscopy in Biochemistry
Parker, F. S. (1983) · Medical Entomology and Zoology · Cited by 417
Imaging of colorectal adenocarcinoma using FT-IR microspectroscopy and cluster analysis
Lasch, P., Haensch, W., Naumann, D., & Diem, M. (2004) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2003.12.006 · Cited by 405 · cited 2×
“Then, the optimal number of “K” was chosen by comparing the KMCA clustered images with histopathological images [82].”
MethodSpectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353 · cited 5×
“Although there are many comprehensive studies available in the literature [22, 30, 46] on optimal preprocessing steps, the art of preprocessing is yet to be standardized.”
BackgroundMethodInfluentialChemometrics in spectroscopy. Part 1. Classical chemometrics
Geladi, P. (2003) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(03)00037-5 · Cited by 343
Raman Spectroscopy for Monitoring Protein Structure in Muscle Food Systems
Herrero, A. M. (2008) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408390701537385 · Cited by 330 · cited 1×
“[1–8].”
van Manen, H.-J., Kraan, Y. M., Roos, D., & Otto, C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502746102 · Cited by 322 · cited 2×
“Here, different clustering techniques can be used to segment out the cell region from the non-cell region [42, 43].”
BackgroundMethodInvestigation of Selected Baseline Removal Techniques as Candidates for Automated Implementation
Schulze, G., Jirasek, A., Yu, M. M. L., Lim, A., Turner, R. F. B., & Blades, M. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053945985 · Cited by 315 · cited 4×
“After thresholding (removing) the baseline, the corrected Raman signal can be obtained by the Inverse Wavelet Transform [30, 37].”
BackgroundMethodInfluentialAn intelligent background‐correction algorithm for highly fluorescent samples in Raman spectroscopy
Zhang, Z., Chen, S., Liang, Y., Liu, Z., Zhang, Q., Ding, L., Ye, F., & Zhou, H. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2500 · Cited by 308 · cited 3×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodDisease recognition by infrared and Raman spectroscopy
Krafft, C., Steiner, G., Beleites, C., & Salzer, R. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810024 · Cited by 285 · cited 1×
“mechanism of disease progression [66–69].”
How to pre-process Raman spectra for reliable and stable models?
Bocklitz, T., Walter, A., Hartmann, K., Rösch, P., & Popp, J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.043 · Cited by 282 · cited 4×
“and also to enhance subtle differences between different samples [22, 23].”
BackgroundMethodInfluentialMolckovsky, A., Song, L.-M. W. K., Shim, M. G., Marcon, N. E., & Wilson, B. C. (2003) · Gastrointestinal Endoscopy · doi:10.1067/mge.2003.105 · Cited by 265 · cited 1×
“This is done by dividing the original data set into a training and a validation dataset, where the training set is used for learning the parameters and the validation set is used for evaluating the performance of the classification technique [72, 93, 94].”
MethodRösch, P., Harz, M., Schmitt, M., Peschke, K.-D., Ronneberger, O., Burkhardt, H., Motzkus, H.-W., Lankers, M., Hofer, S., Thiele, H., et al. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.3.1626-1637.2005 · Cited by 265 · cited 1×
“In vibrational spectroscopy many studies have already been conducted using SVM as the classifier [38, 78–80].”
MethodBonnier, F., & Byrne, H. J. (2012) · The Analyst · doi:10.1039/c1an15821j · Cited by 237 · cited 1×
“These spectra are used for the assignment of the most important variables (bands) contributing to the structural part of the data matrix [60–63].”
MethodMohlenhoff, B., Romeo, M., Diem, M., & Wood, B. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057950 · Cited by 236 · cited 1×
“[26, 27].”
Mosier-Boss, P. A., Lieberman, S. H., & Newbery, R. (1995) · Applied Spectroscopy · doi:10.1366/0003702953964039 · Cited by 221 · cited 1×
“The baseline corrected Raman signal can be reconstructed by applying Inverse Fourier Transform (IFT) on these modified amplitudes [25, 30].”
