Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Open accessThe DOI matches its Crossref record; 93 of the 97 references it cites were found in a registry or an index.
Abstract
Raman and Infrared (IR) spectroscopies provide information about the structure, functional groups and environment of the molecules in the sample. In combination with a microscope, these techniques can also be used to study molecular distributions in heterogeneous samples. Over the past few decades Raman and IR microspectroscopy based techniques have been extensively used to understand fundamental biology and responses of living systems under diverse physiological and pathological conditions. The spectra from biological systems are complex and diverse, owing to their heterogeneous nature consisting of bio-molecules such as proteins, lipids, nucleic acids, carbohydrates etc. Sometimes minor differences may contain critical information. Therefore, interpretation of the results obtained from Raman and IR spectroscopy is difficult and to overcome these intricacies and for deeper insight we need to employ various data mining methods. These methods must be suitable for handling large multidimensional data sets and for exploring the complete spectral information simultaneously. The effective implementation of these multivariate data analysis methods requires the pretreatment of data. The preprocessing of raw data helps in the elimination of noise (unwanted signals) and the enhancement of discriminating features. This review provides an outline of the state-of-the-art data processing tools for multivariate analysis and the various preprocessing methods that are widely used in Raman and IR spectroscopy including imaging for better qualitative and quantitative analysis of biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Despite the wealth of information RS affords, the analysis and interpretation of experimental RS data remains a major challenge (37–39).”
From Hyperspectral unmixing for Raman spectroscopy via physics-constrained autoencoders (2024) · cites this paper as [39]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Statistics and Chemometrics for Analytical Chemistry
Miller, J. N., & Miller, J. C. (2005) · Cited by 3,783
Data Mining and Knowledge Discovery Handbook
(2010) · doi:10.1007/978-0-387-09823-4 · Cited by 2,190
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513 · cited 3×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodAutomated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049 · cited 1×
“For a simple Raman signal like a Raman spectrum of a non-fluorescent solid compound, a straight line fit through a couple of points could be sufficient enough, whereas for a complex Raman signal like a Raman spectrum of tissues/cells one might need many base points along with a fifth-order or higher polynomial fit [24…”
BackgroundAutomated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630 · cited 1×
“thresholds of a classification model [9, 38, 68, 95].”
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507 · cited 1×
“Hence, it is called extended MSC [48, 49].”
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475 · cited 1×
“mechanism of disease progression [66–69].”
Research works printed but not linked: 5
- 3. Gautam R, Samuel A, Sil S, Chaturvedi D, Dutta A, et al. Raman and Infrared Imaging: Applications and Advancements. Curr Sci. 2015;108:341-56.
- 21. Esbensen KH. Multivariate Data Analysis-in practice, 5 th Edition. CAMO; 2000.
- 23. Srinivasan GK. Vibrational Spectroscopic Imaging for Biomedical Applications, first edition. McGraw-Hill Professional; 2010.
- 36. Eilers PHC. Boelens HFM. Baseline correction with asymmetric least squares smoothing: Leiden University Medical Centre Report; 2005.
- 45. Bhargava R. Levin IW. Wiley-Blackwell: Spectroscopic Analysis using Infrared Multichannel Detectors; 2005.
Cited by
FTIR and Raman imaging for microplastics analysis: State of the art, challenges and prospects
Xu, J.-L., Thomas, K. V., Luo, Z., & Gowen, A. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115629 · Cited by 716
Peak Fitting Applied to Fourier Transform Infrared and Raman Spectroscopic Analysis of Proteins
Sadat, A., & Joye, I. J. (2020) · Applied Sciences · doi:10.3390/app10175918 · Cited by 557
“As a result, the spectra are scaled such, that the sum squared deviation over the indicated wavelengths equals one [35].”
BackgroundConvolutional neural networks for vibrational spectroscopic data analysis
Acquarelli, J., van Laarhoven, T., Gerretzen, J., Tran, T. N., Buydens, L. M. C., & Marchiori, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.010 · Cited by 472
“Preprocessing methods often depend on the objective of the study and on the technique (Raman or IR) used [8].”
