Raman Imaging
The DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
The past decade has seen an enormous increase in the number and breadth of imaging techniques developed for analysis in many industries, including pharmaceuticals, food, and especially biomedicine. Rather than accept single-dimensional forms of information, users now demand multidimensional assessment of samples. High specificity and the need for little or no sample preparation make Raman imaging a highly attractive analytical technique and provide motivation for continuing advances in its supporting technology and utilization. This review discusses the current tools employed in Raman imaging, the recent advances, and the major applications in this ever-growing analytical field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036 · cited 1×
“Over the past decade, compressive sampling techniques have been introduced primarily in the digital imaging community (68, 69); there have also been a few spectroscopic implementations (70–75).”
BackgroundCompressive Sensing [Lecture Notes]
Baraniuk, R. (2007) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.4286571 · Cited by 4,177
Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He, C., Tsai, J. C., Kang, J. X., & Xie, X. S. (2008) · Science · doi:10.1126/science.1165758 · Cited by 2,255
Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering
Zumbusch, A., Holtom, G. R., & Xie, X. S. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4142 · Cited by 1,626 · cited 1×
“(28), did the technology begin to generate real interest.”
BackgroundStudy of Optical Effects Due to an Induced Polarization Third Order in the Electric Field Strength
Maker, P. D., & Terhune, R. W. (1965) · Physical Review · doi:10.1103/physrev.137.a801 · Cited by 1,378 · cited 3×
“Maker PD, Terhune RW. 1965.”
MethodInfluentialCoherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
SERS—a single-molecule and nanoscale tool for bioanalytics
Kneipp, J., Kneipp, H., & Kneipp, K. (2008) · Chemical Society Reviews · doi:10.1039/b708459p · Cited by 1,075
Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Zavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714 · cited 2×
“In research reported by the Gambhir group (48, 54), SERS nanoparticles were injected into a live mouse and observed in the mouse’s liver through the collection of SERS mapped images through the skin.”
BackgroundMethodMicro-Raman Spectroscopy Detects Individual Neoplastic and Normal Hematopoietic Cells
Chan, J. W., Taylor, D. S., Zwerdling, T., Lane, S. M., Ihara, K., & Huser, T. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.066761 · Cited by 679
Noninvasive molecular imaging of small living subjects using Raman spectroscopy
Keren, S., Zavaleta, C., Cheng, Z., de la Zerda, A., Gheysens, O., & Gambhir, S. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710575105 · Cited by 604 · cited 2×
“In research reported by the Gambhir group (48, 54), SERS nanoparticles were injected into a live mouse and observed in the mouse’s liver through the collection of SERS mapped images through the skin.”
BackgroundMethodCoherent Nonlinear Optical Imaging: Beyond Fluorescence Microscopy
Min, W., Freudiger, C. W., Lu, S., & Xie, X. S. (2011) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103512 · Cited by 604 · cited 2×
“A significant limitation of CARS is the nonresonant background generated by the nonlinear electronic response of the sample mediated through virtual states (35).”
BackgroundSurface-Enhanced Raman Scattering – Physics and Applications
(2006) · Topics in Applied Physics · doi:10.1007/11663898 · Cited by 600
Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy
Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053641450 · Cited by 548 · cited 1×
“(59, 60), SORS was introduced as a means for retrieving Raman spectra of subsurface layers in”
MethodAnalytical applications of Raman spectroscopy
Kudelski, A. (2008) · Talanta · doi:10.1016/j.talanta.2008.02.042 · Cited by 455
Raman microprobe and microscope with laser excitation
Delhaye, M., & Dhamelincourt, P. (1975) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250030105 · Cited by 453 · cited 1×
“Assuming that there is a comparable laser power density to the point-mapping and line-scanning approaches as well as a square image, the experimentation-time relationships between wide-field and point-mapping and line-scanning approaches are as shown in Equations 1 and 2: Tw = (m n ) T p ; (1)”
BackgroundVibrational imaging based on stimulated Raman scattering microscopy
Nandakumar, P., Kovalev, A., & Volkmer, A. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/3/033026 · Cited by 401
Pharmaceutical applications of vibrational chemical imaging and chemometrics: A review
Gendrin, C., Roggo, Y., & Collet, C. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.08.014 · Cited by 350 · cited 1×
“Microscopic Raman imaging is an important analytical technique for measuring active pharmaceutical ingredient (API) heterogeneity in tablet cores, controlled release systems, and orally inhaled and nasal drug products (OINDPs) (3, 76).”
