Abstract
The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772 · cited 6×
“Regarding function, the modality offers methods such as the assessment of tissue perfusion and blood oxygen level–dependent (BOLD) (26, 27) and water tissue diffusion (28, 29).”
MethodInfluentialSchenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522 · cited 1×
“A comprehensive review of the MR compatibility of materials was presented by Schenck (88) along with many pertinent references.”
BackgroundKarni, A., Meyer, G., Rey-Hipolito, C., Jezzard, P., Adams, M. M., Turner, R., & Ungerleider, L. G. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.861 · Cited by 1,388 · cited 1×
“This approach has been used to investigate both how healthy subjects learn new complex tasks (47) and also to understand how people with initially disabling neurological disease, such as a stroke, improve functionally over time (48).”
BackgroundA functional MRI study of subjects recovered from hemiparetic stroke
Cramer, S. C., Nelles, G., Benson, R. R., Kaplan, J. D., Parker, R. A., Kwong, K. K., Kennedy, D. N., Finklestein, S. P., & Rosen, B. R. (1997) · Stroke · doi:10.1161/01.str.28.12.2518 · Cited by 1,019
Functional Neuroimaging Studies of Motor Recovery After Stroke in Adults: A Review
Calautti, C., & Baron, J.-C. (2003) · Stroke · doi:10.1161/01.str.0000071761.36075.a6 · Cited by 751 · cited 1×
“In recent years, the use of fMRI to explore brain plasticity following neurological injury has continued to rise (56).”
BackgroundNeural correlates of reach errors
Diedrichsen, J., Hashambhoy, Y., Rane, T., & Shadmehr, R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1874-05.2005 · Cited by 622
Luft, A. R., McCombe-Waller, S., Whitall, J., Forrester, L. W., Macko, R., Sorkin, J. D., Schulz, J. B., Goldberg, A. P., & Hanley, D. F. (2004) · JAMA · doi:10.1001/jama.292.15.1853 · Cited by 578 · cited 1×
“activation tasks commonly utilized during fMRI include making a fist (57), finger tapping (58), wrist extension (59), wrist passive flexion–extension (60), arm flexion– extension (61), finger flexion–extension (49), sequential finger tapping with opposition (57), and tracking a sine wave with the finger (62, 63).”
MR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Analysis of fMRI and finger tracking training in subjects with chronic stroke
Carey, J. R., Kimberley, T. J., Lewis, S. M., Auerbach, E. J., Dorsey, L., Rundquist, P., & Ugurbil, K. (2002) · Brain · doi:10.1093/brain/awf091 · Cited by 562 · cited 1×
“activation tasks commonly utilized during fMRI include making a fist (57), finger tapping (58), wrist extension (59), wrist passive flexion–extension (60), arm flexion– extension (61), finger flexion–extension (49), sequential finger tapping with opposition (57), and tracking a sine wave with the finger (62, 63).”
Correlation between motor improvements and altered fMRI activity after rehabilitative therapy
Johansen‐Berg, H., Dawes, H., Guy, C., Smith, S. M., Wade, D. T., & Matthews, P. M. (2002) · Brain · doi:10.1093/brain/awf282 · Cited by 558 · cited 2×
“The clinical relevance of fMRI also has been strengthened by recent experiments that have explored the neurobiological basis of specific rehabilitation strategies associated with the recovery of function (49).”
BackgroundReal‐time position monitoring of invasive devices using magnetic resonance
Dumoulin, C. L., Souza, S. P., & Darrow, R. D. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290322 · Cited by 445 · cited 1×
“Projection imaging can then be performed, which allows for fast spatial localization of the markers (105).”
BackgroundSafety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
Fluoxetine modulates motor performance and cerebral activation of patients recovering from stroke
Pariente, J., Loubinoux, I., Carel, C., Albucher, J., Leger, A., Manelfe, C., Rascol, O., & Chollet, F. (2001) · Annals of Neurology · doi:10.1002/ana.1257 · Cited by 367 · cited 1×
“activation tasks commonly utilized during fMRI include making a fist (57), finger tapping (58), wrist extension (59), wrist passive flexion–extension (60), arm flexion– extension (61), finger flexion–extension (49), sequential finger tapping with opposition (57), and tracking a sine wave with the finger (62, 63).”
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s · Cited by 343 · cited 1×
“Eddy-currents may also cause unwanted heating of the materials, resulting in burns (81, 87).”
BackgroundElectrical stimulation driving functional improvements and cortical changes in subjects with stroke
Kimberley, T. J., Lewis, S. M., Auerbach, E. J., Dorsey, L. L., Lojovich, J. M., & Carey, J. R. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1695-y · Cited by 318 · cited 1×
“activation tasks commonly utilized during fMRI include making a fist (57), finger tapping (58), wrist extension (59), wrist passive flexion–extension (60), arm flexion– extension (61), finger flexion–extension (49), sequential finger tapping with opposition (57), and tracking a sine wave with the finger (62, 63).”