MethodChallenges in application of Raman spectroscopy to biology and materials
Kuhar, N., Sil, S., Verma, T., & Umapathy, S. (2018) · RSC Advances · doi:10.1039/c8ra04491k · Cited by 334
“79 Di ff erent methods are available that help the user in deriving meaningful information from a complex spectral dataset.”
BackgroundSelf-citationWang, H.-P., Chen, P., Dai, J.-W., Liu, D., Li, J.-Y., Xu, Y.-P., & Chu, X.-L. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116648 · Cited by 326
Cowger, W., Gray, A., Christiansen, S. H., DeFrond, H., Deshpande, A. D., Hemabessiere, L., Lee, E., Mill, L., Munno, K., Ossmann, B. E., et al. (2020) · Applied Spectroscopy · doi:10.1177/0003702820929064 · Cited by 302
“Using multivariate analytical tools, patterns in the data can be modeled and used to predict the newly acquired data of a similar type.(55,66,70) Some of the advanced methods for data processing used in Raman and IR spectroscopy include principal component analysis, linear discriminant analysis, multiple linear regres…”
MethodInfluentialRecent Progresses in Machine Learning Assisted Raman Spectroscopy
Qi, Y., Hu, D., Jiang, Y., Wu, Z., Zheng, M., Chen, E. X., Liang, Y., Sadi, M. A., Zhang, K., & Chen, Y. P. (2023) · Advanced Optical Materials · doi:10.1002/adom.202203104 · Cited by 250
Raman spectroscopy coupled with chemometrics for food authentication: A review
Xu, Y., Zhong, P., Jiang, A., Shen, X., Li, X., Xu, Z., Shen, Y., Sun, Y., & Lei, H. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116017 · Cited by 244
Krafft, C., Schmitt, M., Schie, I. W., Cialla‐May, D., Matthäus, C., Bocklitz, T., & Popp, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201607604 · Cited by 234
Evaluation of starch retrogradation by infrared spectroscopy
Lu, H., Ma, R., Chang, R., & Tian, Y. (2021) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2021.106975 · Cited by 233
Cultivation-Free Raman Spectroscopic Investigations of Bacteria
Lorenz, B., Wichmann, C., Stöckel, S., Rösch, P., & Popp, J. (2017) · Trends in Microbiology · doi:10.1016/j.tim.2017.01.002 · Cited by 212
Raman Spectroscopy: An Emerging Tool in Neurodegenerative Disease Research and Diagnosis
Devitt, G., Howard, K., Mudher, A., & Mahajan, S. (2018) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.7b00413 · Cited by 212
“As the loading plot of PC1 contains the Raman features responsible for the most variation between the spectra, further analysis enables the determination of the biological/chemical source of variation between different conditions.(44)”
BackgroundRaman spectroscopy: current applications in breast cancer diagnosis, challenges and future prospects
Hanna, K., Krzoska, E., Shaaban, A. M., Muirhead, D., Abu-Eid, R., & Speirs, V. (2022) · British Journal of Cancer · doi:10.1038/s41416-021-01659-5 · Cited by 198
“Principal component analysis (PCA) and Signal to noise ratio based thresholding methods are two examples of outlierdetection algorithms [20].”
