The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Abstract
The arterial pulse-wave transit time can be measured between the ECG R-wave and the finger pulse ( rPTT), and has been shown previously to have a linear correlation with blood pressure (BP). We hypothesized that the relationship between rPTT, preejection period (PEP; the R-wave/mechanical cardiac delay), and BP would vary with different vasoactive drugs. Twelve healthy men (mean age 22 yr) were studied. Beat-to-beat measurements were made of rPTT (using ECG and photoplethysmograph finger probe), intra-arterial radial pressure, PEP (using cardiac bioimpedance), and transit time minus PEP ( pPTT). Four drugs (glyceryl trinitrate, angiotensin II, norepinephrine, salbutamol) were administered intravenously over 15 min, with stepped dosage increase every 5 min and a 25-min saline washout between agents. All subjects in all conditions had a negative linear correlation ( R 2 = 0.39) between rPTT and systolic BP (SBP), generally constant between different drugs, apart from four subjects who had a positive rPTT/SBP correlation with salbutamol. The 95% limits of agreement between measured and rPTT-predicted SBP were ±17.0 mmHg. Beat-to-beat variability of rPTT showed better coherence with SBP variability than it did with heart rate variability ( P < 0.001). PEP accounted for a substantial and variable proportion of rPTT (12–35%). Diastolic (DBP) and mean arterial BP (MAP) correlated poorly with rPTT ( R 2 = 0.02 and 0.08, respectively) but better with pPTT ( rPTT corrected for PEP, R 2 = 0.41 and 0.45, respectively). The 95% limits of agreement between measured and pPTT-predicted DBP were ± 17.3 mmHg. In conclusion, the negative correlation between rPTT and SBP is generally constant, even with marked hemodynamic perturbations. However, the relationship is not reliable enough for rPTT to be used as a surrogate marker of SBP, although it may be useful in assessing BP variability. DBP and MAP cannot be predicted from rPTT without correction for PEP. The significant contribution of PEP to rPTT means that rPTT should not be used as a marker of purely vascular function.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The results for HR and SpO2 are within the regulatory guidelines set by the US Food and Drug Administration (FDA), which require errors less than ± 10 % or ± 5 bpm for HR and less than 3.5 % for Arms for reflectance mode SpO226,27.”
From Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units (2020) · cites this paper as [27]
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,395
Parati, G., Saul, J. P., Di Rienzo, M., & Mancia, G. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1276 · Cited by 849
Dave, K. A., & White, S. W. (2002) · World Highways/Routes du Monde · Cited by 767
The revision of the Declaration of Helsinki: past, present and future
Carlson, R. V., Boyd, K., & Webb, D. J. (2004) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2004.02103.x · Cited by 723
Self-citationPhotoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 528
Brien, E. O., Petrie, J. C., Little, W. C., de Swiet, M., Padfield, P. L., Altma, D. G., Bland, M., Coats, A. J. S., & Atkins, N. (1993) · Journal of Hypertension · doi:10.1097/00004872-199306000-00013 · Cited by 518
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Lantelme, P., Mestre, C., Lièvre, M. M., Gressard, A., & Milon, H. (2002) · Hypertension · doi:10.1161/01.hyp.0000019132.41066.95 · Cited by 353
Arterial baroreflex function and cardiovascular variability: interactions and implications
Lanfranchi, P. A., & Somers, V. K. (2002) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00051.2002 · Cited by 340
Determination of pulse wave velocities with computerized algorithms
Chiu, Y. C., Arand, P. W., Shroff, S. G., Feldman, T. E., & Carroll, J. D. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90153-9 · Cited by 313
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Silke, B., & McAuley, D. F. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000600 · Cited by 289
Laguna, P., Moody, G. B., & Mark, R. G. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.678605 · Cited by 277
Pulse Wave Velocity as a Measure of Blood Pressure Change
Gribbin, B., Steptoe, A., & Sleight, P. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb03344.x · Cited by 227
The First Derivative Thoracic Impedance Cardiogram
Lababidi, Z. A., Ehmke, D. A., Durnin, R. E., Leaverton, P. E., & Lauer, R. M. (1970) · Circulation · doi:10.1161/01.cir.41.4.651 · Cited by 192
Riva-Rocci, S. (1896) · Medical Entomology and Zoology · Cited by 192
A Transducer for the Continuous External Measurement of Arterial Blood Pressure
Pressman, G. L., & Newgard, P. M. (1963) · IRE Transactions on Bio-Medical Electronics · doi:10.1109/tbmel.1963.4322794 · Cited by 178
Wilkinson, I. B., MacCallum, H., Hupperetz, P. C., van Thoor, C. J., Cockcroft, J., & Webb, D. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0541k.x · Cited by 174
Self-citationPulse Wave Velocity and Blood Pressure Change: Calibration and Applications
Steptoe, A., Smulyan, H., & Gribbin, B. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb00866.x · Cited by 172