BackgroundNonresonant Confocal Raman Imaging of DNA and Protein Distribution in Apoptotic Cells
Uzunbajakava, N., Lenferink, A., Kraan, Y., Volokhina, E., Vrensen, G., Greve, J., & Otto, C. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75124-8 · Cited by 347
Multiplex Coherent Anti-Stokes Raman Scattering Microspectroscopy and Study of Lipid Vesicles
Cheng, J.-X., Volkmer, A., Book, L. D., & Xie, X. S. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp025771z · Cited by 342
Nan, X., Cheng, J.-X., & Xie, X. S. (2003) · Journal of Lipid Research · doi:10.1194/jlr.d300022-jlr200 · Cited by 311
Imaging the Thermodynamic State of Lipid Membranes with Multiplex CARS Microscopy
Müller, M., & Schins, J. M. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp014012y · Cited by 308
Novel Optical Properties and Emerging Applications of Metal Nanostructures
Schwartzberg, A. M., & Zhang, J. Z. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp801770w · Cited by 304
Coherent anti‐Stokes Raman Scattering Microscopy
Müller, M., & Zumbusch, A. (2007) · ChemPhysChem · doi:10.1002/cphc.200700202 · Cited by 277
Nanometer-Sized Diamond Particle as a Probe for Biolabeling
Chao, J.-I., Perevedentseva, E., Chung, P.-H., Liu, K.-K., Cheng, C.-Y., Chang, C.-C., & Cheng, C.-L. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.108134 · Cited by 268 · cited 1×
“(125) used nanometer-sized diamond particles as SERS probes to biolabel human lung epithelial cells.”
Label-Free Detection of Mitochondrial Distribution in Cells by Nonresonant Raman Microspectroscopy
Matthäus, C., Chernenko, T., Newmark, J. A., Warner, C. M., & Diem, M. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.102061 · Cited by 243
Chemically-selective imaging of brain structures with CARS microscopy
Evans, C. L., Xu, X., Kesari, S., Xie, X. S., Wong, S. T. C., & Young, G. S. (2007) · Optics Express · doi:10.1364/oe.15.012076 · Cited by 232
Nan, X., Potma, E. O., & Xie, X. S. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.074534 · Cited by 224
Noninvasive Raman Spectroscopy of Human Tissue in vivo
Matousek, P., Draper, E. R. C., Goodship, A. E., Clark, I. P., Ronayne, K. L., & Parker, A. W. (2006) · Applied Spectroscopy · doi:10.1366/000370206777886955 · Cited by 219 · cited 1×
“In other studies, the SORS signal was enhanced through the use of fiber optic bundles for Raman collection (62, 63).”
BackgroundMatousek, P., Morris, M. D., Everall, N., Clark, I. P., Towrie, M., Draper, E., Goodship, A., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/000370205775142548 · Cited by 209 · cited 1×
“(59, 60), SORS was introduced as a means for retrieving Raman spectra of subsurface layers in”
MethodFreudiger, C. W., Min, W., Holtom, G. R., Xu, B., Dantus, M., & Sunney Xie, X. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.294 · Cited by 188 · cited 1×
“The ability to perform such assignments makes SRS a more favorable technique for Raman imaging than CARS (42).”
MethodRaman Spectroscopic Imaging Markers for Fatigue-Related Microdamage in Bovine Bone
Timlin, J. A., Carden, A., Morris, M. D., Rajachar, R. M., & Kohn, D. H. (2000) · Analytical Chemistry · doi:10.1021/ac9913560 · Cited by 187 · cited 1×
“Line-scanned Raman images illustrate hydroxyapatite distribution in implants (92), bone maturity (93), and fatigue (94).”