MethodIn-vivo Raman spectroscopy: from basics to applications
Cordero, E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.7.071210 · Cited by 195
Levermore, J. M., Smith, T. E. L., Kelly, F. J., & Wright, S. L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05445 · Cited by 194
Plasmonic nanoparticle sensors: current progress, challenges, and future prospects
Kant, K., Beeram, R., Cao, Y., dos Santos, P. S. S., González-Cabaleiro, L., García-Lojo, D., Guo, H., Joung, Y., Kothadiya, S., Lafuente, M., et al. (2024) · Nanoscale Horizons · doi:10.1039/d4nh00226a · Cited by 182
Raman technologies in cancer diagnostics
Austin, L. A., Osseiran, S., & Evans, C. L. (2016) · The Analyst · doi:10.1039/c5an01786f · Cited by 182
A contemporary review on Data Preprocessing (DP) practice strategy in ATR-FTIR spectrum
Lee, L. C., Liong, C.-Y., & Jemain, A. A. (2017) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2017.02.008 · Cited by 178
Bruzas, I., Lum, W., Gorunmez, Z., & Sagle, L. B. (2018) · The Analyst · doi:10.1039/c8an00606g · Cited by 186
Raman microspectroscopy for microbiology
Lee, K. S., Landry, Z., Pereira, F. C., Wagner, M., Berry, D., Huang, W. E., Taylor, G. T., Kneipp, J., Popp, J., Zhang, M., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00075-6 · Cited by 161
Toward autonomous design and synthesis of novel inorganic materials
Szymanski, N. J., Zeng, Y., Huo, H., Bartel, C. J., Kim, H., & Ceder, G. (2021) · Materials Horizons · doi:10.1039/d1mh00495f · Cited by 159
Kim, S., Kim, T. G., Lee, S. H., Kim, W., Bang, A., Moon, S. W., Song, J. Y., Shin, J., Yu, J. S., & Choi, S. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b19421 · Cited by 156
An Empirical Study on Raman Peak Fitting and Its Application to Raman Quantitative Research
Yuan, X., & Mayanovic, R. A. (2017) · Applied Spectroscopy · doi:10.1177/0003702817721527 · Cited by 156
Jermyn, M., Desroches, J., Aubertin, K., St‐Arnaud, K., Madore, W., Montigny, É. D., Guiot, M., Trudel, D., Wilson, B. C., Petrecca, K., et al. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/23/r370 · Cited by 165
Carlomagno, C., Bertazioli, D., Gualerzi, A., Picciolini, S., Banfi, P. I., Lax, A., Messina, E., Navarro, J., Bianchi, L. N. C., Caronni, A., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-84565-3 · Cited by 150
Raman Spectroscopy and Imaging in Bioanalytics
Cialla‐May, D., Krafft, C., Rösch, P., Deckert‐Gaudig, T., Frosch, T., Jahn, M., Pahlow, S., Stiebing, C., Meyer‐Zedler, T., Bocklitz, T. W., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03235 · Cited by 150
Kumar, S., Verma, T., Mukherjee, R., Ariese, F., Somasundaram, K., & Umapathy, S. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00540j · Cited by 145
Self-citationMultimodal Imaging Mass Spectrometry: Next Generation Molecular Mapping in Biology and Medicine
Neumann, E. K., Djambazova, K. V., Caprioli, R. M., & Spraggins, J. M. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00232 · Cited by 143
Forensic body fluid identification and differentiation by Raman spectroscopy
Muro, C. K., Doty, K. C., Fernandes, L. D. S., & Lednev, I. K. (2016) · Forensic Chemistry · doi:10.1016/j.forc.2016.06.003 · Cited by 132
Rolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126
“Depending on the spectroscopy method, different preprocessing steps are required to reach this objective [94].”
MethodA Comparison of PCA-LDA and PLS-DA Techniques for Classification of Vibrational Spectra
Lasalvia, M., Capozzi, V., & Perna, G. (2022) · Applied Sciences · doi:10.3390/app12115345 · Cited by 126
Fourier Transform Infrared Spectroscopy in Oral Cancer Diagnosis
Wang, R., & Wang, Y. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22031206 · Cited by 125
“Commonly used clustering and discriminant methods for FTIR spectroscopic data analysis include k-means, fuzzy c-means (FCM), hierarchical cluster analysis (HCA), k-nearest neighbors (KNN), support vector machines (SVM), soft independent modeling of class analogy (SIMCA), linear discriminant analysis (LDA), partial lea…”
BackgroundMethodInfluentialThe Use of Infrared Spectroscopy for the Quantification of Bioactive Compounds in Food: A Review
Johnson, J. B., Walsh, K. B., Naiker, M., & Ameer, K. (2023) · Molecules · doi:10.3390/molecules28073215 · Cited by 130
“The aim of this procedure is to remove spectroscopic artefacts from the measurement process, such as ra dom noise, scatter or baseline drift [19,20].”
