Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Open accessThe DOI matches its Crossref record; 93 of the 97 references it cites were found in a registry or an index.
Abstract
Raman and Infrared (IR) spectroscopies provide information about the structure, functional groups and environment of the molecules in the sample. In combination with a microscope, these techniques can also be used to study molecular distributions in heterogeneous samples. Over the past few decades Raman and IR microspectroscopy based techniques have been extensively used to understand fundamental biology and responses of living systems under diverse physiological and pathological conditions. The spectra from biological systems are complex and diverse, owing to their heterogeneous nature consisting of bio-molecules such as proteins, lipids, nucleic acids, carbohydrates etc. Sometimes minor differences may contain critical information. Therefore, interpretation of the results obtained from Raman and IR spectroscopy is difficult and to overcome these intricacies and for deeper insight we need to employ various data mining methods. These methods must be suitable for handling large multidimensional data sets and for exploring the complete spectral information simultaneously. The effective implementation of these multivariate data analysis methods requires the pretreatment of data. The preprocessing of raw data helps in the elimination of noise (unwanted signals) and the enhancement of discriminating features. This review provides an outline of the state-of-the-art data processing tools for multivariate analysis and the various preprocessing methods that are widely used in Raman and IR spectroscopy including imaging for better qualitative and quantitative analysis of biological samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Despite the wealth of information RS affords, the analysis and interpretation of experimental RS data remains a major challenge (37–39).”
From Hyperspectral unmixing for Raman spectroscopy via physics-constrained autoencoders (2024) · cites this paper as [39]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Statistics and Chemometrics for Analytical Chemistry
Miller, J. N., & Miller, J. C. (2005) · Cited by 3,783
Data Mining and Knowledge Discovery Handbook
(2010) · doi:10.1007/978-0-387-09823-4 · Cited by 2,190
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513 · cited 3×
“In the literature, many studies have been conducted where the PC-LDA model is used for classification purposes [38, 45, 47, 58, 71].”
MethodAutomated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049 · cited 1×
“For a simple Raman signal like a Raman spectrum of a non-fluorescent solid compound, a straight line fit through a couple of points could be sufficient enough, whereas for a complex Raman signal like a Raman spectrum of tissues/cells one might need many base points along with a fifth-order or higher polynomial fit [24…”
BackgroundAutomated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630 · cited 1×
“thresholds of a classification model [9, 38, 68, 95].”
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507 · cited 1×
“Hence, it is called extended MSC [48, 49].”
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475 · cited 1×
“mechanism of disease progression [66–69].”
Research works printed but not linked: 5
- 3. Gautam R, Samuel A, Sil S, Chaturvedi D, Dutta A, et al. Raman and Infrared Imaging: Applications and Advancements. Curr Sci. 2015;108:341-56.
- 21. Esbensen KH. Multivariate Data Analysis-in practice, 5 th Edition. CAMO; 2000.
- 23. Srinivasan GK. Vibrational Spectroscopic Imaging for Biomedical Applications, first edition. McGraw-Hill Professional; 2010.
- 36. Eilers PHC. Boelens HFM. Baseline correction with asymmetric least squares smoothing: Leiden University Medical Centre Report; 2005.
- 45. Bhargava R. Levin IW. Wiley-Blackwell: Spectroscopic Analysis using Infrared Multichannel Detectors; 2005.
