Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Open accessThe DOI matches its Crossref record; 93 of the 97 references it cites were found in a registry or an index.
Abstract
Raman and Infrared (IR) spectroscopies provide information about the structure, functional groups and environment of the molecules in the sample. In combination with a microscope, these techniques can also be used to study molecular distributions in heterogeneous samples. Over the past few decades Raman and IR microspectroscopy based techniques have been extensively used to understand fundamental biology and responses of living systems under diverse physiological and pathological conditions. The spectra from biological systems are complex and diverse, owing to their heterogeneous nature consisting of bio-molecules such as proteins, lipids, nucleic acids, carbohydrates etc. Sometimes minor differences may contain critical information. Therefore, interpretation of the results obtained from Raman and IR spectroscopy is difficult and to overcome these intricacies and for deeper insight we need to employ various data mining methods. These methods must be suitable for handling large multidimensional data sets and for exploring the complete spectral information simultaneously. The effective implementation of these multivariate data analysis methods requires the pretreatment of data. The preprocessing of raw data helps in the elimination of noise (unwanted signals) and the enhancement of discriminating features. This review provides an outline of the state-of-the-art data processing tools for multivariate analysis and the various preprocessing methods that are widely used in Raman and IR spectroscopy including imaging for better qualitative and quantitative analysis of biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Despite the wealth of information RS affords, the analysis and interpretation of experimental RS data remains a major challenge (37–39).”
From Hyperspectral unmixing for Raman spectroscopy via physics-constrained autoencoders (2024) · cites this paper as [39]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Statistics and Chemometrics for Analytical Chemistry
Miller, J. N., & Miller, J. C. (2005) · Cited by 3,783
Data Mining and Knowledge Discovery Handbook
(2010) · doi:10.1007/978-0-387-09823-4 · Cited by 2,190
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513 · cited 3×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodAutomated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049 · cited 1×
“For a simple Raman signal like a Raman spectrum of a non-fluorescent solid compound, a straight line fit through a couple of points could be sufficient enough, whereas for a complex Raman signal like a Raman spectrum of tissues/cells one might need many base points along with a fifth-order or higher polynomial fit [24…”
BackgroundAutomated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630 · cited 1×
“thresholds of a classification model [9, 38, 68, 95].”
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507 · cited 1×
“Hence, it is called extended MSC [48, 49].”
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475 · cited 1×
“mechanism of disease progression [66–69].”
Research works printed but not linked: 5
- 3. Gautam R, Samuel A, Sil S, Chaturvedi D, Dutta A, et al. Raman and Infrared Imaging: Applications and Advancements. Curr Sci. 2015;108:341-56.
- 21. Esbensen KH. Multivariate Data Analysis-in practice, 5 th Edition. CAMO; 2000.
- 23. Srinivasan GK. Vibrational Spectroscopic Imaging for Biomedical Applications, first edition. McGraw-Hill Professional; 2010.
- 36. Eilers PHC. Boelens HFM. Baseline correction with asymmetric least squares smoothing: Leiden University Medical Centre Report; 2005.
- 45. Bhargava R. Levin IW. Wiley-Blackwell: Spectroscopic Analysis using Infrared Multichannel Detectors; 2005.
Cited by
Items 301–400 of 735
Kim, M., Hong, J., Lee, D., Kim, S., Chun, H. S., Cho, Y., Kim, B. H., & Ahn, S. (2021) · Foods · doi:10.3390/foods10051034 · Cited by 13
Humic Acid Improves Zn Fertilization in Oxisols Successively Cultivated with Maize–Brachiaria
de Morais, E. G., Silva, C. A., & Jindo, K. (2021) · Molecules · doi:10.3390/molecules26154588 · Cited by 13
“The FTIR spectra dataset was pre-processed using the background correction and dataset normalization procedures [29].”
MethodBoateng, D., Hu, C., Dai, Y., Chu, K., Du, J., & Smith, Z. J. (2022) · The Analyst · doi:10.1039/d2an00984f · Cited by 13
Lasalvia, M., Gallo, C., Capozzi, V., & Perna, G. (2023) · Applied Sciences · doi:10.3390/app131810325 · Cited by 13
“They have proven effective in solving classification problems in the biomedical field according to measured vibrational spectra [18 – 20].”