MethodLee, W., Lenferink, A. T. M., Otto, C., & Offerhaus, H. L. (2019) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5770 · Cited by 123
Biochar N Content, Pools and Aromaticity as Affected by Feedstock and Pyrolysis Temperature
Paiva, I. D. O., de Morais, E. G., Jindo, K., & Silva, C. A. (2024) · Waste and Biomass Valorization · doi:10.1007/s12649-023-02415-x · Cited by 125
“The normalization procedure recommended by Gautam et al. [38] was applied to pre-process the dataset from each FTIR spectrum.”
Palencia, M. (2018) · Journal of Advanced Research · doi:10.1016/j.jare.2018.05.009 · Cited by 114
“ABSF is given by aN ¼ 13 Xwþ2 w aw amax ¼ 1 3 Xwþ2 w aN;w ð7Þ where w denotes the position of absorbance values.”
MethodInfluentialNagy, B., Petra, D., Galata, D. L., Démuth, B., Borbás, E., Marosi, G., Nagy, Z. K., & Farkas, A. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118464 · Cited by 119
Mokari, A., Guo, S., & Bocklitz, T. W. (2023) · Molecules · doi:10.3390/molecules28196886 · Cited by 114
“Exclusion works by detecting and removing these outliers from the dataset [16].”
BackgroundRaman Spectroscopy for Rapid Evaluation of Surgical Margins during Breast Cancer Lumpectomy
Zúñiga, W. C., Jones, V., Anderson, S. M., Echevarria, A., Miller, N. L., Stashko, C., Schmolze, D. B., Cha, P. D., Kothari, R., Fong, Y., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-51112-0 · Cited by 113
Markl, D., Warman, M., Dumarey, M., Bergman, E.-L., Folestad, S., Shi, Z., Manley, L. F., Goodwin, D., & Zeitler, J. A. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119353 · Cited by 123
FTIR spectroscopy in biomedical research: how to get the most out of its potential
Magalhães, S., Goodfellow, B. J., & Nunes, A. (2021) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2021.1946822 · Cited by 116
“The method used depends on the aim of the study: one can use vector, minimum-maximum, standard normal variate, peak or area normalization methods.([50]) For instance, if the aim of the study is to investigate quantitative differences in a given peak between different samples, normalization should not be performed to t…”
MethodGiechaskiel, B., & Clairotte, M. (2021) · Applied Sciences · doi:10.3390/app11167416 · Cited by 123
“Other processing of raw data (apodization) may be used to smoothen discontinuities at the beginning and end of the spectra, reduce, or eliminate noise [3,124].”
MethodLago, B. C., Silva, C. A., Melo, L. C. A., & de Morais, E. G. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.148762 · Cited by 109
Multi-metal, Multi-wavelength Surface-Enhanced Raman Spectroscopy Detection of Neurotransmitters
Moody, A. S., & Sharma, B. (2018) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.8b00020 · Cited by 102
Compositional assessment of bone by Raman spectroscopy
Ünal, M., Ahmed, R., Mahadevan-Jansen, A. M., & Nyman, J. S. (2021) · The Analyst · doi:10.1039/d1an01560e · Cited by 108
Khuat, T. T., Bassett, R., Otte, E. A., Grevis-James, A., & Gabryś, B. (2024) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2024.108585 · Cited by 108
RamanSPy: An Open-Source Python Package for Integrative Raman Spectroscopy Data Analysis
Georgiev, D., Pedersen, S. V., Xie, R., Fernández-Galiana, Á., Stevens, M. M., & Barahona, M. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00383 · Cited by 108
Single-Step Preprocessing of Raman Spectra Using Convolutional Neural Networks
Wahl, J., Sjödahl, M., & Ramser, K. (2020) · Applied Spectroscopy · doi:10.1177/0003702819888949 · Cited by 100
“3 In recent years methods based on multivariate analysis has become more common place in the realm of preprocessing.”
