MR Imaging of Human Brain at 3.0 T: Preliminary Report on Transverse Relaxation Rates and Relation to Estimated Iron Content
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the transverse relaxation rates R2 and R2' from several gray matter regions and from frontal cortical white matter in healthy human brains in vivo and to determine the relationship between relaxation rates and iron concentration [Fe]. MATERIALS AND METHODS: Six healthy adults aged 19-42 years underwent thin-section gradient-echo sampling of free induction decay and echo magnetic resonance (MR) imaging at 3.0 T. Imaging covered the mesencephalon and basal ganglia. RESULTS: Relaxation rates (mean +/- SD) were highest in globus pallidus (R2 = 25.8 seconds-1 +/- 1.1, R2' = 12.0 seconds-1 +/- 2.1) and lowest in prefrontal cortex (R2 = 14.4 seconds-1 +/- 1.8, R2' = 3.4 seconds-1 +/- 1.1). Frontal white matter measurements were as follows: R2 = 18.0 seconds-1 +/- 1.2 and R2' = 3.9 seconds-1 +/- 1.2. For gray matter, both R2 and R2' showed a strong correlation (r = 0.92, P < .001 and r = 0.90, P < .001, respectively) with [Fe]. Although the slopes of the regression lines for R2' versus [Fe] and for R2 versus [Fe] were similar, the iron-independent component of R2' (2.2 seconds-1 +/- 0.6), the value when [Fe] = 0, was much less than that of R2 (12.7 seconds-1 +/- 0.7). CONCLUSION: The small iron-independent component R2', as compared with that of R2, is consistent with the hypothesis that R2' has higher iron-related specificity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of age on the non-haemin iron in the human brain
Hallgren, B., & Sourander, P. (1958) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1958.tb12607.x · Cited by 1,427
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Altered Brain Metabolism of Iron as a Cause of Neurodegenerative Diseases?
Gerlach, M., Ben‐Shachar, D., Riederer, P., & Youdim, M. B. H. (1994) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1994.63030793.x · Cited by 703
High frequency volume coils for clinical NMR imaging and spectroscopy
Vaughan, J. T., Hetherington, H. P., Otu, J. O., Pan, J. W., & Pohost, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320209 · Cited by 374
Increased iron‐related MRI contrast in the substantia nigra in Parkinson's disease
Gorell, J. M., Ordidge, R. J., Brown, G. G., Deniau, J.-C., Buderer, N. M., & Helpern, J. A. (1995) · Neurology · doi:10.1212/wnl.45.6.1138 · Cited by 324
Self-citationAssessment of relative brain iron concentrations using T2‐weighted and T2*‐weighted MRI at 3 Tesla
Ordidge, R. J., Gorell, J. M., Deniau, J. C., Knight, R. A., & Helpern, J. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320309 · Cited by 323
Self-citationTheory and application of static field inhomogeneity effects in gradient‐echo imaging
Reichenbach, J. R., Venkatesan, R., Yablonskiy, D. A., Thompson, M. R., Lai, S., & Haacke, E. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070203 · Cited by 285
Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
Frahm, J., Merboldt, K., & Hänicke, W. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060412 · Cited by 228
MR evaluation of age-related increase of brain iron in young adult and older normal males
Bartzokis, G., Beckson, M., Hance, D. B., Marx, P., Foster, J. A., & Marder, S. R. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00234-2 · Cited by 181
The relation between brain iron and NMR relaxation times: An in vitro study
Vymazal, J., Brooks, R. A., Baumgarner, C., Tran, V., Katz, D., Bulte, J. W. M., Bauminger, E. R., & Chiro, G. D. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350108 · Cited by 172
Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores
Bartzokis, G., Aravagiri, M., Oldendorf, W. H., Mintz, J., & Marder, S. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290406 · Cited by 172
Reduction of susceptibility artifact in gradient‐echo imaging
Cho, Z. H., & Ro, Y. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230120 · Cited by 165
Magnetization Transfer and T2 Relaxation Components in Tissue
Harrison, R., Bronskill, M. J., & Henkelman, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330406 · Cited by 158
Ma, J., & Wehrli, F. W. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0060 · Cited by 156
Bizzi, A., Brooks, R. A., Brunetti, A., Hill, J. M., Alger, J. R., Miletich, R. S., Francavilla, T. L., & Di Chiro, G. (1990) · Radiology · doi:10.1148/radiology.177.1.2399339 · Cited by 151
In vivo MR evaluation of age-related increases in brain iron.