BackgroundMethodSajdak, M., & Kotyczka-Morańska, M. (2018) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2018.02.019 · Cited by 14
Sinjab, F., Hashimoto, K., Badarla, V. R., Omachi, J., & Ideguchi, T. (2020) · Optics Express · doi:10.1364/oe.397521 · Cited by 14
Bertazioli, D., Piazza, M., Carlomagno, C., Gualerzi, A., Bedoni, M., & Messina, E. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108028 · Cited by 15
Siddikali, P., & Sreekanth, P. S. R. (2025) · Journal of Composites Science · doi:10.3390/jcs9040155 · Cited by 12
“This technique involves subtracting the mean from each spectral intensity value and then dividing by the standard deviation [21,22].”
Umprecht, A., Díaz, V. F., Hüpfl, B., Kozma, B., Schwaighofer, A., Henson, M. J., Nikzad‐Langerodi, R., & Spadiut, O. (2025) · Measurement · doi:10.1016/j.measurement.2025.117906 · Cited by 12
A robust support vector machine approach for Raman data classification
Piazza, M., Spinelli, A., Maggioni, F., Bedoni, M., & Messina, E. (2025) · Decision Analytics Journal · doi:10.1016/j.dajour.2025.100595 · Cited by 12
“…applying the Machine Learning methods to our dataset, we perform the following cleaning and preprocessing steps (see [20, 60]): • Outlier removal : a spectrum is considered as an outlier when it encounters issues during the acquisition phase that lead to a low signal-to-noise ratio (see [20]).”
InfluentialIn vivo Raman spectroscopy for real-time biochemical assessment of tissue pathology and physiology
Haugen, E. J., Gautam, R., Locke, A. K., & Mahadevan-Jansen, A. M. (2026) · Nature Protocols · doi:10.1038/s41596-025-01274-1 · Cited by 13
Self-citationRomero-González, R. R., Cobuccio, L., & Delatour, T. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2019.05.100 · Cited by 12
Lorenz, B., Guo, S., Raab, C., Leisching, P., Bocklitz, T. W., Rösch, P., & Popp, J. (2022) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6360 · Cited by 12
Guillon, F., Gierlinger, N., Devaux, M., & Gorzsás, A. (2022) · Advances in botanical research · doi:10.1016/bs.abr.2022.03.009 · Cited by 13
Rapid, Sensitive and Selective Optical Glucose Sensing with Stimulated Raman Scattering (SRS)
Golparvar, A. J., Boukhayma, A., Enz, C., & Carrara, S. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856428 · Cited by 12
“Interferences from other molecules should be assessed to accurately determine the glucose level in native body fluids, especially if the data analysis is univariate rather than multivariate-based [25].”
BackgroundSu, N., Dawuti, W., Hu, Y., & Zhao, H. (2022) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2022.103156 · Cited by 12
Monaghan, J. F., Byrne, H. J., Lyng, F. M., & Meade, A. D. (2024) · Radiation · doi:10.3390/radiation4030022 · Cited by 14
Kim, N., Kim, S., Choi, M., Park, H., Kim, N. H., Park, S. Y., Byun, K. M., & Lee, S. Y. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.065 · Cited by 12
Mitri, E., Barbieri, L., Vaccari, L., & Luchinat, E. (2018) · The Analyst · doi:10.1039/c7an01464c · Cited by 14
Mehta, N., Mahigir, A., Veronis, G., & Gartia, M. R. (2022) · Nanoscale Advances · doi:10.1039/d2na00469k · Cited by 12
“44,45 We have previously used PCA approach for Raman spectral analysis.”
MethodHiremath, G. S., Locke, A. K., Sivakumar, A., Thomas, G., & Mahadevan-Jansen, A. M. (2019) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.14738 · Cited by 12
Haroon, K., Arafeh, A., Cunliffe, S., Martin, P. A., Rodgers, T. L., Mendoza, C., & Baker, M. (2020) · Applied Spectroscopy · doi:10.1177/0003702820924043 · Cited by 12
“SNV has also been shown to be effective in removing noise in Raman spectra.(33,34) Therefore, different combinations of baseline correction and SNV (followed by mean centering) were trialed.”