MethodBioanalytical Measurements Enabled by Surface-Enhanced Raman Scattering (SERS) Probes
Jamieson, L. E., Asiala, S. M., Gracie, K., Faulds, K., & Graham, D. (2017) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041557 · Cited by 106
Tuck, M., Blanc, L., Touti, R., Patterson, N. H., Nuffel, S. V., Villette, S., Taveau, J., Römpp, A., Brunelle, A., Lecomte, S., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04595 · Cited by 100
Breast Cancer Diagnosis by Surface-Enhanced Raman Scattering (SERS) of Urine
Moisoiu, V., Socaciu, A. I., Ştefancu, A., Iancu, Ș. D., Boros, I., Alecsa, C. D., Răchieriu, C., Chiorean, A. R., Eniu, D., Leopold, N., et al. (2019) · Applied Sciences · doi:10.3390/app9040806 · Cited by 93
“The need to perform first PCA and then LDA resides in the fact that LDA can be applied only when the number of variables is smaller than the number of samples in any group of the model [21].”
BackgroundRecent advances in low-frequency Raman spectroscopy for pharmaceutical applications
Bērziņš, K., Fraser‐Miller, S. J., & Gordon, K. C. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.120034 · Cited by 97
Li, D., Zhu, Z., & Sun, D. (2021) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2021.117498 · Cited by 94
Order-to-disorder transition due to entropy in layered and 2D carbides
Wyatt, B. C., Yang, Y., Michałowski, P. P., Parker, T., Morency, Y., Urban, F., Kadagishvili, G., Tanwar, M., Muhoza, S. P., Nemani, S. K., et al. (2025) · Science · doi:10.1126/science.adv4415 · Cited by 88
Rise of Raman spectroscopy in neurosurgery: a review
DePaoli, D. T., Lemoine, É., Ember, K. J. I., Parent, M., Prud’homme, M., Cantin, L., Petrecca, K., Leblond, F., & Côté, D. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.5.050901 · Cited by 86
“Opponents of band fitting for biological Raman signals argue that the selection of target bands cannot be reliable in the case of low SNR signal exhibiting a high number of potential peaks and that our knowledge of Raman generating processes in tissue is not strong enough to limit our analysis to a few critical bands.…”
BackgroundMethodLuo, Y., Zhang, X., Zhang, Z., Naidu, R., & Fang, C. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04498 · Cited by 84
Zadora, G., & Menżyk, A. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.04.009 · Cited by 87
Raman imaging from microscopy to macroscopy: Quality and safety control of biological materials
Lohumi, S., Kim, M. S., Qin, J., & Cho, B. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.06.002 · Cited by 91
Li, D., Zhu, Z., & Sun, D. (2019) · The Analyst · doi:10.1039/c9an01743g · Cited by 82
Chemometrics for Raman Spectroscopy Harmonization
Barton, B., Thomson, J., Lozano Diz, E., & Portela, R. (2022) · Applied Spectroscopy · doi:10.1177/00037028221094070 · Cited by 79
Schoot, M., Kapper, C., van Kollenburg, G., Postma, G., van Kessel, G., Buydens, L. M. C., & Jansen, J. J. (2020) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2020.104105 · Cited by 84
Kumbhar, D., Palliyarayil, A., Reghu, D., Shrungar, D., Umapathy, S., & Sil, S. (2021) · Carbon · doi:10.1016/j.carbon.2021.03.064 · Cited by 82
Self-citationHöppener, C., Aizpurua, J., Chen, H., Gräfe, S., Jório, A., Kupfer, S., Zhang, Z., & Deckert, V. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00323-5 · Cited by 81
“Advanced analysis methods, such as multivariate data analysis methods 27,54 , reduce data dimensionality and extract relevant information from TERS spectra, owing to the high correlation of some Raman bands that share the same source of variation 131,132 .”