Cited by
Items 401–500 of 735
Latka, I., Mogensen, K., Knorr, F., Kuzucu, C., Windirsch, F., Sandic, D., Popp, J., Hermann, G. G., & Schie, I. W. (2024) · Cancers · doi:10.3390/cancers16183238 · Cited by 7
Zhang, J., Wei, X., Song, Z., Chen, Z., & Jin, J. (2025) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2025.109940 · Cited by 7
Cell Culture Media and Raman Spectra Preprocessing Procedures Impact Glucose Chemometrics
Pavurala, N., Madhavarao, C. N., Lee, J., Das, J., Ashraf, M., & O’Connor, T. F. (2025) · Journal of Chemometrics · doi:10.1002/cem.70005 · Cited by 8
“Some of the commonly used preprocessing techniques are reviewed elsewhere [26, 27] and include, besides baseline correction, derivatives for spectral offset, standard normal variate (SNV) transformation, multiplicative scatter correction (MSC) for additive and multiplicative scatter effects,…”
Plasmon-Tuned Particles for the Amplification of Surface-Enhanced Raman Scattering from Analytes
de Oliveira, T. T. S., Abbasi, A., Andreu, I., & Bose, A. (2022) · Langmuir · doi:10.1021/acs.langmuir.2c02451 · Cited by 7
Vrtělka, O., Králová, K., Fousková, M., & Setnička, V. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126261 · Cited by 7
Ramesh, S., Nazeer, S. S., Thomas, S., Vivek, V., & Jayasree, R. S. (2020) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.119240 · Cited by 7
Liné, C., Reyes-Herrera, J., Bakshi, M., Wazne, M., Costa, V., Roujol, D., Jamet, É., Castillo-Michel, H. A., Emmanuel Flahaut, B., & Larue, C. (2021) · Environmental Science Nano · doi:10.1039/d1en00455g · Cited by 7
Alix, J. J. P., Plesia, M., Hool, S. A., Coldicott, I., Kendall, C. A., DBE, P. J. S., Mead, R. J., & Day, J. C. C. (2022) · Muscle & Nerve · doi:10.1002/mus.27671 · Cited by 7
Dahms, M., Eiserloh, S., Rödel, J., Makarewicz, O., Bocklitz, T. W., Popp, J., & Neugebauer, U. (2022) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2022.930011 · Cited by 8
Müller, D., Schuhmacher, D., Schörner, S., Großerueschkamp, F., Tischoff, I., Tannapfel, A., Reinacher‐Schick, A., Gerwert, K. B., & Mosig, A. (2023) · The Analyst · doi:10.1039/d3an00166k · Cited by 8
Cross-sectional hyperspectral imaging of proton implanted diamond
Turaga, S. P., Jin, H., Teo, E. J., & Bettiol, A. A. (2019) · Applied Physics Letters · doi:10.1063/1.5109290 · Cited by 7
Magina, S. P., & Evtuguin, D. V. (2025) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2025.107884 · Cited by 7
Bispo, D. S. C., Graça, I. C. R., Rodrigues, J. A., Martins, J. C., Nolasco, M. M., Marques, M. P. M., Nogueira, H. I. S., Mano, J. F., Oliveira, M. B., Ribeiro-Claro, P. J. A., et al. (2025) · Stem Cell Reviews and Reports · doi:10.1007/s12015-025-10943-3 · Cited by 6
“For a more in-depth discussion on MVA techniques and their application to spectral data, including that obtained through FTIR and Raman spectroscopy, readers are referred else - where [ 37 , 41 – 43].”
Valous, N. A., Zörnig, I., & Jäger, D. (2025) · Clinical and Translational Medicine · doi:10.1002/ctm2.70487 · Cited by 6
“From a computational standpoint, statistical 51 and machine learning 52 methods will continue to play key roles in discerning subtle spectral differences associated with various disease states or treatment responses.”
Yu, M., Zeng, J., Li, Y., Fan, W., Wang, L., Wang, H. E., & Bao, J. (2025) · Frontiers in Plant Science · doi:10.3389/fpls.2025.1666460 · Cited by 6
Automated Baseline Correction Evaluation Score for Raman Spectroscopy
Innocente, S., Visentin, A., Andersson‐Engels, S., Komolibus, K., & Gautam, R. (2026) · ACS Omega · doi:10.1021/acsomega.5c09870 · Cited by 6
Self-citationDexter, A., Tsikritsis, D., Belsey, N. A., Thomas, S. A., Venton, J., Bunch, J., & Romanchikova, M. (2022) · Journal of Molecular Pathology · doi:10.3390/jmp3030014 · Cited by 9
Elderderi, S., Bonnier, F., Perse, X., Byrne, H. J., Yvergnaux, F., Chourpa, I., Elbashir, A. A., & Munnier, E. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15061571 · Cited by 6
“PLSR is extensively referenced in the literature as a robust and wellrecognised quantitative approach used along with vibrational spectroscopy [65].”