MethodA review of machine learning approaches, challenges and prospects for computational tumor pathologyPreprint
Pan, L., Feng, Z., & Peng, S. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2206.01728 · Cited by 14
“Common normalization methods are 1 simple scaling; 2 sample-by-sample mean reduction (also known as removing the DC component); 3 feature normalization (making all features in the dataset have zero mean and unit variance) [13], [14].”
MethodXi, C., Jessurun, N., True, J., Khan, A. A., Tehranipoor, M. M., & Asadizanjani, N. (2022) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc51906.2022.00355 · Cited by 11
Sadeh, R., Ben‐David, R., Herrmann, I., & Peleg, Z. (2024) · Physiologia Plantarum · doi:10.1111/ppl.14480 · Cited by 11
“To overcome the illumination differences between environments and make the data more comparable, a vector normalization (Gautam et al., 2015) was performed on each plot spectra as follows: where ~ ρ i is the vector normalized reflectance in the i th band, ρ i is the reflectance in the i th band,…”
Jong, C. Y., Tristan, G., Felix, L. J. J., Yeap, E. W. Q., Dubbaka, S. R., Rao, H. N., & Wong, S. Y. (2025) · Organic Process Research & Development · doi:10.1021/acs.oprd.4c00496 · Cited by 11
Comparing machine learning methods on Raman spectra from eight different spectrometers
Lange, C., Borisyak, M., Kögler, M., Born, S., Ziehe, A., Neubauer, P. B., & Bournazou, M. N. C. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125861 · Cited by 11
Zhou, F., Chu, J., Lu, F., Ouyang, W., Liu, Q., & Wu, Z. (2025) · Environmental Technology & Innovation · doi:10.1016/j.eti.2025.104100 · Cited by 11
Li, G., Wang, Z. L., Wu, C., Wang, D., Han, I., Lee, J., Kaeli, D. R., Dy, J., Weinberger, K. Q., & Gu, A. Z. (2025) · ISME Communications · doi:10.1093/ismeco/ycaf015 · Cited by 11
“DR also offers other practical benefits like reduced dataset size, memory usage, and faster training [56].”
2025 photonics for agrifood roadmap: towards a sustainable and healthier planet
Smeesters, L., Venturini, F., Paulus, S., Mahlein, A., Perpetuini, D., Cardone, D., Merla, A., Gac, B., Perrin, S., Trégoat, D., et al. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/adbea9 · Cited by 16
Carlomagno, C., Gualerzi, A., Picciolini, S., Rodà, F., Banfi, P. I., Lax, A., & Bedoni, M. (2021) · Diagnostics · doi:10.3390/diagnostics11030508 · Cited by 13
“The PCA is an unsupervised data transformation procedure of complex data that reduces the input variables in a set of independent and orthogonal PCs maximizing the variance [9].”
MethodInfluentialMcNairn, C., Mansour, I., Muir, B., Thomson, R. M., & Murugkar, S. (2021) · Medical Physics · doi:10.1002/mp.15000 · Cited by 13
Ciszak, C., Mermoux, M., Connétable, D., Proietti, A., Chevallier, G., Epifano, E., Prillieux, A., Monceau, D., Pérusin, S., & Hacquin, A. (2023) · Corrosion Science · doi:10.1016/j.corsci.2023.111198 · Cited by 11
Li, J., Hu, L., Ying, G., & Martin, F. L. (2017) · Environmental Science Nano · doi:10.1039/c7en00164a · Cited by 13
Banaś, K., Banaś, A., Heussler, S. P., & Breese, M. B. H. (2017) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.06.048 · Cited by 11
Choi, S., Moon, S. W., Lee, S. H., Kim, W., Kim, S., Kim, S. K., Shin, J., Park, Y., Jin, K., & Kim, T. G. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.04.025 · Cited by 11
Identification of rice varieties specialties in Vietnam using Raman spectroscopy
Le, G. T., Trung, P. Q., & Dao, Y. H. (2020) · Vietnam Journal of Chemistry · doi:10.1002/vjch.202000017 · Cited by 11
Multivariate (O)PLS regression methods in forensic dating
Ortiz-Herrero, L., Olabarria, I. M., & Bartolomé, L. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116278 · Cited by 11
Woods, F. E. R., Jenkins, C. A., Jenkins, R. A., Chandler, S., Harris, D. A., & Dunstan, P. R. (2022) · Applied Spectroscopy · doi:10.1177/00037028221088320 · Cited by 12
“37 We also trialled EMSC as a pre-treatment prior to other methods to study the effect on classi fi cation.”
