Ultrasound as a Tool to Assess Body Fat
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Ultrasound has been used effectively to assess body fat for nearly 5 decades, yet this method is not known as well as many other body composition techniques. The purpose of this review is to explain the technical principles of the ultrasound method, explain the procedures for taking a measurement and interpreting the results, evaluate the reliability and validity of this method for measuring subcutaneous and visceral adipose tissue, highlight the advantages and limitations of ultrasound relative to other body composition methods, consider its utility to clinical populations, and introduce new body composition-specific ultrasound technology. The focus of this review is adipose, although various tissue thicknesses (e.g., muscle and bone) can be measured with ultrasound. Being a portable imaging device that is capable of making fast regional estimates of body composition, ultrasound is an attractive assessment tool in instances when other methods are limited. Furthermore, much of the research suggests that it is reliable, reproducible, and accurate. The biggest limitations appear to be a lack of standardization for the measurement technique and results that are highly dependent on operator proficiency. New ultrasound devices and accompanying software designed specifically for the purpose of body composition assessment might help to minimize these limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
Practical Assessment of Body Composition
Jackson, A. S., & Pollock, M. L. (1985) · The Physician and Sportsmedicine · doi:10.1080/00913847.1985.11708790 · Cited by 1,149
Shuster, A., Patlas, M., Pinthus, J. H., & Mourtzakis, M. (2012) · The British Journal of Radiology · doi:10.1259/bjr/38447238 · Cited by 918
Human Body Composition: In Vivo Methods
Ellis, K. J. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.649 · Cited by 825
Assessment methods in human body composition
Lee, S. Y., & Gallagher, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e32830b5f23 · Cited by 694 · cited 1×
“…and validity of this method for measuring subcutaneous and visceral adipose tissue, highlight the advantages and limitations of ultrasound relative to other body composition methods, consider its utility to clinical populations, and introduce new body composition-specific ultrasound technology.”
Applied body composition assessment
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0910 · Cited by 671
Ackland, T. R., Lohman, T. G., Sundgot-Borgen, J., Maughan, R. J., Meyer, N. L., Stewart, A. D., & Müller, W. (2012) · Sports Medicine · doi:10.2165/11597140-000000000-00000 · Cited by 599 · cited 1×
“In a recent review of body composition assessment for athletes, ultrasound was classified as a laboratory method [50].”
BackgroundHuman Body Composition: Advances in Models and Methods
B. Heymsfield, S., Wang, Z., Baumgartner, R. N., & Ross, R. (1997) · Annual Review of Nutrition · doi:10.1146/annurev.nutr.17.1.527 · Cited by 527 · cited 1×
“…and validity of this method for measuring subcutaneous and visceral adipose tissue, highlight the advantages and limitations of ultrasound relative to other body composition methods, consider its utility to clinical populations, and introduce new body composition-specific ultrasound technology.”
Estimation of body fat in young women
Sloan, A. W., Burt, J. J., & Blyth, C. S. (1962) · Journal of Applied Physiology · doi:10.1152/jappl.1962.17.6.967 · Cited by 396
High Visceral and Low Abdominal Subcutaneous Fat Stores in the Obese Adolescent
Taksali, S. E., Caprio, S., Dziura, J., Dufour, S., Calí, A. M. G., Goodman, T. R., Papademetris, X., Burgert, T. S., Pierpont, B. M., Savoye, M., et al. (2008) · Diabetes · doi:10.2337/db07-0932 · Cited by 353
Cited by
Obesity and Cancer: A Current Overview of Epidemiology, Pathogenesis, Outcomes, and Management
Pati, S., Irfan, W., Jameel, A., Ahmed, S., & Shahid, R. K. (2023) · Cancers · doi:10.3390/cancers15020485 · Cited by 677
Lean Tissue Imaging: A New Era for Nutritional Assessment and Intervention
Prado, C. M. M., & Heymsfield, S. B. (2014) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607114550189 · Cited by 550
Measurement of muscle mass in sarcopenia: from imaging to biochemical markers
Tosato, M., Marzetti, E., Cesari, M., Savera, G., Miller, R. R., Bernabei, R., Landi, F., & Calvani, R. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0717-0 · Cited by 320
International society of sports nutrition position stand: diets and body composition
Aragon, A. A., Schoenfeld, B. J., Wildman, R., Kleiner, S., VanDusseldorp, T., Taylor, L., Earnest, C. P., Arciero, P. J., Wilborn, C., Kalman, D. S., et al. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-017-0174-y · Cited by 301
Contemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Heterogeneity of white adipose tissue: molecular basis and clinical implications
Kwok, K. H. M., Lam, K. S. L., & Xu, A. (2016) · Experimental & Molecular Medicine · doi:10.1038/emm.2016.5 · Cited by 252
Body composition in clinical practice
Andreoli, A., Garaci, F., Cafarelli, F. P., & Guglielmi, G. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.02.005 · Cited by 216
Kasper, A. M., Langan-Evans, C., Hudson, J. F., Brownlee, T. E., Harper, L. D., Naughton, R. J., Morton, J. P., & Close, G. L. (2021) · Nutrients · doi:10.3390/nu13041075 · Cited by 196
“, FM content increases the time required for sound reflections off BMC to return to the probe [40]).”
BackgroundSheean, P., Gonzalez, M. C., Prado, C. M., McKeever, L., Hall, A. M., & Braunschweig, C. A. (2020) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.1669 · Cited by 164
The pathophysiology of abdominal adipose tissue depots in health and disease
Walker, G. E., Marzullo, P., Ricotti, R., Bona, G., & Prodam, F. (2014) · Hormone Molecular Biology and Clinical Investigation · doi:10.1515/hmbci-2014-0023 · Cited by 90
“In addition to these methods, studies to validate ultrasound techniques in the measuring of SAT and VAT in the abdomen and for muscle thickness are ongoing [37].”
MethodMeasuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
“Using an ultrasound with a lower frequency can solve this problem, as the penetration increases, however this will decrease the resolution of the image [60].”
BackgroundSmith, S., & Madden, A. M. (2016) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12372 · Cited by 67
Henriques, H. K. F., Kattah, F. M., Piccolo, M. S., dos Santos, E. A., de Araújo Ventura, L. H., Cerqueira, F. R., Vieira, C. M. A. F., & Leite, J. I. A. (2025) · Obesities · doi:10.3390/obesities5020042 · Cited by 4
Metadata
- Authors
- Wagner, D. R.
- Venue
- Journal of Obesity
- Publisher
- Wiley
- Published
- 2013
- Volume
- 2013
- Pages
- 1-9
- ISSN
- 2090-0708 (ISSN-L)
- 2090-0716
- OpenAlex
- W2039527359
- Cited by
- 252
- References
- 59
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.