BackgroundSurface enhanced spatially offset Raman spectroscopic (SESORS) imaging – the next dimension
Stone, N., Kerssens, M., Lloyd, G. R., Faulds, K., Graham, D., & Matousek, P. (2011) · Chemical Science · doi:10.1039/c0sc00570c · Cited by 183 · cited 1×
“(65, 66), who imaged SERS-active nanoparticles from porcine tissue to a depth of 20 mm.”
BackgroundLee, S., Chon, H., Lee, M., Choo, J., Shin, S. Y., Lee, Y. H., Rhyu, I. J., Son, S. W., & Oh, C. H. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.018 · Cited by 177 · cited 1×
“This methodology has been used to observe fungal cell growth (49), mammalian cells (50), bacterial cells (51), cancer markers (52, 53), and small live animals (48, 54).”
MethodNear infrared Raman spectroscopic mapping of native brain tissue and intracranial tumors
Krafft, C., Sobottka, S. B., Schackert, G., & Salzer, R. (2005) · The Analyst · doi:10.1039/b419232j · Cited by 164
Inverse Spatially Offset Raman Spectroscopy for Deep Noninvasive Probing of Turbid Media
Matousek, P. (2006) · Applied Spectroscopy · doi:10.1366/000370206778999102 · Cited by 160 · cited 1×
“In other studies, the SORS signal was enhanced through the use of fiber optic bundles for Raman collection (62, 63).”
BackgroundLégaré, F., Evans, C. L., Ganikhanov, F., & Xie, X. (2006) · Optics Express · doi:10.1364/oe.14.004427 · Cited by 157
Evans, J. (1958) · Journal of the Optical Society of America · doi:10.1364/josa.48.000142 · Cited by 149
Stone, N., Faulds, K., Graham, D., & Matousek, P. (2010) · Analytical Chemistry · doi:10.1021/ac100039c · Cited by 140 · cited 1×
“(65, 66), who imaged SERS-active nanoparticles from porcine tissue to a depth of 20 mm.”
BackgroundIn Situ Simultaneous Analysis of Polyacetylenes, Carotenoids and Polysaccharides in Carrot Roots
Barańśka, M., Schulz, H., Barański, R., Nothnagel, T., & Christensen, L. P. (2005) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0510440 · Cited by 137 · cited 1×
“) roots in order to understand the distribution of polyacetylene, carotenoid, and polysaccharide components (132).”
BackgroundHandbook of Raman Spectroscopy. From the Research Laboratory to the Process Line
Maes, G. (2002) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/s1386-1425(02)00113-0 · Cited by 130
Chemical imaging of drug eluting coatings: Combining surface analysis and confocal Raman microscopy
Belu, A. M., Mahoney, C. M., & Wormuth, K. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.11.015 · Cited by 125 · cited 1×
“Scanning and mapping Raman microscopy, in conjunction with chemometric techniques, has been utilized to determine the chemical distribution of rapamycin/PLGA [poly(lactic-co-glycolic acid)] coatings on stents (82) and of isoptin SR-E (Meltrex R ©) in an extrusion manufacturing process (83).”
MethodNoninvasive Raman tomographic imaging of canine bone tissue
Schulmerich, M. V., Cole, J. H., Dooley, K. A., Morris, M. D., Kreider, J. M., Goldstein, S. A., Srinivasan, S., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904940 · Cited by 119 · cited 1×
“A further variation couples transmission Raman measurements with microcomputed tomography and diffuse optical tomography to produce Raman tomographic images, which provide spatial and compositional information obtained from subsurface molecules (67).”
BackgroundVibrational imaging of tablets by epi-detected stimulated Raman scattering microscopy
Slipchenko, M. N., Chen, H., Ely, D. R., Jung, Y., Carvajal, M. T., & Cheng, J. (2010) · The Analyst · doi:10.1039/c0an00252f · Cited by 119 · cited 1×
“The SERS approach is 104 times faster than confocal Raman mapping and has a chemical selectivity superior to that of CARS imaging (81).”
