The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
CT and Conventional and Diffusion-weighted MR Imaging in Acute Stroke: Study in 691 Patients at Presentation to the Emergency Department
Abstract
PURPOSE: To compare the diagnostic accuracy of computed tomography (CT) and magnetic resonance (MR) imaging in a consecutive series of patients at presentation to the emergency department with symptoms of acute stroke. MATERIALS AND METHODS: Clinical data and images obtained in 691 consecutive patients with suspected acute stroke were examined. Results of first and second head CT and brain diffusion-weighted (DW) and conventional MR imaging were compared with each other and with the final neurologic discharge diagnosis. RESULTS: Five hundred seventy-three patients underwent CT at presentation, with 42% sensitivity (95% CI: 37%, 46%) and 91% specificity (95% CI: 82%, 96%). A total of 173 patients underwent a second CT examination, with 77% sensitivity (95% CI: 70%, 84%) and 79% specificity (95% CI: 49%, 95%). Of 498 MR images, 411 were DW, with 94% sensitivity (95% CI: 1%, 96%) and 97% specificity (95% CI: 88%, 100%), and 87 were conventional, with 70% sensitivity (95% CI: 58%, 81%) and 94% specificity (95% CI: 70%, 100%). By using DW MR imaging in the early period (<6 hours after presentation to emergency department), a 97% sensitivity (95% CI: 92%, 100%) and a 100% specificity (95% CI: 69%, 100%) were achieved, compared with 58% (29%-84%) and 100% (16%-100%), respectively, with conventional MR imaging, and 40% (35%-45%) and 92% (84%-97%), respectively, with CT. Negative predictive value was higher with DW MR imaging (73%) than with conventional (42%) MR imaging or CT (24%). In studies conducted within 12 hours, DW MR imaging achieved substantially superior accuracy than did CT. After 12 hours, accuracy was equivalent. CONCLUSION: In the diagnosis of stroke in the early period (<12 hours after presentation), DW MR imaging is superior to conventional MR imaging and CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Diffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Self-citationAcute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging
Warach, S., Gaa, J., Siewert, B., Wielopolski, P., & Edelman, R. R. (1995) · Annals of Neurology · doi:10.1002/ana.410370214 · Cited by 1,004
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Sorensen, A. G., Buonanno, F. S., Gonzalez, R. G., Schwamm, L. H., Lev, M. H., Huang-Hellinger, F. R., Reese, T. G., Weisskoff, R. M., Davis, T. L., Suwanwela, N., et al. (1996) · Radiology · doi:10.1148/radiology.199.2.8668784 · Cited by 730
Self-citationAlbers, G. W., Bates, V. E., Clark, W. M., Bell, R., Verro, P., & Hamilton, S. A. (2000) · JAMA · doi:10.1001/jama.283.9.1145 · Cited by 700
Use of Tissue-Type Plasminogen Activator for Acute Ischemic Stroke: The Cleveland Area Experience
Katzan, I. L., Furlan, A. J., Lloyd, L. E., Frank, J. I., Harper, D. L., Hinchey, J. A., Hammel, J. P., Qu, A., & Sila, C. A. (2000) · JAMA · doi:10.1001/jama.283.9.1151 · Cited by 648
Determinants of anisotropic water diffusion in nerves
Beaulieu, C., & Allen, P. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310408 · Cited by 613
González, R. G., Schaefer, P. W., Buonanno, F. S., Schwamm, L. H., Budzik, R. F., Rordorf, G., Wang, B., Sorensen, A. G., & Koroshetz, W. J. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja02155 · Cited by 599
Self-citationDiffusion MRI in Patients With Transient Ischemic Attacks
Kidwell, C. S., Alger, J. R., Di Salle, F., Starkman, S., Villablanca, P., Bentson, J., & Saver, J. L. (1999) · Stroke · doi:10.1161/01.str.30.6.1174 · Cited by 590
Acute stroke: usefulness of early CT findings before thrombolytic therapy.
von Kummer, R., Allen, K. L., Holle, R., Bozzao, L., Bastianello, S., Manelfe, C., Bluhmki, E., Ringleb, P., Meier, D. H., & Hacke, W. (1997) · Radiology · doi:10.1148/radiology.205.2.9356611 · Cited by 587
Diffusion MR imaging: clinical applications.
