X-Ray Free-Electron Lasers for the Structure and Dynamics of Macromolecules
Open accessThe DOI matches its Crossref record; 132 of the 132 references it cites were found in a registry or an index.
Abstract
X-ray free-electron lasers provide femtosecond-duration pulses of hard X-rays with a peak brightness approximately one billion times greater than is available at synchrotron radiation facilities. One motivation for the development of such X-ray sources was the proposal to obtain structures of macromolecules, macromolecular complexes, and virus particles, without the need for crystallization, through diffraction measurements of single noncrystalline objects. Initial explorations of this idea and of outrunning radiation damage with femtosecond pulses led to the development of serial crystallography and the ability to obtain high-resolution structures of small crystals without the need for cryogenic cooling. This technique allows the understanding of conformational dynamics and enzymatics and the resolution of intermediate states in reactions over timescales of 100 fs to minutes. The promise of more photons per atom recorded in a diffraction pattern than electrons per atom contributing to an electron micrograph may enable diffraction measurements of single molecules, although challenges remain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berman, H. M. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.1.235 · Cited by 40,196
First lasing and operation of an ångstrom-wavelength free-electron laser
Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167
Femtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086
Self-citationPotential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 4×
“Themeetingmay have stimulated new thoughts, however, since by Christmas of that year Hajdu and colleagues submitted a paper (18) proposing a scheme to achieve structure determination from a series of FEL diffraction measurements of single molecules.”
BackgroundInfluentialColloquium: Aligning molecules with strong laser pulses
Stapelfeldt, H., & Seideman, T. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.543 · Cited by 1,790 · cited 1×
“Nonspherical objects align theirmajor axes parallel to the flow of amicrojet (134), similar to the one-dimensional alignment of polarizable molecules using optical laser fields (45, 135, 136).”
BackgroundOperation of a free-electron laser from the extreme ultraviolet to the water window
Ackermann, W., Asova, G., Ayvazyan, V., Azima, A., Baboi, N., Bähr, J., Balandin, V., Beutner, B., Brandt, A., Bolzmann, A., et al. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.76 · Cited by 1,642 · cited 1×
“The investigation of radiation damage at much higher exposure levels (and doses) had to wait until 2005, when the first soft X-ray FEL, at the TESLA Test Facility at DESY in Hamburg, Germany, opened as a user facility (31).”
BackgroundNative structure of photosystem II at 1.95 Å resolution viewed by femtosecond X-ray pulses
Suga, M., Akita, F., Hirata, K., Ueno, G., Murakami, H., Nakajima, Y., Shimizu, T., Yamashita, K., Yamamoto, M., Ago, H., et al. (2015) · Nature · doi:10.1038/nature13991 · Cited by 1,192 · cited 1×
“Over longer timescales, intermediate structures of photosystem II undergoing the water splitting reaction were captured, and efforts to understand this important system are continuing within three different collaborative efforts (68, 69, 90).”
BackgroundFemtosecond diffractive imaging with a soft-X-ray free-electron laser
Chapman, H. N., Barty, A., Bogan, M. J., Boutet, S., Frank, M., Hau-Riege, S. P., Marchesini, S., Woods, B. W., Bajt, S., Benner, W. H., et al. (2006) · Nature Physics · doi:10.1038/nphys461 · Cited by 1,026 · cited 1×
“They recorded a coherent diffraction pattern of a test object—a design etched into a 20 nm thick silicon nitride membrane—with a single 25 fs duration pulse of 32 nm wavelength, focused to a power density of 4 × 1014 W cm−2 (38).”
BackgroundSelf-citationSingle mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904 · cited 2×
“The second week of the extraordinaryDecember 2009 run at LCLSwas devoted to the original scope of imaging aerosolized noncrystalline particles, such as mimi viruses, using an aerodynamic lens built at Uppsala University to stream them across the XFEL beam (53).”
MethodSelf-citationHigh-Resolution Protein Structure Determination by Serial Femtosecond Crystallography
Boutet, S., Lomb, L., Williams, G. J., Barends, T. R. M., Aquila, A., Doak, R. B., Weierstall, U., DePonte, D. P., Steinbrener, J., Shoeman, R. L., et al. (2012) · Science · doi:10.1126/science.1217737 · Cited by 857 · cited 1×
“9 Å (58), clearly indicated that X-ray FEL pulses could be utilized effectively for structure determination from small crystals at the functional temperature of their constituent molecules.”
BackgroundSelf-citationLipidic cubic phase injector facilitates membrane protein serial femtosecond crystallography
Weierstall, U., James, D., Wang, C., White, T. A., Wang, D., Liu, W., Spence, J. C. H., Bruce Doak, R., Nelson, G., Fromme, P., et al. (2014) · Nature Communications · doi:10.1038/ncomms4309 · Cited by 583 · cited 1×
“Weierstall and colleagues at ASU developed a nozzle that extrudes the highly viscous LCP material across the beam, which has been used to solve many GPCR structures (74).”
BackgroundSelf-citationCrystFEL: a software suite for snapshot serial crystallography
White, T. A., Kirian, R. A., Martin, A. V., Aquila, A., Nass, K., Barty, A., & Chapman, H. N. (2012) · Journal of Applied Crystallography · doi:10.1107/s0021889812002312 · Cited by 535 · cited 5×
“The approach was referred to as a Monte Carlo integration of the full Bragg reflections (60), although observed peak profiles and estimations of partiality were quickly adopted into a software suite called CrystFEL (61) to achieve higher accuracy than that simple integration method.”
MethodInfluentialSelf-citationStructures of the intermediates of Kok’s photosynthetic water oxidation clock
Kern, J., Chatterjee, R., Young, I. D., Fuller, F. D., Lassalle, L., Ibrahim, M., Gul, S., Fransson, T., Brewster, A. S., Alonso-Mori, R., et al. (2018) · Nature · doi:10.1038/s41586-018-0681-2 · Cited by 520
Tenboer, J., Basu, S., Zatsepin, N., Pande, K., Milathianaki, D., Frank, M., Hunter, M., Boutet, S., Williams, G. J., Koglin, J. E., et al. (2014) · Science · doi:10.1126/science.1259357 · Cited by 508
Self-citationGas dynamic virtual nozzle for generation of microscopic droplet streams
DePonte, D. P., Weierstall, U., Schmidt, K., Warner, J., Starodub, D., Spence, J. C. H., & Doak, R. B. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/19/195505 · Cited by 501 · cited 1×
“By the time of the LCLS opening, the ASU team had adopted a design of a coaxial sheath of gas that focused the liquid into a jet much thinner than the nozzle opening (47, 48) to reduce the background scattering.”
MethodSerial time-resolved crystallography of photosystem II using a femtosecond X-ray laser
Kupitz, C., Basu, S., Grotjohann, I., Fromme, R., Zatsepin, N. A., Rendek, K. N., Hunter, M. S., Shoeman, R. L., White, T. A., Wang, D., et al. (2014) · Nature · doi:10.1038/nature13453 · Cited by 477 · cited 1×
“Over longer timescales, intermediate structures of photosystem II undergoing the water splitting reaction were captured, and efforts to understand this important system are continuing within three different collaborative efforts (68, 69, 90).”
