The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Open accessAbstract
Filtered back projection (FBP) has been the standard CT image reconstruction method for 4 decades. A simple, fast, and reliable technique, FBP has delivered high-quality images in several clinical applications. However, with faster and more advanced CT scanners, FBP has become increasingly obsolete. Higher image noise and more artifacts are especially noticeable in lower-dose CT imaging using FBP. This performance gap was partly addressed by model-based iterative reconstruction (MBIR). Yet, its "plastic" image appearance and long reconstruction times have limited widespread application. Hybrid iterative reconstruction partially addressed these limitations by blending FBP with MBIR and is currently the state-of-the-art reconstruction technique. In the past 5 years, deep learning reconstruction (DLR) techniques have become increasingly popular. DLR uses artificial intelligence to reconstruct high-quality images from lower-dose CT faster than MBIR. However, the performance of DLR algorithms relies on the quality of data used for model training. Higher-quality training data will become available with photon-counting CT scanners. At the same time, spectral data would greatly benefit from the computational abilities of DLR. This review presents an overview of the principles, technical approaches, and clinical applications of DLR, including metal artifact reduction algorithms. In addition, emerging applications and prospects are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Self-citationDeep Learning: A Primer for Radiologists
Chartrand, G., Cheng, P. M., Vorontsov, E., Drozdzal, M., Turcotte, S., Pal, C. J., Kadoury, S., & Tang, A. (2017) · RadioGraphics · doi:10.1148/rg.2017170077 · Cited by 1,115
Generative Adversarial Networks for Noise Reduction in Low-Dose CT
Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2708987 · Cited by 1,037
Preparing Medical Imaging Data for Machine Learning
Willemink, M. J., Koszek, W. A., Hardell, C., Wu, J., Fleischmann, D., Harvey, H., Folio, L. R., Summers, R. M., Rubin, D. L., & Lungren, M. P. (2020) · Radiology · doi:10.1148/radiol.2020192224 · Cited by 1,020
Self-citationA three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Self-citationA deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction
Kang, E., Min, J., & Ye, J. C. (2017) · Medical Physics · doi:10.1002/mp.12344 · Cited by 709
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Self-citationApplications, promises, and pitfalls of deep learning for fluorescence image reconstruction
Belthangady, C., & Royer, L. A. (2019) · Nature Methods · doi:10.1038/s41592-019-0458-z · Cited by 510
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Self-citationSingh, S., Kalra, M. K., Hsieh, J., Licato, P. E., Do, S., Pien, H. H., & Blake, M. A. (2010) · Radiology · doi:10.1148/radiol.10092212 · Cited by 435
Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT
Akagi, M., Nakamura, Y., Higaki, T., Narita, K., Honda, Y., Zhou, J., Yu, Z., Akino, N., & Awai, K. (2019) · European Radiology · doi:10.1007/s00330-019-06170-3 · Cited by 346
Current and Novel Techniques for Metal Artifact Reduction at CT: Practical Guide for Radiologists
Katsura, M., Sato, J., Akahane, M., Kunimatsu, A., & Abe, O. (2018) · RadioGraphics · doi:10.1148/rg.2018170102 · Cited by 343
Katsura, M., Matsuda, I., Akahane, M., Sato, J., Akai, H., Yasaka, K., Kunimatsu, A., & Ohtomo, K. (2012) · European Radiology · doi:10.1007/s00330-012-2452-z · Cited by 278
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Self-citationDigital radiography: The balance between image quality and required radiation dose
Uffmann, M., & Schaefer-Prokop, C. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.05.060 · Cited by 244
Iterative Low-Dose CT Reconstruction With Priors Trained by Artificial Neural Network
Wu, D., Kim, K., El Fakhri, G., & Li, Q. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2753138 · Cited by 244
Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics
Higaki, T., Nakamura, Y., Zhou, J., Yu, Z., Nemoto, T., Tatsugami, F., & Awai, K. (2020) · Academic Radiology · doi:10.1016/j.acra.2019.09.008 · Cited by 210
ADN: Artifact Disentanglement Network for Unsupervised Metal Artifact Reduction
Liao, H., Lin, W.-A., Zhou, S. K., & Luo, J. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2933425 · Cited by 206
