A hydrodynamic mechanosensory hypothesis for brush border microvilli
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
In the proximal tubule of the kidney, Na+ and HCO 3 − reabsorption vary proportionally with changes in axial flow rate. This feature is a critical component of glomerulotubular balance, but the basic mechanism by which the tubule epithelial cells sense axial flow remains unexplained. We propose that the microvilli, which constitute the brush border, are physically suitable to act as a mechanosensor of fluid flow. To examine this hypothesis quantitatively, we have developed an elastohydrodynamic model to predict the forces and torques along each microvillus and its resulting elastic bending deformation. This model indicates that: 1) the spacing of the microvilli is so dense that there is virtually no axial velocity within the brush border and that drag forces on the microvilli are at least 200 times greater than the shear force on the cell's apical membrane at the base of the microvilli; 2) of the total drag on a 2.5-μm microvillus, 74% appears within 0.2 μm from the tip; and 3) assuming that the structural strength of the microvillus derives from its axial actin filaments, then a luminal fluid flow of 30 nl/min produces a deflection of the microvillus tip which varies from about 1 to 5% of its 90-nm diameter, depending on the microvilli length. The microvilli thus appear as a set of stiff bristles, in a configuration in which changes in drag will produce maximal torque.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802 · cited 3×
“uc~r! 5 S2 14 dp dzD~rL2 2 r(2)! 2 S 1 a(2) dp dzDC3 (10)”
BackgroundInfluentialFlexural rigidity of microtubules and actin filaments measured from thermal fluctuations in shape.
Gittes, F., Mickey, B., Nettleton, J., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.4.923 · Cited by 1,817
The Dynamic Response of Vascular Endothelial Cells to Fluid Shear Stress
Dewey, C. F., Bussolari, S. R., Gimbrone, M. A., & Davies, P. F. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138276 · Cited by 1,136 · cited 1×
“(11) first demonstrated that vascular endothelial cells could be grown in culture and exposed to fluid shear under carefully controlled conditions.”
BackgroundForce measurements by micromanipulation of a single actin filament by glass needles
Kishino, A., & Yanagida, T. (1988) · Nature · doi:10.1038/334074a0 · Cited by 679
Slow flow past periodic arrays of cylinders with application to heat transfer
Sangani, A. S., & Acrivos, A. (1982) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(82)90029-5 · Cited by 631
Shear stress regulation of artery lumen diameter in experimental atherogenesis
Zarins, C. K., Zatina, M. A., Giddens, D. P., Ku, D. N., & Glagov, S. (1987) · Journal of Vascular Surgery · doi:10.1016/0741-5214(87)90048-6 · Cited by 582 · cited 1×
“These wall shear variations lead to short-term biochemical responses and, in large vessels, endothelialdependent adaptive remodeling after longer exposure to changes in wall shear stress (55).”
BackgroundHickman, C. P., & Trump, B. F. (1969) · Fish Physiology · doi:10.1016/s1546-5098(08)60083-7 · Cited by 414
Adaptive regulation of wall shear stress optimizing vascular tree function
Kamiya, A., Bukhari, R., & Togawa, T. (1984) · Bulletin of Mathematical Biology · doi:10.1007/bf02463726 · Cited by 298 · cited 1×
“One of the remarkable features of the circulation is that, although the blood vessels undergo more than 20 generations of branching, the fluid shear stress is nearly constant throughout the entire arterial side of the vasculature (21).”
BackgroundTheoretical estimates of mechanical properties of the endothelial cell cytoskeleton
Satcher, R. L., & Dewey, C. F. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79206-8 · Cited by 268 · cited 3×
“In this study we have used the calculation in Satcher and Dewey (47), which assumes an effective radius of 3.5 nm, since this corresponds closely to the measurements reported in Refs.”