Rahman, M. H.-U., Sikder, R., Tripathi, M., Zahan, M., Ye, T., Gnimpiéba, E. Z., Jasthi, B. K., Dalton, A. Β., & Gadhamshetty, V. (2024) · Chemosensors · doi:10.3390/chemosensors12070140 · Cited by 87
Jamieson, L. E., Li, A., Faulds, K., & Graham, D. (2018) · Royal Society Open Science · doi:10.1098/rsos.181483 · Cited by 81
“It is also common practice in biological Raman studies to use multivariate analysis to group samples and identify the major sources of spectral variation between them, with the authors then hypothesizing the source of these spectral differences from a biological context [9].”
BackgroundHuang, C., Cheng, C.-Y., & Lai, Y.-S. (2020) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2020.04.019 · Cited by 75
Analyzing Raman spectroscopic data
Ryabchykov, O., Guo, S., & Bocklitz, T. (2019) · Physical Sciences Reviews · doi:10.1515/psr-2017-0043 · Cited by 74
Rozali, N. L., Azizan, K. A., Singh, R., Jaafar, S. N. S., Othman, A., Weckwerth, W., & Ramli, U. S. (2022) · Food Control · doi:10.1016/j.foodcont.2022.109509 · Cited by 78
Li, D., Zhu, Z., & Sun, D. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2022.132679 · Cited by 71
Li, J., Tian, M., Li, C., Dwyer, J., Fullwood, N. J., Shen, H., & Martin, F. L. (2016) · Scientific Reports · doi:10.1038/srep20207 · Cited by 73
Albuquerque, R. M., Meira, H. M., Silva, I. D. D. L., da Silva, C. J. G., Almeida, F. C. G., de Amorim, J. D. P., Vinhas, G. M., Costa, A. F. D. S., & Sarubbo, L. A. (2020) · Polymers and Polymer Composites · doi:10.1177/0967391120912098 · Cited by 77
“A band in the region of 1510 cm 1 is seen for the BC/PHB blend containing CLO.”
MethodInfluentialXue, X., Liu, X., Lou, B., Yang, Y., Shi, N., Wen, F., Yang, X., & Liu, D. (2023) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2023.04.004 · Cited by 69
Moitra, P., Chaichi, A., Hasan, S. M. A., Dighe, K., Alafeef, M., Prasad, A., Gartia, M. R., & Pan, D. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114200 · Cited by 68
“…conventional multi-variate statistical analysis technique which by orthogonal transformation converts high dimensional Raman spectra into multiple unrelated independent variables, called principal components (PCs), avoiding any loss of valuable information (Crow et al., 2005; Gautam et al., 2015).”
Chaturvedi, D., Andugulapati, S. B., Bn, V., Ariese, F., Umapathy, S., & Rangarajan, A. (2016) · Biosensors · doi:10.3390/bios6040057 · Cited by 68
“For these reasons, pre-processing of the spectral data should be carried out [47,48].”
BackgroundSelf-citationRaman spectral cytopathology for cancer diagnostic applications
Traynor, D., Behl, I., O’Dea, D., Bonnier, F., Nicholson, S. A., O’Connell, F., Maguire, A. A., Flint, S. R., Galvin, S., Healy, C. M., et al. (2021) · Nature Protocols · doi:10.1038/s41596-021-00559-5 · Cited by 66
Leaf and Canopy Level Detection of Fusarium Virguliforme (Sudden Death Syndrome) in Soybean
Herrmann, I., Vosberg, S. K., Ravindran, P., SINGH, A. K., Chang, H., Chilvers, M. I., Conley, S. P., & Townsend, P. A. (2018) · Remote Sensing · doi:10.3390/rs10030426 · Cited by 65
“Spectral data, from each of the spectrometers, were then vector normalized by instrument to minimize the disparity in intensity levels [45].”