MethodRaman spectroscopy and multivariate analysis of serum samples from breast cancer patients
Pichardo-Molina, J. L., Frausto-Reyes, C., Barbosa-García, O., Huerta-Franco, R., González-Trujillo, J. L., Ramírez-Alvarado, C. A., Gutiérrez-Juárez, G., & Medina-Gutiérrez, C. (2007) · Lasers in Medical Science · doi:10.1007/s10103-006-0432-8 · Cited by 212 · cited 1×
“These spectra are used for the assignment of the most important variables (bands) contributing to the structural part of the data matrix [60–63].”
MethodMolecular pathology via IR and Raman spectral imaging
Diem, M., Mazur, A., Lenau, K., Schubert, J., Bird, B., Miljković, M., Krafft, C., & Popp, J. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201300131 · Cited by 209 · cited 1×
“[1–8].”
Davis, R., & Mauer, L. J. (2014) · Cited by 198
Classification of colonic tissues using near-infrared Raman spectroscopy and support vector machines
Widjaja, E., Zheng, W., & Huang, Z. (2008) · International Journal of Oncology · doi:10.3892/ijo.32.3.653 · Cited by 193 · cited 1×
“The regression of one Y-variable is done on a set of independent X-variables using the Least Squares Criterion [78, 79].”
Method(2018) · Elsevier eBooks · doi:10.1016/c2020-0-01907-9 · Cited by 183
Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy
Berger, A. J., Itzkan, I., & Feld, M. S. (1997) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/s1386-1425(96)01779-9 · Cited by 183 · cited 1×
“to obtain experimentally [58, 78, 79, 88, 89].”
Discriminant Analysis of Raman Spectra for Body Fluid Identification for Forensic Purposes
Sikirzhytski, V., Virkler, K., & Lednev, I. K. (2010) · Sensors · doi:10.3390/s100402869 · Cited by 181 · cited 1×
“This is done by dividing the original data set into a training and a validation dataset, where the training set is used for learning the parameters and the validation set is used for evaluating the performance of the classification technique [72, 93, 94].”
MethodLabel-Free Live-Cell Imaging with Confocal Raman Microscopy
Klein, K., Gigler, A. M., Aschenbrenner, T., Monetti, R., Bunk, W., Jamitzky, F., Morfill, G., Stark, R. W., & Schlegel, J. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2011.12.027 · Cited by 174 · cited 1×
“The K-means algorithm is the simplest and one of the most widely used clustering algorithms in vibrational spectroscopy [45, 47, 57].”
MethodMiljković, M., Chernenko, T., Romeo, M. J., Bird, B., Matthäus, C., & Diem, M. (2010) · The Analyst · doi:10.1039/c0an00042f · Cited by 167 · cited 1×
“Various multivariate methods (unsupervised) such as K-means Cluster Analysis (KMCA), Agglomerative Hierarchical Cluster Analysis (AHCA), Principal Component Analysis (PCA), Fuzzy C Means Cluster Analysis (FCMCA), Vertex Component Analysis (VCA), and Divisive Correlation Cluster Analysis (DCCA) are being widely used fo…”
MethodMahesh, S., Jayas, D. S., Paliwal, J., & White, N. D. G. (2015) · Food and Bioprocess Technology · doi:10.1007/s11947-014-1381-z · Cited by 161 · cited 1×
“There are some well known techniques such as "scree plots” and “percentage of variance explained” which are used to determine the optimal ’k’ [55, 56].”
MethodIR microspectroscopy: potential applications in cervical cancer screening
Walsh, M. J., German, M. J., Singh, M. N., Montagu-Pollock, H. M., Hammiche, A., Kyrgiou, M., Stringfellow, H. F., Paraskevaidis, E. A., Martin‐Hirsch, P. L., & Martin, F. L. (2006) · Cancer Letters · doi:10.1016/j.canlet.2006.03.019 · Cited by 152 · cited 1×
“[38, 41, 45, 47, 57–59].”
