Biomolecule Analysis by Ion Mobility Spectrometry
Open accessThe DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Abstract
Although nonnative protein conformations, including intermediates along the folding pathway and kinetically trapped misfolded species that disfavor the native state, are rarely isolated in the solution phase, they are often stable in the gas phase, where macromolecular ions from electrospray ionization can exist in varying charge states. Differences in the structures of nonnative conformations in the gas phase are often large enough to allow different shapes and charge states to be separated because of differences in their mobilities through a gas. Moreover, gentle collisional activation can be used to induce structural transformations. These new structures often have different mobilities. Thus, there is the possibility of developing a multidimensional separation that takes advantage of structural differences of multiple stable states. This review discusses how nonnative states differ in the gas phase compared with solution and presents an overview of early attempts to utilize and manipulate structures in order to develop ion mobility spectrometry as a rapid and sensitive technique for separating complex mixtures of biomolecules prior to mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berman, H. M. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.1.235 · Cited by 40,196
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
NMR with Proteins and Nucleic Acids
Wüthrich, K. (1986) · Europhysics News · doi:10.1051/epn/19861701011 · Cited by 7,989
Principles that Govern the Folding of Protein Chains
Anfinsen, C. B. (1973) · Science · doi:10.1126/science.181.4096.223 · Cited by 7,096
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
NMR of Proteins and Nucleic Acids
(2006) · Nuclear Magnetic Resonance · doi:10.1039/9781847555236-00336 · Cited by 5,863
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Announcing the worldwide Protein Data Bank
Berman, H., Henrick, K., & Nakamura, H. (2003) · Nature Structural & Molecular Biology · doi:10.1038/nsb1203-980 · Cited by 3,093
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Are there pathways for protein folding?
Levinthal, C. (1968) · Journal de Chimie Physique · doi:10.1051/jcp/1968650044 · Cited by 1,517
The current state of two-dimensional electrophoresis with immobilized pH gradients
Görg, A., Obermaier, C., Boguth, G., Harder, A., Scheibe, B., Wildgruber, R., & Weiss, W. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1037::aid-elps1037>3.0.co;2-v · Cited by 1,515
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Kuwajima, K. (1989) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.340060202 · Cited by 1,439
Structure of Myoglobin: A Three-Dimensional Fourier Synthesis at 2 Å. Resolution
KENDREW, J. C., DICKERSON, R. E., STRANDBERG, B. E., HART, R. G., DAVIES, D. R., PHILLIPS, D. C., & SHORE, V. C. (1960) · Nature · doi:10.1038/185422a0 · Cited by 1,352
PERUTZ, M. F., ROSSMANN, M. G., CULLIS, A. F., MUIRHEAD, H., WILL, G., & NORTH, A. C. T. (1960) · Nature · doi:10.1038/185416a0 · Cited by 1,350
Semisotnov, G. V., Rodionova, N. A., Razgulyaev, O. I., Uversky, V. N., Gripas', A. F., & Gilmanshin, R. I. (1991) · Biopolymers · doi:10.1002/bip.360310111 · Cited by 1,269
Energetics of Protein Structure
(1995) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60548-3 · Cited by 1,065
Structural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
Mesleh, M. F., Hunter, J. M., Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961623v · Cited by 1,043
Protein Folding: A Perspective from Theory and Experiment
Dobson, C. M., Šali, A., & Karplus, M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980420)37:7<868::aid-anie868>3.0.co;2-h · Cited by 869
Conformation Changes of Proteins
Lumry, R., & Eyring, H. (1954) · The Journal of Physical Chemistry · doi:10.1021/j150512a005 · Cited by 864
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Roder, H., Elöve, G. A., & Englander, S. W. (1988) · Nature · doi:10.1038/335700a0 · Cited by 813
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Theory of plasma chromatography/gaseous electrophoresis. Review
Revercomb, H. E., & Mason, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60357a043 · Cited by 755
Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Ion Mobility Measurements and their Applications to Clusters and Biomolecules
Clemmer, D. E., & Jarrold, M. F. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199706)32:6<577::aid-jms530>3.0.co;2-4 · Cited by 741
Self-citationHill, H. H., Siems, W. F., & St. Louis, R. H. (1990) · Analytical Chemistry · doi:10.1021/ac00222a001 · Cited by 737
‘Molten‐globule state’: a compact form of globular proteins with mobile side‐chains
Ohgushi, M., & Wada, A. (1983) · FEBS Letters · doi:10.1016/0014-5793(83)80010-6 · Cited by 729
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
An Introduction to Quadrupole Ion Trap Mass Spectrometry
March, R. E. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199704)32:4<351::aid-jms512>3.0.co;2-y · Cited by 708
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
Self-citationCooperativity in protein-folding kinetics.