MethodInfluentialInfrared Spectroscopy for Rapid Triage of Cancer Using Blood Derivatives: A Reality Check
Nazeer, S. S., Venkataraman, R. K., Jayasree, R. S., & Bayry, J. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02590 · Cited by 6
Behl, I., Calado, G., Vishwakarma, A., Traynor, D., Flint, S. R., Galvin, S., Healy, C. M., Malkin, A., Byrne, H. J., & Lyng, F. M. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125721 · Cited by 7
A Graph Based Raman Spectral Processing Technique for Exosome Classification
Ngo, V. M., Bolger, E., Goodwin, S., O’Sullivan, J., Dinh, C. V., & Roantree, M. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-95838-0_34 · Cited by 6
Shatar, L., Pillai, N., Chee, H., Mustafa, F. H., Nasir, M. N. M., Zakaria, R. B., Mustafa, M. K., Zain, M. N. M., & Suhailin, F. H. (2025) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2025.2530703 · Cited by 6
“[199] Baseline correction removes fluorescence background, while smoothing reduces high-frequency noise without distorting peak features.”
Chemiresistor Sensors Based on Gold Nanoparticle Composites
Daskal, Y., Dittrich, R., Walter, J., & Joseph, Y. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.08.828 · Cited by 6
Qian, F., Wu, Y., & Peng, H. (2017) · Applied Spectroscopy · doi:10.1177/0003702817700656 · Cited by 6
Rossignol, J., Dujourdy, L., Stuerga, D., Cayot, P., Gougeon, R. D., & Bou‐Maroun, E. (2020) · Sensors · doi:10.3390/s20216224 · Cited by 6
Kim, S., Kim, Y. J., Bang, A., Kim, W., Choi, S., & Lee, H. J. (2020) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.119186 · Cited by 6
Comparison of Dual Beam Dispersive and FTNIR Spectroscopy for Lactate Detection
Baishya, N., Mamouei, M., Budidha, K., Qassem, M., Vadgama, P. M., & Kyriacou, P. A. (2021) · Sensors · doi:10.3390/s21051891 · Cited by 6
“Multivariate analysis together with chemometric techniques have enabled decomposition and analysis of NIR spectroscopic data by providing precise information between the variables/wavelengths and observations/concentration, which is otherwise not possible, as spectral data consists of a large volume of variables [23].”
Kuhar, N., Nazeer, S. S., Kumar, R. V., Mukherjee, G., & Umapathy, S. (2021) · Lasers in Surgery and Medicine · doi:10.1002/lsm.23427 · Cited by 6
“with achieving maximum class discrimination [6,7,31].”
BackgroundSelf-citationPrada, P., Brunel, B., Moulin, D., Rouillon, L., Netter, P., Lœuille, D., Slimano, F., Bouché, O., Peyrin‐Biroulet, L., Jouzeau, J., et al. (2022) · Journal of Biophotonics · doi:10.1002/jbio.202200200 · Cited by 6
An FTIR Spectroscopy Investigation on Different Methods of Lipid Extraction from HepG2 Cells
Faramarzi, B., Moggio, M., Cardamuro, V., Portaccio, M., Diano, N., Manti, L., & Lepore, M. A. (2022) · International Electronic Conference on Sensors and Applications (ECSA) · doi:10.3390/ecsa-9-13263 · Cited by 6
“To make this comparison, the background was subtracted, and a Standard Normal Variate (SNV) normalization was performed [8].”
Kožíšek, J., Šlouf, M., & Šloufová, I. (2023) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2023.122454 · Cited by 6
Single-Cell Techniques in Environmental Microbiology
Shan, Y., Guo, Y., Jiao, W., & Zeng, P. (2023) · Processes · doi:10.3390/pr11041109 · Cited by 8
Huang, J., Xia, S., Jia, M., Chen, Y., Li, J., Wang, K., & Rui, Y. (2023) · Optik · doi:10.1016/j.ijleo.2023.171184 · Cited by 6
A study of hormonal effects in cervical smear samples using Raman spectroscopy
Traynor, D., Kearney, P., Ramos, I., Martin, C. M., O’Leary, J. J., & Lyng, F. M. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700240 · Cited by 8
Klijn, M. E., & Hubbuch, J. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.02.006 · Cited by 6
Nayrac, N., Bellenger, J., & Segura, P. A. (2022) · Analytical Methods · doi:10.1039/d2ay01201d · Cited by 6
Detecting wheat flour adulteration by portable infrared and Raman spectroscopies
Oluwakayode, A., Stradling, J., Medina, A., Krska, R., & Goodacre, R. (2026) · Applied Food Research · doi:10.1016/j.afres.2026.101913 · Cited by 5
Pezzotti, G., Adachi, T., Kitagawa, K., Ikegami, S., Imamura, H., Yamamoto, T., Okuma, K., Matsuo, Y., Zhu, W., Yasukochi, Y., et al. (2026) · Frontiers in Microbiology · doi:10.3389/fmicb.2026.1784125 · Cited by 5
“H bending vibrations (Di Rocco et al., 2001; Gautam et al., 2015).”