Ankle dorsiflexion as an fMRI paradigm to assay motor control for walking during rehabilitation
Dobkin, B. H., Firestine, A., West, M., Saremi, K., & Woods, R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.008 · Cited by 312
Design of a Novel MRI Compatible Manipulator for Image Guided Prostate Interventions
Krieger, A., Susil, R. C., Ménard, C. M., Coleman, J., Fichtinger, G., Atalar, E., & Whitcomb, L. L. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840497 · Cited by 309 · cited 5×
“Manual actuation is the simplest choice and an example of such actuation is an interventional device designed to assist in prostate-related procedures (16, 23).”
BackgroundInfluentialDirect and fast detection of neuronal activation in the human brain with diffusion MRI
Le Bihan, D., Urayama, S.-I., Aso, T., Hanakawa, T., & Fukuyama, H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600644103 · Cited by 272 · cited 1×
“Regarding function, the modality offers methods such as the assessment of tissue perfusion and blood oxygen level–dependent (BOLD) (26, 27) and water tissue diffusion (28, 29).”
MethodUltrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252 · cited 1×
“0 Tesla (75) and recently as high as 9.”
BackgroundInvestigation of the factors responsible for burns during MRI
Dempsey, M. F., Condon, B. R., & Hadley, D. M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1088 · Cited by 232 · cited 1×
“Eddy-currents may also cause unwanted heating of the materials, resulting in burns (81, 87).”
BackgroundPineiro, R., Pendlebury, S., Johansen-Berg, H., & Matthews, P. M. (2001) · Stroke · doi:10.1161/01.str.32.5.1134 · Cited by 228 · cited 1×
“This approach has been used to investigate both how healthy subjects learn new complex tasks (47) and also to understand how people with initially disabling neurological disease, such as a stroke, improve functionally over time (48).”
BackgroundLearning arbitrary visuomotor associations: temporal dynamic of brain activity
Toni, I., Ramnani, N., Josephs, O., Ashburner, J., & Passingham, R. E. (2001) · NeuroImage · doi:10.1006/nimg.2001.0894 · Cited by 210 · cited 1×
“In studies of how a motor skill is learned, for example, fMRI follows the way the brain changes functionally over time, contributing to an understanding of which brain circuits are involved in developing the skills (46).”
BackgroundMRI/fMRI-compatible robotic system with force feedback for interaction with human motion
Gassert, R., Moser, R., Burdet, E., & Bleuler, H. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871897 · Cited by 188 · cited 1×
“(101) to investigate the brain mechanisms of human motor control.”
BackgroundMotor cortex activation is related to force of squeezing
Cramer, S. C., Weisskoff, R. M., Schaechter, J. D., Nelles, G., Foley, M., Finklestein, S. P., & Rosen, B. R. (2002) · Human Brain Mapping · doi:10.1002/hbm.10040 · Cited by 168 · cited 3×
“Several papers have reported the use of load cells within a MR environment (68, 95, 103).”
BackgroundFunctional magnetic resonance imaging of the human brain
Kim, S., & Uǧurbil, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02252-8 · Cited by 151 · cited 1×
“In the field of human motor control, data on brain activation have confirmed and extended the findings of previous electrophysiological studies in animals and patients who underwent neurological surgery (54, 55).”
ResultNeural pathways in tactile object recognition
Deibert, E., Kraut, M., Kremen, S., & Hart, J. (1999) · Neurology · doi:10.1212/wnl.52.7.1413 · Cited by 146 · cited 1×
“In most of the experiments conducted to date, manually controlled tactile perception tasks, such as tactile objection recognition, have been performed (108, 109).”
BackgroundAn MRI-Compatible Surgical Robot for Precise Radiological Interventions
Hempel, E., Fischer, H., Gumb, L., Höhn, T., Krause, H., Voges, U., Breitwieser, H., Gutmann, B., Durke, J., Bock, M., et al. (2003) · Computer Aided Surgery · doi:10.3109/10929080309146052 · Cited by 135 · cited 9×
“Two devices were also introduced as general purpose systems (13, 53).”
BackgroundInfluentialLindberg, P. G., Schmitz, C., Forssberg, H., Engardt, M., & Borg, J. (2004) · Journal of Rehabilitation Medicine · doi:10.1080/16501970410023434 · Cited by 127 · cited 1×
“activation tasks commonly utilized during fMRI include making a fist (57), finger tapping (58), wrist extension (59), wrist passive flexion–extension (60), arm flexion– extension (61), finger flexion–extension (49), sequential finger tapping with opposition (57), and tracking a sine wave with the finger (62, 63).”