Dill, K. A., Fiebig, K. M., & Chan, H. S. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.5.1942 · Cited by 480
Concepts and comparisons in multidimensional separation
Giddings, J. C. (1987) · Journal of High Resolution Chromatography · doi:10.1002/jhrc.1240100517 · Cited by 466
Accurate simulation of protein dynamics in solution.
Levitt, M., & Sharon, R. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.20.7557 · Cited by 447
Buryakov, I. A., Krylov, E. V., Nazarov, E. G., & Rasulev, U. K. (1993) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)87062-w · Cited by 444
SPECIAL FEATURE:TUTORIAL Slow Heating Methods in Tandem Mass Spectrometry
McLuckey, S. A., & Goeringer, D. E. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199705)32:5<461::aid-jms515>3.0.co;2-h · Cited by 425
Protein Structure in Vacuo: Gas-Phase Conformations of BPTI and Cytochrome c
Shelimov, K. B., Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9619059 · Cited by 414
Self-citationThe gas-phase basicities and proton affinities of amino acids and peptides
Harrison, A. G. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:4<201::aid-mas3>3.0.co;2-l · Cited by 403
Plasma Chromatography --A New Dimension for Gas Chromatography and Mass Spectrometry
Cohen, M. J., & Karasek, F. W. (1970) · Journal of Chromatographic Science · doi:10.1093/chromsci/8.6.330 · Cited by 365
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Coexisting stable conformations of gaseous protein ions.
Suckau, D., Shi, Y., Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.3.790 · Cited by 345
Three-Dimensional Ion Mobility/TOFMS Analysis of Electrosprayed Biomolecules
Hoaglund, C. S., Valentine, S. J., Sporleder, C. R., Reilly, J. P., & Clemmer, D. E. (1998) · Analytical Chemistry · doi:10.1021/ac980059c · Cited by 345
Self-citationEffect of the long-range potential on ion mobility measurements
Wyttenbach, T., von Helden, G., Batka, J. J., Carlat, D., & Bowers, M. T. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00236-x · Cited by 332
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Self-citationFOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETRY: THE TEENAGE YEARS
Marshall, A. G., & Grosshans, P. B. (1991) · Analytical Chemistry · doi:10.1021/ac00004a001 · Cited by 314
Protein stability parameters measured by hydrogen exchange
Bai, Y., Milne, J. S., Mayne, L., & Englander, S. W. (1994) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.340200103 · Cited by 307
High-resolution ion mobility measurements
Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147873 · Cited by 299
Self-citationGas-Phase Ion Chromatography: Transition Metal State Selection and Carbon Cluster Formation
Bowers, M. T., Kemper, P. R., von Helden, G., & van Koppen, P. A. M. (1993) · Science · doi:10.1126/science.260.5113.1446 · Cited by 289
Koeniger, S. L., Merenbloom, S. I., Valentine, S. J., Jarrold, M. F., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac051060w · Cited by 272
Self-citationMass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer
Purves, R. W., Guevremont, R., Day, S., Pipich, C. W., & Matyjaszczyk, M. S. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149255 · Cited by 265
Schaffer, S. A., Tang, K., Anderson, G. A., Prior, D. C., Udseth, H. R., & Smith, R. D. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19971030)11:16<1813::aid-rcm87>3.0.co;2-d · Cited by 262
Heat-induced conformational changes in proteins studied by electrospray ionization mass spectrometry
Mirza, U. A., Cohen, S. L., & Chait, B. T. (1993) · Analytical Chemistry · doi:10.1021/ac00049a003 · Cited by 256
Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00079-3 · Cited by 219
Self-citationAtmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer
Guevremont, R., & Purves, R. W. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149599 · Cited by 218
Electrospray Ionization Ion Mobility Spectrometry
Wittmer, D., Chen, Y. H., Luckenbill, B. K., & Hill, H. H. (1994) · Analytical Chemistry · doi:10.1021/ac00086a021 · Cited by 216
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04211-3 · Cited by 214
Shelimov, K. B., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja962914k · Cited by 205
Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex
Loo, J. A., Berhane, B., Kaddis, C. S., Wooding, K. M., Xie, Y., Kaufman, S. L., & Chernushevich, I. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.02.017 · Cited by 203
Multi-dimensional liquid phase based separations in proteomics
WANG, H., & HANASH, S. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00335-5 · Cited by 201
IMS−IMS and IMS−IMS−IMS/MS for Separating Peptide and Protein Fragment Ions
Merenbloom, S. I., Koeniger, S. L., Valentine, S. J., Plasencia, M. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac052208e · Cited by 200
Self-citationProton Transfer Reactivity of Large Multiply Charged Ions
Williams, E. R. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199608)31:8<831::aid-jms392>3.0.co;2-7 · Cited by 195
Mapping the human plasma proteome by SCX-LC-IMS-MS
Liu, X., Valentine, S. J., Plasencia, M. D., Trimpin, S., Naylor, S., & Clemmer, D. E. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.04.012 · Cited by 187
Self-citationLazaridis, T., Archontis, G., & Karplus, M. (1995) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60547-1 · Cited by 184
H/D Exchange Levels of Shape-Resolved Cytochrome c Conformers in the Gas Phase
Valentine, S. J., & Clemmer, D. E. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9626751 · Cited by 184
Self-citationElectronic-state chromatography: application to first-row transition-metal ions
Kemper, P. R., & Bowers, M. T. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100166a042 · Cited by 182
Dwivedi, P., Bendiak, B., Clowers, B. H., & Hill, H. H. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.04.007 · Cited by 174
Wuethrich, K. (1989) · Accounts of Chemical Research · doi:10.1021/ar00157a006 · Cited by 171
Toward Plasma Proteome Profiling with Ion Mobility-Mass Spectrometry
Valentine, S. J., Plasencia, M. D., Liu, X., Krishnan, M. R., Naylor, S., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Journal of Proteome Research · doi:10.1021/pr060232i · Cited by 171
Self-citationDirect tissue analysis of phospholipids in rat brain using MALDI-TOFMS and MALDI-ion mobility-TOFMS
Jackson, S. N., Wang, H.-Y. J., Woods, A. S., Ugarov, M., Egan, T., & Schultz, J. A. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.10.002 · Cited by 167
AVERAGE CROSS-SECTIONAL AREAS OF MOLECULES BY GASEOUS DIFFUSION METHODS
Mack, E. (1925) · Journal of the American Chemical Society · doi:10.1021/ja01687a007 · Cited by 166
Evidence for Many Resolvable Structures within Conformation Types of Electrosprayed Ubiquitin Ions
Koeniger, S. L., Merenbloom, S. I., & Clemmer, D. E. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp056165h · Cited by 165
Self-citationCoupling High-Pressure MALDI with Ion Mobility/Orthogonal Time-of-Flight Mass Spectrometry
Gillig, K. J., Ruotolo, B., Stone, E. G., Russell, D. H., Fuhrer, K., Gonin, M., & Schultz, A. J. (2000) · Analytical Chemistry · doi:10.1021/ac0005619 · Cited by 162
Li, J., Taraszka, J. A., Counterman, A. E., & Clemmer, D. E. (1999) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14135-0 · Cited by 160
Self-citationUsing Different Drift Gases To Change Separation Factors (α) in Ion Mobility Spectrometry
Asbury, G. R., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9908952 · Cited by 158
Conformations and folding of lysozyme ions in vacuo.
Gross, D. S., Schnier, P. D., Rodriguez‐Cruz, S. E., Fagerquist, C. K., & Williams, E. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.7.3143 · Cited by 156
A novel micromachined high-field asymmetric waveform-ion mobility spectrometer
Miller, R. A., Eiceman, G. A., Nazarov, E. G., & King, A. T. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00535-9 · Cited by 146
Valentine, S. J., Kulchania, M., Barnes, C. A. S., & Clemmer, D. E. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00511-5 · Cited by 143
Self-citationTwo-Dimensional Gas-Phase Separations Coupled to Mass Spectrometry for Analysis of Complex Mixtures
Tang, K., Li, F., Shvartsburg, A. A., Strittmatter, E. F., & Smith, R. D. (2005) · Analytical Chemistry · doi:10.1021/ac050871x · Cited by 141
Hadamard Transform Ion Mobility Spectrometry
Szumlas, A. W., Ray, S. J., & Hieftje, G. M. (2006) · Analytical Chemistry · doi:10.1021/ac051743b · Cited by 138
Karasek, F. W. (1974) · Analytical Chemistry · doi:10.1021/ac60344a724 · Cited by 133
Biomolecular folding in vacuo!!!(?)