Cruz, C., Arafeh, A., Martin, P. A., Fonte, C. P., Simone, A. D., Oppong, F. K., Jeatt, W., & Rodgers, T. L. (2023) · Applied Spectroscopy · doi:10.1177/00037028231176824 · Cited by 5
Grading of Melanoma Tissues by Raman MicroSpectroscopy
Lazzini, G., & D’Acunto, M. (2023) · doi:10.3390/engproc2023051010 · Cited by 5
“Finally, the spectra were normalized with the Min–Max method [9] and rescaled by setting the mean to 0 and the variance to 1.”
MethodPushpa, S. R., Awoyale, A. A., Lokhat, D., Sukumaran, R. K., & Savithri, S. (2023) · Bioresource Technology Reports · doi:10.1016/j.biteb.2023.101747 · Cited by 8
Manaka, H., Toyoda, K., & Miura, Y. (2024) · Science and Technology of Advanced Materials Methods · doi:10.1080/27660400.2024.2342234 · Cited by 5
Ghazanfarpour, S., Sheikhsofla, A., Pourrahimi, M., Sharma, S. M., Farah, G. M., Skomra, A., Sharikova, A. V., Schwartz, S. A., Mahajan, S., Khmaladze, A., et al. (2023) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2025.151646 · Cited by 5
Kostovska, R., Cruz, J., Drouin, G., Horan, B., Tobin, J. T., O’Callaghan, T. F., Hettinga, K. A., Kelly, A. L., & Gómez‐Mascaraque, L. G. (2025) · Journal of Dairy Science · doi:10.3168/jds.2025-26489 · Cited by 5
The emerging applications and advancements of Raman spectroscopy in pediatric cancers
Li, C., Feng, C., Xu, R., Jiang, B., Li, L., He, Y., Tu, C., & Li, Z. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1044177 · Cited by 6
“In general, multivariate analysis can be divided into two classes: supervised and unsupervised, based on targets and samples (71).”
BackgroundCalvini, R., & Amigo, J. M. (2024) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2024.105118 · Cited by 5
Bilal, M., Bilal, M., Saleem, M. S., Khurram, M., Khan, S., Ullah, R., Ali, H., Ahmed, M., Shahzada, S., & Khan, E. U. (2017) · Laser Physics · doi:10.1088/1555-6611/aa5a94 · Cited by 5
Luna, V. J. P., s.a.s, M., & Martínez, J. M. (2017) · Journal of Science with Technological Applications · doi:10.34294/j.jsta.17.3.23 · Cited by 5
Simultaneous SERS detection using hexagonal hollow Au-Ag nanoparticles with near infrared plasmon
Rekha, C. R., Jiji, S. G., Nayar, V. U., & Gopchandran, K. G. (2021) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2021.103233 · Cited by 5
Schneider, S., Schmidtke, C., Putzien, S., Dietzsch, M., Emig, S., Meyer, L., Nestle, N., Sándor, A. N., Kriegenhofer, K., Häfner, K., et al. (2021) · Road Materials and Pavement Design · doi:10.1080/14680629.2021.1902843 · Cited by 5
“This is repeated for all spectra in the data set (Gautam et al., 2015).”
BackgroundData analysis in SERS diagnostics
Fornasaro, S., Beleites, C., Sergo, V., & Bonifacio, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-820548-8.00002-3 · Cited by 8
Gautam, R., Chaturvedi, D., Sil, S., Kuhar, N., Singh, S., & Umapathy, S. (2022) · Photonics · doi:10.3390/photonics9090648 · Cited by 7
Self-citationDawuti, W., Dou, J., Li, J., Liu, H., Zhao, H., Sun, L., Chu, J., Lin, R., & Lü, G. (2023) · Diagnostics · doi:10.3390/diagnostics13040619 · Cited by 5
“Vector normalization processing was conducted on each spectrum [30].”
