Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality and clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges is with intravenous contrast medium administration and scan timing. In this article, contrast medium pharmacokinetics and patient, contrast medium, and CT scanning factors associated with contrast enhancement and scan timing are presented and discussed. Published data from clinical studies of contrast medium and physiology are reviewed and interpreted. Computer simulation data are analyzed to provide an in-depth analysis of various factors associated with contrast enhancement and scan timing. On the basis of basic principles and analysis of the factors, clinical considerations and modifications to protocol design that are necessary to optimize contrast enhancement for common clinical CT applications are proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute Renal Failure After Coronary Intervention
McCullough, P. A., Wolyn, R., Rocher, L. L., Levin, R. N., & O’Neill, W. W. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)00150-2 · Cited by 1,671
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, A., Johnson, T. R. C., Chandarana, H., & Macari, M. (2009) · European Radiology · doi:10.1007/s00330-008-1122-7 · Cited by 479
Nakayama, Y., Awai, K., Funama, Y., Hatemura, M., Imuta, M., Nakaura, T., Ryu, D., Morishita, S., Sultana, S., Sato, N., et al. (2005) · Radiology · doi:10.1148/radiol.2373041655 · Cited by 422
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
Siegel, M. J., Schmidt, B., Bradley, D., Suess, C., & Hildebolt, C. (2004) · Radiology · doi:10.1148/radiol.2332032107 · Cited by 294
Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow.
Wintermark, M., Maeder, P. P., Verdun, F. R., Thiran, J., Valley, J., Schnyder, P. A., & Meuli, R. A. (2000) · PubMed · Cited by 269
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Yamashita, Y., Komohara, Y., Takahashi, M., Uchida, M., Hayabuchi, N., Shimizu, T., & Narabayashi, I. (2000) · Radiology · doi:10.1148/radiology.216.3.r00se26718 · Cited by 250
Bae, K. T., Seeck, B. A., Hildebolt, C. F., Tao, C., Zhu, F., Kanematsu, M., & Woodard, P. K. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2765 · Cited by 240
Self-citationBody surface area prediction in normal-weight and obese patients
Livingston, E. H., & Lee, S. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.281.3.e586 · Cited by 174
Awai, K., Takada, K., Onishi, H., & Hori, S. (2002) · Radiology · doi:10.1148/radiol.2243011188 · Cited by 164
Hunter, G. J. S., Hamberg, L. M., Ponzo, J. A., Huang‐Hellinger, F. R., Morris, P. P., Rabinov, J. D., Farkas, J., Lev, M. H., Schaefer, P. W., Ogilvy, C. S., et al. (1998) · PubMed · Cited by 162
Effect of Injection Rate of Contrast Medium on Pancreatic and Hepatic Helical CT
TUBLIN, M. E., Tessler, F. N., Cheng, S. L., Peters, T. L., & McGovern, P. C. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja2197 · Cited by 135
Saad, M. B., Rohnean, A., Sigal-Cinqualbre, A. B., Adler, G., & Paul, J. (2009) · Pediatric Radiology · doi:10.1007/s00247-009-1209-6 · Cited by 122
Kerl, J. M., Ravenel, J. G., Nguyen, S. A., Suranyi, P. S., Thilo, C., Costello, P., Bautz, W. A., & Schoepf, U. J. (2008) · Radiology · doi:10.1148/radiol.2472070856 · Cited by 119
Awai, K., Inoue, M., Yagyu, Y., Watanabe, M., Sano, T., Nin, S., Koike, R., Nishimura, Y., & Yamashita, Y. (2004) · Radiology · doi:10.1148/radiol.2333031617 · Cited by 112
Circulatory Physiology Cardiac Output and Its Regulation
Briggs, D. I. (1964) · Physical Therapy · doi:10.1093/ptj/44.1.69 · Cited by 112
A Proposed Blood Circulation Model for Reference Man
Leggett, R. W., & Williams, L. R. (1995) · Health Physics · doi:10.1097/00004032-199508000-00003 · Cited by 111
Delivery of diagnostic agents in computed tomography
Kŕause, W. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00105-7 · Cited by 102
Pancreatic CT Imaging: Effects of Different Injection Rates and Doses of Contrast Material