Le Bihan, D., Turner, R., Douek, P., & Patronas, N. (1992) · American Journal of Roentgenology · doi:10.2214/ajr.159.3.1503032 · Cited by 489
Clinical experience with diffusion-weighted MR in patients with acute stroke.
Lövblad, K., Laubach, H., Baird, A. E., Curtin, F., Schlaug, G., Edelman, R. R., & Warach, S. J. (1998) · PubMed · Cited by 488
Diffusion-Weighted Magnetic Resonance Imaging in Acute Stroke
van Everdingen, K. J., van der Grond, J., Kappelle, L. J., Ramos, L. M. P., & Mali, W. P. T. M. (1998) · Stroke · doi:10.1161/01.str.29.9.1783 · Cited by 459
Water diffusion and acute stroke
van Gelderen, P., de Vleeschouwer, M. H. M., DesPres, D., Pekar, J., van Zijl, P. C. M., & Moonen, C. T. W. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310209 · Cited by 410
Treatment of Acute Ischemic Stroke
Brott, T., & Bogousslavsky, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200009073431007 · Cited by 398
Schwamm, L. H., Koroshetz, W. J., Sorensen, A. G., Wang, B., Copen, W. A., Budzik, R., Rordorf, G., Buonanno, F. S., Schaefer, P. W., & Gonzalez, R. G. (1998) · Stroke · doi:10.1161/01.str.29.11.2268 · Cited by 370
Self-citationSorensen, A. G., Wu, O., Copen, W. A., Davis, T. L., Gonzalez, R. G., Koroshetz, W. J., Reese, T. G., Rosen, B. R., Wedeen, V. J., & Weisskoff, R. M. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se24785 · Cited by 300
Self-citationComparison of diffusion-weighted MRI and CT in acute stroke
Lansberg, M. G., Albers, G. W., Beaulieu, C., & Marks, M. P. (2000) · Neurology · doi:10.1212/wnl.54.8.1557 · Cited by 299
Systematic review of evidence on thrombolytic therapy for acute ischaemic stroke
Wardlaw, J., Warlow, C., & Counsell, C. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03022-5 · Cited by 287
Diagnosis of acute cerebral infarction: comparison of CT and MR imaging.
Bryan, R. N., Levy, L. M., Whitlow, W. D., Killian, J. M., Preziosi, T. J., & Rosario, J. A. R. (1991) · PubMed · Cited by 275
Normal diffusion-weighted MRI during stroke-like deficits
Ay, H., Buonanno, F. S., Rordorf, G., Schaefer, P. W., Schwamm, L. H., Wu, O., Gonzalez, R. G., Yamada, K., Sorensen, G. A., & Koroshetz, W. J. (1999) · Neurology · doi:10.1212/wnl.52.9.1784 · Cited by 271
Self-citationRordorf, G., Koroshetz, W. J., Copen, W. A., Cramer, S. C., Schaefer, P. W., Budzik, R. F., Schwamm, L. H., Buonanno, F., Sorensen, A. G., & Gonzalez, G. (1998) · Stroke · doi:10.1161/01.str.29.5.939 · Cited by 264
Self-citationMagnetic Resonance Versus Computed Tomographic Imaging in Acute Stroke
Mohr, J. P., Biller, J., Hilal, S. K., Yuh, W. T. C., Tatemichi, T. K., Hedges, S., Tali, E., Nguyen, H., Mun, I., Adams, H. P., et al. (1995) · Stroke · doi:10.1161/01.str.26.5.807 · Cited by 239
MR imaging of cerebral ischemia: findings in the first 24 hours.
