The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CT
Abstract
PURPOSE: To measure the effective radiation doses delivered at electron-beam computed tomography (CT) and multi-detector row spiral CT of coronary arteries and to compare these doses with those delivered at catheter coronary angiography. MATERIALS AND METHODS: An anthropomorphic phantom equipped with 66 thermoluminescent dosimeters was imaged at cardiac CT. Four protocols for unenhanced coronary artery calcium scoring were simulated: one with electron-beam CT and three with multi-detector row CT. Four similar protocols for coronary CT angiography were simulated. All multi-detector row spiral CT protocols were performed with retrospective electrocardiographic triggering. Biplane catheter coronary angiography also was simulated. Radiation doses to organs were measured, and effective doses were calculated according to guidelines published in International Commission on Radiological Protection Publication 60. RESULTS: Coronary artery calcium scoring with electron-beam CT yielded effective radiation doses of 1.0 and 1.3 mSv for male and female patients, respectively. The radiation doses at calcium scoring with multi-detector row CT were 1.5-5.2 mSv for male patients and 1.8-6.2 mSv for female patients. Electron-beam CT coronary angiography yielded effective doses of 1.5 and 2.0 mSv for male and female patients, respectively. The highest effective doses were delivered at multi-detector row CT angiography: 6.7-10.9 mSv for male patients and 8.1-13.0 mSv for female patients. Catheter coronary angiography yielded effective doses of 2.1 and 2.5 mSv for male and female patients, respectively. CONCLUSION: Higher radiation doses are delivered at multi-detector row cardiac CT compared with the doses delivered at electron-beam CT and catheter coronary angiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,154
Raggi, P., Callister, T. Q., Cooil, B., He, Z.-X., Lippolis, N. J., Russo, D. J., Zelinger, A., & Mahmarian, J. J. (2000) · Circulation · doi:10.1161/01.cir.101.8.850 · Cited by 835
Rumberger, J. A., Brundage, B. H., Rader, D. J., & Kondos, G. (1999) · Mayo Clinic Proceedings · doi:10.4065/74.3.243 · Cited by 796
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Gersh, B. J., Kronmal, R. A., Frye, R. L., Schaff, H. V., Ryan, T. J., Gosselin, A. J., Kaiser, G. C., & Killip, T. (1983) · Circulation · doi:10.1161/01.cir.67.3.483 · Cited by 293
Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT
Becker, C. R., Kleffel, T., Crispin, A., Knez, A., Young, J., Schoepf, U. J., Haberl, R., & Reiser, M. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.5.1761295 · Cited by 282
Complications associated with cardiac catheterization and angiography
Kennedy, J. W. (1982) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810080103 · Cited by 278
Georgiou, D., Budoff, M. J., Kaufer, E., Kennedy, J. M., Lu, B., & Brundage, B. H. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01364-x · Cited by 259
Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy
Nickoloff, E. L., & Alderson, P. O. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770285 · Cited by 220
Moshage, W. E., Achenbach, S., Seese, B., Bachmann, K., & Kirchgeorg, M. (1995) · Radiology · doi:10.1148/radiology.196.3.7644633 · Cited by 205
Tanenbaum, S. R., Kondos, G. T., Veselik, K. E., Prendergast, M. R., Brundage, B. H., & Chomka, E. V. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90060-x · Cited by 181
Schmermund, A., Rensing, B. J., Sheedy, P. F., Bell, M. R., & Rumberger, J. A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00132-6 · Cited by 180
Self-citationSchmermund, A., Denktas, A. E., Rumberger, J. A., Christian, T. F., Sheedy, P. F., Bailey, K. R., & Schwartz, R. S. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00265-x · Cited by 157
Self-citationHunold, P. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2586 · Cited by 152
Self-citationHaaga, J. R. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770289 · Cited by 143
Radiation Exposure and Image Quality in Chest CT Examinations
Ravenel, J. G., Scalzetti, E. M., Huda, W., & Garrisi, W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770279 · Cited by 142
Bielak, L. F., Rumberger, J. A., Sheedy, P. F., Schwartz, R. S., & Peyser, P. A. (2000) · Circulation · doi:10.1161/01.cir.102.4.380 · Cited by 133
Electron-Beam Computed Tomography in the Diagnosis of Coronary Artery Disease: A Meta-analysis
Nallamothu, B. K., Saint, S. K., Bielak, L. F., Sonnad, S. S., Peyser, P. A., Rubenfire, M., & Fendrick, A. M. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.6.833 · Cited by 116
ECG-correlated imaging of the heart with subsecond multislice spiral CT
Kalender, W. A., Ulzheimer, S., & Kachelrieß, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887837 · Cited by 96
Lund, G., Wendland, M. F., Shimakawa, A. S., Arheden, H., Ståhlberg, F., Higgins, C. B., & Saeed, M. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv10487 · Cited by 77
THE TECHNICAL DESIGN AND PERFORMANCE OF ULTRAFAST COMPUTED TOMOGRAPHY
McCollough, C. H., & Morin, R. L. (1994) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)00387-6 · Cited by 66
Assmann, G., Gotto, A. M., & Paoletti, R. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90850-k · Cited by 49
Schroeder, S., Kopp, A. F., Baumbach, A., Kuettner, A., Herdeg, C., Rosenberger, A., Selbmann, H., Claussen, C. D., Oberhoff, M., & Karsch, K. R. (2001) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.1180 · Cited by 45
Drake‐Holland, A. J., NOBLE, M., & Lab, M. J. (2001) · Heart · doi:10.1136/heart.85.5.576 · Cited by 22
Cited by
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Cancer risks from diagnostic radiology
HALL, E. J., & BRENNER, D. J. (2008) · The British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 915
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
Metadata
- Authors
- Hunold, P., Vogt, F. M., Schmermund, A., Debatin, J. F., Kerkhoff, G., Budde, T., Erbel, R., Ewen, K., & Barkhausen, J.
- Venue
- Radiology
- Published
- 2003-01
- Volume
- 226
- Issue
- 1
- Pages
- 145-152
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2005057220
- Cited by
- 405
- References
- 31
- FWCI
- 37.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.