An approach for the estimation of effective radiation dose at CT in pediatric patients.
The DOI matches its Crossref record.
Abstract
PURPOSE: To estimate the effective radiation dose to pediatric and adult patients at head and abdomen computed tomography (CT). MATERIALS AND METHODS: Cylindrical water-equivalent phantoms were modeled for patients aged newborn to adult, and the energy imparted per unit axial exposure was computed. To determine the energy imparted to the simulated patients of different ages undergoing head and abdomen CT examinations, x-ray technique factors were combined with measured CT axial exposures. Body-region-specific ratios were calculated for effective dose per unit energy imparted, and these ratios were corrected for patient mass to obtain the effective dose to simulated patients. RESULTS: With use of standard techniques, the energy imparted to simulated patients at CT always increased with patient size, but the effective dose was higher in children than in adults. At CT in the head and abdomen, effective doses were highest in newborns. Effective doses ranged from 1.5 to 6.0 mSv in head CT examinations and from 3.1 to 5.3 mSv in abdomen CT examinations. CONCLUSION: The values for energy imparted at CT in pediatric patients were generally lower than in adults. The smaller mass of children, however, caused the corresponding effective doses to be higher than those in adults undergoing similar CT examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Self-citationCT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
Radiation Risk to Children From Computed Tomography
Brody, A. S., Frush, D. P., Huda, W., Brent, R. L., & Radiology, A. T. S. O. (2007) · Pediatrics · doi:10.1542/peds.2007-1910 · Cited by 606
Self-citationThe Measurement, Reporting, and Management of Radiation Dose in CT
McCollough, C., Cody, D., Edyvean, S., Geise, R., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W., McNitt-Gray, M., et al. (2008) · doi:10.37206/97 · Cited by 569
Self-citationEstimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 554
Converting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513
Self-citationDedicated Breast CT: Radiation Dose and Image Quality Evaluation
Boone, J. M., Nelson, T. R., Lindfors, K. K., & Seibert, J. A. (2001) · Radiology · doi:10.1148/radiol.2213010334 · Cited by 468
Helical CT of the Body: Are Settings Adjusted for Pediatric Patients?
Paterson, A., Frush, D. P., & Donnelly, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760297 · Cited by 422
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Pulmonary Embolism in Pregnant Patients: Fetal Radiation Dose with Helical CT
Winer-Muram, H. T., Boone, J. M., Brown, H. L., Jennings, S. G., Mabie, W. C., & Lombardo, G. T. (2002) · Radiology · doi:10.1148/radiol.2242011581 · Cited by 329
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Heyer, C. M., Mohr, P. S., Lemburg, S. P., Peters, S. A., & Nicolas, V. (2007) · Radiology · doi:10.1148/radiol.2452061919 · Cited by 274
Patient Radiation Doses from Adult and Pediatric CT
Huda, W., & Vance, A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0101 · Cited by 251
“The mean section dose, Dm, is defined as the total energy deposited in the water cylinder divided by the mass of the directly irradiated volume, or π r2 T ρ, where T is the section thickness and ρ is the water density [20].”
BackgroundMethodInfluentialSelf-citationExposing the Thyroid to Radiation: A Review of Its Current Extent, Risks, and Implications
Sinnott, B., Ron, E., & Schneider, A. B. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0003 · Cited by 246
“Effective doses from CT scans that are not modified for pediatric patients are higher in children because of their smaller organs and masses compared with adults (18, 19).”
BackgroundLow-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic
Tack, D., Sourtzis, S., Delpierre, I., de Maertelaer, V., & Gevenois, P. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800305 · Cited by 225
Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy
Nickoloff, E. L., & Alderson, P. O. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770285 · Cited by 220
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
“[58,59] nd estimates of E normalised to DLP (E/DLP) and to unit energy mparted are published for different patient sizes [37,44,60,61].”
BackgroundLucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.4.1750985 · Cited by 165
“Radiation exposure is particularly worrisome in children, in whom absorbed CT dose is more uniform, effective dose is higher, and risk of radiation-induced damage is considered greater than in adults [21, 22].”
BackgroundComparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults
Menke, J. (2005) · Radiology · doi:10.1148/radiol.2362041327 · Cited by 164
Metadata
- Authors
- Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A.
- Venue
- Radiology
- Published
- 1997-05
- Volume
- 203
- Issue
- 2
- Pages
- 417-422
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2034118992
- Cited by
- 217
- References
- 0
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.