BackgroundSelf-citationSerial Femtosecond Crystallography of G Protein–Coupled Receptors
Liu, W., Wacker, D., Gati, C., Han, G. W., James, D., Wang, D., Nelson, G., Weierstall, U., Katritch, V., Barty, A., et al. (2013) · Science · doi:10.1126/science.1244142 · Cited by 455
Self-citationFemtosecond structural dynamics drives the trans/cis isomerization in photoactive yellow protein
Pande, K., Hutchison, C. D. M., Groenhof, G., Aquila, A., Robinson, J. S., Tenboer, J., Basu, S., Boutet, S., DePonte, D. P., Liang, M., et al. (2016) · Science · doi:10.1126/science.aad5081 · Cited by 446 · cited 1×
“In this way, the isomerization of the chromophore in photoactive yellow protein was observed to occur within 590 fs (88), and dynamics at a similar timescale were observed in rhodopsin prior to isomerization (89).”
BackgroundSelf-citationNatively Inhibited Trypanosoma brucei Cathepsin B Structure Determined by Using an X-ray Laser
Redecke, L., Nass, K., DePonte, D. P., White, T. A., Rehders, D., Barty, A., Stellato, F., Liang, M., Barends, T. R. M., Boutet, S., et al. (2013) · Science · doi:10.1126/science.1229663 · Cited by 440 · cited 1×
“Some of the first applications of serial crystallography obtained structures from small crystals, such as those of cathepsin B (65) grown in living cells, natural mosquito larvacide crystals found in spores (66), and another pesticide called granulovirus that forms a crystalline shell around the viral body (33).”
BackgroundSelf-citationSimultaneous Femtosecond X-ray Spectroscopy and Diffraction of Photosystem II at Room Temperature
Kern, J., Alonso-Mori, R., Tran, R., Hattne, J., Gildea, R. J., Echols, N., Glöckner, C., Hellmich, J., Laksmono, H., Sierra, R. G., et al. (2013) · Science · doi:10.1126/science.1234273 · Cited by 440
Disentangling conformational states of macromolecules in 3D-EM through likelihood optimization
Scheres, S. H. W., Gao, H., Valle, M., Herman, G. T., Eggermont, P. P. B., Frank, J., & Carazo, J.-M. (2007) · Nature Methods · doi:10.1038/nmeth992 · Cited by 407 · cited 2×
“The algorithms to achieve this—EMC and manifold embedding—are conceptually similar when applied to realspace data of electron microscopy or reciprocal-space data of diffraction (113, 146).”
MethodRetinal isomerization in bacteriorhodopsin captured by a femtosecond x-ray laser
Nogly, P., Weinert, T., James, D., Carbajo, S., Ozerov, D., Furrer, A., Gashi, D., Borin, V., Skopintsev, P., Jaeger, K., et al. (2018) · Science · doi:10.1126/science.aat0094 · Cited by 383 · cited 1×
“In this way, the isomerization of the chromophore in photoactive yellow protein was observed to occur within 590 fs (88), and dynamics at a similar timescale were observed in rhodopsin prior to isomerization (89).”
BackgroundAchieving few-femtosecond time-sorting at hard X-ray free-electron lasers
Harmand, M., Coffee, R., Bionta, M. R., Chollet, M., French, D., Zhu, D., Fritz, D. M., Lemke, H. T., Medvedev, N., Ziaja, B., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.11 · Cited by 376 · cited 1×
“Although the synchronization between the the arrival of the optical laser pulse (to trigger the photoreaction) and that of the X-ray pulse (to measure the diffraction) fluctuated by 100 fs or more, methods were developed to precisely measure the delay on each pulse (87) to piece together a time series from the inheren…”
MethodExperimental determination of the radiation dose limit for cryocooled protein crystals
Owen, R. L., Rudiño-Piñera, E., & Garman, E. F. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600973103 · Cited by 356
Self-terminating diffraction gates femtosecond X-ray nanocrystallography measurements
Barty, A., Caleman, C., Aquila, A., Timneanu, N., Lomb, L., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2011.297 · Cited by 344 · cited 1×
“This presented a puzzle: How could structural information survive such long pulses? The answer was that, during the initial moments of the pulse, prior to the onset of disorder, constructive interference to create Bragg peaks could occur (50).”
BackgroundSelf-citationThree-Dimensional Reconstruction of the Giant Mimivirus Particle with an X-Ray Free-Electron Laser
Ekeberg, T., Svenda, M., Abergel, C., Maia, F. R. N. C., Seltzer, V., Claverie, J.-M., Hantke, M., Jönsson, O., Nettelblad, C., van der Schot, G., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.098102 · Cited by 344
Self-citationStrüder, L., Epp, S., Rolles, D., Hartmann, R., Holl, P., Lutz, G., Soltau, H., Eckart, R., Reich, C., Heinzinger, K., et al. (2010) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2009.12.053 · Cited by 306 · cited 2×
“An instrument containing two such detector planes in vacuum, built by the Max Planck Society, was made available by Joachim Ulrich and Ilme Schlichting to the Atomic and Molecular Optics (AMO) beamline of LCLS, where the first beam would be delivered (44).”
BackgroundMethodStructures of riboswitch RNA reaction states by mix-and-inject XFEL serial crystallography
Stagno, J. R., Liu, Y., Bhandari, Y. R., Conrad, C. E., Panja, S., Swain, M., Fan, L., Nelson, G., Li, C., Wendel, D. R., et al. (2017) · Nature · doi:10.1038/nature20599 · Cited by 302 · cited 3×
“After mixing, the crystals changed form from P21 symmetry to P212121 (91).”
BackgroundSelf-citationReconstruction algorithm for single-particle diffraction imaging experiments
Loh, N.-T. D., & Elser, V. (2009) · Physical Review E · doi:10.1103/physreve.80.026705 · Cited by 292
Recent developments in CrystFEL
White, T. A., Mariani, V., Brehm, W., et al. (2016) · Journal of Applied Crystallography · doi:10.1107/s1600576716004751 · Cited by 287 · cited 1×
“CrystFEL is widely used and actively being developed today (62) and has been joined by other software projects (63, 64).”
MethodMacromolecular Cryocrystallography
Garman, E. F., & Schneider, T. R. (1997) · Journal of Applied Crystallography · doi:10.1107/s0021889897002677 · Cited by 274
De novo protein crystal structure determination from X-ray free-electron laser data
Barends, T. R. M., Foucar, L., Botha, S., Doak, R. B., Shoeman, R. L., Nass, K., Koglin, J. E., Williams, G. J., Boutet, S., Messerschmidt, M., et al. (2014) · Nature · doi:10.1038/nature12773 · Cited by 266
Kameshima, T., Ono, S., Kudo, T., Ozaki, K., Kirihara, Y., Kobayashi, K., Inubushi, Y., Yabashi, M., Horigome, T., Holland, A., et al. (2014) · Review of Scientific Instruments · doi:10.1063/1.4867668 · Cited by 262 · cited 1×
“Experiences with different detector systems [which necessarily all employ cutting-edge technologies (44, 84, 123, 124)] suggest that the noise and gain characteristics of these systems impact data quality and that significant improvements can be expected.”