MethodPalumbo, D., Giorni, A., Minocchi, R., Amendola, R., & Guidi, M. C. (2022) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2022.103408 · Cited by 11
Application of Raman spectroscopy in the hospital environment
Pistiki, A. C., Salbreiter, M., Sultan, S., Rösch, P., & Popp, J. (2022) · Translational Biophotonics · doi:10.1002/tbio.202200011 · Cited by 11
Huo, J., Zou, G., Lin, L., Wang, K., Xing, S., Zhao, G., Liu, L., & Zhou, Y. (2019) · Applied Physics Letters · doi:10.1063/1.5115335 · Cited by 11
Jian, C., Boyan, J., Ying, Z., & Zhenyu, W. (2021) · Journal of Applied Spectroscopy · doi:10.1007/s10812-021-01161-z · Cited by 10
Khoo, T. C., Aalinkeel, R., Abbasi, S., Sharikova, A. V., Schwartz, S. A., Khmaladze, A. T., & Mahajan, S. D. (2022) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2022.06.098 · Cited by 10
Mclean, A., Veettil, T. C. P., Giergiel, M., & Wood, B. R. (2024) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2024.103708 · Cited by 10
Lattice distortion and strain induced crack formation in Y-doped BaZrO3
Lu, J., Li, H., Zhao, Z., Wu, J., Wu, X., & Chen, Q. (2024) · Solid State Ionics · doi:10.1016/j.ssi.2024.116681 · Cited by 10
Carman, N., Hausrath, E. M., Celestian, A. J., Chavez, J., Hermis, N. Y., LaRowe, D. E., Fraeman, A. A., Sheppard, R. Y., Adcock, C. T., Tschauner, O., et al. (2024) · ACS Earth and Space Chemistry · doi:10.1021/acsearthspacechem.4c00109 · Cited by 10
Szabó-Szőcs, B., Ficzere, M., Péterfi, O., & Galata, D. L. (2024) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2024.124957 · Cited by 10
Enhancing lettuce classification: Optimizing spectral wavelength selection via CCARS and PLS-DA
Dilillo, N., Sanna, A., Belcore, E., Smith, K. N., Piras, M., Montrucchio, B., & Ferrero, R. (2025) · Smart Agricultural Technology · doi:10.1016/j.atech.2025.100962 · Cited by 10
Real-Time Measurement of Ammonia (NH3) in Artillery Smoke Using a Passive FT-IR Remote Sensor
Kim, J.-S., Nam, H., Kim, H. J., Lee, J., & Park, B. (2019) · ACS Omega · doi:10.1021/acsomega.9b01305 · Cited by 10
Label-free quantification of soft tissue alignment by polarized Raman spectroscopy
Zhou, H., Piñeiro-Llanes, J., Sarntinoranont, M., Subhash, G., & Simmons, C. S. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.09.015 · Cited by 10
Elderderi, S., Sacré, P., Wils, L., Chourpa, I., Elbashir, A. A., Hubert, P., Byrne, H. J., Boudesocque‐Delaye, L., Ziémons, E., & Bonnier, F. (2022) · Molecules · doi:10.3390/molecules27154819 · Cited by 11
“Partial Least Squares Regression (PLSR): PLSR is a supervised multivariate method widely used to extract quantitative information from spectral data sets [73].”
MethodSoil spectroscopy with the Gaussian pyramid scale space
Behrens, T., Rossel, R. A. V., Ramírez-López, L., & Baumann, P. (2022) · Geoderma · doi:10.1016/j.geoderma.2022.116095 · Cited by 10
Bilkey, N., Li, H., Borodinov, N., Ievlev, A. V., Ovchinnikova, O. S., Dixit, R., & Foston, M. B. (2022) · Quantitative Plant Biology · doi:10.1017/qpb.2022.20 · Cited by 10
“All FTIR and AFM-IR spectra in this study were preprocessed applying spectral smoothing, baseline correction and normalisation approaches (Gautam et al., 2015) (see Supporting Information and Supplementary Figure S3).”
