SeismoWatch: Wearable Cuffless Blood Pressure Monitoring Using Pulse Transit Time

Open access
Carek, Andrew M., Conant, Jordan, Joshi, Anirudh, Kang, Hyolim, Inan, Omer T. · 2017 · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Cited by 103

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

The current norm for measuring blood pressure (BP) at home is using an automated BP cuff based on oscillometry. Despite providing a viable and familiar method of tracking BP at home, oscillometric devices can be both cumbersome and inaccurate with the inconvenience of the hardware typically limiting measurements to once or twice per day. To address these limitations, a wrist-watch BP monitor was developed to measure BP through a simple maneuver: holding the watch against the sternum to detect micro-vibrations of the chest wall associated with the heartbeat. As a pulse wave propagates from the heart to the wrist, an accelerometer and optical sensor on the watch measure the travel time -- pulse transit time (PTT) -- to estimate BP. In this paper, we conducted a study to test the accuracy and repeatability of our device. After calibration, the diastolic pressure estimations reached a root-mean-square error of 2.9 mmHg. The watch-based system significantly outperformed (p<0.05) conventional pulse arrival time (PAT) based wearable blood pressure estimations -- the most commonly used method for wearable BP sensing in the existing literature and commercial devices. Our device can be a convenient means for wearable BP monitoring outside of clinical settings in both health-conscious and hypertensive populations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/3130905

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 103

Metadata

Authors
Carek, A. M., Conant, J., Joshi, A., Kang, H., & Inan, O. T.
Venue
Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Published
2017-09-11
Volume
1
Issue
3
Pages
1-16
ISSN
2474-9567 (ISSN-L)
OpenAlex
W2754008471
Cited by
103
References
12
FWCI
3.96
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SeismoWatch: Wearable Cuffless Blood Pressure Monitoring Using Pulse Transit Time. https://app.cochat.ai/papers/10.1145/3130905
The paper
Carek, A. M., Conant, J., Joshi, A., Kang, H., & Inan, O. T. (2017). SeismoWatch: Wearable Cuffless Blood Pressure Monitoring Using Pulse Transit Time. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies. https://doi.org/10.1145/3130905

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.