Noise and background removal in Raman spectra of ancient pigments using wavelet transform
Ramos, P. M., & Ruisánchez, I. (2005) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1370 · Cited by 148 · cited 1×
“After thresholding (removing) the baseline, the corrected Raman signal can be obtained by the Inverse Wavelet Transform [30, 37].”
MethodHeraud, P., Wood, B. R., Beardall, J., & McNaughton, D. (2006) · Journal of Chemometrics · doi:10.1002/cem.990 · Cited by 143 · cited 1×
“In vibrational spectroscopy FCMCA is often used for solving the soft clustering problem [73, 84, 87].”
MethodHyperspectral NIR image regression part I: calibration and correction
Burger, J. E., & Geladi, P. L. M. (2005) · Journal of Chemometrics · doi:10.1002/cem.938 · Cited by 138 · cited 1×
“Different local regression methods can be used to calculate intensities at a pre-defined common spectral axis using the intensities at an existing spectral axis [28].”
MethodEllis, D. I., Broadhurst, D., Clarke, S. J., & Goodacre, R. (2005) · The Analyst · doi:10.1039/b511484e · Cited by 117 · cited 1×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodNon‐invasive analysis of cell cycle dynamics in single living cells with Raman micro‐spectroscopy
Swain, R. J., Jell, G., & Stevens, M. M. (2008) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21720 · Cited by 115
Rapid determination of caffeine content in soft drinks using FTIR–ATR spectroscopy
Paradkar, M. M., & Irudayaraj, J. (2002) · Food Chemistry · doi:10.1016/s0308-8146(02)00116-4 · Cited by 111 · cited 1×
“to obtain experimentally [58, 78, 79, 88, 89].”
Geladi, P. L. M., Lindholm‐Sethson, B., Nyström, J., Lillhonga, T., Lestander, T. A., & Burger, J. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.06.009 · Cited by 111
Discrimination of human and animal blood traces via Raman spectroscopy
McLaughlin, G., Doty, K. C., & Lednev, I. K. (2014) · Forensic Science International · doi:10.1016/j.forsciint.2014.02.027 · Cited by 110 · cited 1×
“The applications range from forensics to medicinal research [90–92].”
BackgroundA combined FT-IR microscopy and principal component analysis on softwood cell walls
Hori, R., & Sugiyama, J. (2003) · Carbohydrate Polymers · doi:10.1016/s0144-8617(03)00013-4 · Cited by 107 · cited 1×
“These spectra are used for the assignment of the most important variables (bands) contributing to the structural part of the data matrix [60–63].”
MethodKrafft, C., Shapoval, L., Sobottka, S. B., Geiger, K. D., Schackert, G., & Salzer, R. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.05.001 · Cited by 99
Dupuy, N., Duponchel, L., Huvenne, J. P., Sombret, B., & Legrand, P. (1996) · Food Chemistry · doi:10.1016/0308-8146(95)00213-8 · Cited by 97 · cited 1×
“These spectra are used for the assignment of the most important variables (bands) contributing to the structural part of the data matrix [60–63].”
MethodGhita, A., Pascut, F. C., Mather, M. L., Sottile, V., & Notingher, I. (2012) · Analytical Chemistry · doi:10.1021/ac202994e · Cited by 88 · cited 1×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodKrafft, C., Sobottka, S. B., Geiger, K. D., Schackert, G., & Salzer, R. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0892-5 · Cited by 81 · cited 2×
“These background correction methods could be as simple as subtracting an offset (DC shift) or removing a piecewise constructed baseline by selecting a few points and joining those points through straight lines [44].”
BackgroundMethodA model-free algorithm for the removal of baseline artifacts
Friedrichs, M. (1995) · Journal of Biomolecular NMR · doi:10.1007/bf00208805 · Cited by 79 · cited 1×
“This series of median values is convolved with a Gaussian function to make sure the estimated baseline is free from sharp discontinuities [31].”
BackgroundDelimitation of squamous cell cervical carcinoma using infrared microspectroscopic imaging
Steller, W., Einenkel, J., Horn, L., Braumann, U., Binder, H., Salzer, R., & Krafft, C. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0124-4 · Cited by 78 · cited 2×
“In vibrational spectroscopy FCMCA is often used for solving the soft clustering problem [73, 84, 87].”
