Simulations of light effects on the human circadian pacemaker: implications for assessment of intrinsic period
The DOI matches its Crossref record.
Abstract
The sensitivity of the human circadian system to light has been the subject of considerable debate. Using computer simulations of a recent quantitative model for the effects of light on the human circadian system, we investigated these effects of light during different experimental protocols. The results of the simulations indicate that the nonuniform distribution over the circadian cycle of exposure to ordinary room light seen in classical free-run studies, in which subjects select their exposure to light and darkness, can result in an observed period of approximately 25 h, even when the intrinsic period of the subject's endogenous circadian pacemaker is much closer to 24 h. Other simulation results suggest that accurate assessment of the true intrinsic period of the human circadian pacemaker requires low ambient light intensities (approximately 10-15 lx) during scheduled wake episodes, desynchrony of the imposed light-dark cycle from the endogenous circadian oscillator, and a study length of at least 20 days. Although these simulations await further experimental substantiation, they highlight the sensitivity to light of the human circadian system and the potential confounding influence of light on the assessment of the intrinsic period of the circadian pacemaker.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sleep Homeostasis and Models of Sleep Regulation
Borb, A. A., & Achermann, P. (1999) · Journal of Biological Rhythms · doi:10.1177/074873099129000894 · Cited by 1,472
Sex difference in the near-24-hour intrinsic period of the human circadian timing system
Duffy, J. F., Cain, S. W., Chang, A.-M., Phillips, A. J. K., Münch, M. Y., Gronfier, C., Wyatt, J. K., Dijk, D.-J., Wright, K. P., & Czeisler, C. A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1010666108 · Cited by 607
Self-citationA CLOCK Polymorphism Associated with Human Diurnal Preference
Katzenberg, D., Young, T., Finn, L., Lin, L., King, D. P., Takahashi, J. S., & Mignot, E. (1998) · Sleep · doi:10.1093/sleep/21.6.569 · Cited by 591
Familial advanced sleep-phase syndrome: a short-period circadian rhythm variant in humans
Jones, C. R., Campbell, S. S., Zone, S. E., Cooper, F., DeSano, A., Murphy, P. J., Jones, B., Czajkowski, L., & Ptček, L. J. (1999) · Nature Medicine · doi:10.1038/12502 · Cited by 567
Entrainment of the human circadian system by light
Duffy, J. F., & Wright, K. P. (2005) · Journal of Biological Rhythms · doi:10.1177/0748730405277983 · Cited by 515
“In fact, 3 subjects who were studied in both forced desynchrony and free-run studies were reported to have 24.5-h periods using the forced desynchrony protocol but near 25-h periods using a free-run protocol (Klerman et al., 1996).”
BackgroundMethodInfluentialWyatt, J. K., Cecco, A. R.-D., Czeisler, C. A., & Dijk, D.-J. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.277.4.r1152 · Cited by 473
Self-citationPhillips, A. J. K., Vidafar, P., Burns, A. C., McGlashan, E. M., Anderson, C., Rajaratnam, S. M. W., Lockley, S. W., & Cain, S. W. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1901824116 · Cited by 430
Sleep and Circadian Rhythms in Humans
Czeisler, C. A., & Gooley, J. J. (2007) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.2007.72.064 · Cited by 425
Self-citationModeling of a Human Circadian Mutation Yields Insights into Clock Regulation by PER2
Xu, Y., Toh, K. L., Jones, C. R., Shin, J.-Y., Fu, Y.-H., & Ptáček, L. J. (2007) · Cell · doi:10.1016/j.cell.2006.11.043 · Cited by 405
Social influences on mammalian circadian rhythms: animal and human studies
Mistlberger, R. E., & Skene, D. J. (2004) · Biological Reviews · doi:10.1017/s1464793103006353 · Cited by 404
Invited Review: Integration of human sleep-wake regulation and circadian rhythmicity
Dijk, D.-J., & Lockley, S. W. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00924.2001 · Cited by 396
Self-citationA specific role for the thalamus in mediating the interaction of attention and arousal in humans.
Portas, C. M., Rees, G., Howseman, A. M., Josephs, O., Turner, R., & Frith, C. D. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08979.1998 · Cited by 395
“Subjects were sleep-deprived under continuous supervision for a short period (24 hr) in a quiet environment and in conditions of moderate light to avoid the resetting of the circadian pacemaker (Klerman et al., 1996).”
Complex Interaction of the Sleep-Wake Cycle and Circadian Phase Modulates Mood in Healthy Subjects
Boivin, D. B. (1997) · Archives of General Psychiatry · doi:10.1001/archpsyc.1997.01830140055010 · Cited by 378
CONTRIBUTION OF CIRCADIAN PHYSIOLOGY AND SLEEP HOMEOSTASIS TO AGE-RELATED CHANGES IN HUMAN SLEEP
Dijk, D.-J., Duffy, J. F., & Czeisler, C. A. (2000) · Chronobiology International · doi:10.1081/cbi-100101049 · Cited by 370
Self-citationNonphotic Entrainment in Humans?