Brady, S. L., Trout, A. T., Somasundaram, E., Anton, C. G., Li, Y., & Dillman, J. R. (2021) · Radiology · doi:10.1148/radiol.2020202317 · Cited by 189
Benz, D. C., Benetos, G., Rampidis, G., von Felten, E., Bakula, A., Sustar, A., Kudura, K., Messerli, M., Fuchs, T. A., Gebhard, C., et al. (2020) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.01.002 · Cited by 168
Deep Learning: An Update for Radiologists
Cheng, P. M., Montagnon, E., Yamashita, R., Pan, I., Cadrin-Chênevert, A., Perdigón Romero, F., Chartrand, G., Kadoury, S., & Tang, A. (2021) · RadioGraphics · doi:10.1148/rg.2021200210 · Cited by 166
TransCT: Dual-Path Transformer for Low Dose Computed Tomography
Zhang, Z., Yu, L., Liang, X., Zhao, W., & Xing, L. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87231-1_6 · Cited by 163
Radon Inversion via Deep Learning
He, J., Wang, Y., & Ma, J. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2964266 · Cited by 158
Metal artifact reduction on cervical CT images by deep residual learning
Huang, X., Wang, J., Tang, F., Zhong, T., & Zhang, Y. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0609-y · Cited by 147
Convolutional Sparse Coding for Compressed Sensing CT Reconstruction
Bao, P., Sun, H., Wang, Z., Zhang, Y., Xia, W., Yang, K., Chen, W., Chen, M., Xi, Y., Niu, S., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2906853 · Cited by 142
Kim, J. H., Yoon, H. J., Lee, E., Kim, I., Ki, Y., & Bak, S. H. (2020) · Korean Journal of Radiology · doi:10.3348/kjr.2020.0116 · Cited by 138
Nonlocality-Reinforced Convolutional Neural Networks for Image Denoising
Cruz, C., Foi, A., Katkovnik, V. Y., & Egiazarian, K. (2018) · IEEE Signal Processing Letters · doi:10.1109/lsp.2018.2850222 · Cited by 132
Racine, D., Becce, F., Viry, A., Monnin, P., Thomsen, B., Verdun, F. R., & Rotzinger, D. C. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.06.004 · Cited by 121
Reduced-Dose Deep Learning Reconstruction for Abdominal CT of Liver Metastases
Jensen, C. T., Gupta, S., Saleh, M., Liu, X., Wong, V. K., Salem, U. I., Qiao, W., Samei, E., & Wagner‐Bartak, N. A. (2022) · Radiology · doi:10.1148/radiol.211838 · Cited by 118
Wang, H., Li, Y., He, N., Ma, K., Meng, D., & Zheng, Y. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3127074 · Cited by 103
Unsupervised CT Metal Artifact Learning Using Attention-Guided β-CycleGAN
Lee, J., Gu, J., & Ye, J. C. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3101363 · Cited by 93
Benz, D. C., Ersözlü, S., Mojon, F. L. A., Messerli, M., Mitulla, A. K., Ciancone, D., Kenkel, D., Schaab, J. A., Gebhard, C., Pazhenkottil, A. P., et al. (2021) · European Radiology · doi:10.1007/s00330-021-08367-x · Cited by 90
Kim, I., Kang, H., Yoon, H. J., Chung, B. M., & Shin, N. (2020) · Neuroradiology · doi:10.1007/s00234-020-02574-x · Cited by 86
Nakamura, Y., Higaki, T., Tatsugami, F., Zhou, J., Yu, Z., Akino, N., Ito, Y., Iida, M., & Awai, K. (2019) · Radiology Artificial Intelligence · doi:10.1148/ryai.2019180011 · Cited by 82
Bernard, A., Comby, P., Lemogne, B., Haioun, K., Ricolfi, F., Chevallier, O., & Loffroy, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-626 · Cited by 82
Li, W., Diao, K., Wen, Y., Shuai, T., You, Y., Zhao, J., Liao, K., Lu, C., Yu, J., He, Y., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08424-5 · Cited by 75
Nam, J. G., Ahn, C., Choi, H., Hong, W., Park, J., Kim, J. H., & Goo, J. M. (2021) · European Radiology · doi:10.1007/s00330-020-07537-7 · Cited by 71
A dual-stream deep convolutional network for reducing metal streak artifacts in CT images
Gjesteby, L., Shan, H., Yang, Q., Xi, Y., Jin, Y., Giantsoudi, D., Paganetti, H., Man, B. D., & Wang, G. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab4e3e · Cited by 68
Single– versus Multi–Detector Row CT of the Brain: Quality Assessment
Jones, T. R., Kaplan, R. T., Lane, B., et al. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn47750 · Cited by 62
Nakamura, Y., Narita, K., Higaki, T., Akagi, M., Honda, Y., & Awai, K. (2021) · European Radiology · doi:10.1007/s00330-020-07566-2 · Cited by 61
Secure and robust machine learning for healthcare: A survey
Qayyum, A., Qadir, J., Bilal, M., & Al-Fuqaha, A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3013489 · Cited by 59
Social Asymmetry, Artificial Intelligence and the Medical Imaging Landscape
Currie, G. M., & ROHREN, E. M. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.11.011 · Cited by 59