MethodMolecular Changes of Preclinical Scrapie Can Be Detected by Infrared Spectroscopy
Kneipp, J., Beekes, M., Lasch, P., & Naumann, D. (2002) · Journal of Neuroscience · doi:10.1523/jneurosci.22-08-02989.2002 · Cited by 77 · cited 2×
“ANN is also used to solve classification problems in the field of vibrational spectroscopy [76, 77].”
MethodAn integrated software system for processing, analyzing, and classifying Raman spectra
Reisner, L. A., Cao, A., & Pandya, A. K. (2010) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2010.09.011 · Cited by 71 · cited 1×
“Sometimes, chemometrics itself assists in data pre-processing, to reduce and correct for interferences such as overlapping bands, baseline drifts, scattering and mainly to analyze spectral variations [17, 18].”
BackgroundDistinguishing and grading human gliomas by IR spectroscopy
Steiner, G. R., Shaw, A., Choo, L.-P., Abu-Id, M. H., Schackert, G., Sobottka, S. B., Steller, W., Salzer, R., & Mantsch, H. H. (2003) · Biopolymers · doi:10.1002/bip.10487 · Cited by 70 · cited 1×
“In the new dimensional space, each observation would have fewer variables (dimensionality reduction) and at the same time observations belonging to the same class will form lumps (clusters) and each cluster would be clearly differentiated from the other [41, 70].”
BackgroundIR Spectral Imaging for Histopathological Characterization of Xenografted Human Colon Carcinomas
Wolthuis, R. W. F., Travo, A., Nicolet, C., Neuville, A., Gaub, M., Guénot, D., Ly, E., Manfait, M., Jeannesson, P., & Piot, O. (2008) · Analytical Chemistry · doi:10.1021/ac801191x · Cited by 68
Induction of Stress Granule-Like Structures in Vesicular Stomatitis Virus-Infected Cells
Dinh, P. X., Beura, L. K., Das, P. B., Panda, D., Das, A., & Pattnaik, A. K. (2012) · Journal of Virology · doi:10.1128/jvi.02305-12 · Cited by 67 · cited 1×
“The Raman image of HeLa cell was recorded 2 h after isolating from the media, which must have resulted in the formation of vesicles due to stress [86].”
BackgroundScale-based normalization of spectral data
Randolph, T. W. (2006) · Cancer Biomarkers · doi:10.3233/cbm-2006-23-405 · Cited by 66 · cited 4×
“where X and Y are two different clusters; NX,NY are the corresponding numbers of observations Ward’s Criterion: Here, at every step two clusters that yield a minimum increase in total within-cluster variance (which is similar to disparity of single cluster) are merged [39, 40, 43].”
BackgroundMethodInfluentialClassification of fixed urological cells using Raman tweezers
Harvey, T. J., Hughes, C. S., Ward, A. D., Faria, E. C., Henderson, A., Clarke, N. W., Brown, M. D., Snook, R. D., & Gardner, P. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810061 · Cited by 66
Resonant Mie scattering (RMieS) correction applied to FTIR images of biological tissue samples
Bambery, K. R., Wood, B. R., & McNaughton, D. (2011) · The Analyst · doi:10.1039/c1an15628d · Cited by 64 · cited 1×
“[26, 27].”
Brudzewski, K., Kęsik, A., Kołodziejczyk, K., Zborowska, U., & Ulaczyk, J. (2005) · Fuel · doi:10.1016/j.fuel.2005.07.019 · Cited by 64 · cited 1×
“The regression of one Y-variable is done on a set of independent X-variables using the Least Squares Criterion [78, 79].”
MethodPodshyvalov, A., Sahu, R. K., Mark, S., Kantarovich, K., Guterman, H., Goldstein, J., Ramesh, J., Argov, S., & Mordechai, S. (2005) · Applied Optics · doi:10.1364/ao.44.003725 · Cited by 58 · cited 1×
“ANN is also used to solve classification problems in the field of vibrational spectroscopy [76, 77].”