MethodDigitalization platform and supervisory control of an integrated continuous bioprocess
Feidl, F. (2019) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000381363 · Cited by 6
Isac, D. L., Rosca, E., Airinei, A., Ursu, E., Puf, R., Man, I. C., Neamțu, A., & Laaksonen, A. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125828 · Cited by 4
Yang, D., Tao, Q., Wang, Z., Li, Y., Luo, X., Wan, X.-H., Huang, M., Wang, X., Wang, X., & Wu, Z. (2025) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2025.105451 · Cited by 4
Rao, Y., Li, H., Ding, X., Wang, B., Liu, Y., & Zhao, X. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126759 · Cited by 6
Dietrich, A., Heim, L., & Hubbuch, J. J. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1631807 · Cited by 5
Pre- and post-harvest spectral estimation of carnosic acid and rosmarinic acid in rosemary
Mishra, A., Krief, A., Sahoo, M. M., Shachter, A., Gonda, I., Dudai, N., Trigano, T., & Herrmann, I. (2026) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2026.111501 · Cited by 4
Li, Z., Wang, Y., Deng, Z., & Zhao, J. (2026) · Molecules · doi:10.3390/molecules31101599 · Cited by 4
Koymeth, S., Yao, B., Paluch, M., Dulski, M., Swadzba-Kwasny, M., & Wojnarowska, Ż. (2024) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.3c08506 · Cited by 4
Colleran, A., Lima, C. A., Xu, Y., Millichope, A., Murray, S., & Goodacre, R. (2024) · The Analyst · doi:10.1039/d4an00762j · Cited by 4
Khumaidi, A., Raafi’udin, R., & Triastuti, N. S. (2024) · Instrumentation Mesure Métrologie · doi:10.18280/i2m.230604 · Cited by 4
“Spectral transformations, such as clipping, scatter correction, smoothing, and derivatives, have been shown to improve data quality by eliminating distractions [22-24].”
Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement
Serrano, T., Espley, A. F., Potter, S. M., Ross, K. A., Tse, P., Bessen, N. P., Felmy, H. M., Lackey, H. E., Allred, J. R., Seiner, B. N., et al. (2025) · ACS Omega · doi:10.1021/acsomega.4c07963 · Cited by 4
Abate, M. G., Tafese, Z., & Belachew, T. (2025) · Frontiers in Nutrition · doi:10.3389/fnut.2025.1568887 · Cited by 4
“Finally, the household’s wealth index was calculated as non-dummy variables were divided into three categories: highest, medium, and lowest household wealth index (27).”
Huang, Y., Huang, J., Zheng, X., Wu, A., Wu, G., Xu, L., & Lü, G. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126945 · Cited by 4
Informatics-Aided Raman Microscopy for Nanometric 3D Stress Characterization
Wang, H., Zhang, H., Da, B., Shiga, M., Kitazawa, H., & Fujita, D. (2018) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.7b12415 · Cited by 4
James, J., Thomas, G. V., Sidharthan, S. K., Maria, H. J., Rouxel, D., Strankowski, M., Kalarikkal, N., Laroze, D., Oluwafemi, O. S., Volova, T. G., et al. (2022) · Journal of Applied Polymer Science · doi:10.1002/app.52978 · Cited by 4
Halfway to Automated Feeding of Chinese Hamster Ovary Cells
Tomažič, S., & Škrjanc, I. (2023) · Sensors · doi:10.3390/s23146618 · Cited by 4
“Of these methods, SNV normalisation is the most commonly used [39,40].”