Bartzokis, G., Mintz, J., Sultzer, D. L., Marx, P., Herzberg, J., Phelan, C., & Marder, S. R. (1994) · PubMed Central · Cited by 150
Age distribution and iron dependency of the T2 relaxation time in the globus pallidus and putamen
Schenker, C., Meier, D., Wichmann, W., Boesiger, P., & Valavanis, A. (1993) · Neuroradiology · doi:10.1007/bf00593967 · Cited by 147
In vivo evaluation of brain iron in Alzheimer's disease and normal subjects using MRI
Bartzokis, G., Sultzer, D. L., Mintz, J., Holt, L. E., Marx, P., Phelan, C., & Marder, S. R. (1994) · Biological Psychiatry · doi:10.1016/0006-3223(94)90047-7 · Cited by 140
YOUNG, I. R., Cox, I. J., Bryant, D. J., & Bydder, G. M. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90133-6 · Cited by 119
An MRI method for measuring T 2 in the presence of static and RF magnetic field Inhomogeneities
Yablonskiy, D. A., & Haacke, E. M. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370611 · Cited by 109
Three‐dimensional mapping of the static magnetic field inside the human head
Li, S., Dardzinski, B. J., Collins, C. M., Yang, Q., & Smith, M. B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360509 · Cited by 105
Thomas, L. E., Boyko, O. B., Anthony, D. C., & Burger, P. C. (1993) · PubMed Central · Cited by 104
Magnetic resonance imaging of brain iron in health and disease
Vymazal, J., Brooks, R. A., Patronas, N. J., Hájek, M., Bulte, J. W. M., & Chiro, G. D. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00204-f · Cited by 102
Imaging of brain iron by magnetic resonance: T2 relaxation at different field strengths
Schenck, J. F. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00203-e · Cited by 91
(1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050514 · Cited by 88
Basal ganglia iron content in Parkinson's disease measured with magnetic resonance
Ye, F. Q., Allen, P. S., & Martin, W. R. W. (1996) · Movement Disorders · doi:10.1002/mds.870110305 · Cited by 88
Comparison of t2 relaxation in blood, brain, and ferritin
Brooks, R. A., Vymazal, J., Baumgarner, C. D., Tran, V., & Bulte, J. W. M. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050414 · Cited by 76
Estimation of brain iron in vivo by means of the interecho time dependence of image contrast
Ye, F. Q., Martin, W. R. W., & Allen, P. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360124 · Cited by 48
Ye, F. Q., Martin, W. R. W., & Allen, P. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350304 · Cited by 35
Punwani, S., Cooper, C. E., Clemence, M., Penrice, J., Amess, P., Thornton, J. S., & Ordidge, R. J. (1997) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-0056-2_14 · Cited by 30
Cited by
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Periaqueductal Gray Matter Dysfunction in Migraine: Cause or the Burden of Illness?
Welch, K. M. A., Nagesh, V., Aurora, S. K., & Gelman, N. (2001) · Headache: The Journal of Head and Face Pain · doi:10.1046/j.1526-4610.2001.041007629.x · Cited by 623
Self-citationMRI measurement of brain iron in patients with restless legs syndrome
Allen, R. P., Barker, P. B., Wehrl, F., Song, H. K., & Earley, C. J. (2001) · Neurology · doi:10.1212/wnl.56.2.263 · Cited by 570
Self-citationBiophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Metadata
- Authors
- Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A.
- Venue
- Radiology
- Published
- 1999-03
- Volume
- 210
- Issue
- 3
- Pages
- 759-767
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2160027020
- Cited by
- 373
- References
- 30
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.