BackgroundFemtosecond time-delay X-ray holography
Chapman, H. N., Hau-Riege, S. P., Bogan, M. J., Bajt, S., Barty, A., Boutet, S., Marchesini, S., Frank, M., Woods, B. W., Benner, W. H., et al. (2007) · Nature · doi:10.1038/nature06049 · Cited by 262 · cited 1×
“the test to 3 nm precision (40), showing particle expansions below 6 nm in 350 fs, at an X-ray dose of approximately 500 MGy, in agreement with hydrodynamic models.”
MethodSelf-citationTime-resolved protein nanocrystallography using an X-ray free-electron laser
Aquila, A., Hunter, M. S., Doak, R. B., Kirian, R. A., Fromme, P., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., et al. (2012) · Optics Express · doi:10.1364/oe.20.002706 · Cited by 260 · cited 1×
“Opportunities for time-resolved serial crystallography began to be explored once it was clear that small changes of structure factors could be measured by serial crystallography (85, 86).”
BackgroundSelf-citationRoom-temperature macromolecular serial crystallography using synchrotron radiation
Stellato, F., Oberthür, D., Liang, M., Bean, R., Gati, C., Yefanov, O., Barty, A., Burkhardt, A., Fischer, P., Galli, L., et al. (2014) · IUCrJ · doi:10.1107/s2052252514010070 · Cited by 256 · cited 1×
“The dose was reduced even further for room-temperature measurements (96) at exposure times of 3 ms, creating the opportunity to use the mix-and-inject style of measurement of structural kinetics (97).”
BackgroundSelf-citationDetermination of damage-free crystal structure of an X-ray–sensitive protein using an XFEL
Hirata, K., Shinzawa-Itoh, K., Yano, N., Takemura, S., Kato, K., Hatanaka, M., Muramoto, K., Kawahara, T., Tsukihara, T., Yamashita, E., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2962 · Cited by 253
Short-wavelength free-electron laser sources and science: a review
Seddon, E. A., Clarke, J. A., Dunning, D. J., Masciovecchio, C., Milne, C. J., Parmigiani, F., Rugg, D., Spence, J. C. H., Thompson, N. R., Ueda, K., et al. (2017) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa7cca · Cited by 252 · cited 1×
“With the development of X-ray free-electron lasers (FELs) (8) (see sidebar titled X-Rays from Linear Accelerators), which produce brief and intense flashes of X-rays, another strategy became available for avoiding the effects of radiation damage, with the potential to match signal levels achievable in cryo-electron mi…”
BackgroundSingle Particle X-ray Diffractive Imaging
Bogan, M. J., Benner, W. H., Boutet, S., Rohner, U., Frank, M., Barty, A., Seibert, M. M., Maia, F., Marchesini, S., Bajt, S., et al. (2008) · Nano Letters · doi:10.1021/nl072728k · Cited by 250 · cited 15×
“Later renamed FLASH, this facility could generate thousands of high-intensity femtosecond-duration soft X-ray pulses per second rather than one Nova pulse every few hours (32).”
MethodInfluentialSelf-citationKühlbrandt, W. (2014) · eLife · doi:10.7554/elife.03678 · Cited by 247 · cited 1×
“This conclusion is based on an analysis method described in [7].”
MethodTrajectories of the ribosome as a Brownian nanomachine
Dashti, A., Schwander, P., Langlois, R., Fung, R., Li, W., Hosseinizadeh, A., Liao, H. Y., Pallesen, J., Sharma, G., Stupina, V. A., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1419276111 · Cited by 243 · cited 2×
“Ourmazd and colleagues introduced the ability not only to sort conformations but also to determine their principle components (146).”
BackgroundMethodDiffraction before destruction
Chapman, H. N., Caleman, C., & Timneanu, N. (2014) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2013.0313 · Cited by 241 · cited 1×
“For a typical protein, this corresponds to a dose of approximately 400MGy (26).”
BackgroundSelf-citationSerial crystallography on in vivo grown microcrystals using synchrotron radiation
Gati, C., Bourenkov, G., Klinge, M., Rehders, D., Stellato, F., Oberthür, D., Yefanov, O., Sommer, B. P., Mogk, S., Duszenko, M., et al. (2014) · IUCrJ · doi:10.1107/s2052252513033939 · Cited by 226 · cited 1×
“This strategy was first demonstrated using synchrotron radiation on cryogenically cooled, in vivo–grown crystals of cathepsin B, which were initially thought to be too small for such a facility (95).”
BackgroundSelf-citationThe crystalline sponge method updated
Hoshino, M., Khutia, A., Xing, H., Inokuma, Y., & Fujita, M. (2016) · IUCrJ · doi:10.1107/s2052252515024379 · Cited by 223 · cited 1×
“Such crystals may provide a suitable platform for further developments of algorithms or preparation of host–guest systems (145) for the study of of small proteins.”
BackgroundStructure and conformational dynamics of the human spliceosomal Bact complex
Haselbach, D., Komarov, I., Agafonov, D. E., Hartmuth, K., Graf, B., Dybkov, O., Urlaub, H., Kastner, B., Lührmann, R., & Stark, H. (2018) · Cell · doi:10.1016/j.cell.2018.01.010 · Cited by 218
Lipidic cubic phase serial millisecond crystallography using synchrotron radiation
Nogly, P., James, D., Wang, D., White, T. A., Zatsepin, N., Shilova, A., Nelson, G., Liu, H., Johansson, L., Heymann, M., et al. (2015) · IUCrJ · doi:10.1107/s2052252514026487 · Cited by 217
Self-citationBotha, S., Nass, K., Barends, T. R. M., Kabsch, W., Latz, B., Dworkowski, F., Foucar, L., Panepucci, E., Wang, M., Shoeman, R. L., et al. (2015) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s1399004714026327 · Cited by 215
Impact of hollow-atom formation on coherent x-ray scattering at high intensity
Son, S.-K., Young, L., & Santra, R. (2011) · Physical Review A · doi:10.1103/physreva.83.033402 · Cited by 212 · cited 3×
“Reducing the photon energy to 4 keV would give a factor of four times higher scattering cross section, σ , and a factor of two more photons from the FEL, to reach the scattering saturation regime discussed above (23), with approximately 0.”
BackgroundInfluentialThe linac coherent light source single particle imaging road map
Aquila, A., Barty, A., Bostedt, C., Boutet, S., Carini, G., dePonte, D., Drell, P., Doniach, S., Downing, K. H., Earnest, T., et al. (2015) · Structural Dynamics · doi:10.1063/1.4918726 · Cited by 210 · cited 1×
“Steady development of the method has since been continued at LCLS and SACLA, greatly helped by the Single Particle Initiative—a community effort carried out under the auspices of the LCLS facility (54, 55)—as discussed further in the final section.”