MethodRavera, F., Efeoğlu, E., & Byrne, H. J. (2024) · The Analyst · doi:10.1039/d4an00315b · Cited by 4
Demir, K., Nguyen, B. H., Rooney, J. S., Xue, B., Zhang, M., Lagutin, K., MacKenzie, A., Gordon, K. C., & Killeen, D. P. (2024) · IEEE Congress on Evolutionary Computation (CEC) · doi:10.1109/cec60901.2024.10612136 · Cited by 5
de Morais, E. G., Silva, C. A., Gao, S., Melo, L. C. A., Benevenute, P. A. N., Lago, B. C., Teodoro, J. C., & Guilherme, L. R. G. (2025) · Sustainability · doi:10.3390/su17041616 · Cited by 8
Delfino, I., Falco, M. D., Lepore, M. A., & Portaccio, M. (2025) · Radiation · doi:10.3390/radiation5020010 · Cited by 4
Duan, P., Li, J., Yang, W., Li, X., Long, M., Feng, X., Zhang, Y., Chen, C., Morais, C. L. M., Martin, F. L., et al. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201800304 · Cited by 4
Sharma, S., Sharma, S., & Singh, R. (2020) · Arab Journal of Forensic Sciences and Forensic Medicine · doi:10.26735/kamk2533 · Cited by 4
Sharma, S., Jossan, J. K., & Singh, R. (2020) · Arab Journal of Forensic Sciences and Forensic Medicine · doi:10.26735/ayfk5009 · Cited by 4
Raman spectroscopy accurately classifies burn severity in an ex vivo model
Ye, H., Rahul, R., Krüger, U., Wang, T., Shi, S., Norfleet, J., & De, S. (2020) · Burns · doi:10.1016/j.burns.2020.08.006 · Cited by 4
Jossan, J. K., Sharma, S., Jindal, P., & Singh, R. (2020) · Arab Journal of Forensic Sciences and Forensic Medicine · doi:10.26735/qmfz6158 · Cited by 4
A spectroscopic diagnostic for rheumatoid arthritis using liquid biopsies
Chaudhary, N., Nguyen, T. N. Q., Ahmad, M., Harrington, R., Jefferies, C. A., Kearns, G. M., Meade, A. D., & Wynne, C. (2021) · Clinical Spectroscopy · doi:10.1016/j.clispe.2021.100009 · Cited by 4
PLS Regression Based on ATR-FTIR to Predict Organomineral Fertilizers Properties and Nutrient Pools
de Morais, E. G., Maluf, H. J. G. M., Silva, C. A., & de Paula, L. H. D. (2022) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103624.2022.2139391 · Cited by 4
“All ATR-FTIR spectra samples were submitted to minimum normalization (Gautam et al. 2015).”
MethodWilk, A., Dróźdż, A., Olbrich, K., Janik-Olchawa, N., Setkowicz, Z., & Chwiej, J. G. (2022) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2022.122086 · Cited by 4
Zhao, Y., Tang, Y., Wasalathanthri, D. P., Xu, J., & Ding, J. H. (2023) · Biotechnology Progress · doi:10.1002/btpr.3349 · Cited by 4
Ricciardi, V., Lasalvia, M., Perna, G., Portaccio, M., Delfino, I., Lepore, M. A., Capozzi, V., & Manti, L. (2023) · Radiation and Environmental Biophysics · doi:10.1007/s00411-023-01035-2 · Cited by 4
“Among the different univariate and multivariate data analysis procedures (Gautam et al. 2015; Xiabo et al. 2010) that are generally adopted in μ-FTIR, a particularly valuable role can be played by a ratiometric approach using the ratio between the intensity of properly selected peaks (Kumar et al.”
BackgroundMendes, T. D. O., Pinto, L. P., dos Santos, L., Tippavajhala, V. K., Soto, C. A. T., & Martin, A. A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.075010 · Cited by 4
“There are some approaches for outlier detection such as Hotelling T, Mahalanobis distance, and Chi-square distribution.(39,41) However, it is highlighted that it is not acceptable to remove any sample simply by considering it as an outlier.”
MethodLasalvia, M., Capozzi, V., & Perna, G. (2025) · Applied Sciences · doi:10.3390/app15084193 · Cited by 3
Kriukova, E., Mazurenka, M., Marcazzan, S., Tschurtschenthaler, M., Puppels, G. J., Glasl, S., Saur, D., Jesinghaus, M., Pouliou, M., Agelopoulos, M., et al. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c00954 · Cited by 3
Awasthi, A., Tripathi, A., Baran, C., & Uttam, K. N. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126963 · Cited by 3
Mirveis, Z., Patil, N., & Byrne, H. J. (2025) · The Analyst · doi:10.1039/d5an01114k · Cited by 3
Lasalvia, M., Capozzi, V., & Perna, G. (2026) · Applied Sciences · doi:10.3390/app16052380 · Cited by 3
Low-Frequency Raman Spectroscopy: Opportunities in Solid-State Modeling and Analysis
Remoto, P. I. J. G., & Gordon, K. C. (2026) · ACS Applied Optical Materials · doi:10.1021/acsaom.5c00643 · Cited by 6
Li, T., Beniwal, D., Dalal, R. C., Manning, S., Fu, P., Xia, A., Wu, J., Liu, Q., Filipović, V., Tsiminis, G., et al. (2026) · Soil and Tillage Research · doi:10.1016/j.still.2026.107237 · Cited by 3
Deshmukh, K. K., Nawale, S. P., Gurav, K. A., Dube, P. B., Keche, A. P., & Jadhav, K. M. (2026) · Crystal Research and Technology · doi:10.1002/crat.70112 · Cited by 3
“The recorded Raman spectra exhibited background noise; therefore, appropriate signal processing was applied to extract reliable vibrational information [ 70, 71 ].”