MethodPushpa, S. R., Sukumaran, R. K., & Savithri, S. (2023) · Biomass Conversion and Biorefinery · doi:10.1007/s13399-023-05032-9 · Cited by 10
“…1 using the formula a i , MMN = a i − a min a max − a min , where, a i , MMN , stands for min-max normalised spectra, a i , the original FTIR absorbance value, a max = max( a i ), the maximum absorbance value and a min = min( a i ), the minimum absorbance value of the original FTIR spectra [26].”
Lohumi, S., Kandpal, L. M., Seo, Y. W., & Cho, B. (2016) · Journal of Biosystems Engineering · doi:10.5307/jbe.2016.41.3.208 · Cited by 10
“This is in contrast to X T X in PCR, which obtains the latent variables used to predict the response variables (Gautam et al., 2015).”
BackgroundMethodSkogholt, J., Liland, K. H., & Indahl, U. G. (2017) · Journal of Chemometrics · doi:10.1002/cem.2962 · Cited by 10
“The least squares solution of (12) corresponds to finding the minimizer with respect to β of the expression ||Xβ − y||2 + μ||Pβ||2 + λ||Lβ||2, (13)”
BackgroundHelešicová, T., Pekárek, T., & Matějka, P. (2018) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2018.08.002 · Cited by 12
Aparna, R., Iyer, R. S., Das, T., Sharma, K. M., Sharma, A. K., & Srivastava, A. (2022) · Forensic Science International Reports · doi:10.1016/j.fsir.2022.100290 · Cited by 10
Tewes, T. J., Welle, M. C., Hetjens, B. T., Tipatet, K. S., Pavlov, S., Platte, F., & Bockmühl, D. P. (2023) · AI · doi:10.3390/ai4010006 · Cited by 13
“Due to diverse influences on Raman spectra that are not based on the bio-chemical differences of individual species, some data pretreatment is of great importance for the classification of different microorganisms [24,25].”
BackgroundMiloudi, L., Bonnier, F., Barreau, K., Bertrand, D., Perse, X., Yvergnaux, F., Byrne, H. J., Chourpa, I., & Munnier, E. (2018) · The Analyst · doi:10.1039/c8an00547h · Cited by 11
Schenk, C., Short, M., Rodriguez, J. S., Thierry, D. M., Biegler, L. T., García‐Muñoz, S., & Chen, W. (2020) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2019.106716 · Cited by 10
Camerlingo, C., Meo, G. D., Lepore, M. A., Lisitskiy, M., Poli, A., Portaccio, M., Romano, I., & Donato, P. D. (2020) · Sensors · doi:10.3390/s20154150 · Cited by 10
“, the normalization of the signal to the standard deviation of points with respect to the average signal [27,28].”
BackgroundSricharoen, N., Sukmanee, T., Pienpinijtham, P., Ekgasit, S., Kitahama, Y., Ozaki, Y., & Wongravee, K. (2021) · The Analyst · doi:10.1039/d1an00069a · Cited by 10
Medical Applications of Raman Spectroscopy
Paidi, S. K., Pandey, R., & Barman, I. (2020) · Wiley eBooks · doi:10.1002/9780470027318.a9699 · Cited by 10
Alsamad, F., Gobinet, C., Vuiblet, V., Jaisson, S., & Piot, O. (2020) · The Analyst · doi:10.1039/d0an90034f · Cited by 10
Robust baseline correction for Raman spectra by constrained Gaussian radial basis function fitting
Park, S., & Kim, H. (2024) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2024.105205 · Cited by 10
SERS-Enhanced CRISPR Biosensors: A Platform for Ultrasensitive Molecular Diagnostics
Rabiee, N. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.5c04024 · Cited by 10
del‐Valle, M., dos Santos, M. O., dos Santos, S. N., de Castro, P. A. A., Bernardes, E. S., & Zezéll, D. M. (2021) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2021.103309 · Cited by 9
Pressure driven phase transitions in honeycomb Fe4Nb2O9: A possible re-entrant multiferroic behavior
Sahu, M., Ghosh, B., Jana, R., Cheng, J., & Mukherjee, G. D. (2022) · Journal of Applied Physics · doi:10.1063/5.0083331 · Cited by 9
Chalyan, T., Magnus, I., Konstantaki, M., Pissadakis, S., Diamantakis, Z., Hugo Thienpont, A., & Ottevaere, H. (2022) · Biosensors · doi:10.3390/bios12040227 · Cited by 10
“Scattering effects inside the solid samples leading to different optical path lengths for the same chemical concentration are commonly removed by using a Standard Normal Variate transformation [21].”