MethodFixed-target protein serial microcrystallography with an x-ray free electron laser
Hunter, M. S., Segelke, B., Messerschmidt, M., Williams, G. J., Zatsepin, N. A., Barty, A., Benner, W. H., Carlson, D. B., Coleman, M., Graf, A., et al. (2014) · Scientific Reports · doi:10.1038/srep06026 · Cited by 206 · cited 1×
“Two promising methods are focused aerosol particle injectors, of the kind that have been used since the first FLASH experiments (41, 53, 128), and thin solid supports, such as graphene, that can be scanned through the beam (109, 129, 130).”
MethodFemtosecond protein nanocrystallography—data analysis methods
Kirian, R. A., Wang, X., Weierstall, U., Schmidt, K. E., Spence, J. C. H., Hunter, M., Fromme, P., White, T., Chapman, H. N., & Holton, J. (2010) · Optics Express · doi:10.1364/oe.18.005713 · Cited by 204 · cited 2×
“This approach was referred to as a Monte Carlo integration of the full Bragg reflections (60), although observed peak profiles and estimations of partiality were quickly adopted into a software suite called CrystFEL (61) to achieve higher accuracy than that of the simple integration method.”
MethodSelf-citationMegahertz serial crystallography
Wiedorn, M. O., Oberthür, D., Bean, R., Schubert, R., Werner, N., Abbey, B., Aepfelbacher, M., Adriano, L., Allahgholi, A., Al-Qudami, N., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06156-7 · Cited by 201
Self-citationKeedy, D. A., Kenner, L. R., Warkentin, M., Woldeyes, R. A., Hopkins, J. B., Thompson, M. C., Brewster, A. S., Van Benschoten, A. H., Baxter, E. L., Uervirojnangkoorn, M., et al. (2015) · eLife · doi:10.7554/elife.07574 · Cited by 191
Overview of the SACLA facility
Yabashi, M., Tanaka, H. N., & Ishikawa, T. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515004658 · Cited by 187 · cited 1×
“019, and the average real-space error [20] was 0.”
BackgroundRadiation damage in protein serial femtosecond crystallography using an x-ray free-electron laser
Lomb, L., Barends, T. R. M., Kassemeyer, S., Aquila, A., Epp, S. W., Erk, B., Foucar, L., Hartmann, R., Rudek, B., Rolles, D., et al. (2011) · Physical Review B · doi:10.1103/physrevb.84.214111 · Cited by 180 · cited 1×
“The second sample tried in the same week of LCLS beamtime, lysozyme nanocrystals produced by Ilme Schlichting, showed a more complicated response (51), and measurements made at shorter wavelengths showed that specific atoms, such as those surrounding a heavy atom (which is thus strongly ionizing), can move along prefe…”
BackgroundSelf-citationContinuous changes in structure mapped by manifold embedding of single-particle data in cryo-EM
Frank, J., & Ourmazd, A. (2016) · Methods · doi:10.1016/j.ymeth.2016.02.007 · Cited by 180
Spence, J. C. H., & Doak, R. B. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.198102 · Cited by 180 · cited 2×
“Nonspherical objects align theirmajor axes parallel to the flow of amicrojet (134), similar to the one-dimensional alignment of polarizable molecules using optical laser fields (45, 135, 136).”
BackgroundMethodDiffraction imaging of single particles and biomolecules
Huldt, G., Szőke, A., & Hajdu, J. (2003) · Journal of Structural Biology · doi:10.1016/j.jsb.2003.09.025 · Cited by 177 · cited 1×
“In the absence of any information about the orientation of particles, there needs to be enough information encoded in each diffraction pattern to determine that orientation with respect to all others, equivalent to determiningwhether two noisy patterns represent the same view of the object or two different views (111).”
BackgroundXFELs for structure and dynamics in biology
Spence, J. C. H. (2017) · IUCrJ · doi:10.1107/s2052252517005760 · Cited by 177 · cited 1×
“Since the relative energies of two conformations depend on the exponent of the ratio of their populations, Spence has argued that high-throughput single-particle FEL experiments may acquire many millions of measurements, enough to map energy differences exceeding that of the energy available from ATP per molecule (149…”
BackgroundFemtosecond response of polyatomic molecules to ultra-intense hard X-rays
Rudenko, A., Inhester, L., Hanasaki, K., Li, X., Robatjazi, S. J., Erk, B., Boll, R., Toyota, K., Hao, Y., Vendrell, O., et al. (2017) · Nature · doi:10.1038/nature22373 · Cited by 175 · cited 2×
“Such counterintuitive effects may even be amplified by the continuous neutralization of heavy atoms that draw electrons from surrounding atoms (28) to recharge their scattering strength.”
BackgroundTime-Resolved Macromolecular Crystallography
Moffat, K. (1989) · Annual Review of Biophysics and Biophysical Chemistry · doi:10.1146/annurev.bb.18.060189.001521 · Cited by 173
The Coherent X-ray Imaging instrument at the Linac Coherent Light Source
Liang, M., Williams, G. J., Messerschmidt, M., Seibert, M. M., Montanez, P. A., Hayes, M., Milathianaki, D., Aquila, A., Hunter, M. S., Koglin, J. E., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s160057751500449x · Cited by 171 · cited 1×
“However, it was not until this approach was demonstrated at the higher photon energies of approximately 8 keV available at the Coherent X-ray Imaging (CXI) beamline at LCLS in 2010 (57) that the hesitation voiced at the 1999 DESY meeting could finally be assuaged.”
BackgroundMicroholography of Living Organisms
Solem, J. C., & Baldwin, G. C. (1982) · Science · doi:10.1126/science.218.4569.229 · Cited by 164
Generation and characterization of ultrathin free-flowing liquid sheets
Koralek, J. D., Kim, J. B., Brůža, P., Curry, C. B., Chen, Z., Bechtel, H. A., Cordones, A. A., Sperling, P., Toleikis, S., Kern, J. F., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03696-w · Cited by 163
Generation of 1020 W cm−2 hard X-ray laser pulses with two-stage reflective focusing system
Mimura, H., Yumoto, H., Matsuyama, S., Koyama, T., Tono, K., Inubushi, Y., Togashi, T., Sato, T., Kim, J., Fukui, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms4539 · Cited by 156 · cited 1×
“At SACLA, pulse fluences exceeding 5 × 1012 photons μm−2 were achieved by focusing 42 μJ pulses to a spot of 55 nm × 30 nm with a duration of 7 fs (118).”
MethodMiao, J., Hodgson, K. O., & Sayre, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.111083998 · Cited by 154 · cited 1×
“(125) give simulations for 4 × 103 scattered photons per atom.”
