Electrochemical Sensor for Multiplex Biomarkers Detection
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Purpose: Multiplexing assay of biomarkers at the point-of-care is an elusive goal for molecular diagnostics. Experimental Design: Here, we report an electrochemical (EC) sensor for oral cancer detection based on the simultaneous detection of two salivary biomarkers: interleukin (IL)-8 mRNA and IL-8 protein. Results: Under the multiplexing mode, the limit of detection of salivary IL-8 mRNA reaches to 3.9 fM and 7.4 pg/mL for IL-8 protein in saliva. Multiplex assay of these 2 biomarkers directly from 28 cancer and 28 matched control saliva samples shows significant difference between the two groups. From the receiver operating characteristic analysis, the EC sensor yields around 90% sensitivity and specificity for both IL-8 mRNA and IL-8 protein, which are very close to the data measured by traditional assays (ELISA and PCR) with the same group of saliva. Combined IL-8 mRNA and protein show better AUC compared with single biomarker. Conclusions: We show, for the first time, concurrently multiplexing detection of salivary mRNA and protein biomarkers using point-of-care EC sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Salivary Transcriptome Diagnostics for Oral Cancer Detection
Li, Y., St. John, M. A. R., Zhou, X., Kim, Y., Sinha, U., Jordan, R. C. K., Eisele, D., Abemayor, E., Elashoff, D., Park, N.-H., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1167 · Cited by 625
Self-citationAn Enzyme-Based E-DNA Sensor for Sequence-Specific Detection of Femtomolar DNA Targets
Liu, G., Wan, Y., Gau, V., Zhang, J., Wang, L., Song, S., & Fan, C. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800554t · Cited by 418
Microfluidic immunoassays as rapid saliva-based clinical diagnostics
Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607254104 · Cited by 389
Salivary proteomic and genomic biomarkers for primary Sjögren's syndrome
Hu, S., Wang, J., Meijer, J., Ieong, S., Xie, Y., Yu, T., Zhou, H., Henry, S., Vissink, A., Pijpe, J., et al. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22954 · Cited by 366
Self-citationSalivary biomarkers of existing periodontal disease
Miller, C. S., King, C. P., Langub, M. C., Kryscio, R. J., & Thomas, M. V. (2006) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2006.0181 · Cited by 360
Proteomics for cancer biomarker discovery.
Srinivas, P. R., Verma, M., Zhao, Y., & Srivastava, S. (2002) · PubMed · Cited by 323
Characterization of serum biomarkers for detection of early stage ovarian cancer
Kozak, K. R., Su, F., Whitelegge, J. P., Faull, K., Reddy, S., & Farias‐Eisner, R. (2005) · PROTEOMICS · doi:10.1002/pmic.200500093 · Cited by 311
Sample Size Determination for Some Common Nonparametric Tests
Noether, G. E. (1987) · Journal of the American Statistical Association · doi:10.1080/01621459.1987.10478478 · Cited by 307
Mandel, I. D. (1990) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1990.tb00809.x · Cited by 305 · cited 4×
“Early diagnosis is an important factor to enhance effectiveness of treatment (1, 2 ). The analysis of body fluids offers possibility to shift the detection of cancer to an earlier stage.”
BackgroundInfluential
Cited by
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Wang, S., Zhang, L., Wan, S., Cansiz, S., Cui, C., Liu, Y., Cai, R., Hong, C., Teng, I.-T., Shi, M., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00373 · Cited by 476
Self-citationIntegrated Magneto–Electrochemical Sensor for Exosome Analysis
Jeong, S., Park, J., Pathania, D., Castro, C. M., Weissleder, R., & Lee, H. (2016) · ACS Nano · doi:10.1021/acsnano.5b07584 · Cited by 469
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Saliva: diagnostics and therapeutic perspectives
Spielmann, N., & Wong, D. (2011) · Oral Diseases · doi:10.1111/j.1601-0825.2010.01773.x · Cited by 378
Self-citationHandheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Screen-printed electrodes: Transitioning the laboratory in-to-the field
García-Miranda Ferrari, A., Rowley-Neale, S. J., & Banks, C. E. (2021) · Talanta Open · doi:10.1016/j.talo.2021.100032 · Cited by 315
Carbon black as an outstanding and affordable nanomaterial for electrochemical (bio)sensor design
Arduini, F., Cinti, S., Mazzaracchio, V., Scognamiglio, V., Amine, A., & Moscone, D. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112033 · Cited by 298
Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics
Malon, R. S. P., Sadir, S., Balakrishnan, M., & Córcoles, E. P. (2014) · BioMed Research International · doi:10.1155/2014/962903 · Cited by 260
“[160].”