Yuh, W. T. C., Crain, M. R., Loes, D. J., Greene, G. M., Ryals, T. J., & Satō, Y. (1991) · PubMed Central · Cited by 233
Schriger, D. L., Kalafut, M., Starkman, S., Krueger, M., & Saver, J. L. (1998) · JAMA · doi:10.1001/jama.279.16.1293 · Cited by 232
Welch, K. M. A., Windham, J., Knight, R. A., Nagesh, V., Hugg, J. W., Jacobs, M., Peck, D., Booker, P., Dereski, M. O., & Levine, S. R. (1995) · Stroke · doi:10.1161/01.str.26.11.1983 · Cited by 217
Diffusion-Weighted MRI in Acute Subcortical Infarction
Singer, M. B., Chong, J., Lu, D., Schonewille, W. J., Tuhrim, S., & Atlas, S. W. (1998) · Stroke · doi:10.1161/01.str.29.1.133 · Cited by 179
Applications of diffusion–perfusion magnetic resonance imaging in acute ischemic stroke
Fisher, M., & Albers, G. W. (1999) · Neurology · doi:10.1212/wnl.52.9.1750 · Cited by 152
Cerebral infarction: time course of signal intensity changes on diffusion-weighted MR images.
Burdette, J. H., Ricci, P. E., Petitti, N., & Elster, A. D. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.3.9725318 · Cited by 151
Tilley, B. C., Lyden, P. D., Brott, T. G., Lü, M., Levine, S. R., & Welch, K. M. A. (1997) · Archives of Neurology · doi:10.1001/archneur.1997.00550240020008 · Cited by 136
Grant, P. E., He, J., Halpern, E. F., Wu, O., Schaefer, P. W., Schwamm, L. H., Budzik, R. F., Sorensen, A. G., Koroshetz, W. J., & González, R. (2001) · Radiology · doi:10.1148/radiol.2211001523 · Cited by 119
Self-citationThe sensitivity and specificity of MRI in stroke
KERTESZ, A. E., Black, S. E., Nicholson, L., et al. (1987) · Neurology · doi:10.1212/wnl.37.10.1580 · Cited by 109
Stroke with negative brain magnetic resonance imaging.
Alberts, M. J., Faulstich, M. E., & Gray, L. L. (1992) · Stroke · doi:10.1161/01.str.23.5.663 · Cited by 61
Thrombolytic Therapy for Ischemic Stroke
Mohr, J. P. (2000) · JAMA · doi:10.1001/jama.283.9.1189 · Cited by 46
Antithrombotic and Thrombolytic Therapy for Ischemic Stroke
Fisher, M. (1999) · Journal of Thrombosis and Thrombolysis · doi:10.1023/a:1008889605137 · Cited by 20
Which Targets Are Relevant for Therapy of Acute Ischemic Stroke?
Fisher, M., & Baron, J. (2000) · Stroke · doi:10.1161/01.str.31.4.983-b · Cited by 10
Langston, J. W., Forno, L. S., Tetrud, J., Reeves, A. G., Kaplan, J. A., & Karluk, D. (1999) · Annals of Neurology · doi:10.1002/1531-8249(199910)46:4 · Cited by 1
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Adams, H. P., del Zoppo, G., Alberts, M. J., Bhatt, D. L., Brass, L., Furlan, A., Grubb, R. L., Higashida, R. T., Jauch, E. C., Kidwell, C., et al. (2007) · Stroke · doi:10.1161/strokeaha.107.181486 · Cited by 2,475
Chalela, J. A., Kidwell, C. S., Nentwich, L. M., Luby, M., Butman, J. A., Demchuk, A. M., Hill, M. D., Patronas, N., Latour, L., & Warach, S. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60151-2 · Cited by 1,301
Adams, H. P., del Zoppo, G., Alberts, M. J., Bhatt, D. L., Brass, L., Furlan, A., Grubb, R. L., Higashida, R. T., Jauch, E. C., Kidwell, C., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181486 · Cited by 904
Automated deep-neural-network surveillance of cranial images for acute neurologic events
Titano, J. J., Badgeley, M., Schefflein, J., Pain, M., Su, A., Cai, M., Swinburne, N., Zech, J., Kim, J., Bederson, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0147-y · Cited by 458
Metadata
- Authors
- Mullins, M. E., Schaefer, P. W., Sorensen, A. G., Halpern, E. F., Ay, H., He, J., Koroshetz, W. J., & Gonzalez, R. G.
- Venue
- Radiology
- Published
- 2002-08
- Volume
- 224
- Issue
- 2
- Pages
- 353-360
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2022123720
- Cited by
- 343
- References
- 39
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.