CoChat

Error, rather than its probability, elicits specific electrocortical signatures: a combined EEG-immersive virtual reality study of action observation

Open access
Pezzetta, Rachele, Nicolardi, Valentina, Tidoni, Emmanuele, Aglioti, Salvatore Maria · 2018 · Journal of Neurophysiology
Cited by 81

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Detecting errors in one’s own actions, and in the actions of others, is a crucial ability for adaptable and flexible behavior. Studies show that specific EEG signatures underpin the monitoring of observed erroneous actions (error-related negativity, error positivity, mid-frontal theta oscillations). However, the majority of studies on action observation used sequences of trials where erroneous actions were less frequent than correct actions. Therefore, it was not possible to disentangle whether the activation of the performance monitoring system was due to an error, as a violation of the intended goal, or to a surprise/novelty effect, associated with a rare and unexpected event. Combining EEG and immersive virtual reality (IVR-CAVE system), we recorded the neural signal of 25 young adults who observed, in first-person perspective, simple reach-to-grasp actions performed by an avatar aiming for a glass. Importantly, the proportion of erroneous actions was higher than correct actions. Results showed that the observation of erroneous actions elicits the typical electrocortical signatures of error monitoring, and therefore the violation of the action goal is still perceived as a salient event. The observation of correct actions elicited stronger alpha suppression. This confirmed the role of the alpha-frequency band in the general orienting response to novel and infrequent stimuli. Our data provide novel evidence that an observed goal error (the action slip) triggers the activity of the performance-monitoring system even when erroneous actions, which are, typically, relevant events, occur more often than correct actions and thus are not salient because of their rarity. NEW & NOTEWORTHY Activation of the performance-monitoring system (PMS) is typically investigated when errors in a sequence are comparatively rare. However, whether the PMS is activated by errors per se or by their infrequency is not known. Combining EEG-virtual reality techniques, we found that observing frequent (70%) action errors performed by avatars elicits electrocortical error signatures suggesting that deviation from the prediction of how learned actions should correctly deploy, rather than its frequency, is coded in the PMS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.00130.2018

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
Pezzetta, R., Nicolardi, V., Tidoni, E., & Aglioti, S. M.
Venue
Journal of Neurophysiology
Published
2018-09-01
Volume
120
Issue
3
Pages
1107-1118
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2805507770
Cited by
81
References
34
FWCI
11.60
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.