van Stiphout, J. A., Driessen, J., Koetzier, L. R., Ruules, L. B., Willemink, M., Heemskerk, J., & van der Molen, A. J. (2021) · European Radiology · doi:10.1007/s00330-021-08438-z · Cited by 59
Self-citationSecure and Robust Machine Learning for Healthcare: A Survey
Qayyum, A., Qadir, J., Bilal, M., & Al-Fuqaha, A. (2020) · arXiv · doi:10.48550/arxiv.2001.08103 · Cited by 59
Franck, C., Zhang, G., Deak, P. D., & Zanca, F. (2021) · Physica Medica · doi:10.1016/j.ejmp.2020.12.005 · Cited by 58
Liang, K., Zhang, L., Yang, H., Yang, Y., Chen, Z., & Xing, Y. (2019) · Medical Physics · doi:10.1002/mp.13644 · Cited by 57
Hata, A., Yanagawa, M., Yoshida, Y., Miyata, T., Tsubamoto, M., Honda, O., & Tomiyama, N. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.19.22680 · Cited by 56
Park, S., Yoon, J. H., Joo, I., Yu, M. H., Kim, J. H., Park, J., Kim, S. W., Han, S., Ahn, C., Kim, J. H., et al. (2021) · European Radiology · doi:10.1007/s00330-021-08380-0 · Cited by 55
DAN-Net: Dual-domain adaptive-scaling non-local network for CT metal artifact reduction
Wang, T., Xia, W., Huang, Y., Sun, H., Liu, Y., Chen, H., Zhou, J., & Zhang, Y. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac1156 · Cited by 53
Lee, H., Huang, C., Yune, S., Tajmir, S., Kim, M., & Do, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-51779-5 · Cited by 46
Kubo, T., Ohno, Y., Takenaka, D., Nishino, M., Gautam, S., Sugimura, K., Kauczor, H., & Hatabu, H. (2016) · European Journal of Radiology Open · doi:10.1016/j.ejro.2016.03.002 · Cited by 44
Hata, A., Yanagawa, M., Yoshida, Y., Miyata, T., Kikuchi, N., Honda, O., & Tomiyama, N. (2020) · Clinical Radiology · doi:10.1016/j.crad.2020.10.011 · Cited by 44
Metal artifact reduction in 2D CT images with self-supervised cross-domain learning
Yu, L., Zhang, Z., Li, X., et al. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac195c · Cited by 38
Tamura, A., Mukaida, E., Ota, Y., Kamata, M., Abe, S., & Yoshioka, K. (2021) · British Journal of Radiology · doi:10.1259/bjr.20201357 · Cited by 37
A Cross-Domain Metal Trace Restoring Network for Reducing X-Ray CT Metal Artifacts
Peng, C., Li, B., Liang, P., Zheng, J., Zhang, Y., Qiu, B., & Chen, D. Z. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3005432 · Cited by 35
Man, Q. D., Haneda, E., Claus, B. E. H., Fitzgerald, P. B., Man, B. D., Qian, G., Shan, H., Min, J. K., Sabuncu, M. R., & Wang, G. (2019) · Medical Physics · doi:10.1002/mp.13640 · Cited by 31
Zeng, L.-M., Xu, X., Zeng, W., et al. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.109487 · Cited by 28
Njølstad, T. S., Schulz, A., Godt, J. C., et al. (2021) · Acta Radiologica Open · doi:10.1177/20584601211008391 · Cited by 22
Mikayama, R., Shirasaka, T., Kojima, T., Sakai, Y., Yabuuchi, H., Kondo, M., & Kato, T. (2021) · British Journal of Radiology · doi:10.1259/bjr.20210915 · Cited by 21
Hooper, S., Dunnmon, J., Lungren, M. P., Mastrodicasa, D., Rubin, D. L., Ré, C., Wang, A., & Patel, B. N. (2021) · Radiology Artificial Intelligence · doi:10.1148/ryai.2021200229 · Cited by 19
Self-citationShirasaka, T., Kojima, T., Funama, Y., et al. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13318 · Cited by 18
The potential for reduced radiation dose from deep learning-based CT image reconstruction
Lee, J. E., Choi, S., Hwang, J. A., Lim, S., Lee, M. H., Yi, B. H., & Cha, J. G. (2021) · Medicine · doi:10.1097/md.0000000000025814 · Cited by 17
Kim, Y., Oh, D. Y., Chang, W., Kang, E., Ye, J. C., Lee, K., Kim, H. Y., Kim, Y. H., Park, J. H., Lee, Y. J., et al. (2021) · European Radiology · doi:10.1007/s00330-021-07810-3 · Cited by 12
Yang, S., Bie, Y., Pang, G., Li, X., Zhao, K., Zhang, C., & Zhong, H. (2021) · Journal of X-Ray Science and Technology · doi:10.3233/xst-210953 · Cited by 9
Cited by
Mastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
Self-citationA survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
de Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
Gennari, A. G., Rossi, A., De Cecco, C. N., van Assen, M., Sartoretti, T., Giannopoulos, A. A., Schwyzer, M., Huellner, M. W., & Messerli, M. (2024) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-024-03080-4 · Cited by 16
Metadata
- Authors
- Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J.
- Venue
- Radiology
- Published
- 2023-03-01
- Volume
- 306
- Issue
- 3
- Pages
- e221257-e221257
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4318620303
- Cited by
- 427
- References
- 72
- FWCI
- 63.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.