Automatic Brachytherapy Seed Placement Under MRI Guidance
Patriciu, A., Petrisor, D., Müntener, M., Mazilu, D., Schär, M., & Stoianovici, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900816 · Cited by 114
Müntener, M., Patriciu, A., Petrisor, D., Mazilu, D., Bagga, H. S., Kavoussi, L. R., Cleary, K., & Stoianovici, D. S. (2006) · Urology · doi:10.1016/j.urology.2006.08.1089 · Cited by 112
Liu, J. Z., Dai, T. H., Elster, T., Sahgal, V., Brown, R. W., & Yue, G. H. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00252-1 · Cited by 100 · cited 2×
“Functional brain imaging-specific systems for fMRI studies in neuroscience and neuron rehabilitation include devices designed to measure forces exerted by subjects in their limb (68, 70, 103), tactile stimulators to produce somatonsensory cortex activation (72–74, 110–112), and computer-controlled force-generating sys…”
BackgroundGolaszewski, S. M., Siedentopf, C., Baldauf, E., Koppelstaetter, F., Eisner, W., Unterrainer, J. M., Guendisch, G. M., Mottaghy, F. M., & Felber, S. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1195 · Cited by 94 · cited 1×
“(110) to map the cortical areas that show activation during a vibration paradigm in fMRI studies.”
BackgroundPlastic Changes of Motor Network after Constraint-Induced Movement Therapy
Kim, Y., Park, J. W., Ko, M.-H., Jang, S. H., & Lee, P. K. W. (2004) · Yonsei Medical Journal · doi:10.3349/ymj.2004.45.2.241 · Cited by 90 · cited 1×
“activation tasks commonly utilized during fMRI include making a fist (57), finger tapping (58), wrist extension (59), wrist passive flexion–extension (60), arm flexion– extension (61), finger flexion–extension (49), sequential finger tapping with opposition (57), and tracking a sine wave with the finger (62, 63).”
System for MR Image–guided Prostate Interventions: Canine Study
Susil, R. C., Krieger, A., Derbyshire, J. A., Tanács, A., Whitcomb, L. L., Fichtinger, G., & Atalar, E. (2003) · Radiology · doi:10.1148/radiol.2283020911 · Cited by 84 · cited 5×
“Manual actuation is the simplest choice and an example of such actuation is an interventional device designed to assist in prostate-related procedures (16, 23).”
BackgroundInfluentialBrain activation during human finger extension and flexion movements
Yue, G. H., Liu, J. Z., Siemionow, V., Ranganathan, V. K., Ng, T. C., & Sahgal, V. (2000) · Brain Research · doi:10.1016/s0006-8993(99)02385-9 · Cited by 80 · cited 1×
“In the field of human motor control, data on brain activation have confirmed and extended the findings of previous electrophysiological studies in animals and patients who underwent neurological surgery (54, 55).”
ResultMR‐trackable intramyocardial injection catheter
Karmarkar, P. V., Kraitchman, D. L., Izbudak, I., Hofmann, L. V., Amado, L. C., Fritzges, D., Young, R. G., Pittenger, M. F., Bulte, J. W. M., & Atalar, E. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20086 · Cited by 77
An MR compatible robot technology
Moser, R., Gassert, R., Burdet, E., Sache, L., Woodtli, H. R., Erni, J., Maeder, W., & Bleuler, H. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241671 · Cited by 75 · cited 2×
“(90) investigated the use of a hydraulic master-slave system for MRI related applications focusing on the dynamics of the system.”
BackgroundA Data Glove with Tactile Feedback for fMRI of Virtual Reality Experiments
Ku, J. H., Mraz, R., Baker, N., Zakzanis, K. K., Lee, J. H., Kim, I. Y., Kim, S. I., & Graham, S. J. (2003) · CyberPsychology & Behavior · doi:10.1089/109493103769710523 · Cited by 67
Dissociated active and passive tactile shape recognition: a case study of pure tactile apraxia
Valenza, N., Ptak, R., Zimine, I., Badan, M., Lazeyras, F., & Schnider, A. (2001) · Brain · doi:10.1093/brain/124.11.2287 · Cited by 67 · cited 1×
“In most of the experiments conducted to date, manually controlled tactile perception tasks, such as tactile objection recognition, have been performed (108, 109).”
BackgroundA pneumatic vibrotactile stimulation device for fMRI
Briggs, R. W., Dy‐Liacco, I., Malcolm, M. P., Lee, H., Peck, K. K., Gopinath, K., Himes, N. C., Soltysik, D. A., Browne, P., & Tran‐Son‐Tay, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10732 · Cited by 64
Frontiers of brain mapping using MRI
Harel, N., Uǧurbil, K., Uludaǧ, K., & Yacoub, E. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20576 · Cited by 62 · cited 6×
“Regarding function, the modality offers methods such as the assessment of tissue perfusion and blood oxygen level–dependent (BOLD) (26, 27) and water tissue diffusion (28, 29).”