Role of Pancreatic Cancer-derived Exosomes in Salivary Biomarker Development
Lau, C., Kim, Y., Chia, D., Spielmann, N., Eibl, G., Elashoff, D., Wei, F., Lin, Y.-L., Moro, A., Grogan, T., et al. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.452458 · Cited by 256
“) controlled the electrical field applied to the 16 array sensors and simultaneously recorded the amperometric current (29, 30).”
MethodSelf-citationGholizadeh, S., Shehata Draz, M., Zarghooni, M., Sanati-Nezhad, A., Ghavami, S., Shafiee, H., & Akbari, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.062 · Cited by 229
Sardesai, N. P., Barron, J. C., & Rusling, J. F. (2011) · Analytical Chemistry · doi:10.1021/ac201292q · Cited by 222
Chikkaveeraiah, B. V., Mani, V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.005 · Cited by 220
“They measured oral cancer protein biomarker interleukin (IL)-8 and IL-8 mRNA in saliva with DL of ~4 fM for IL-8 mRNA and 7 pg mL−1 for IL-8 (Wei et al., 2009).”
BackgroundMethodRole of Saliva and Salivary Diagnostics in the Advancement of Oral Health
Dawes, C., & Wong, D. T. W. (2019) · Journal of Dental Research · doi:10.1177/0022034518816961 · Cited by 218
Self-citationMalhotra, R., Patel, V., Chikkaveeraiah, B. V., Munge, B. S., Cheong, S. C., Zain, R. B., Abraham, M. T., Dey, D. K., Gutkind, J. S., & Rusling, J. F. (2012) · Analytical Chemistry · doi:10.1021/ac301392g · Cited by 207
Salivary Biomarkers for Detection of Systemic Diseases
Rathnayake, N., Åkerman, S., Klinge, B., Lundegren, N., Jansson, H., Tryselius, Y., Sorsa, T., & Gustafsson, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061356 · Cited by 192
“Our finding is in line with a study performed by Wei and coauthors that investigated salivary IL-8 levels of patients with oral cancer [33].”
ResultSalivary biomarker development using genomic, proteomic and metabolomic approaches
Bonne, N. J., & Wong, D. T. (2012) · Genome Medicine · doi:10.1186/gm383 · Cited by 178
Self-citationBiomarkers and biosensors for the early diagnosis of lung cancer
Altintas, Z., & Tothill, I. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.07.078 · Cited by 173
Munge, B. S., Coffey, A. L., Doucette, J. M., Somba, B. K., Malhotra, R., Patel, V., Gutkind, J. S., & Rusling, J. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201102941 · Cited by 171
Lab-on-a-Disc for Fully Integrated Multiplex Immunoassays
Park, J., Sunkara, V., Kim, T.-H., Hwang, H., & Cho, Y.-K. (2012) · Analytical Chemistry · doi:10.1021/ac203163u · Cited by 164
Development of transcriptomic biomarker signature in human saliva to detect lung cancer
Zhang, L., Xiao, H., Zhou, H., Santiago, S., Lee, J. M., Garon, E. B., Yang, J., Brinkmann, O., Yan, X., Akin, D., et al. (2012) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-012-1027-0 · Cited by 162
“Salivary proteomic and genomic biomarkers have been successfully developed by our team for the detection of oral squamous cell carcinoma [20, 21, 23], Sjögren’s syndrome [24], pancreatic cancer [15], and breast cancer [25].”
BackgroundSelf-citationSalivary Biomarkers for Detection of Oral Squamous Cell Carcinoma: Current State and Recent Advances
Yakob, M., Fuentes, L., Wang, M. B., Abemayor, E., & Wong, D. T. W. (2014) · Current Oral Health Reports · doi:10.1007/s40496-014-0014-y · Cited by 148
Self-citationDong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Electrochemical bioaffinity sensors for salivary biomarkers detection
Campuzano, S., Yánez-Sedeño, P., & Pingarrón, J. M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.10.002 · Cited by 81
Metadata
- Authors
- Wei, F., Patel, P., Liao, W., Chaudhry, K., Zhang, L., Arellano-Garcia, M., Hu, S., Elashoff, D., Zhou, H., Shukla, S., Shah, F., Ho, C.-M., & Wong, D. T.
- Venue
- Clinical Cancer Research
- Published
- 2009-07-01
- Volume
- 15
- Issue
- 13
- Pages
- 4446-4452
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2127043135
- Cited by
- 257
- References
- 27
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.