Dewanjee, U., Bai, S., Ryabchikov, Y. V., Fieser, D., Pradakshina, S., Wu, J. J., Fronzi, M., & Hu, A. (2026) · Nanomaterials · doi:10.3390/nano16100628 · Cited by 4
Physicochemical Stability of Dentin-Derived Biomaterials During Long-Term Storage
Dłucik, R., Scoglio, A., Puzzolo, D., Testagrossa, B., Alibrandi, A., Toscano, A., Orzechowska-Wylęgała, B., & Acri, G. (2026) · Journal of Functional Biomaterials · doi:10.3390/jfb17060284 · Cited by 3
“Raman spectra were normalized using the vector normalization method previously employed by the authors in [29,30].”
Palencia, M., & del Valle, U. (2020) · Journal of Science with Technological Applications · doi:10.34294/j.jsta.20.9.62 · Cited by 3
Analytical strategies for herbal Cannabis samples in forensic applications: A comprehensive review
Slosse, A., Durme, F. V., Eliaerts, J., Samyn, N., Mangelings, D., & Heyden, Y. V. (2023) · Wiley Interdisciplinary Reviews Forensic Science · doi:10.1002/wfs2.1479 · Cited by 3
Extracorporeal membrane oxygenation and effects on tendon tissue: A vibrational spectroscopy study
Stefani, S., Govoni, M., Tombolesi, N., Vivarelli, L., Dallari, D., Paolantoni, M., Sassi, P., & Morresi, A. (2023) · Journal of Biophotonics · doi:10.1002/jbio.202300163 · Cited by 3
Dinçtürk, E. (2024) · Animal Biotechnology · doi:10.1080/10495398.2023.2299733 · Cited by 3
Progressive Technology of InfraRed Spectroscopy for Characterization of Materials
Jaiswal, S., Bahadur, P. S., Singh, S., & Rajpoot, S. (2023) · International Conference on Contemporary Computing and Informatics (IC3I) · doi:10.1109/ic3i59117.2023.10397795 · Cited by 3
“The fresh data is converted into the anticipated outcomes of the sample's spectrum using a data-processing approach known as "Fourier transform" [24].”
MethodClassification of colorectal primer carcinoma from normal colon with mid‐infrared spectra
Borkovits, B., Kontsek, E., Pesti, A., Gordon, P., Gergely, S., Csabai, I., Kiss, A., & Pollner, P. (2024) · Journal of Chemometrics · doi:10.1002/cem.3542 · Cited by 3
“19 In this project, we first applied to the already preprocessed dataset two dimensionality reduction algorithms: principal component analysis (PCA) and t -distributed stochastic neighbor embedding ( t -SNE).”
Method
Metadata
- Authors
- Gautam, R., Vanga, S., Ariese, F., & Umapathy, S.
- Affiliations
- Indian Institute of Science Bangalore (IN)
- Venue
- EPJ Techniques and Instrumentation
- Published
- 2015-06-02
- Volume
- 2
- Issue
- 1
- ISSN
- 2195-7045 (ISSN-L)
- OpenAlex
- W1563946068
- Cited by
- 696
- References
- 97
- Citations by year
- 2026: 53 · 2025: 88 · 2024: 91 · 2023: 65 · 2022: 99 · 2021: 89 · 2020: 79 · 2019: 45 · 2018: 39 · 2017: 33 · 2016: 13 · 2015: 2
- FWCI
- 17.55
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- EPJ Techniques and Instrumentation (publishedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Indian Institute of Science
- Department of Biotechnology, Ministry of Science and Technology, India
- Department of Science and Technology, Ministry of Science and Technology, India
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Raman spectroscopy, infrared spectroscopy, Raman imaging, infrared imaging, multivariate analysis, spectral preprocessing, biological specimen, spectral interpretation, noise reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.