BackgroundFiber delivered probe for efficient CARS imaging of tissues
Balu, M., Liu, G., Chen, Z., Tromberg, B. J., & Potma, E. O. (2010) · Optics Express · doi:10.1364/oe.18.002380 · Cited by 116
Puppels, G. J., Grond, M., & Greve, J. (1993) · Applied Spectroscopy · doi:10.1366/0003702934068017 · Cited by 105 · cited 1×
“Various wide-field Raman imaging instrumental developments have occurred over the past two decades; these developments include tunable lasers and fixed (10) or rotating (6) dielectric filters, acousto-optic tunable filters (9, 11–13), liquid crystal tunable filters (LCTFs) (9, 14), and fiber array assemblies (15–19).”
BackgroundRaman Chemical Imaging of Breast Tissue
Kline, N. J., & Treado, P. J. (1997) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199702)28:2/3<119::aid-jrs73>3.0.co;2-3 · Cited by 104 · cited 1×
“In one of the earliest reports, Raman images were used to assess lipid and protein distribution in chicken tissue (91).”
BackgroundSelf-citationLabel-free quantitative analysis of lipid metabolism in living Caenorhabditis elegans
Le, T. T., Duren, H. M., Slipchenko, M. N., Hu, C., & Cheng, J. (2009) · Journal of Lipid Research · doi:10.1194/jlr.d000638 · Cited by 103
An In-Depth Analysis of Raman and Near-Infrared Chemical Images of Common Pharmaceutical Tablets
Šašić, S. (2007) · Applied Spectroscopy · doi:10.1366/000370207780220769 · Cited by 102 · cited 1×
“Raman imaging performs better than NIR imaging for the analysis of common pharmaceutical tablets and granules (78, 79); detection levels as low as 0.”
BackgroundMicro-Raman spectroscopy of mixed cancer cell populations
Krishna, C. M., Sockalingum, G. D., Kegelaer, G., Rubin, S., Kartha, V. B., & Manfait, M. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.02.018 · Cited by 93
Multivariate Hyperspectral Raman Imaging Using Compressive Detection
Davis, B. M., Hemphill, A. J., Maltaş, D. C., Zipper, M. A., Wang, P., & Ben‐Amotz, D. (2011) · Analytical Chemistry · doi:10.1021/ac103259v · Cited by 91 · cited 1×
“(75) recently described a point-mapping implementation of multivariate hyperspectral Raman imaging based on compressive detection.”
BackgroundFujita, K., Ishitobi, S., Hamada, K., Smith, N. I., Taguchi, A., Inouye, Y., & Kawata, S. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3119242 · Cited by 83 · cited 1×
“This methodology has been used to observe fungal cell growth (49), mammalian cells (50), bacterial cells (51), cancer markers (52, 53), and small live animals (48, 54).”
MethodRapid Micro-Raman Imaging Using Fiber-Bundle Image Compression
Ma, J., & Ben‐Amotz, D. (1997) · Applied Spectroscopy · doi:10.1366/0003702971939668 · Cited by 82 · cited 1×
“Names for this technology include fiber array spectral translation (FAST) (26), dimension-reduction arrays (16–18), and fiber image compression (19).”
BackgroundSurface vibrational spectroscopy using stimulated Raman scattering
Levine, B. F., Shank, C. V., & Heritage, J. P. (1979) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1979.1069939 · Cited by 75
Raman imaging of floating cells
Creely, C. M., Volpe, G., Singh, G., Soler, M., & Petrov, D. V. (2005) · Optics Express · doi:10.1364/opex.13.006105 · Cited by 72 · cited 1×
“Advances in optical trapping technology have enabled the collection of Raman mapped images of living cells in suspension (101).”
BackgroundRaman spectroscopy and chemical imaging for quantification of filtered waterborne bacteria
Escoriza, M. F., VanBriesen, J. M., Stewart, S. D., Maier, J., & Treado, P. J. (2005) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2005.10.013 · Cited by 72
Self-citationDeep Noninvasive Raman Spectroscopy of Turbid Media
Macleod, N. A., & Matousek, P. (2008) · Applied Spectroscopy · doi:10.1366/000370208786401527 · Cited by 65 · cited 1×
“Because Raman and fluorescence components from the same layer have identical spatial distributions, SORS effectively discriminates against surface layer–generated fluorescence emission (61).”