MethodKim, S., Shin, S. Y., Saeed, M., Ryu, J. E., Kim, J.-S., Ahn, J. J., Jung, Y., Moon, J. M., Choi, C. H., & Choi, H. (2023) · Metabolites · doi:10.3390/metabo14010002 · Cited by 9
“For vector normalization, first-and second-derivative spectra were used, and each derivative value was divided by the Euclidean norm [28].”
MethodLahiri, P., Das, S., Thakur, S., Mehra, R., Ranjan, P., Wig, N., Dar, L., Bhattacharyya, T. K., Sengupta, S., & Lahiri, B. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c01260 · Cited by 9
Vallejo-Pérez, M. R., Cetina-Denis, J., Ley, M. A. C., Sosa-Herrera, J. A., Ortíz, J. C. D., Vázquez, Á. G. R., & Navarro-Contreras, H. R. (2024) · Crop Protection · doi:10.1016/j.cropro.2024.107003 · Cited by 10
Zheng, X., Wu, G., Lv, G., Yin, L., & Lv, X. (2022) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2022.103027 · Cited by 9
Ingwani, T., Chaukura, N., Mamba, B. B., Nkambule, T. T. I., & Gilmore, A. M. (2023) · Molecules · doi:10.3390/molecules28207048 · Cited by 10
“In order to obtain accurate data analysis results by removing noise or unwanted signals, the preprocessing of the emission spectral data involved the exclusion of emission data just larger than 500 nm and higher [53].”
MethodKrafft, C., Schmitt, M. P., Schie, I. W., Cialla‐May, D., Matthäus, C., Bocklitz, T. W., & Popp, J. (2017) · Angewandte Chemie · doi:10.1002/ange.201607604 · Cited by 9
Dual-modal cancer detection based on optical pH sensing and Raman spectroscopy
Kim, S., Lee, S. H., Min, S. Y., Byun, K. M., & Lee, S. Y. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.10.105002 · Cited by 9
Heilala, B., Mäkinen, A., Nissinen, I., Nissinen, J., Mäkynen, A., & Perämäki, P. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.11.010 · Cited by 9
Sajdak, M., Micek, B., & Hrabak, J. (2019) · Journal of the Energy Institute · doi:10.1016/j.joei.2019.01.012 · Cited by 9
Kandpal, L. M., Lee, J., Bae, H., Kim, M. S., Baek, I., & Cho, B. (2020) · Sensors · doi:10.3390/s20010273 · Cited by 9
“Normalization involves the fitting of data within unity by cor ecting the mean, maximum, and range values, s all data values take on a valu between 0 and 1 [15,16].”
MethodEmerging trends in biomedical imaging and disease diagnosis using Raman spectroscopy
Paidi, S. K., Pandey, R., & Barman, I. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818870-5.00018-6 · Cited by 12
Chaudhary, N., Nguyen, T. N. Q., Maguire, A., Wynne, C., & Meade, A. D. (2021) · Analytical Methods · doi:10.1039/d0ay02040k · Cited by 9
Nazeer, S. S., Sreedevi, T. P., & Jayasree, R. S. (2021) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2021.119741 · Cited by 9
Trajectory Inference for Unraveling Dynamic Biological Processes from Raman Spectral Data
Goffin, N., Buache, É., Charpentier, C., Lehrter, V., Morjani, H., Gobinet, C., & Piot, O. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c04901 · Cited by 9
van Lanschot, C. G. F., Schut, T. C. B., Barroso, E. M., Sewnaik, A., Hardillo, J. A., Monserez, D., Meeuwis, C. A., Keereweer, S., de Jong, R. J. B., Puppels, G. J., et al. (2023) · Lasers in Medical Science · doi:10.1007/s10103-023-03849-4 · Cited by 9
“To separate tumor spectra from non-cancerous spectra, LDA was used to find the direction in PCA space that maximizes the ratio between the inter-group and intra-group variances [25, 26].”