MethodChemometrics, why, what and where to next?
Wold, S. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80183-a · Cited by 56 · cited 1×
“Multivariate analysis tools are used for the efficient processing of huge datasets and to align their informative features [13, 14].”
MethodFTIR imaging for the characterization of controlled-release drug delivery applications
Rafferty, D. W., & Koenig, J. L. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00135-9 · Cited by 55 · cited 1×
“[1–8].”
BLOUT, E. R., & Fields, M. (1949) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)56963-5 · Cited by 54
Application of vibrational microspectroscopy to biology and medicine
Singh, B., Gautam, R., Kumar, S., KUMAR, B., Nongthomba, U., Nandi, D., Mukherjee, G., Santosh, V., Somasundaram, K., & Umapathy, S. (2012) · NOT FOUND REPOSITORY (Indian Institute of Science Bangalore) · Cited by 54
Self-citationSoares, J. S., Barman, I., Dingari, N. C., Volynskaya, Z. I., Liu, W. J., Klein, N., Plecha, D. M., Dasari, R. R., & Fitzmaurice, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1215473110 · Cited by 54 · cited 1×
“This is used in evaluating the supervised classifier to understand its behavior when purposefully wrong labels are fed to the classification model [96].”
MethodKrafft, C., Diderhoshan, M. A., Recknagel, P., Miljković, M. D., Bauer, M. W., & Popp, J. (2010) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2010.09.003 · Cited by 53
Minor Distortions with Major Consequences: Correcting Distortions in Imaging Spectrographs
Esmonde-White, F. W. L., Esmonde‐White, K. A., & Morris, M. D. (2011) · Applied Spectroscopy · doi:10.1366/10-06040 · Cited by 52 · cited 1×
“Some modified multi-polynomial fitting based background correction techniques are proposed to handle these issues [34, 35].”
MethodAnalysis of Spectroscopic Imaging Data by Fuzzy C-Means Clustering
Mansfield, J. R., Sowa, M. G., Scarth, G. B., Somorjai, R. L., & Mantsch, H. H. (1997) · Analytical Chemistry · doi:10.1021/ac970206r · Cited by 49 · cited 1×
“In vibrational spectroscopy FCMCA is often used for solving the soft clustering problem [73, 84, 87].”
MethodBarrett, T. W., Peticolas, W. L., & Robson, R. M. (1978) · Biophysical Journal · doi:10.1016/s0006-3495(78)85454-x · Cited by 48 · cited 1×
“Here, a simple thresholding algorithm is applied to the data set consisting of Raman spectra [10] using PC1 and PC2 to demonstrate the outlier removal method.”
MethodDeming, S. N. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.9.1702 · Cited by 47 · cited 7×
“The application of multivariate statistical methods to chemistry and biology is also called Chemometrics [12].”
MethodInfluentialHartsuiker, L., Zeijen, N. J. L., Terstappen, L. W. M. M., & Otto, C. (2010) · The Analyst · doi:10.1039/c0an00524j · Cited by 47 · cited 3×
“where X and Y are two different clusters; NX,NY are the corresponding numbers of observations Ward’s Criterion: Here, at every step two clusters that yield a minimum increase in total within-cluster variance (which is similar to disparity of single cluster) are merged [39, 40, 43].”
BackgroundMethodMuik, B., Lendl, B., Molina‐Díaz, A., Ortega‐Calderón, D., & Ayora‐Cañada, M. J. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf049240e · Cited by 45 · cited 1×
“In spite of this, SIMCA has been applied successfully to spectroscopic data to solve many classification problems [72–75].”
MethodRaman Spectroscopic Studies on Screening of Myopathies
Gautam, R., Vanga, S., Madan, A., Gayathri, N., Nongthomba, U., & Umapathy, S. (2015) · Analytical Chemistry · doi:10.1021/ac503647x · Cited by 45
Self-citationAn Improved Algorithm to Remove Cosmic Spikes in Raman Spectra for Online Monitoring
Li, S., & Dai, L. (2011) · Applied Spectroscopy · doi:10.1366/10-06169 · Cited by 42 · cited 1×
“Usually, local interpolation based methods are used to repair spike affected regions [29].”