Mistlberger, R. E., & Skene, D. J. (2005) · Journal of Biological Rhythms · doi:10.1177/0748730405277982 · Cited by 267
Wright, K. P., Hughes, R. J., Kronauer, R. E., Dijk, D.-J., & Czeisler, C. A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.201530198 · Cited by 255
Self-citationNonphotic entrainment of the human circadian pacemaker
Klerman, E. B., Rimmer, D. W., Dijk, D.-J., Kronauer, R. E., Rizzo, J. F., & Czeisler, C. A. (1998) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1998.274.4.r991 · Cited by 217
Self-citationKronauer, R. E., Forger, D. B., & Jewett, M. E. (1999) · Journal of Biological Rhythms · doi:10.1177/074873099129001073 · Cited by 185
Self-citationThe Human Circadian Timing System and Sleep–Wake Regulation
Czeisler, C. A., & Buxton, O. M. (2011) · Principles and Practice of Sleep Medicine · doi:10.1016/b978-1-4160-6645-3.00035-9 · Cited by 182
Self-citationWyatt, J. K., Cajochen, C., Cecco, A. R.-D., Czeisler, C. A., & Dijk, D.-J. (2004) · Sleep · doi:10.1093/sleep/27.3.374 · Cited by 182
Self-citationWyatt, J. K., Dijk, D.-J., Cecco, A. R.-D., Ronda, J. M., & Czeisler, C. A. (2006) · Sleep · doi:10.1093/sleep/29.5.609 · Cited by 176
Self-citationRevised Limit Cycle Oscillator Model of Human Circadian Pacemaker
Jewett, M. E., Forger, D. B., & Kronauer, R. E. (1999) · Journal of Biological Rhythms · doi:10.1177/074873049901400608 · Cited by 172
“This model was able to predict many findings (Klerman et al., 1996), such as the type 0 response to a three-cycle bright light stimulus (Czeisler et al., 1989) and the ability of a critical bright light stimulus to reduce amplitude (Jewett et al., 1991).”
MethodSelf-citationDijk, D.-J., Duffy, J. F., Silva, E. J., Shanahan, T. L., Boivin, D. B., & Czeisler, C. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030037 · Cited by 170
Self-citationJewett, M. E., Rimmer, D. W., Duffy, J. F., Klerman, E. B., Kronauer, R. E., & Czeisler, C. A. (1997) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1997.273.5.r1800 · Cited by 166
Self-citationA Simpler Model of the Human Circadian Pacemaker
Forger, D. B., Jewett, M. E., & Kronauer, R. E. (1999) · Journal of Biological Rhythms · doi:10.1177/074873099129000867 · Cited by 163
“Although many other cubic and higher order van der Pol models have used a stiffness of 0.13 (including Kronauer, 1990; Klerman et al., 1996; Jewett and Kronauer, 1998), other reports lead us to believe that a larger stiffness is acceptable.”
BackgroundMethodInfluentialSelf-citationComparative study to determine the optimal melatonin dosage form for the alleviation of jet lag
Suhner, A., Schlagenhauf, P., Johnson, R., Tschopp, A., & Steffen, R. (1998) · Chronobiology International · doi:10.3109/07420529808993201 · Cited by 147
Hasan, S., Santhi, N., Lazar, A. S., Slak, A., Lo, J., von Schantz, M., Archer, S. N., Johnston, J. D., & Dijk, D. (2012) · The FASEB Journal · doi:10.1096/fj.11-201699 · Cited by 68
“Theoretically, the latter protocol should provide the most robust assessment of central circadian period (19, 51).”
BackgroundMethodSelf-citationThe Human Circadian Timing System and Sleep-Wake Regulation
Czeisler, C. A., Buxton, O. M., & Khalsa, S. B. S. (2005) · Principles and Practice of Sleep Medicine · doi:10.1016/b0-72-160797-7/50038-0 · Cited by 67
Self-citationLazar, A. S., Santhi, N., Hasan, S., Lo, J. C. ‐., Johnston, J. D., Von Schantz, M., Archer, S. N., & Dijk, D. (2013) · Journal of Sleep Research · doi:10.1111/jsr.12001 · Cited by 59
“…circadian rhythms, and allows the assessment of the near-24-h circadian period of the hypothalamic circadian pacemaker driving circadian rhythms such as plasma melatonin when the desynchrony is at least one beat cycle long as in the current protocol (Dijk and Czeisler, 1995; Klerman et al., 1996).”
BackgroundSelf-citationSwaminathan, K., Klerman, E. B., & Phillips, A. J. K. (2017) · Journal of Biological Rhythms · doi:10.1177/0748730417699310 · Cited by 45
“Recorded patterns of self-selected light in time-free laboratory conditions have been used as inputs to a model of the circadian pacemaker to explain the circadian period observed under those conditions (Klerman et al., 1996).”
MethodSelf-citationKoorengevel, K. M., Beersma, D. G. M., den Boer, J. A., & van den Hoofdakker, R. H. (2003) · Psychiatry Research · doi:10.1016/s0165-1781(02)00305-0 · Cited by 42
Metadata
- Authors
- Klerman, E. B., Dijk, D. J., Kronauer, R. E., & Czeisler, C. A.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1996-01-01
- Volume
- 270
- Issue
- 1
- Pages
- R271-R282
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W1937375692
- Cited by
- 120
- References
- 0
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.