BackgroundVajna, B., Pataki, H., Nagy, Z. K., Farkas, I., & Marosi, G. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.07.023 · Cited by 61 · cited 1×
“Scanning and mapping Raman microscopy, in conjunction with chemometric techniques, has been utilized to determine the chemical distribution of rapamycin/PLGA [poly(lactic-co-glycolic acid)] coatings on stents (82) and of isoptin SR-E (Meltrex R ©) in an extrusion manufacturing process (83).”
MethodLabel-free imaging of biomolecules in food products using stimulated Raman microscopy
Roeffaers, M. B. J., Zhang, X., Freudiger, C. W., Saar, B. G., Xie, X. S., van Dalen, G., van Dalen, G., & Xiao, C. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3516591 · Cited by 56 · cited 1×
“Recently, emulsion interfaces were studied in mayonnaise, cheese, and soy-based beverages (134).”
BackgroundCoherent Anti-Stokes Raman Scattering Microscopy of Cellular Lipid Storage
Enejder, A. M. K., Brackmann, C., & Svedberg, F. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2032512 · Cited by 53 · cited 1×
“These methods are highly sensitive to CH2-rich molecular structures (29, 106–111) and thus have been extensively applied to lipid-based systems in cells (107, 112–114), tissues (115, 116), and whole organisms (117, 118).”
MethodLevenson, M. D., & Kano, S. S. (1988) · Elsevier eBooks · doi:10.1016/b978-0-12-444722-6.50008-0 · Cited by 49
Vibrational Spectroscopic Imaging for Biomedical Applications
Srinivasan, G. (2010) · Cited by 49
Šašić, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.01.063 · Cited by 47 · cited 1×
“Raman imaging performs better than NIR imaging for the analysis of common pharmaceutical tablets and granules (78, 79); detection levels as low as 0.”
BackgroundSurface-Enhanced Raman Imaging of Intracellular Bioreduction of Chromate in Shewanella oneidensis
Ravindranath, S. P., Henne, K. L., Thompson, D. K., & Irudayaraj, J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016634 · Cited by 46 · cited 2×
“Metabolism in bacterial cells (51) and growth of fungal cells have been observed with the use of SERS imaging (49).”
BackgroundMethodChasing lipids in health and diseases by coherent anti-Stokes Raman scattering microscopy
Wang, H.-W., Fu, Y., Huff, T. B., Le, T. T., Wang, H., & Cheng, J. (2008) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2008.11.007 · Cited by 46 · cited 1×
“These methods are highly sensitive to CH2-rich molecular structures (29, 106–111) and thus have been extensively applied to lipid-based systems in cells (107, 112–114), tissues (115, 116), and whole organisms (117, 118).”
MethodLiu, Y., Chao, K., Kim, M. S., Tuschel, D. D., Olkhovyk, O., & Priore, R. J. (2009) · Applied Spectroscopy · doi:10.1366/000370209787944398 · Cited by 45 · cited 2×
“The melamine in the wheat flour mixture was prepared and supplied to the ChemImage Corporation by the U.S. Department of Agriculture, Agricultural Research Service (136).”
Self-citationA versatile CARS microscope for biological imaging
Downes, A., Mouras, R., & Elfick, A. P. D. (2009) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2249 · Cited by 42
Deep Subsurface Raman Spectroscopy of Turbid Media by a Defocused Collection System
Eliasson, C., Claybourn, M., & Matousek, P. (2007) · Applied Spectroscopy · doi:10.1366/000370207782217770 · Cited by 41 · cited 1×
“(64) demonstrated a simpler variation of SORS by defocusing the collection optics of a Raman system.”