MethodO’Connell, M.-L., Ryder, A. G., Léger, M. N., & Howley, T. (2010) · Applied Spectroscopy · doi:10.1366/000370210792973541 · Cited by 40 · cited 1×
“The multivariate statistical methods are very useful for processing of Raman and IR spectral data because of their ability to analyze the vast spectral distribution and thoroughly discriminate between spectra of different samples that show only very minor changes [15, 16].”
MethodAPPLICATION OF INFRARED SPECTROSCOPY AND CHEMOMETRIC METHODS TO IDENTIFICATION OF SELECTED MINERALS
Ritz, M., Vaculíková, L., & Plevová, E. (2011) · ASEP · Cited by 40
Infrared microspectroscopic imaging of benign breast tumor tissue sections
Fabian, H., Lasch, P., Boese, M., & Haensch, W. (2003) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2003.07.002 · Cited by 38 · cited 1×
“is the most popular technique for chemical (Raman and IR) imaging [39, 40, 77, 84, 85].”
MethodHorton, R. B., Duranty, E., McConico, M., & Vogt, F. (2011) · Applied Spectroscopy · doi:10.1366/10-06122 · Cited by 37 · cited 1×
“The multivariate statistical methods are very useful for processing of Raman and IR spectral data because of their ability to analyze the vast spectral distribution and thoroughly discriminate between spectra of different samples that show only very minor changes [15, 16].”
MethodRobust Smoothing Applied to White Noise and Single Outlier Contaminated Raman Spectra
Bussian, B. M., & Härdle, W. K. (1984) · Applied Spectroscopy · doi:10.1366/0003702844555629 · Cited by 36 · cited 4×
“where X and Y are two different clusters; NX,NY are the corresponding numbers of observations Ward’s Criterion: Here, at every step two clusters that yield a minimum increase in total within-cluster variance (which is similar to disparity of single cluster) are merged [39, 40, 43].”
BackgroundMethodInfluentialGautam, R., Subramanian, B. C., Deobagkar‐Lele, M., Rakshit, S., N., V. K. B., Umapathy, S., & Nandi, D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045521 · Cited by 36 · cited 1×
“[1–8].”
Self-citationDingari, N. C., Barman, I., Saha, A., McGee, S., Galindo, L. H., Liu, W. J., Plecha, D. M., Klein, N., Dasari, R. R., & Fitzmaurice, M. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200098 · Cited by 36 · cited 1×
“thresholds of a classification model [9, 38, 68, 95].”
Raman and mid-infrared spectroscopic imaging: applications and advancements
Gautam, R., Samuel, A., Sil, S., Chaturvedi, D., Dutta, A., Ariese, F., & Umapathy, S. (2015) · VU Research Portal · Cited by 31
Self-citationKorsakov, A. V., Жуков, В. П., & Vandenabeele, P. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3831-4 · Cited by 29
Molecular profiling of sepsis in mice using Fourier Transform Infrared Microspectroscopy
Gautam, R., Deobagkar‐Lele, M., Majumdar, S., Subramanian, B. C., Victor, E. S., Ahmed, S. M., Wadhwa, N., Verma, T., Kumar, S., Sundaresan, N. R., et al. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400089 · Cited by 23 · cited 1×
“[2, 9–11].”
Self-citationWinefordner, J. D., & Rutledge, M. J. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248566 · Cited by 20
Vandenabeele, P. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3872-8 · Cited by 15
Investigating the effects of Pentoxifylline on human breast cancer cells using Raman spectroscopy
Goel, P. N., Singh, S. P., Krishna, C. M., & Gude, R. (2014) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545815500042 · Cited by 13 · cited 1×
“There are some well known techniques such as "scree plots” and “percentage of variance explained” which are used to determine the optimal ’k’ [55, 56].”