BackgroundStructure of Hæmoglobin : An X-ray Examination of Reduced Horse Hæmoglobin
Perutz, M. F., Bolton, W., DIAMOND, R., Muirhead, H., & WATSON, H. C. (1964) · Nature · doi:10.1038/203687a0 · Cited by 152
Crystallographic data processing for free-electron laser sources
White, T. A., Barty, A., Stellato, F., Holton, J. M., Kirian, R. A., Zatsepin, N. A., & Chapman, H. N. (2013) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444913013620 · Cited by 147
Self-citationMacromolecular diffractive imaging using imperfect crystals
Ayyer, K., Yefanov, O. M., Oberthüer, D., Roy-Chowdhury, S., Galli, L., Mariani, V., Basu, S., Coe, J. D., Conrad, C. E., Fromme, R., et al. (2016) · Nature · doi:10.1038/nature16949 · Cited by 147
Self-citationDevelopments in X-ray Crystallographic Structure Determination of Biological Macromolecules
Garman, E. F. (2014) · Science · doi:10.1126/science.1247829 · Cited by 147
Wavelength choice for soft x-ray laser holography of biological samples
London, R. A., Rosen, M. D., & Trebes, J. E. (1989) · Applied Optics · doi:10.1364/ao.28.003397 · Cited by 147 · cited 1×
“By the time the construction of X-ray FELs was being considered in the 1990s, these considerations suggested that the femtosecond-duration pulses of FELs could allow atomic resolution, following from a simple dependency of imaging resolution on exposure time (15).”
BackgroundDouble-flow focused liquid injector for efficient serial femtosecond crystallography
Oberthüer, D., Knoška, J., Wiedorn, M. O., Beyerlein, K. R., Bushnell, D. A., Kovaleva, E. G., Heymann, M., Gumprecht, L., Kirian, R. A., Barty, A., et al. (2017) · Scientific Reports · doi:10.1038/srep44628 · Cited by 145 · cited 1×
“A potential method would pulse the sample into the continuously flowing jet of the double-flow-focused nozzle (73).”
MethodSelf-citationGoniometer-based femtosecond crystallography with X-ray free electron lasers
Cohen, A. E., Soltis, S. M., González, A., Aguila, L., Alonso-Mori, R., Barnes, C. O., Baxter, E. L., Brehmer, W., Brewster, A. S., Brunger, A. T., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1418733111 · Cited by 144
Roedig, P., Vartiainen, I., Duman, R., Panneerselvam, S., Stuebe, N., Lorbeer, O., Warmer, M., Sutton, G. C., Stuart, D. I., Weckert, E., et al. (2015) · Scientific Reports · doi:10.1038/srep10451 · Cited by 141 · cited 1×
“The ultimate sample efficiency may be achieved by applying crystals to a support membrane that is scanned through the beam (76, 77).”
BackgroundCryo‐EM—the first thirty years
Dubochet, J. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2011.03569.x · Cited by 141
Mix-and-diffuse serial synchrotron crystallography
Beyerlein, K. R., Dierksmeyer, D., Mariani, V., Kuhn, M., Sarrou, I., Ottaviano, A., Awel, S., Knoška, J., Fuglerud, S. S., Jönsson, H. O., et al. (2017) · IUCrJ · doi:10.1107/s2052252517013124 · Cited by 139 · cited 1×
“The dose was reduced even further for room-temperature measurements (96) at exposure times of 3 ms, creating the opportunity to use the mix-and-inject style of measurement of structural kinetics (97).”
BackgroundSelf-citationThe CSPAD megapixel x-ray camera at LCLS
Hart, P. A., Boutet, S., Carini, G. A., Dubrovin, M., Duda, B. J., Fritz, D., Haller, G. M., Herbst, R. T., Herrmann, S. C., Kenney, C. J., et al. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.930924 · Cited by 138 · cited 1×
“Experiences with different detector systems [which necessarily all employ cutting-edge technologies (44, 84, 123, 124)] suggest that the noise and gain characteristics of these systems impact data quality and that significant improvements can be expected.”
BackgroundFocusing capillary jets close to the continuum limit
Gañán‐Calvo, A. M., González‐Prieto, R., Chueca, P. R., Herrada, M. A., & Flores, M. V. (2007) · Nature Physics · doi:10.1038/nphys710 · Cited by 135 · cited 1×
“By the time of the LCLS opening, the ASU team had adopted a design of a coaxial sheath of gas that focused the liquid into a jet much thinner than the nozzle opening (47, 48) to reduce the background scattering.”
MethodIndications of radiation damage in ferredoxin microcrystals using high-intensity X-FEL beams
Nass, K., Foucar, L., Barends, T. R. M., Hartmann, E., Botha, S., Shoeman, R. L., Doak, R. B., Alonso-Mori, R., Aquila, A., Bajt, S., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515002349 · Cited by 131 · cited 2×
“The second sample tried in the same week of LCLS beamtime, lysozyme nanocrystals produced by Ilme Schlichting, showed a more complicated response (51), and measurements made at shorter wavelengths showed that specific atoms, such as those surrounding a heavy atom (which is thus strongly ionizing), can move along prefe…”
BackgroundSelf-citationCorrelations in Scattered X-Ray Laser Pulses Reveal Nanoscale Structural Features of Viruses
Kurta, R. P., Donatelli, J. J., Yoon, C. H., Berntsen, P., Bielecki, J., Daurer, B. J., DeMirci, H., Fromme, P., Hantke, M. F., Maia, F. R. N. C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.158102 · Cited by 129
Fixed target matrix for femtosecond time-resolved and in situ serial micro-crystallography
Mueller, C., Marx, A., Epp, S. W., Zhong, Y., Kuo, A., Balo, A. R., Soman, J., Schotte, F., Lemke, H. T., Owen, R. L., et al. (2015) · Structural Dynamics · doi:10.1063/1.4928706 · Cited by 128 · cited 1×
“The ultimate sample efficiency may be achieved by applying crystals to a support membrane that is scanned through the beam (76, 77).”
BackgroundPink-beam serial crystallography
Meents, A., Wiedorn, M. O., Šrajer, V., Henning, R. W., Sarrou, I., Bergtholdt, J., Barthelmeß, M., Reinke, P. Y. A., Dierksmeyer, D., Tolstikova, A., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01417-3 · Cited by 128 · cited 1×
“Combined with the higher flux, this pink-beam serial crystallography allows exposures as low as 100 ps of single pulses from crystals approximately 10 μm wide (101).”
BackgroundSelf-citationUervirojnangkoorn, M., Zeldin, O. B., Lyubimov, A. Y., Hattne, J., Brewster, A. S., Sauter, N. K., Brünger, A. T., & Weis, W. I. (2015) · eLife · doi:10.7554/elife.05421 · Cited by 125 · cited 1×
“As such, as few as 100 patterns gave the structures of myoglobin (120) using molecular refinement, compared with approximately 60,000 indexed patterns used for the first demonstration of a de novo protein crystal structure determination by single-wavelength anomalous diffraction (SAD) of lysozyme crystals soaked with…”
BackgroundDe novo phasing with X-ray laser reveals mosquito larvicide BinAB structure
Colletier, J., Sawaya, M. R., Gingery, M., Rodríguez, J. A., Cascio, D., Brewster, A. S., Michels-Clark, T., Hice, R. H., Coquelle, N., Boutet, S., et al. (2016) · Nature · doi:10.1038/nature19825 · Cited by 121 · cited 1×
“Some of the first applications of serial crystallography obtained structures from small crystals, such as those of cathepsin B (65) grown in living cells, natural mosquito larvacide crystals found in spores (66), and another pesticide called granulovirus that forms a crystalline shell around the viral body (33).”
