Hypoxia reduces potassium currents in cultured rat pulmonary but not mesenteric arterial myocytes
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
To explore possible mechanisms underlying hypoxia-induced pulmonary vasoconstriction, the effect of hypoxia on outward K+ current (Iout) was evaluated in primary cultured rat pulmonary (PA) and mesenteric (MA) arterial smooth muscle cells using the whole cell patch-clamp technique. When the cells were bathed in standard physiological salt solution and the patch pipettes contained Ca(2+)-free media with 10 mM ethylene glycol-bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA), virtually all of the Iout, including both the rapidly inactivating component (Irt) and the steady-state (noninactivating) component (Iss), was mediated by voltage-gated K+ channels. Reduction of O2 tension in the bath solution from 155 Torr to < 74 Torr with sodium dithionite reversibly inhibited both Irt and Iss in PA myocytes, but not in MA myocytes. The hypoxia-sensitive Iss was activated at about -50 mV; thus, some of the channels responsible for this current may be open at the resting membrane potential (-40 +/- 1 mV) of PA cells used in this study. Hypoxia also significantly depolarized PA cells bathed in PSS (1.8 mM Ca2+) from -40.7 +/- 1.3 to -24.0 +/- 2.4 mV, and PA cells bathed in Ca(2+)-free PSS (0.1 mM EGTA) from -38.4 +/- 1.3 to -26.1 +/- 3.9 mV. The hypoxia-induced inhibition of Iout in PA cells was accompanied by an apparent increase in inward Ca2+ current.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Hyperpolarizing Vasodilators Activate ATP-sensitive K + Channels in Arterial Smooth Muscle
Standen, N. B., Quayle, J. M., Davies, N. W., Brayden, J. E., Huang, Y., & Nelson, M. T. (1989) · Science · doi:10.1126/science.2501869 · Cited by 1,190
Calcium channels, potassium channels, and voltage dependence of arterial smooth muscle tone
Nelson, M. T., Patlak, J. B., Worley, J. F., & Standen, N. B. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.259.1.c3 · Cited by 1,096
The Function of Myosin and Myosin Light Chain Kinase Phosphorylation in Smooth Muscle
Kamm, K. E., & Stull, J. T. (1985) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pa.25.040185.003113 · Cited by 1,065
Regulation of Arterial Tone by Activation of Calcium-Dependent Potassium Channels
Brayden, J. E., & Nelson, M. T. (1992) · Science · doi:10.1126/science.1373909 · Cited by 932
Hypoxic Dilation of Coronary Arteries Is Mediated by ATP-Sensitive Potassium Channels
Daut, J., Maier-Rudolph, W., von Beckerath, N., Mehrke, G., Günther, K., & Goedel-Meinen, L. (1990) · Science · doi:10.1126/science.2107575 · Cited by 593
Direct role for potassium channel inhibition in hypoxic pulmonary vasoconstriction
Post, J. M., Hume, J. R., Archer, S. L., & Weir, E. K. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.4.c882 · Cited by 451
López-López, J., González, C., Ureña, J., & López-Barneo, J. (1989) · The Journal of general physiology · doi:10.1085/jgp.93.5.1001 · Cited by 203
Single K+ channels in membrane patches of arterial chemoreceptor cells are modulated by O2 tension.
Ganfornina, M. D., & López-Barneo, J. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.7.2927 · Cited by 158
Davies, N. W., Standen, N. B., & Stanfield, P. R. (1991) · Journal of Bioenergetics and Biomembranes · doi:10.1007/bf00785809 · Cited by 155
Acute hypoxia increases cytosolic calcium in cultured pulmonary arterial myocytes
Salvaterra, C. G., & Goldman, W. F. (1993) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1993.264.3.l323 · Cited by 145
Self-citationRedox status in the control of pulmonary vascular tone.
Archer, S., Will, J. A., & Weir, E. K. (1986) · PubMed · Cited by 141
Contrasting effects of hypoxia on tension in rat pulmonary and mesenteric arteries
Yuan, X. J., Tod, M. L., Rubin, L. J., & Blaustein, M. P. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.259.2.h281 · Cited by 133
Self-citationHypoxic contraction of isolated rat pulmonary artery.
Rodman, D. M., Yamaguchi, T., OʼBrien, R. F., & McMurtry, I. F. (1989) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)24171-4 · Cited by 127
Effects of K+ Channel Blockers on Vascular Tone in the Perfused Rat Lung
Hasunuma, K., Rodman, D. M., & McMurtry, I. F. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.4.884 · Cited by 109
Hypoxic induction of Ca2+-dependent action potentials in small pulmonary arteries of the cat
Harder, D. R., Madden, J. A., & Dawson, C. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1389 · Cited by 105
Hypoxic Contraction of Cultured Pulmonary Vascular Smooth Muscle Cells
Murray, T., Chen, L., Marshall, B. E., & Macarak, E. J. (1990) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb/3.5.457 · Cited by 103
von Beckerath, N., Cyrys, S., Dischner, A., & Daut, J. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018794 · Cited by 100
Energy state and vasomotor tone in hypoxic pig lungs
Buescher, P. C., Pearse, D. B., Pillai, R. P., Litt, M. C., Mitchell, M. C., & Sylvester, J. T. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.4.1874 · Cited by 53
Cited by
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Cellular Mechanism of Oxygen Sensing
López-Barneo, J., Pardal, R., & Ortega-Sáenz, P. (2001) · Annual Review of Physiology · doi:10.1146/annurev.physiol.63.1.259 · Cited by 544
Acute Oxygen-Sensing Mechanisms
Weir, E. K., López-Barneo, J., Buckler, K. J., & Archer, S. L. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050002 · Cited by 492
Archer, S. L., Souil, E., Dinh-Xuan, A. T., Schremmer, B., Mercier, J. C., El Yaagoubi, A., Nguyen-Huu, L., Reeve, H. L., & Hampl, V (1998) · Journal of Clinical Investigation · doi:10.1172/jci333 · Cited by 410
A redox-based O2 sensor in rat pulmonary vasculature.
Archer, S. L., Huang, J., Henry, T., Peterson, D., & Weir, E. K. (1993) · Circulation Research · doi:10.1161/01.res.73.6.1100 · Cited by 362
Metadata
- Authors
- Yuan, X. J., Goldman, W. F., Tod, M. L., Rubin, L. J., & Blaustein, M. P.
- Venue
- American Journal of Physiology-Lung Cellular and Molecular Physiology
- Publisher
- American Physiological Society
- Published
- 1993-02-01
- Volume
- 264
- Issue
- 2
- Pages
- L116-L123
- ISSN
- 1040-0605 (ISSN-L)
- 1522-1504
- OpenAlex
- W2184358523
- Cited by
- 282
- References
- 19
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.