MethodNoothalapati, H., Iwasaki, K., & Yamamoto, T. (2021) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2021.119818 · Cited by 64
Sharma, S., Chophi, R., & Singh, R. (2019) · International Journal of Legal Medicine · doi:10.1007/s00414-019-02134-w · Cited by 64
Arendse, E., Nieuwoudt, H. H., Magwaza, L. S., Nturambirwe, J. F. I., Fawole, O. A., & Opara, U. L. (2020) · Food and Bioprocess Technology · doi:10.1007/s11947-020-02505-x · Cited by 64
“Further information on these and other related supervised algorithms have been extensively reviewed by various authors (Naes et al. 2002; Cozzolino et al. 2011; Gautam et al. 2015).”
BackgroundMethodInfluentialDarvin, M. E. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15092272 · Cited by 67
“…multivariate analysis method that correlates the changes in the positions, intensities, and shapes of Raman bands, and is used to relate two groups of variables (untreated and formulation-treated skin) by quantifying the difference between them across the selected spectral range [213,238].”
MethodGhosh, A., Raha, S., Dey, S., Chatterjee, K., Chowdhury, A. R., & Barui, A. (2018) · The Analyst · doi:10.1039/c8an02092b · Cited by 66
Forensic analysis of red lipsticks using ATR-FTIR spectroscopy and chemometrics
Chophi, R., Sharma, S., & Singh, R. (2019) · Forensic Chemistry · doi:10.1016/j.forc.2019.100209 · Cited by 62
Advances in Optical Detection of Human-Associated Pathogenic Bacteria
Locke, A. K., Fitzgerald, S. T., & Mahadevan-Jansen, A. M. (2020) · Molecules · doi:10.3390/molecules25225256 · Cited by 66
“The most common unsupervised models include PCA, K-means, and hierarchal cluster analysis (HCA).”
BackgroundInfluentialBerauer, B. J., Wilfahrt, P. A., Reu, B., Schuchardt, M. A., García-Franco, N., Zistl-Schlingmann, M., Dannenmann, M., Kiese, R., Kühnel, A., & Jentsch, A. (2020) · Agriculture Ecosystems & Environment · doi:10.1016/j.agee.2020.106929 · Cited by 62
Probing Biochemical Differences in Lipid Components of Human Cells by Means of ATR-FTIR Spectroscopy
Portaccio, M., Faramarzi, B., & Lepore, M. A. (2023) · Biophysica · doi:10.3390/biophysica3030035 · Cited by 60
Feidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59
“It de-emphasizes lower frequencies and emphasizes higher frequencies, although tending to accentuate noise.(31) However, since the use of derivatives appears to produce worse results, it is an indication that performed BT runs were very similar in their background most probably due to the use of the same analyzer equi…”
BackgroundFlanagan, A. R., Dalal, D., & Glavin, F. G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00815 · Cited by 66
“39,40 The steps for executing a chemometric analysis project from experimental design to analysis have been described in excellent detail.”
Boll, M. S., Doty, K. C., Wickenheiser, R. A., & Lednev, I. K. (2017) · Forensic Chemistry · doi:10.1016/j.forc.2017.08.001 · Cited by 59
“Chemometrics is the application of advanced statistics to chemical systems in order to enhance data interpretation [19].”
BackgroundPrats‐Mateu, B., Felhofer, M., de Juan, A., & Gierlinger, N. (2018) · Plant Methods · doi:10.1186/s13007-018-0320-9 · Cited by 59
“There are several unmixing methods applicable to spectroscopy but also to other fields [28, 29].”
