CoChat

A simple and valid method to determine thermoregulatory sweating threshold and sensitivity

Cheuvront, Samuel N., Bearden, Shawn E., Kenefick, Robert W., Ely, Brett R., DeGroot, David W., Sawka, Michael N., Montain, Scott J. · 2009 · Journal of Applied Physiology
Cited by 111

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Sweating threshold temperature and sweating sensitivity responses are measured to evaluate thermoregulatory control. However, analytic approaches vary, and no standardized methodology has been validated. This study validated a simple and standardized method, segmented linear regression (SReg), for determination of sweating threshold temperature and sensitivity. Archived data were extracted for analysis from studies in which local arm sweat rate (ṁ sw; ventilated dew-point temperature sensor) and esophageal temperature (T es) were measured under a variety of conditions. The relationship ṁ sw/T es from 16 experiments was analyzed by seven experienced raters (Rater), using a variety of empirical methods, and compared against SReg for the determination of sweating threshold temperature and sweating sensitivity values. Individual interrater differences ( n = 324 comparisons) and differences between Rater and SReg ( n = 110 comparisons) were evaluated within the context of biologically important limits of magnitude (LOM) via a modified Bland-Altman approach. The average Rater and SReg outputs for threshold temperature and sensitivity were compared ( n = 16) using inferential statistics. Rater employed a very diverse set of criteria to determine the sweating threshold temperature and sweating sensitivity for the 16 data sets, but interrater differences were within the LOM for 95% (threshold) and 73% (sensitivity) of observations, respectively. Differences between mean Rater and SReg were within the LOM 90% (threshold) and 83% (sensitivity) of the time, respectively. Rater and SReg were not different by conventional t-test ( P > 0.05). SReg provides a simple, valid, and standardized way to determine sweating threshold temperature and sweating sensitivity values for thermoregulatory studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00250.2009

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 111

Metadata

Authors
Cheuvront, S. N., Bearden, S. E., Kenefick, R. W., Ely, B. R., DeGroot, D. W., Sawka, M. N., & Montain, S. J.
Venue
Journal of Applied Physiology
Published
2009-07
Volume
107
Issue
1
Pages
69-75
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2146111561
Cited by
111
References
9
FWCI
2.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simple and valid method to determine thermoregulatory sweating threshold and sensitivity. https://app.cochat.ai/papers/10.1152/japplphysiol.00250.2009
The paper
Cheuvront, S. N., Bearden, S. E., Kenefick, R. W., Ely, B. R., DeGroot, D. W., Sawka, M. N., & Montain, S. J. (2009). A simple and valid method to determine thermoregulatory sweating threshold and sensitivity. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00250.2009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.