BackgroundMegahertz data collection from protein microcrystals at an X-ray free-electron laser
Grünbein, M. L., Bielecki, J., Gorel, A., Stricker, M., Bean, R., Cammarata, M., Dörner, K., Fröhlich, L., Hartmann, E., Hauf, S., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05953-4 · Cited by 119
Loh, N. D., Bogan, M. J., Elser, V., Barty, A., Boutet, S., Bajt, S., Hajdu, J., Ekeberg, T., Maia, F. R. N. C., Schulz, J., et al. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.225501 · Cited by 119 · cited 15×
“Later renamed FLASH, this facility could generate thousands of high-intensity femtosecond-duration soft X-ray pulses per second rather than one Nova pulse every few hours (32).”
BackgroundMethodInfluentialSelf-citationSierra, R. G., Gati, C., Laksmono, H., Dao, E. H., Gul, S., Fuller, F. D., Kern, J. F., Chatterjee, R., Ibrahim, M., Brewster, A. S., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3667 · Cited by 117 · cited 1×
“Such a coaxial jet formed by an electric field was used to obtain a room-temperature structure of a ribosomal subunit using only 360μL of sample solution (72), and a gas-focused coaxial jet flowing at 5 μL min−1 was used to obtain a room-temperature structure of RNA polymerase II from 10.”
MethodRedox-coupled proton transfer mechanism in nitrite reductase revealed by femtosecond crystallography
Fukuda, Y., Tse, K. M., Nakane, T., Nakatsu, T., Suzuki, M., Sugahara, M., Inoué, S., Masuda, T., Yumoto, F., Matsugaki, N., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1517770113 · Cited by 117 · cited 1×
“In other cases, structures of radiation-sensitive metalloproteins, such as photosystem II (67–69), photosynthetic reaction center (70), and copper-containing nitrite reductase (71), could be determined at room temperature and without confounding effects due to photoreduction of active centers.”
BackgroundNew Python-based methods for data processing
Sauter, N. K., Hattne, J., Grosse-Kunstleve, R. W., & Echols, N. (2013) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444913000863 · Cited by 114 · cited 1×
“CrystFEL is widely used and actively being developed today (62) and has been joined by other software projects (63, 64).”
MethodRoedig, P., Duman, R., Sánchez-Weatherby, J., Vartiainen, I., Burkhardt, A., Warmer, M., Dávid, C., Wagner, A., & Meents, A. (2016) · Journal of Applied Crystallography · doi:10.1107/s1600576716006348 · Cited by 110
Thibault, P., & Elser, V. (2010) · Annual Review of Condensed Matter Physics · doi:10.1146/annurev-conmatphys-070909-104034 · Cited by 102
Structure of a photosynthetic reaction centre determined by serial femtosecond crystallography
Johansson, L. C., Arnlund, D., Katona, G., White, T. A., Barty, A., DePonte, D. P., Shoeman, R. L., Wickstrand, C., Sharma, A. S., Williams, G. J., et al. (2013) · Nature Communications · doi:10.1038/ncomms3911 · Cited by 97 · cited 1×
“In other cases, structures of radiation-sensitive metalloproteins, such as photosystem II (67–69), photosynthetic reaction center (70), and copper-containing nitrite reductase (71), could be determined at room temperature and without confounding effects due to photoreduction of active centers.”
BackgroundSelf-citationImaging biological specimens with high-intensity soft x rays
Solem, J. C. (1986) · Journal of the Optical Society of America B · doi:10.1364/josab.3.001551 · Cited by 92
Gati, C., Oberthüer, D., Yefanov, O. M., Bunker, R. D., Stellato, F., Chiu, E., Yeh, S., Aquila, A., Basu, S., Bean, R., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1609243114 · Cited by 89 · cited 3×
“An illustrative example that allows quantitative examination is an experiment carried out on invisibly small crystals of a protein called polyhedrin that encapsulate granuloviruses (33).”
BackgroundSelf-citationDouble-focusing mixing jet for XFEL study of chemical kinetics
Wang, D., Weierstall, U., Pollack, L., & Spence, J. C. H. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s160057751401858x · Cited by 84 · cited 1×
“This also meant that each crystal was single use, providing a single snapshot diffraction pattern and the potential for time-resolved measurements of samples undergoing irreversible reactions, whether initiated by a light pulse or by bringing reactants into contact [with two streams joining in a liquid jet, for exampl…”
BackgroundNass, K., Meinhart, A., Barends, T. R. M., Foucar, L., Gorel, A., Aquila, A., Botha, S., Doak, R. B., Koglin, J. E., Liang, M., et al. (2016) · IUCrJ · doi:10.1107/s2052252516002980 · Cited by 84 · cited 1×
“Over twice that many were required for the even more challenging task of sulfur-SAD phasing of lysozyme (107) and thaumatin (122).”
BackgroundMunke, A., Andreasson, J., Aquila, A., Awel, S., Ayyer, K., Barty, A., Bean, R., Berntsen, P., Bielecki, J., Boutet, S., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.64 · Cited by 83
Self-citationExperimental strategies for imaging bioparticles with femtosecond hard X-ray pulses
Daurer, B. J., Okamoto, K., Bielecki, J., Maia, F. R. N. C., Mühlig, K., Seibert, M. M., Hantke, M. F., Nettelblad, C., Benner, W. H., Svenda, M., et al. (2017) · IUCrJ · doi:10.1107/s2052252517003591 · Cited by 83 · cited 1×
“(110) provide a detailed account of signal and noise levels that have been achieved in diffraction measurements of 40 nm diameter Omono River virus particles at the LCLS, finding signals of several thousand photons per pattern to a resolution of approximately 5 nm and a background as low as several hundred counts.”
BackgroundFemtosecond X-ray Fourier holography imaging of free-flying nanoparticles
Gorkhover, T., Ulmer, A., Ferguson, K., Bucher, M., Maia, F. R. N. C., Bielecki, J., Ekeberg, T., Hantke, M. F., Daurer, B. J., Nettelblad, C., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0110-y · Cited by 79
Self-citationFast and accurate data collection for macromolecular crystallography using the JUNGFRAU detector
Leonarski, F., Redford, S., Mozzanica, A., Lopez-Cuenca, C., Panepucci, E., Nass, K., Ozerov, D., Vera, L., Oliéric, V., Buntschu, D., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0143-7 · Cited by 74
Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source
Reddy, H. K. N., Yoon, C. H., Aquila, A., Awel, S., Ayyer, K., Barty, A., Berntsen, P., Bielecki, J., Bobkov, S., Bucher, M., et al. (2017) · Scientific Data · doi:10.1038/sdata.2017.79 · Cited by 69 · cited 1×
“Some data sets of single-particle diffraction from virus particles have been made available (117, 127).”