Kim, T., Murakami, T., Takahashi, S., Okada, A., Hori, M., Narumi, Y., & Nakamura, H. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jl06219 · Cited by 99
Han, J. K., Kim, A., Lee, K.-Y., Seo, J. B., Kim, T. K., Choi, B. I., Lhee, C. S., & Han, M. C. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200005000-00008 · Cited by 97
CT Angiography and CT Perfusion Imaging
Lev, M. H., & González, R. (2002) · Elsevier eBooks · doi:10.1016/b978-012693019-1/50019-8 · Cited by 91
de Monyé, C., Cademartiri, F., de Weert, T. T., Siepman, D. A. M., Dippel, D. W. J., & van der Lugt, A. (2005) · Radiology · doi:10.1148/radiol.2372040653 · Cited by 88
High-concentration contrast media in MDCT angiography: principles and rationale
Fleischmann, D. (2003) · European Radiology · doi:10.1007/s00330-003-0005-1 · Cited by 84
Schoellnast, H., Tillich, M., Deutschmann, H., Stessel, U., Deutschmann, M. J., Schaffler‐Schaden, D., Schoellnast, R., & Uggowitzer, M. M. (2004) · European Radiology · doi:10.1007/s00330-003-2085-3 · Cited by 76
Waaijer, A., van Leeuwen, M. S., van Osch, M. J. P., van der Worp, H. B., Moll, F. L., Lo, R. H., Mali, W. P. T. M., & Prokop, M. (2007) · Radiology · doi:10.1148/radiol.2451061493 · Cited by 71
Funabashi, N., 小林, 芳., Perlroth, M. G., & Rubin, G. D. (2003) · Radiology · doi:10.1148/radiol.2261011211 · Cited by 67
Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT
Sandstede, J. J. W., Tschammler, A., Beer, M., Vogelsang, C., Wittenberg, G., & Hahn, D. (2001) · European Radiology · doi:10.1007/s003300000816 · Cited by 62
Small, W. C., Nelson, R. C., Bernardino, M., et al. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.1.8010255 · Cited by 60
Use of high concentration contrast media (HCCM): principles and rationale—body CT
Brink, J. A. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00362-5 · Cited by 56
Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCT
Behrendt, F. F., Mahnken, A. H., Stanzel, S. F., Seidensticker, P. R., Jost, E., Günther, R. W., & Mühlenbruch, G. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3176 · Cited by 40
Marchianò, A. V., Spreafico, C., Lanocita, R., Frigerio, L. F., Tolla, G. D., Patelli, G., Garbagnati, F., Heiman, F., Taroni, P., & DAMASCELLI, B. (2004) · Abdominal Imaging · doi:10.1007/s00261-004-0233-0 · Cited by 31
Assessment of pancreatic CT enhancement using a high concentration of contrast material.
Shinagawa, M., Uchida, M., Ishibashi, M., Nishimura, H., & Hayabuchi, N. (2003) · PubMed · Cited by 19
Variability of clinical CT perfusion measurements in patients with carotid stenosis
Turk, A. S., Grayev, A. M., Rowley, H. A., Field, A. S., Turski, P. A., Pulfer, K. A., Mukherjee, R., & Haughton, V. M. (2007) · Neuroradiology · doi:10.1007/s00234-007-0276-3 · Cited by 19
Cited by
Safe Use of Contrast Media: What the Radiologist Needs to Know
Beckett, K. R., Moriarity, A. K., & Langer, J. M. (2015) · RadioGraphics · doi:10.1148/rg.2015150033 · Cited by 334
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Ibrahim, A., Primakov, S., Beuque, M., Woodruff, H. C., Halilaj, I., Wu, G., Refaee, T., Granzier, R., Widaatalla, Y., Hustinx, R., et al. (2021) · Methods · doi:10.1016/j.ymeth.2020.05.022 · Cited by 265
Yeh, B. M., FitzGerald, P. F., Edic, P. M., Lambert, J. W., Colborn, R. E., Marino, M. E., Evans, P. M., Roberts, J. C., Wang, Z. J., Wong, M. J., et al. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.001 · Cited by 219
Transport properties of pancreatic cancer describe gemcitabine delivery and response
Koay, E. J., Truty, M. J., Cristini, V., Thomas, R. M., Chen, R., Chatterjee, D., Kang, Y., Bhosale, P. R., Tamm, E. P., Crane, C. H., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci73455 · Cited by 184
Metadata
- Authors
- Bae, K. T.
- Venue
- Radiology
- Published
- 2010-07
- Volume
- 256
- Issue
- 1
- Pages
- 32-61
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2136860319
- Cited by
- 1,067
- References
- 34
- FWCI
- 26.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.