MethodRSC Analytical Spectroscopy Series
Royal Society of Chemistry (2011) · RSC analytical spectroscopy series/RSC analytical spectroscopy monographs · doi:10.1039/2041-9740 · Cited by 11
Data Acquisition and Analysis in Biomedical Vibrational Spectroscopy
Lasch, P., & Petrich, W. H. (2010) · Royal Society of Chemistry eBooks · doi:10.1039/9781849731997-00192 · Cited by 10 · cited 2×
“For example, in case of biological samples, the absorbance value of amide I (1620–1690 cm) can be considered as signal and the absorbance values in the dead region or signal free zone (1800–1900 cm) can be considered as noise (background) [46, 51].”
BackgroundFeasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy
Berger, A. (1997) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/s0584-8539(96)01779-5
Research works printed but not linked: 5
- 3. Gautam R, Samuel A, Sil S, Chaturvedi D, Dutta A, et al. Raman and Infrared Imaging: Applications and Advancements. Curr Sci. 2015;108:341-56.
- 21. Esbensen KH. Multivariate Data Analysis-in practice, 5 th Edition. CAMO; 2000.
- 23. Srinivasan GK. Vibrational Spectroscopic Imaging for Biomedical Applications, first edition. McGraw-Hill Professional; 2010.
- 36. Eilers PHC. Boelens HFM. Baseline correction with asymmetric least squares smoothing: Leiden University Medical Centre Report; 2005.
- 45. Bhargava R. Levin IW. Wiley-Blackwell: Spectroscopic Analysis using Infrared Multichannel Detectors; 2005.
Cited by
FTIR and Raman imaging for microplastics analysis: State of the art, challenges and prospects
Xu, J.-L., Thomas, K. V., Luo, Z., & Gowen, A. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115629 · Cited by 716
Peak Fitting Applied to Fourier Transform Infrared and Raman Spectroscopic Analysis of Proteins
Sadat, A., & Joye, I. J. (2020) · Applied Sciences · doi:10.3390/app10175918 · Cited by 557
“As a result, the spectra are scaled such, that the sum squared deviation over the indicated wavelengths equals one [35].”
BackgroundConvolutional neural networks for vibrational spectroscopic data analysis
Acquarelli, J., van Laarhoven, T., Gerretzen, J., Tran, T. N., Buydens, L. M. C., & Marchiori, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.010 · Cited by 472
“Preprocessing methods often depend on the objective of the study and on the technique (Raman or IR) used [8].”
MethodChallenges in application of Raman spectroscopy to biology and materials
Kuhar, N., Sil, S., Verma, T., & Umapathy, S. (2018) · RSC Advances · doi:10.1039/c8ra04491k · Cited by 334
“79 Di ff erent methods are available that help the user in deriving meaningful information from a complex spectral dataset.”
BackgroundSelf-citationWang, H.-P., Chen, P., Dai, J.-W., Liu, D., Li, J.-Y., Xu, Y.-P., & Chu, X.-L. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116648 · Cited by 326
Metadata
- Authors
- Gautam, R., Vanga, S., Ariese, F., & Umapathy, S.
- Affiliations
- Indian Institute of Science Bangalore (IN)
- Venue
- EPJ Techniques and Instrumentation
- Published
- 2015-06-02
- Volume
- 2
- Issue
- 1
- ISSN
- 2195-7045 (ISSN-L)
- OpenAlex
- W1563946068
- Cited by
- 696
- References
- 97
- Citations by year
- 2026: 53 · 2025: 88 · 2024: 91 · 2023: 65 · 2022: 99 · 2021: 89 · 2020: 79 · 2019: 45 · 2018: 39 · 2017: 33 · 2016: 13 · 2015: 2
- FWCI
- 17.55
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- EPJ Techniques and Instrumentation (publishedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Indian Institute of Science
- Department of Biotechnology, Ministry of Science and Technology, India
- Department of Science and Technology, Ministry of Science and Technology, India
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Raman spectroscopy, infrared spectroscopy, Raman imaging, infrared imaging, multivariate analysis, spectral preprocessing, biological specimen, spectral interpretation, noise reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.