MethodInfluentialfMRI-compatible rehabilitation hand device
Khanicheh, A., Muto, A., Triantafyllou, C., Weinberg, B., Astrakas, L. G., Tzika, A. A., & Mavroidis, C. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-24 · Cited by 60
Self-citationA 2-DOF fMRI compatible haptic interface to investigate the neural control of arm movements
Gassert, R., Dovat, L., Lambercy, O., Ruffieux, Y., Chapuis, D., Ganesh, G., Burdet, E., & Bleuler, H. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642287 · Cited by 58 · cited 1×
“(66) presented a two-DOF haptic interface to investigate the neural control of multijoint arm movements.”
BackgroundBaumann, S. B., Noll, D. C., Kondziolka, D. S., Schneider, W., Nichols, T. E., Mintun, M. A., Lewine, J. D., Yonas, H., Orrison, W. W., & Sclabassi, R. J. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:4<242::aid-igs7>3.0.co;2-a · Cited by 56 · cited 7×
“A special feature of the USM is their high breaking torque, which allows a robotic system to maintain its current position and support its own weight when not actuated.”
BackgroundInfluentialA new pneumatic vibrator for functional magnetic resonance imaging of the human sensorimotor cortex
Golaszewski, S. M., Zschiegner, F., Siedentopf, C., Unterrainer, J. M., Sweeney, R. A., Eisner, W., Lechner-Steinleitner, S., Mottaghy, F. M., & Felber, S. R. (2002) · Neuroscience Letters · doi:10.1016/s0304-3940(02)00229-x · Cited by 52
A Platform for Combining Virtual Reality Experiments with Functional Magnetic Resonance Imaging
Mraz, R., Hong, J., Quintin, G., Staines, W. R., McIlroy, W. E., Zakzanis, K. K., & Graham, S. J. (2003) · CyberPsychology & Behavior · doi:10.1089/109493103322278736 · Cited by 51
Doyon, J. (1997) · International Review of Neurobiology · doi:10.1016/s0074-7742(08)60356-6 · Cited by 49
IVIM method measures diffusion and perfusion.
Bihan, D. L. (1990) · PubMed · Cited by 47
fMRI-Compatible Electromagnetic Haptic Interface
Riener, R., Villgrattner, T., Kleiser, R., Nef, T., & Kollias, S. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616123 · Cited by 44 · cited 2×
“These devices allow (a) the standardization of study condition, (b) the quantification of behavioral outcomes, and (c) the simulation of movements and setups used in specific clinical training routines (64).”
MethodFinger motion sensors for fMRI motor studies
Schaechter, J. D., Stokes, C., Connell, B. D., Perdue, K. L., & Bonmassar, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.029 · Cited by 40 · cited 2×
“the 10 fingers during fMRI was presented by Schaechter (71).”
Wacker, F. K., Hillenbrand, C. M., Duerk, J. L., & Lewin, J. S. (2005) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2005.04.004 · Cited by 40
Zappe, A. C., Maucher, T., Meier, K., & Scheiber, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20021 · Cited by 37
Design of a novel MRI compatible manipulator for image guided prostate intervention
Krieger, A., Susil, R. C., Fichtinger, G., Atalar, E., & Whitcomb, L. L. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307179 · Cited by 36
MR compatible manipulandum with ultrasonic motor for fMRI studies
Izawa, J., Shimizu, T., Gomi, H., Toyama, S., & Ito, K. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642291 · Cited by 31 · cited 1×
“(67) to investigate the neural correlates for motor control.”
BackgroundCheng, C. P., Schwandt, D. F., Topp, E. L., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10364 · Cited by 21 · cited 1×
“(116) for flow quantification in large arteries during lower limb exercise inside a 0.”
Background
Cited by
MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement
Fischer, G. S., Iordachita, I., Csoma, C., Tokuda, J., DiMaio, S. P., Tempany, C. M., Hata, N., & Fichtinger, G. (2008) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.924044 · Cited by 292
Medical telerobotic systems: current status and future trends
Avgousti, S., Christoforou, E. G., Panayides, A. S., Voskarides, S., Novales, C., Nouaille, L., Pattichis, C. S., & Vieyres, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0217-7 · Cited by 170
“The MR-compatible slave robot Fig.”
MethodInfluentialSelf-citation
Metadata
- Authors
- Tsekos, N. V., Khanicheh, A., Christoforou, E., & Mavroidis, C.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2007-08-15
- Volume
- 9
- Issue
- 1
- Pages
- 351-387
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2067309401
- Cited by
- 202
- References
- 55
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.