MethodSharma, S., & Singh, R. (2019) · International Journal of Legal Medicine · doi:10.1007/s00414-019-02222-x · Cited by 59
Cordero, E., Korinth, F., Stiebing, C., Krafft, C., Schie, I., & Popp, J. (2017) · Sensors · doi:10.3390/s17081724 · Cited by 58
Weißer, J., Pohl, T., Heinzinger, M., Ivleva, N. P., Hofmann, T. F., & Glas, K. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116535 · Cited by 63
Qian, F., Wu, Y., & Peng, H. (2017) · Optics & Laser Technology · doi:10.1016/j.optlastec.2017.05.021 · Cited by 57
Gomes, V., Mendes‐Ferreira, A., & Melo‐Pinto, P. (2021) · Sensors · doi:10.3390/s21103459 · Cited by 58
“The Savitzky–Golay method is a moving-window-based local polynomial least-square fitting procedure, being one of the most commonly employed smoothing and differentiation techniques [44].”
MethodRaman spectroscopy as a potential diagnostic tool to analyse biochemical alterations in lung cancer
Zheng, Q., Li, J., Yang, L., Zheng, B. J., Wang, J., Lv, N., Luo, J., Martin, F. L., Liu, D., & He, J. (2020) · The Analyst · doi:10.1039/c9an02175b · Cited by 57
Liu, W., Tang, J., Lyu, J., Wang, J.-J., Pan, Y.-C., Shi, X.-Y., Liu, Q.-H., Zhang, X. L., Gu, B., & Wang, L. (2022) · Microbiology Spectrum · doi:10.1128/spectrum.02409-21 · Cited by 56
“However, raw Raman spectral data are not suitable for the identi fi cation of characteristic peaks due to the unwanted signals (noises) in the spectra (19).”
BackgroundAgustika, D. K., Mercuriani, I. S., Purnomo, C. W., Hartono, S., Trıyana, K., Iliescu, D. D., & Leeson, M. S. (2022) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2022.121339 · Cited by 55
“Normalization aims to compensate for the effects of scaling and spectrum shifts due to scattering, the effect of fluctuations in source power, and differences in sample characteristics such as differences in particle size [38].”
BackgroundMethodInfluentialAitekenov, S., Sultangaziyev, A., Abdirova, P., Yussupova, L., Gaipov, A., Utegulov, Z. N., & Bukasov, R. (2022) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2022.2036941 · Cited by 57
“processing approaches for Raman and infrared spectroscopy.([81]) Usually MVA analysis, if applied to urine or serum samples, is used to discriminate between patients with health conditions and healthy group.”
MethodFemtosecond stimulated Raman spectroscopy
Batignani, G., Ferrante, C., Fumero, G., Martinati, M., & Scopigno, T. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00314-6 · Cited by 55
“The methods, including Whittaker filters, iterative techniques, differentiation and spectral transform, have been adapted from those developed by the spontaneous Raman community for taking into account the peculiar lineshapes recorded in FSRS 76 .”
Coccato, A., & Caggiani, M. C. (2023) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6621 · Cited by 54
Metadata
- Authors
- Gautam, R., Vanga, S., Ariese, F., & Umapathy, S.
- Affiliations
- Indian Institute of Science Bangalore (IN)
- Venue
- EPJ Techniques and Instrumentation
- Published
- 2015-06-02
- Volume
- 2
- Issue
- 1
- ISSN
- 2195-7045 (ISSN-L)
- OpenAlex
- W1563946068
- Cited by
- 696
- References
- 97
- Citations by year
- 2026: 53 · 2025: 88 · 2024: 91 · 2023: 65 · 2022: 99 · 2021: 89 · 2020: 79 · 2019: 45 · 2018: 39 · 2017: 33 · 2016: 13 · 2015: 2
- FWCI
- 17.55
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- EPJ Techniques and Instrumentation (publishedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Indian Institute of Science
- Department of Biotechnology, Ministry of Science and Technology, India
- Department of Science and Technology, Ministry of Science and Technology, India
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Raman spectroscopy, infrared spectroscopy, Raman imaging, infrared imaging, multivariate analysis, spectral preprocessing, biological specimen, spectral interpretation, noise reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.