Electrochemical Sensor for Multiplex Biomarkers Detection
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Purpose: Multiplexing assay of biomarkers at the point-of-care is an elusive goal for molecular diagnostics. Experimental Design: Here, we report an electrochemical (EC) sensor for oral cancer detection based on the simultaneous detection of two salivary biomarkers: interleukin (IL)-8 mRNA and IL-8 protein. Results: Under the multiplexing mode, the limit of detection of salivary IL-8 mRNA reaches to 3.9 fM and 7.4 pg/mL for IL-8 protein in saliva. Multiplex assay of these 2 biomarkers directly from 28 cancer and 28 matched control saliva samples shows significant difference between the two groups. From the receiver operating characteristic analysis, the EC sensor yields around 90% sensitivity and specificity for both IL-8 mRNA and IL-8 protein, which are very close to the data measured by traditional assays (ELISA and PCR) with the same group of saliva. Combined IL-8 mRNA and protein show better AUC compared with single biomarker. Conclusions: We show, for the first time, concurrently multiplexing detection of salivary mRNA and protein biomarkers using point-of-care EC sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Salivary Transcriptome Diagnostics for Oral Cancer Detection
Li, Y., St. John, M. A. R., Zhou, X., Kim, Y., Sinha, U., Jordan, R. C. K., Eisele, D., Abemayor, E., Elashoff, D., Park, N.-H., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1167 · Cited by 625
Self-citationAn Enzyme-Based E-DNA Sensor for Sequence-Specific Detection of Femtomolar DNA Targets
Liu, G., Wan, Y., Gau, V., Zhang, J., Wang, L., Song, S., & Fan, C. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800554t · Cited by 418
Microfluidic immunoassays as rapid saliva-based clinical diagnostics
Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607254104 · Cited by 389
Salivary proteomic and genomic biomarkers for primary Sjögren's syndrome
Hu, S., Wang, J., Meijer, J., Ieong, S., Xie, Y., Yu, T., Zhou, H., Henry, S., Vissink, A., Pijpe, J., et al. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22954 · Cited by 366
Self-citationSalivary biomarkers of existing periodontal disease
Miller, C. S., King, C. P., Langub, M. C., Kryscio, R. J., & Thomas, M. V. (2006) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2006.0181 · Cited by 360
Proteomics for cancer biomarker discovery.
Srinivas, P. R., Verma, M., Zhao, Y., & Srivastava, S. (2002) · PubMed · Cited by 323
Characterization of serum biomarkers for detection of early stage ovarian cancer
Kozak, K. R., Su, F., Whitelegge, J. P., Faull, K., Reddy, S., & Farias‐Eisner, R. (2005) · PROTEOMICS · doi:10.1002/pmic.200500093 · Cited by 311
Sample Size Determination for Some Common Nonparametric Tests
Noether, G. E. (1987) · Journal of the American Statistical Association · doi:10.1080/01621459.1987.10478478 · Cited by 307
Mandel, I. D. (1990) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1990.tb00809.x · Cited by 305 · cited 4×
“Early diagnosis is an important factor to enhance effectiveness of treatment (1, 2 ). The analysis of body fluids offers possibility to shift the detection of cancer to an earlier stage.”
BackgroundInfluentialXiao, Y., Qu, X., Plaxco, K. W., & Heeger, A. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja074218y · Cited by 259
Behnisch, P. A., Hosoe, K., & Sakai, S.-I. (2001) · Environment International · doi:10.1016/s0160-4120(01)00028-9 · Cited by 254
Sample Size Determination for Some Common Nonparametric Tests
Noether, G. E. (1987) · Journal of the American Statistical Association · doi:10.2307/2289477 · Cited by 225
Characterization of RNA in Saliva
Park, N. J., Li, Y., Yu, T., Brinkman, B. M., & Wong, D. T. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063206 · Cited by 212
Self-citationLiao, J. C., Mastali, M., Gau, V., Suchard, M. A., Møller, A. K., Bruckner, D. A., Babbitt, J. T., Li, Y., Gornbein, J., Landaw, E. M., et al. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.44.2.561-570.2006 · Cited by 211
A MEMS based amperometric detector for E. Coli bacteria using self-assembled monolayers
Gau, J.-J., Lan, E. H., Dunn, B., Ho, C., & Woo, J. C. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00216-0 · Cited by 207
Self-citationGormally, E., Vineis, P., Matullo, G., Veglia, F., Caboux, E., Le Roux, E., Peluso, M., Garte, S., Guarrera, S., Munnia, A., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-4556 · Cited by 164
Human Saliva Proteome Analysis
Hu, S., Loo, J. A., & Wong, D. T. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.015 · Cited by 159
Self-citationMultiplexed immunobead‐based assay for detection of oral cancer protein biomarkers in saliva
Arellano‐Garcia, M., Hu, S., Wang, J., Henson, B., Zhou, H., Chia, D., & Wong, D. (2008) · Oral Diseases · doi:10.1111/j.1601-0825.2008.01488.x · Cited by 156
Self-citationElectrochemical molecular analysis without nucleic acid amplification
Gau, V., Ma, S., Wang, H., Tsukuda, J., Kibler, J. L., & Haake, D. A. (2005) · Methods · doi:10.1016/j.ymeth.2005.05.008 · Cited by 130
Pulse technique for the electrochemical deposition of polymer films on electrode surfaces
Schuhmann, W. W., Kranz, C., Wohlschläger, H., & Strohmeier, J. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00086-9 · Cited by 127
Zimmermann, B. G., Park, N. J., & Wong, D. T. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.002 · Cited by 118
Self-citationΟικονομοπούλου, Κ., Li, L., Zheng, Y., Simón, I., Wolfert, R. L., Valík, D., Nekulová, M., Simickova, M., Frgala, T., & Diamandis, E. P. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604630 · Cited by 105
Salivary Diagnosis: More than a Lick and a Promise
Mandel, I. D. (1993) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1993.0007 · Cited by 103
Wei, F., Liao, W., Xu, Z., Yang, Y., Wong, D. T., & Ho, C. (2009) · Small · doi:10.1002/smll.200900369 · Cited by 96
Self-citationFang, W., Wang, J., Liao, W., Zimmermann, B. G., Wong, D. T., & Ho, C. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn299 · Cited by 89
Self-citationExon-Level Expression Profiling: A Comprehensive Transcriptome Analysis of Oral Fluids
Hu, Z., Zimmermann, B. G., Zhou, H., Wang, J., Henson, B. S., Yu, W., Elashoff, D. A., Krupp, G., & Wong, D. T. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096164 · Cited by 73
Self-citation
Cited by
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Wang, S., Zhang, L., Wan, S., Cansiz, S., Cui, C., Liu, Y., Cai, R., Hong, C., Teng, I.-T., Shi, M., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00373 · Cited by 476
Self-citationIntegrated Magneto–Electrochemical Sensor for Exosome Analysis
Jeong, S., Park, J., Pathania, D., Castro, C. M., Weissleder, R., & Lee, H. (2016) · ACS Nano · doi:10.1021/acsnano.5b07584 · Cited by 469
Metadata
- Authors
- Wei, F., Patel, P., Liao, W., Chaudhry, K., Zhang, L., Arellano-Garcia, M., Hu, S., Elashoff, D., Zhou, H., Shukla, S., Shah, F., Ho, C.-M., & Wong, D. T.
- Venue
- Clinical Cancer Research
- Published
- 2009-07-01
- Volume
- 15
- Issue
- 13
- Pages
- 4446-4452
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2127043135
- Cited by
- 257
- References
- 27
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.