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164
The Aging of Elastic and Muscular Arteries
Cameron, J. D., Bulpitt, C. J., Pinto, E., & Rajkumar, C. (2003) · Diabetes Care · doi:10.2337/diacare.26.7.2133 · Cited by 163
陳, 文. (2001) · Medical Entomology and Zoology · Cited by 115
Pulse Transit Time and Blood Pressure: An Intensive Analysis
Lane, J. D., Greenstadt, L., Shapiro, D., & Rubinstein, E. H. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb00899.x · Cited by 107
Thomas, S. H. L. (1992) · PubMed Central · Cited by 80
Measuring blood pressure in pregnant women: A comparison of direct and indirect methods
Brown, M. A., Reiter, L., Smith, B., Buddle, M. L., Morris, R., & Whitworth, J. A. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(94)90079-5 · Cited by 65
Pulse Transit Time in the Analysis of Autonomic Nervous System Effects on the Cardiovascular System
Weiss, T., Bo, A. D., Reichek, N., & Engelman, K. (1980) · Psychophysiology · doi:10.1111/j.1469-8986.1980.tb00136.x · Cited by 62
Ochiai, R., Takeda, J., Hosaka, H., Sugo, Y., Tanaka, R., & Soma, T. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009950731297 · Cited by 58
Zorn, E., Wilson, M., Ángel, J. D., Zanella, & Alpert, B. (1997) · PubMed · Cited by 58
Jiang, X. J., O'Rourke, M. F., Jin, W. Q. L., Liu, L. S., Li, C. W., Tai, P. C., Zhang, X. C., & Liu, S. Z. (2002) · Heart · doi:10.1136/heart.88.2.143 · Cited by 54
Increase in pulse transit time to the foot after epidural anaesthesia treatment
Babchenko, A., Davidson, E. M., Adler, D., Ginosar, Y., Kurz, V., & Nitzan, M. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344874 · Cited by 52
Systolic time intervals in clinical pharmacology
Li, Q., & Belz, G. G. (1993) · European Journal of Clinical Pharmacology · doi:10.1007/bf00315536 · Cited by 43
Gibson, D. G., & Dj, C. (1971) · PubMed · Cited by 37
The effect of age on vascular compliance in man: which are the appropriate measures?
Bulpitt, C. J., Cameron, J. D., Rajkumar, C., Armstrong, S., Connor, M., Joshi, J., Lyons, D. J., Moioli, O., & Nihoyannopoulos, P. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000879 · Cited by 33
Turjanmaa, V. (1989) · Clinical Physiology · doi:10.1111/j.1475-097x.1989.tb00991.x · Cited by 32
An evaluation of a new continuous blood pressure monitoring system in critically ill patients
Heard, S. O., Lisbon, A., Tóth, I., & Ramasubramanian, R. (2000) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(00)00201-4 · Cited by 29
Arterial Pulse Wave Velocity and Heart Rate
Hayward, C. S., Avolio, A. P., & O’Rourke, M. F. (2002) · Hypertension · doi:10.1161/01.hyp.0000038734.25997.a9 · Cited by 24
Ramsay, M., Pipkin, F. B., & Rubin, P. C. (1992) · Clinical Science · doi:10.1042/cs0820157 · Cited by 24
Kerkkamp, H. J. J., & Heethaar, R. M. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb09462.x · Cited by 16
CARDIOVASCULAR EFFECTS OF INTRAVENOUS SALBUTAMOL AFTER OPEN HEART OPERATIONS
Yacoub, M. H., & Boyland, E. (1973) · The Lancet · doi:10.1016/s0140-6736(73)90583-7 · Cited by 11
Haemodynamic responses to glyceryl trinitrate: influence of rate and duration of delivery
Hargreaves, A. D., & Muir, A. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060300 · Cited by 5
Flagged first, then by citations
1 of the 41 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Knowing your own heart: Distinguishing interoceptive accuracy from interoceptive awareness
Garfinkel, S. N., Seth, A. K., Barrett, A. B., Suzuki, K., & Critchley, H. D. (2015) · Biological Psychology · doi:10.1016/j.biopsycho.2014.11.004 · Cited by 1,624
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“1), healthy human [98], and inpatient [134], respectively.”
BackgroundMethodInfluentialUnobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G., Zhao, N., & Zhang, Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 725
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Metadata
- Authors
- Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J.
- Affiliations
- Western General Hospital (GB)
- University of Edinburgh (GB)
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-01
- Volume
- 100
- Issue
- 1
- Pages
- 136-141
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2059208589
- Cited by
- 418
- References
- 41
- Citations by year
- 2026: 12 · 2025: 17 · 2024: 15 · 2023: 18 · 2022: 16 · 2021: 25 · 2020: 39 · 2019: 32 · 2018: 40 · 2017: 28 · 2016: 31 · 2015: 18 · 2014: 19 · 2013: 13 · 2012: 16
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Explore Bristol Research (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- pulse transit time, beat-to-beat blood pressure, pre-ejection period, systolic blood pressure, diastolic blood pressure, mean arterial pressure, vasoactive drugs, nitroglycerin, angiotensin II, norepinephrine, salbutamol, photoplethysmography, blood pressure variability, heart rate variability
- MeSH terms
- Adolescent, Adult, Blood Pressure, Blood Pressure Determination, Diagnosis, Computer-Assisted, Electrocardiography, Heart Rate, Humans, Male, Manometry, Pulsatile Flow, Sensitivity and Specificity, Reproducibility of Results, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review