MethodIhara, L., Wu, G., Cavaleiro, A., Morina, A., & Yang, L. (2025) · Coatings · doi:10.3390/coatings15020218 · Cited by 8
Zhang, X., Fan, A., Zhang, L., Shu, Z., Liu, X., Wei, S., Ma, W., Wang, J., Pan, Y., & Zhang, X. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.111294 · Cited by 8
Rourke-Funderburg, A. S., Mahadevan-Jansen, A. M., & Locke, A. K. (2024) · The Analyst · doi:10.1039/d4an00854e · Cited by 8
Improving signal-to-noise ratio of Raman measurements based on ensemble learning approach
Jia, Y., Gao, Y., Xu, W., Wang, Y., Yan, Z., Chen, K., & Chen, S. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-024-05676-0 · Cited by 9
“Besides, in case of amplitude variations among different Raman measurements due to manual operation, each of the above-mentioned Raman spectrum was normalized by its maximum Raman intensity [33].”
Çolak, S. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6812 · Cited by 8
Geochemical Fingerprints of Ginkgoales Across the Triassic-Jurassic Boundary of Greenland
Vajda, V., Pučetaitė, M., & Steinthorsdottir, M. (2021) · International Journal of Plant Sciences · doi:10.1086/715506 · Cited by 8
de Morais, E. G., Silva, C. A., Maluf, H. J. G. M., & Guilherme, L. R. G. (2022) · ACS Agricultural Science & Technology · doi:10.1021/acsagscitech.2c00049 · Cited by 8
Plazas, D., Ferranti, F., Liu, Q., Choobbari, M. L., & Ottevaere, H. (2024) · Applied Spectroscopy · doi:10.1177/00037028241233304 · Cited by 8
“25 Additionally, raw data are processed to enhance important features that can be useful for further analysis.”
BackgroundMethodInfluentialATR-FTIR spectroscopy as a quality control system for monitoring the storage of blood products
Martin, M., Pérez-Guaita, D., & Wood, B. R. (2021) · Analytical Methods · doi:10.1039/d1ay01242h · Cited by 8
Caggiani, M. C., Cavarra, M., Barone, G., Coccato, A., Manenti, A. M., & Mazzoleni, P. (2023) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6588 · Cited by 8
Scattering-based optical techniques for olive oil characterization and quality control
Delfino, I., Cavella, S., & Lepore, M. A. (2018) · Journal of Food Measurement & Characterization · doi:10.1007/s11694-018-9933-y · Cited by 9
Yaltaye, M. W., Zhao, Y., Zhan, K., Bozó, É., Xin, P.-L., Farrahi, V., Angelis, F. D., & Huang, J. (2025) · Data Science for Photonics and Biophotonics · doi:10.1021/acs.jpclett.5c01753 · Cited by 8
Borg, A., Elhabiri, M., Calvé, S. L., & Portaluri, V. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70118 · Cited by 7
“…(i) Reviews of applications of Raman spectroscopy coupled to chemometrics (Pan et al. 2022; Xu et al. 2020); (ii) Guidelines for model development (Gautam et al. 2015; Guo et al. 2021); (iii) Critical reviews of published models aiming to highlight good and bad practices (Khristoforova et al.…”
de Morais, E. G., & Silva, C. A. (2024) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103624.2024.2306234 · Cited by 7
“The infrared analysis generated raw spectra, whose dataset was used in PLS model generation without treatment or with the normalization pre-processing of FTIR spectra dataset (Gautam et al. 2015).”
Method
Metadata
- Authors
- Gautam, R., Vanga, S., Ariese, F., & Umapathy, S.
- Affiliations
- Indian Institute of Science Bangalore (IN)
- Venue
- EPJ Techniques and Instrumentation
- Published
- 2015-06-02
- Volume
- 2
- Issue
- 1
- ISSN
- 2195-7045 (ISSN-L)
- OpenAlex
- W1563946068
- Cited by
- 696
- References
- 97
- Citations by year
- 2026: 53 · 2025: 88 · 2024: 91 · 2023: 65 · 2022: 99 · 2021: 89 · 2020: 79 · 2019: 45 · 2018: 39 · 2017: 33 · 2016: 13 · 2015: 2
- FWCI
- 17.55
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- EPJ Techniques and Instrumentation (publishedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Indian Institute of Science
- Department of Biotechnology, Ministry of Science and Technology, India
- Department of Science and Technology, Ministry of Science and Technology, India
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Raman spectroscopy, infrared spectroscopy, Raman imaging, infrared imaging, multivariate analysis, spectral preprocessing, biological specimen, spectral interpretation, noise reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.