Translation of Near-Infrared Fluorescence Imaging Technologies: Emerging Clinical Applications
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Technical developments in near-infrared fluorescence (NIRF) imaging and tomography have enabled recent translation into investigational human studies. Noninvasive imaging of the lymphatic vasculature for diagnosis and assessment of function has been uniquely accomplished with NIR using indocyanine green (ICG), a nonspecific dye that has comparatively poor fluorescent properties compared to emerging dyes. Adjunct use of NIRF-ICG for (a) intraoperative sentinel lymph node mapping for cancer staging, (b) video-angiography during surgery, and (c) discrimination of malignant from benign breast lesions detected by mammography and ultrasongraphy also evidences the clinical utility of NIRF. Future NIRF imaging agents that consist of bright fluorescent dyes conjugated to disease-targeting moieties promise molecular imaging and image-guided surgery. In this review, emerging NIRF imaging is described within the context of nuclear imaging technologies that remain the “gold standard” of molecular imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lymphangiogenesis: Molecular Mechanisms and Future Promise
Tammela, T., & Alitalo, K. (2010) · Cell · doi:10.1016/j.cell.2010.01.045 · Cited by 1,441
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Self-citationNear-infrared fluorescence: application to in vivo molecular imaging
Hilderbrand, S. A., & Weissleder, R. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.09.029 · Cited by 1,023
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677
Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2009.11.007 · Cited by 593
Maruyama, K., Asai, J., Ii, M., Thorne, T., Losordo, D. W., & D'Amore, P. A. (2007) · The American Journal of Pathology · doi:10.2353/ajpath.2007.060018 · Cited by 492
Section XXV Adsorption Chromatographs
(2009) · Biotechnology · doi:10.1201/9781420084498-32 · Cited by 452
Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341
Self-citation
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Prabhakar, U., Maeda, H., Jain, R. K., Sevick-Muraca, E. M., Zamboni, W., Farokhzad, O. C., Barry, S. T., Gabizon, A., Grodzinski, P., & Blakey, D. C. (2013) · Cancer Research · doi:10.1158/0008-5472.can-12-4561 · Cited by 1,485
Self-citationImage-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Recent Advances of Optical Imaging in the Second Near‐Infrared Window
Kenry, Duan, Y., & Liu, B. (2018) · Advanced Materials · doi:10.1002/adma.201802394 · Cited by 810
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721
“Noninvasive imaging of lymphatic vasculature using ICG has also been described for surgical mapping and intraoperative identification of sentinel nodes, imaging nodes following surgical excision, and evaluation and monitoring of lymphedema (1, 5, 60, 61).”
MethodMultifunctional Nanoparticles for Drug Delivery and Molecular Imaging
Bao, G., Mitragotri, S., & Tong, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152409 · Cited by 536
The acidic tumor microenvironment: a target for smart cancer nano-theranostics
Feng, L., Dong, Z., Tao, D., Zhang, Y., & Liu, Z. (2018) · National Science Review · doi:10.1093/nsr/nwx062 · Cited by 426
Indocyanine green-incorporating nanoparticles for cancer theranostics
Wang, H., Li, X., Tse, B. W.-C., Yang, H., Thorling, C. A., Liu, Y., Touraud, M., Chouane, J. B., Liu, X., Roberts, M. S., et al. (2018) · Theranostics · doi:10.7150/thno.22872 · Cited by 378
Chi, C., Du, Y., Ye, J., Kou, D., Qiu, J., Wang, J., Tian, J., & Chen, X. (2014) · Theranostics · doi:10.7150/thno.9899 · Cited by 358
Biological imaging without autofluorescence in the second near-infrared region
Diao, S., Hong, G., Antaris, A. L., Blackburn, J. L., Cheng, K., Cheng, Z., & Dai, H. (2015) · Nano Research · doi:10.1007/s12274-015-0808-9 · Cited by 343
Shi, C., Wu, J. B., & Pan, D. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.5.050901 · Cited by 286
Application of the Nano-Drug Delivery System in Treatment of Cardiovascular Diseases
Deng, Y., Zhang, X., Shen, H., He, Q., Wu, Z., Liao, W., & Yuan, M. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00489 · Cited by 259
Near-infrared fluorescent probes in cancer imaging and therapy: an emerging field
Yi, X., Wang, F., Qin, W., Yang, X., & Yuan, J. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s60206 · Cited by 233
“Abnormal lymphatic function may be closely related to malignancies and venous disease.(151) SLNs are the initial draining lymph nodes of tumors.”
BackgroundBiomedical nanomaterials for imaging-guided cancer therapy
Huang, Y., He, S., Cao, W., Cai, K., & Liang, X.-J. (2012) · Nanoscale · doi:10.1039/c2nr31715j · Cited by 233
Darne, C., Lu, Y., & Sevick-Muraca, E. M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/r1 · Cited by 199
“Although not the subject of this review, planar NIR fluorescence imaging has been recently translated into the clinic for non-invasive as well as intraoperative imaging (Marshall et al 2010, Schaafsma et al 2011, Polom et al 2011, Sevick-Muraca 2012).”
BackgroundSelf-citationLysosome triggered near-infrared fluorescence imaging of cellular trafficking processes in real time
Grossi, M., Morgunova, M., Cheung, S., Scholz, D., Conroy, E., Terrile, M., Panarella, A., Simpson, J. C., Gallagher, W. M., & O’Shea, D. F. (2016) · Nature Communications · doi:10.1038/ncomms10855 · Cited by 197
Intraoperative Near-Infrared Imaging Can Identify Pulmonary Nodules
Okusanya, O. T., Holt, D., Heitjan, D., Deshpande, C., Venegas, O., Jiang, J., Judy, R., DeJesus, E., Madajewski, B., Oh, K., et al. (2014) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2014.05.026 · Cited by 180
“NIR imaging depends on a scanning device and an intravenous contrast agent (21).”
BackgroundLei, Z., Li, X., Luo, X., He, H., Zheng, J., Qian, X., & Yang, Y. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201612301 · Cited by 177
A review of performance of near-infrared fluorescence imaging devices used in clinical studies
Zhu, B., & Sevick-Muraca, E. M. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20140547 · Cited by 175
Self-citationMagnetic forces enable controlled drug delivery by disrupting endothelial cell-cell junctions
Qiu, Y., Tong, S., Zhang, L., Sakurai, Y., Myers, D. R., Hong, L., Lam, W. A., & Bao, G. (2017) · Nature Communications · doi:10.1038/ncomms15594 · Cited by 173
“Vascular permeability was evaluated in vivo by monitoring the accumulation in mouse tail of circulating indocyanine green (ICG), a small near-infrared fluorophore used in clinical examinations of vessel leakage in ophthalmic angiography 39 .”
Liu, M., Zhang, Z., Yang, Y., & Chan, Y. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202011914 · Cited by 134
Systems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
“In conjunction with disease-specific fluorescent contrast agents, FMI improves the specificity of neurological disease detection at the molecular level [6].”
BackgroundYu, J.-F., Li, J., & Li, M. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00561 · Cited by 16
Metadata
- Authors
- Sevick-Muraca, E. M.
- Venue
- Annual Review of Medicine
- Publisher
- Annual Reviews
- Published
- 2012-02-18
- Volume
- 63
- Issue
- 1
- Pages
- 217-231
- ISSN
- 0066-4219 (ISSN-L)
- 1545-326X
- OpenAlex
- W2099199155
- Cited by
- 339
- References
- 38
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.