Wolynes, P. G. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.7.2426 · Cited by 131
Evidence for unfolding and refolding of gas-phase cytochrome c ions in a Paul trap
Badman, E. R., Myung, S., & Clemmer, D. E. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.04.013 · Cited by 130
Self-citationMyung, S., Wiseman, J. M., Valentine, S. J., Takáts, Z., Cooks, R. G., & Clemmer, D. E. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp052663e · Cited by 126
Self-citationVenne, K., Bonneil, É., Eng, K., & Thibault, P. (2005) · Analytical Chemistry · doi:10.1021/ac048410j · Cited by 120
Loo, J. A., Hu, P., & Smith, R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80014-6 · Cited by 119
Hudgins, R. R., Woenckhaus, J., & Jarrold, M. F. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00182-1 · Cited by 118
Mobility Labeling for Parallel CID of Ion Mixtures
Hoaglund‐Hyzer, C. S., Li, J., & Clemmer, D. E. (2000) · Analytical Chemistry · doi:10.1021/ac0000170 · Cited by 117
Self-citationGas-phase separations of protease digests
Valentine, S. J., Counterman, A. E., Hoaglund‐Hyzer, C. S., Reilly, J. P., & Clemmer, D. E. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00101-9 · Cited by 116
Self-citationGross, D. S., Zhao, Y., & William, E. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00010-x · Cited by 116
Resolution and structural transitions of elongated states of ubiquitin
Koeniger, S. L., & Clemmer, D. E. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.09.025 · Cited by 113
Self-citationTransfer of Structural Elements from Compact to Extended States in Unsolvated Ubiquitin
Koeniger, S. L., Merenbloom, S. I., Sundarapandian, S., & Clemmer, D. E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062137g · Cited by 104
Self-citationVolumes of Individual Amino Acid Residues in Gas-Phase Peptide Ions
Counterman, A. E., & Clemmer, D. E. (1999) · Journal of the American Chemical Society · doi:10.1021/ja984344p · Cited by 96
Self-citationThermal Unfolding of Unsolvated Cytochrome c: Experiment and Molecular Dynamics Simulations
Mao, Y., Woenckhaus, J., Kolafa, J., Ratner, M. A., & Jarrold, M. F. (1999) · Journal of the American Chemical Society · doi:10.1021/ja980324b · Cited by 96
Investigation of the Gas-Phase Structure of Electrosprayed Proteins Using Ion-Molecule Reactions
Loo, R. R. O., & Smith, R. D. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85011-9 · Cited by 93
Steiner, W. E., Clowers, B. H., Führer, K., Gonin, M., Matz, L. M., Siems, W. F., Schultz, A. J., & Hill, H. H. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.495 · Cited by 87
A Split-Field Drift Tube for Separation and Efficient Fragmentation of Biomolecular Ions
Valentine, S. J., Koeniger, S. L., & Clemmer, D. E. (2003) · Analytical Chemistry · doi:10.1021/ac030111r · Cited by 75
Self-citationTaraszka, J. A., Kurulugama, R. T., Robinson, R. A. S., Valentine, S. J., Koeniger, S. L., Arnold, R. J., Miller, D. F., Kaufman, T. C., & Clemmer, D. E. (2005) · Journal of Proteome Research · doi:10.1021/pr050038g · Cited by 74
Self-citationMultiplexed Ion Mobility Spectrometry-Orthogonal Time-of-Flight Mass Spectrometry
Belov, M. E., Buschbach, M. A., Prior, D. C., Tang, K., & Smith, R. D. (2007) · Analytical Chemistry · doi:10.1021/ac0617316 · Cited by 73
Shvartsburg, A. A., Bryśkiewicz, T., Purves, R. W., Tang, K., Guevremont, R., & Smith, R. D. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp062573p · Cited by 71
Exploring Crown Ethers as Shift Reagents for Ion Mobility Spectrometry
Hilderbrand, A. E., Myung, S., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac060439v · Cited by 67
Self-citationFluorescence Probe of Trp-Cage Protein Conformation in Solution and in Gas Phase
Iavarone, A. T., Patriksson, A., van der Spoel, D., & Parks, J. H. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065092s · Cited by 67
Developing liquid chromatography ion mobility mass spectometry techniques
Valentine, S. J., Liu, X., Plasencia, M. D., Hilderbrand, A. E., Kurulugama, R. T., Koeniger, S. L., & Clemmer, D. E. (2005) · Expert Review of Proteomics · doi:10.1586/14789450.2.4.553 · Cited by 65
Self-citationHydration of Gas Phase Proteins: Folded +5 and Unfolded +7 Charge States of Cytochrome c
Woenckhaus, J., Mao, Y., & Jarrold, M. F. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963389e · Cited by 64
Do proteins denature during droplet evolution in electrospray ionization?
Mirza, U. A., & Chait, B. T. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04517-x · Cited by 62
Formation of peptide aggregates during ESI: Size, charge, composition, and contributions to noise
Counterman, A. E., Hilderbrand, A. E., Barnes, C. A. S., & Clemmer, D. E. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00283-5 · Cited by 61
Self-citationDetection of aliphatic N-nitrosamine compounds by plasma chromatography
Karasek, F. W., & Denney, D. W. (1974) · Analytical Chemistry · doi:10.1021/ac60345a031 · Cited by 43
Cited by
Supramolecular Coordination: Self-Assembly of Finite Two- and Three-Dimensional Ensembles
Chakrabarty, R., Mukherjee, P. S., & Stang, P. J. (2011) · Chemical Reviews · doi:10.1021/cr200077m · Cited by 2,926
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
A Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Metadata
- Authors
- Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2008-07-01
- Volume
- 1
- Issue
- 1
- Pages
- 293-327
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2170846952
- Cited by
- 492
- References
- 114
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.