BackgroundIn vivo optical monitoring of tissue pathologies and diseases with vibrational contrast
Bégin, S., Bélanger, E., Laffray, S., Vallée, R., & Côté, D. C. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910071 · Cited by 39 · cited 1×
“These methods are highly sensitive to CH2-rich molecular structures (29, 106–111) and thus have been extensively applied to lipid-based systems in cells (107, 112–114), tissues (115, 116), and whole organisms (117, 118).”
MethodWang, Z., Gao, L. S., Luo, P., Yang, Y., Hammoudi, A. A., Wong, K., & Wong, S. T. C. (2011) · Optics Express · doi:10.1364/oe.19.007960 · Cited by 31 · cited 1×
“Biomedical applications have been widely investigated with coherent Raman scattering approaches (33).”
BackgroundDelivery of picosecond lasers in multimode fibers for coherent anti-Stokes Raman scattering imaging
Wang, Z., Yang, Y., Luo, P., Gao, L. S., Wong, K., & Wong, S. T. C. (2010) · Optics Express · doi:10.1364/oe.18.013017 · Cited by 18
Cheng, S., Tjahjono, M., Dharmarajan, R., Li, C., Lyapkalo, I. M., Chen, D., & Garland, M. (2007) · Applied Spectroscopy · doi:10.1366/000370207782217734 · Cited by 16
Nelson, M. P., & Treado, P. J. (2010) · Wiley eBooks · doi:10.1002/9780470768150.ch2 · Cited by 14 · cited 1×
“Spatial distributions of the three ingredients (aspirin, acetaminophen, and caffeine) were generated through the use of a direct classical least squares model applied to the spectroscopic data (77).”
MethodSelf-citationRaman spectroscopy and Raman chemical imaging of apoptotic cells
Panza, J. L., & Maier, J. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.701219 · Cited by 5 · cited 1×
“Wide-field Raman imaging has been used to demonstrate mammalian cell viability (99) and three-dimensional profiling of a single cell (100).”
MethodStandoff Raman Hyperspectral Imaging Detection of Explosives
Treado, P. J., Nelson, M. P., Schweitzer, B., et al. (2008) · Laser Applications to Chemical, Security and Environmental Analysis · doi:10.1364/lacsea.2008.lthb1 · Cited by 4 · cited 9×
“Through the use of FAST technology, a total of 3,672 spectra were collected in 20 min over 225 cm2.”
BackgroundMethodInfluentialSelf-citationMapping of single cells by near infrared Raman microspectroscopy
Krafft, C., Knetschke, T., Siegner, A., Funk, R. H. W., & Salzer, R. (2003) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(03)00049-3
Nonresonant Raman imaging of protein distribution in single human cells
Uzunbajakava, N. E., Lenferink, A. T. M., Kraan, Y. M., Willekens, B., Vrensen, G. F. J. M., Greve, J., & Otto, C. (2002) · Biopolymers · doi:10.1002/bip.10246
Cited by
Surface-Enhanced Raman Spectroscopy for Bioanalysis: Reliability and Challenges
Zong, C., Xu, M., Xu, L.-J., Wei, T., Ma, X., Zheng, X.-S., Hu, R., & Ren, B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00668 · Cited by 1,934
Identification of microplastics using Raman spectroscopy: Latest developments and future prospects
Araujo, C. F., Nolasco, M. M., Ribeiro, A. M. P., & Ribeiro-Claro, P. J. A. (2018) · Water Research · doi:10.1016/j.watres.2018.05.060 · Cited by 1,059
Evolving trends in SERS-based techniques for food quality and safety: A review
Jiang, L., Hassan, M. M., Ali, S., Li, H., Sheng, R., & Chen, Q. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.04.006 · Cited by 470
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Raman microspectroscopy as a tool for microplastic particle analysis
Anger, P. M., von der Esch, E., Baumann, T., Elsner, M., Niessner, R., & Ivleva, N. P. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.10.010 · Cited by 341
Metadata
- Authors
- Stewart, S., Priore, R. J., Nelson, M. P., & Treado, P. J.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2012-07-19
- Volume
- 5
- Issue
- 1
- Pages
- 337-360
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W4250278035
- Cited by
- 184
- References
- 79
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.