MethodSelf-citationAuger-electron cascades in diamond and amorphous carbon
Ziaja, B., van der Spoel, D., Szöke, A., & Hajdu, J. (2001) · Physical review. B, Condensed matter · doi:10.1103/physrevb.64.214104 · Cited by 68 · cited 1×
“A photoelectron from a light element is energetic enough to inelastically scatter from a neighboring atom, ejecting a valence electron from this atom, setting off a cascade of ionizations that take place over a distance of approximately 1 μm, and taking approximately 100 fs to complete (24, 25).”
BackgroundCryogenic Electron Microscopy and Single-Particle Analysis
Elmlund, D., & Elmlund, H. (2015) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060614-034226 · Cited by 68 · cited 1×
“A key insight was that many such noisy images could be combined (to form a three-dimensional image of the molecule) and noise averaged away (6).”
BackgroundSerial Femtosecond Crystallography of G Protein–Coupled Receptors
Stauch, B., & Cherezov, V. (2018) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-070317-033239 · Cited by 62 · cited 4×
“A recent review of serial femtosecond crystallography of GPCRs is given by Stauch and Cherezov (75).”
BackgroundInfluentialSolem, J. C., & Chapline, G. (1984) · Optical Engineering · doi:10.1117/12.7973410 · Cited by 62
Signal, noise, and resolution in correlated fluctuations from snapshot small-angle x-ray scattering
Kirian, R. A., Schmidt, K. E., Wang, X., Doak, R. B., & Spence, J. C. H. (2011) · Physical Review E · doi:10.1103/physreve.84.011921 · Cited by 62
Native sulfur/chlorine SAD phasing for serial femtosecond crystallography
Nakane, T., Song, C., Suzuki, M., Nango, E., Kobayashi, J., Masuda, T., Inoué, S., Mizohata, E., Nakatsu, T., Tanaka, T. U., et al. (2015) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s139900471501857x · Cited by 60
Diffraction and imaging from a beam of laser-aligned proteins: resolution limits
Spence, J. C. H., Schmidt, K. E., Wu, J., Hembree, G. G., Weierstall, U., Doak, B. C., & Fromme, P. (2005) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767305002710 · Cited by 58 · cited 2×
“This proposal was made possible by a parallel effort led by John Spence of Arizona State University (ASU) to accumulate electron or X-ray diffraction of single molecules in solution and aligned to the laboratory frame by the action of an intense polarized laser beam (45, 46).”
BackgroundMethodCurrent Status of Single Particle Imaging with X-ray Lasers
Sun, Z., Fan, J., Li, H., & Jiang, H. (2018) · Applied Sciences · doi:10.3390/app8010132 · Cited by 51 · cited 1×
“Steady development of the method has since been continued at LCLS and SACLA, greatly helped by the Single Particle Initiative—a community effort carried out under the auspices of the LCLS facility (54, 55)—as discussed further in the final section.”
MethodIncoherent Diffractive Imaging via Intensity Correlations of Hard X Rays
Classen, A., Ayyer, K., Chapman, H. N., Röhlsberger, R., & von Zanthier, J. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.053401 · Cited by 51 · cited 1×
“(22) for a proposal to extract structural information from fluorescence.”
BackgroundSelf-citationFemtosecond X-ray coherent diffraction of aligned amyloid fibrils on low background graphene
Seuring, C., Ayyer, K., Filippaki, E., Barthelmeß, M., Longchamp, J.-N., Ringler, P., Pardini, T., Wojtas, D. H., Coleman, M. A., Dörner, K., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04116-9 · Cited by 49
Self-citationThe New Macromolecular Femtosecond Crystallography (MFX) Instrument at LCLS
Boutet, S., Cohen, A. E., & Wakatsuki, S. (2016) · Synchrotron Radiation News · doi:10.1080/08940886.2016.1124681 · Cited by 44 · cited 1×
“The Macromolecular Femtosecond Crystallography (MFX) beamline, which realizes the benefits of FEL pulses for crystallography with larger crystals and has a range of options for sample delivery and data collection, was built at the LCLS in 2016 to meet growing demands for these and goniometer-based experiments (80, 81).”
MethodToward atomic resolution diffractive imaging of isolated molecules with X-ray free-electron lasers
Stern, S., Holmegaard, L., Filsinger, F., Rouzée, A., Rudenko, A., Johnsson, P., Martin, A. V., Barty, A., Bostedt, C., Bozek, J. D., et al. (2014) · Faraday Discussions · doi:10.1039/c4fd00028e · Cited by 39
Self-citation7 Å resolution in protein two-dimensional-crystal X-ray diffraction at Linac Coherent Light Source
Pedrini, B., Tsai, C., Capitani, G., Padeste, C., Hunter, M. S., Zatsepin, N. A., Barty, A., Benner, W. H., Boutet, S., Feld, G. K., et al. (2014) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2013.0500 · Cited by 38 · cited 1×
“Scattered photons per atom 10–3 10–6 10–9 10–12 10–15 1 (108) (109)”
Perspectives for imaging single protein molecules with the present design of the European XFEL
Ayyer, K., Geloni, G., Kocharyan, V., Saldin, E., Serkez, S., Yefanov, O. M., & Zagorodnov, I. A. (2015) · Structural Dynamics · doi:10.1063/1.4919301 · Cited by 38 · cited 2×
“When estimating signals for single molecules of lysozyme (18) and RNA polymerase II (114) at a dose of more than 100 GGy, almost 15 orders of magnitude larger than the X-ray tube experiment, one must consider background scattering from the beamline or the medium carrying the sample.”
BackgroundObservation of correlated X-ray scattering at atomic resolution
Mendez, D. A., Lane, T. J., Sung, J., Sellberg, J. A., Levard, C., Watkins, H. M., Cohen, A. E., Soltis, S. M., Sutton, S. C., Spudich, J. A., et al. (2014) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2013.0315 · Cited by 37
Donatelli, J. J., Sethian, J. A., & Zwart, P. H. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1708217114 · Cited by 37
Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser
Bajt, S., Chapman, H. N., Spiller, E. A., Alameda, J. B., Woods, B. W., Frank, M. A., Bogan, M. J., Barty, A., Boutet, S., Marchesini, S., et al. (2008) · Applied Optics · doi:10.1364/ao.47.001673 · Cited by 36 · cited 1×
“Damage to the instrumentation itself was avoided with a novel camera system based on a multilayer-coated mirror with a hole that allowed the intense beam to pass harmlessly through the experiment (39).”
BackgroundSelf-citationShintake, T. (2008) · Physical Review E · doi:10.1103/physreve.78.041906 · Cited by 35 · cited 1×
“Attaching a known and strongly scattering particle to the object (141) or placing one nearby (142, 143) can boost the interpretable signal in the diffraction pattern far above noise that would have overwhelmed diffraction from the weak object alone.”
