Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Changes in tissue oxygenation of forearm muscles were measured by near infrared (NIR) spectrophotometry in 10 healthy adults during tourniquet ischemia and venous outflow restriction. Muscle O2 stores were depleted rapidly by forearm ischemia manifest by a progressive decrease in tissue oxyhemoglobin and oxymyoglobin over 4–5 min. Muscle ischemia significantly decreased the oxidation level of cytochrome aa3, to below resting base line after only 1.5 min, and the enzyme became fully reduced after 6.5 min. After 8 min of ischemia, tourniquet release was accompanied by a transient increase in muscle blood volume due to influx of oxyhemoglobin. The cytochrome aa3 oxidation level increased above resting base line within 1 min after tourniquet release. Transcutaneous PO2 measurements recorded simultaneously from the same forearm correlated poorly with the kinetics of O2 availability and cytochrome oxidation in the underlying muscle tissue; this was not unexpected because overlying skin did not contribute significantly to NIR muscle signals. Venous outflow restriction without inflow obstruction increased muscle deoxyhemoglobin and tissue blood volume but did not change muscle O2 stores or cytochrome aa3 oxidation level. The ability of the NIR technique to detect dynamic trends in tissue oxygenation reveals that muscle O2 is rapidly consumed during tourniquet ischemia and rapidly restored by hyperemic responses after brief ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The resistance to oxygen transport in the capillaries relative to that in the surrounding tissue
Hellums, J. D. (1977) · Microvascular Research · doi:10.1016/0026-2862(77)90122-4 · Cited by 159
NADH and NADPH in human skeletal muscle at rest and during ischaemia
Sahlin, K. (1983) · Clinical Physiology · doi:10.1111/j.1475-097x.1983.tb00856.x · Cited by 49
Oxygen transport in rest-work transition illustrates new functions for myoglobin
Gayeski, T. E., Connett, R. J., & Honig, C. R. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.6.h914 · Cited by 46
Response of cyt a,a3 in the in situ canine heart to transient ischemic episodes
Snow, T. R., Kleinman, L. H., LaManna, J. C., Wechsler, A. S., & Jöbsis, F. F. (1981) · Basic Research in Cardiology · doi:10.1007/bf01907773 · Cited by 21
Cited by
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Zonios, G., Bykowski, J., & Kollias, N. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2001.01577.x · Cited by 477
Sander, M., Chavoshan, B., Harris, S. A., Iannaccone, S. T., Stull, J. T., Thomas, G. D., & Victor, R. G. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.250379497 · Cited by 445
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Matcher, S. J., Cope, M., & Delpy, D. T. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/011 · Cited by 323
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Self-citationFlexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galan, T., Gupta, S., Montagut, M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 298
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
“The results obtained in these tests agree with the studies reported in the literature on pressure-cuff–induced ischemia (20, 24, 30, 31).”
ResultFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Tanimoto, M., & Ishii, N. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00741.2005 · Cited by 269
Wilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Oxidative metabolism in muscle
Ferrari, M., Binzoni, T., & Quaresima, V. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0049 · Cited by 247
“In the Eighties several NIR CWS prototypes were built (Jo$ bsis 1977; Giannini et al. 1982; Takada et al. 1987; Cope & Delpy 1988; Chance et al. 1988a, b ; Hampson & Piantadosi 1988); forearm occlusion and exercise was used to test their instrumental capabilities.”
MethodNoninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
“Trends in human skeletal muscle deoxygenation have been studied previously during cuff ischaemia and extreme exercise (Hampson and Piantadosi 1988; Chance et al. 1988, 1992; De Blasi et al. 1992).”
Belardinelli, R., Barstow, T. J., Porszasz, J., & Wasserman, K. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00634377 · Cited by 213
“Reflectance NIRS, such as used here, has been utilized to evaluate tissue oxygenation and function in brain (Jobsis-Vander Vliet 1985) and in resting human skeletal muscle under normal and ischemic conditions (Hampson and Piantadosi 1988).”
MethodWearable Organic Optoelectronic Sensors for Medicine
Bansal, A. K., Hou, S., Kulyk, O., Bowman, E. M., & Samuel, I. D. W. (2015) · Advanced Materials · doi:10.1002/adma.201403560 · Cited by 205
An investigation of light transport through scattering bodies with non-scattering regions
Firbank, M., Arridge, S. R., Schweiger, M., & Delpy, D. T. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/4/012 · Cited by 189
“Near-infra-red (NIR) spectroscopy is currently being widely used to measure changes in the oxygenation of cerebral and other tissues of both neonates and adults (Wyattet al 1986, Edwardset al 1988, Hampson and Piantadosi 1988, Peebleset al 1992, Elwellet al 1993, De Blasiet al 1993).”
Firbank, M., Oda, M., & Delpy, D. T. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/016 · Cited by 181
Davis, S. L., Fadel, P. J., Cui, J., Thomas, G. D., & Crandall, C. G. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2005 · Cited by 179
“In the study by Hampson and Piantadosi (11), NIR-derived tissue oxygenation of a doublefold thickness of skin remained unchanged during forearm ischemia and postischemic reactive hyperemia.”
BackgroundMethodFranceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
“Of these two, the contribution of the skin to the total NIRS signal is quite small: approximately 5% if the source and detector of the NIRS probe are separated by more than 20 mm (Hampson and Piantidosi, 1988).”
BackgroundComparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98
Quantification of ischemic muscle deoxygenation by near infrared time-resolved spectroscopy
Hamaoka, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Sako, T., Higuchi, H., Kurosawa, Y., Shimomitsu, T., Miwa, M., et al. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429975 · Cited by 97
“@HbO2#5~e2 ma 2e2 ma !/~e2 e1 2e2 e1 !, (4)”
Detection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89
Gurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
New Instrument That Uses Near-Infrared Spectroscopy for the Monitoring of Human Muscle Oxygenation
Muellner, T., Nikolic, A., Schramm, W., & Vecsei, V. (1999) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199906000-00021 · Cited by 34
Metadata
- Authors
- Hampson, N. B., & Piantadosi, C. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-06-01
- Volume
- 64
- Issue
- 6
- Pages
- 2449-2457
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2115190434
- Cited by
- 300
- References
- 4
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.