Upper threshold of extracellular neural stimulation
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
It is well known that spiking neurons can produce action potentials in response to extracellular stimulation above certain threshold. It is widely assumed that there is no upper limit to somatic stimulation, except for cellular or electrode damage. Here we demonstrate that there is an upper stimulation threshold, above which no action potential can be elicited, and it is below the threshold of cellular damage. Existence of this upper stimulation threshold was confirmed in retinal ganglion cells (RGCs) at pulse durations ranging from 5 to 500 μs. The ratio of the upper to lower stimulation thresholds varied typically from 1.7 to 7.6, depending on pulse duration. Computational modeling of extracellular RGC stimulation explained the upper limit by sodium current reversal on the depolarized side of the cell membrane. This was further confirmed by experiments in the medium with a low concentration of sodium. The limited width of the stimulation window may have important implications in design of the electro-neural interfaces, including neural prosthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
Translational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853 · cited 1×
“1995), in deep brain stimulation (Kern and Kumar 2005; Kringelbach et al. 2007; Mayberg et al. 2005; Perlmutter and Mink 2006) as treatment for Parkinson’s disease (Breit et al.”
BackgroundSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 1×
“EXTRACELLULAR NEURAL STIMULATION is used in retinal (Palanker et al. 2005; Rizzo and Wyatt 1997; Weiland et al. 2005; Zrenner et al. 2011) and cochlear prostheses (House and Urban 1973; Spelman 1999; Zierhofer et al.”
MethodCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 3×
“In the histological studies of the cortical tissue damage by prolonged electrical stimulation (McCreery et al. 1990), no damage was observed during stimulation with the charge of 100 nC per phase, even when the charge density was 1 mC/cm(2).”
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · cited 1×
“This difference between the lower stimulation thresholds for cathodic and anodic pulses has been observed experimentally in epiretinal stimulation (Jensen et al. 2005; Sekirnjak et al. 2006).”
BackgroundSputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138 · cited 1×
“One of the popular electrode materials, sputtered iridium oxide (SIROF), can deliver up to 5 mC/cm 2 via an electrode of 30 m in diameter, with the use of 0.5-ms pulses (Cogan et al. 2004 ).”
MethodInfluentialTissue Damage by Pulsed Electrical Stimulation
Butterwick, A., Vankov, A., Huie, P., Freyvert, Y., & Palanker, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908310 · Cited by 136
Self-citation
Cited by
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
“Keywords: epiretinal, subretinal, intraretinal stimulation, retinal prostheses, stimulation selectivity S Online supplementary data available from stacks.iop.org/JNE/11/026008/mmedia (Some figures may appear in colour only in the online journal)”
BackgroundResultStimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Guo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43
Metadata
- Authors
- Boinagrov, D., Pangratz-Fuehrer, S., Suh, B., Mathieson, K., Naik, N., & Palanker, D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2012-12-15
- Volume
- 108
- Issue
- 12
- Pages
- 3233-3238
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2053074068
- Cited by
- 39
- References
- 8
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.