BackgroundOptimizing aerodynamic lenses for single-particle imaging
Roth, N., Awel, S., Horke, D. A., & Küpper, J. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.06.010 · Cited by 35 · cited 1×
“Two promising methods are focused aerosol particle injectors, of the kind that have been used since the first FLASH experiments (41, 53, 128), and thin solid supports, such as graphene, that can be scanned through the beam (109, 129, 130).”
MethodOn the release ofcppxfelfor processing X-ray free-electron laser images
Ginn, H. M., Evans, G., Sauter, N. K., & Stuart, D. I. (2016) · Journal of Applied Crystallography · doi:10.1107/s1600576716006981 · Cited by 34 · cited 1×
“CrystFEL is widely used and actively being developed today (62) and has been joined by other software projects (63, 64).”
MethodBiostructural Science Inspired by Next-Generation X-Ray Sources
Gruner, S. M., & Lattman, E. E. (2015) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-060414-033813 · Cited by 30 · cited 1×
“Vacuum environments are used to avoid air scatter: 1 mm thickness of air or 20 mm helium creates as much diffuse scattering as a 1 μm liquid jet (131).”
MethodFLASH: new opportunities for (time-resolved) coherent imaging of nanostructures
Treusch, R., & Feldhaus, J. (2010) · New Journal of Physics · doi:10.1088/1367-2630/12/3/035015 · Cited by 27 · cited 1×
“2 nm at the K-shell absorption edge of carbon,FLASHproved to be an effective platform for developing themethodologies for single-particle diffractive imaging and exploring new ideas for imaging (42).”
MethodFemtosecond X-ray diffraction from an aerosolized beam of protein nanocrystals
Awel, S., Kirian, R. A., Wiedorn, M. O., Beyerlein, K. R., Roth, N., Horke, D. A., Oberthüer, D., Knoška, J., Mariani, V., Morgan, A. J., et al. (2018) · Journal of Applied Crystallography · doi:10.1107/s1600576717018131 · Cited by 26 · cited 1×
“Methodologies for single-particle experiments could therefore still provide substantial gains for crystallography (126).”
BackgroundSelf-citationReproducible radiation-damage processes in proteins irradiated by intense x-ray pulses
Hau‐Riege, S. P., & Bennion, B. J. (2015) · Physical Review E · doi:10.1103/physreve.91.022705 · Cited by 25 · cited 1×
“The second sample tried in the same week of LCLS beamtime, lysozyme nanocrystals produced by Ilme Schlichting, showed a more complicated response (51), and measurements made at shorter wavelengths showed that specific atoms, such as those surrounding a heavy atom (which is thus strongly ionizing), can move along prefe…”
BackgroundMatthews, D. L., & Rosen, M. D. (1988) · Scientific American · doi:10.1038/scientificamerican1288-86 · Cited by 22
Lan, T.-Y., Li, P.-N., & Lee, T.-K. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/3/033016 · Cited by 22
Studies of the Structure of Matter with Photons from an X-ray Free-Electron Laser
Doniach, S. (1996) · Journal of Synchrotron Radiation · doi:10.1107/s0909049596009739 · Cited by 21 · cited 3×
“—Non ryst lline objects produce oversampled diffraction patterns from which phases can be directly recovered in an iterative process [16] where two constraints are sequentially enforced.”
BackgroundMethodInfluentialSingle-shot diffraction data from the Mimivirus particle using an X-ray free-electron laser
Ekeberg, T., Svenda, M., Seibert, M. M., Abergel, C., Maia, F. R. N. C., Seltzer, V., DePonte, D. P., Aquila, A., Andreasson, J., Iwan, B., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.60 · Cited by 19 · cited 1×
“Examples of X-ray free-electron laser diffraction: (a) granulovirus crystals (33), (b) single mimi virus particles (34, 35), (c) crystalline fibers (36), and (d) translationally disordered photosystem II crystals (37).”
BackgroundSelf-citationBoutet, S., Bogan, M. J., Barty, A., Frank, M. A., Benner, W. H., Marchesini, S., Seibert, M. M., Hajdu, J., & Chapman, H. N. (2008) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.06.004 · Cited by 19 · cited 1×
“Attaching a known and strongly scattering particle to the object (141) or placing one nearby (142, 143) can boost the interpretable signal in the diffraction pattern far above noise that would have overwhelmed diffraction from the weak object alone.”
BackgroundSelf-citationAnalysis of XFEL serial diffraction data from individual crystalline fibrils
Wojtas, D. H., Ayyer, K., Liang, M., Mossou, E., Romoli, F., Seuring, C., Beyerlein, K. R., Bean, R., Morgan, A. J., Oberthüer, D., et al. (2017) · IUCrJ · doi:10.1107/s2052252517014324 · Cited by 18 · cited 2×
“Examples of X-ray free-electron laser diffraction: (a) granulovirus crystals (33), (b) single mimi virus particles (34, 35), (c) crystalline fibers (36), and (d) translationally disordered photosystem II crystals (37).”
BackgroundSelf-citationFlow‐aligned, single‐shot fiber diffraction using a femtosecond X‐ray free‐electron laser
Popp, D., Loh, N. D., Zorgati, H., Ghoshdastider, U., Liow, L. T., Ivanova, M. I., Larsson, M., DePonte, D. P., Bean, R., Beyerlein, K. R., et al. (2017) · Cytoskeleton · doi:10.1002/cm.21378 · Cited by 17 · cited 1×
“Nonspherical objects align theirmajor axes parallel to the flow of amicrojet (134), similar to the one-dimensional alignment of polarizable molecules using optical laser fields (45, 135, 136).”
BackgroundSelf-citation
Cited by
Proton uptake mechanism in bacteriorhodopsin captured by serial synchrotron crystallography
Weinert, T., Skopintsev, P., James, D., Dworkowski, F., Panepucci, E., Kekilli, D., Furrer, A., Brünle, S., Mous, S., Ozerov, D., et al. (2019) · Science · doi:10.1126/science.aaw8634 · Cited by 172
“X-ray free electron lasers (XFELs) and the emerging method of time-resolved serial femtosecond crystallography (TR-SFX) brought exciting new opportunities for structural biologists (Schlichting 2015; Chapman 2019).”
BackgroundProbing the modulation of enzyme kinetics by multi-temperature, time-resolved serial crystallography
Schulz, E. C., Prester, A., von Stetten, D., Gore, G., Hatton, C. E., Bartels, K., Leimkohl, J.-P., Schikora, H., Ginn, H. M., Tellkamp, F., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61631-2 · Cited by 15
“In spite of this challenge, the majority of time-resolved structural studies are carried out at ambient temperatures, regardless of the actual physiological or optimal temperature of the protein under study 28,29 .”
Metadata
- Authors
- Chapman, H. N.
- Venue
- Annual Review of Biochemistry
- Publisher
- Annual Reviews
- Published
- 2019-06-20
- Volume
- 88
- Issue
- 1
- Pages
- 35-58
- ISSN
- 0066-4154 (ISSN-L)
- 1545-4509
- OpenAlex
- W2908318836
- Cited by
- 174
- References
- 132
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.