MethodInfluential
Cited by
Bending the MDCK Cell Primary Cilium Increases Intracellular Calcium
Praetorius, H. A., & Spring, K. R. (2001) · Journal of Membrane Biology · doi:10.1007/s00232-001-0075-4 · Cited by 828
Mechanisms of Mechanotransduction
Orr, A. W., Helmke, B. P., Blackman, B. R., & Schwartz, M. A. (2006) · Developmental Cell · doi:10.1016/j.devcel.2005.12.006 · Cited by 798
Mechanotransduction and flow across the endothelial glycocalyx
Weinbaum, S., Zhang, X., Han, Y., Vink, H., & Cowin, S. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1332808100 · Cited by 579
Self-citationYou, L., Cowin, S. C., Schaffler, M. B., & Weinbaum, S. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00107-5 · Cited by 418
Self-citationMicrobial Responses to Microgravity and Other Low-Shear Environments
Nickerson, C. A., Ott, C. M., Wilson, J. W., Ramamurthy, R., & Pierson, D. L. (2004) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.68.2.345-361.2004 · Cited by 393
Barrila, J., Radtke, A. L., Crabbé, A., Sarker, S. F., Herbst-Kralovetz, M. M., Ott, C. M., & Nickerson, C. A. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2423 · Cited by 302
Liu, W., Xu, S., Woda, C., Kim, P., Weinbaum, S., & Satlin, L. M. (2003) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00067.2003 · Cited by 232
“(12) developed a theoretical model to describe the flow in the proximal tubule and the forces and torques acting on the brush-border microvilli.”
BackgroundMethodInfluentialSelf-citationMarzorati, M., Vanhoecke, B., De Ryck, T., Sadaghian Sadabad, M., Pinheiro, I., Possemiers, S., Van den Abbeele, P., Derycke, L., Bracke, M., Pieters, J., et al. (2014) · BMC Microbiology · doi:10.1186/1471-2180-14-133 · Cited by 206
“In fact, in absence of microvilli, the fluid shear stress would vary from about 1 to 5 dynes/cm(2) [35].”
Biomechanics: Cell Research and Applications for the Next Decade
Discher, D., Dong, C., Fredberg, J. J., Guilak, F., Ingber, D., Janmey, P., Kamm, R. D., Schmid-Schönbein, G. W., & Weinbaum, S. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9661-x · Cited by 192
Self-citationDuan, Y., Gotoh, N., Yan, Q., Du, Z., Weinstein, A. M., Wang, T., & Weinbaum, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804954105 · Cited by 185
“The combined moment is comparable to that in vivo where the rotational moment is, nearly exclusively, because of the drag acting on the tips of the microvilli at the edge of the brush border (outer 10%) (13), and the lever arms from the base of the cell are nearly the same for both force components.”
BackgroundSelf-citationMacromolecules at surfaces: Research challenges and opportunities from tribology to biology
Granick, S., Kumar, S. K., Amis, E. J., Antonietti, M., Balazs, A. C., Chakraborty, A. K., Grest, G. S., Hawker, C., Janmey, P., Kramer, E. J., et al. (2003) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.10669 · Cited by 184
Pazour, G. J. (2004) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000141055.57643.e0 · Cited by 178
“Whether these microvilli play a sensory role remains to be determined, but it has been hypothesized that they could serve as flow sensors (7) much the way cilia have been proposed to be flow sensors (8).”
BackgroundWilson, J. W., Ramamurthy, R., Porwollik, S., McClelland, M., Hammond, T., Allen, P., Ott, C. M., Pierson, D. L., & Nickerson, C. A. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.212387899 · Cited by 172
Liu, W., Murcia, N. S., Duan, Y., Weinbaum, S., Yoder, B. K., Schwiebert, E., & Satlin, L. M. (2005) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00260.2004 · Cited by 161
“(7) and summarized in the appendix to Ref.”
BackgroundSelf-citationMechanotransduction in the renal tubule
Weinbaum, S., Duan, Y., Satlin, L. M., Wang, T., & Weinstein, A. M. (2010) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00453.2010 · Cited by 158
Self-citationA multi-chamber microfluidic intestinal barrier model using Caco-2 cells for drug transport studies
Tan, H.-Y., Trier, S., Rahbek, U. L., Dufva, M., Kutter, J. P., & Andresen, T. L. (2018) · PLOS ONE · doi:10.1371/journal.pone.0197101 · Cited by 143
Metadata
- Authors
- Guo, P., Weinstein, A. M., & Weinbaum, S.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 2000-10-01
- Volume
- 279
- Issue
- 4
- Pages
- F698-F712
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W2137099290
- Cited by
- 177
- References
- 31
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.