Measurement of Optical Path Length for Cerebral Near-Infrared Spectroscopy in Newborn Infants
The DOI matches its Crossref record.
Abstract
The time taken for an extremely short pulse of near-infrared laser light to traverse the heads of 6 preterm infants was measured after death. The values obtained were used to calculate a differential path length factor (DPF), defined as the mean distance travelled by the photons divided by the distance between the points where light entered and left the head. The DPF was found to be 4.39 +/- 0.28. Knowledge of this factor will permit accurate quantitative measurements to be made by near-infrared spectroscopy of a range of indices of cerebral oxygenation and haemodynamics in live infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“The DPF value was first measured on the head of preterm infants after death (Wyatt et al., 1990), and later on: 1) living newborn infants and adults (van der Zee et al., 1992), and 2) adults during hypoxic hypoxia (Ferrari et al., 1993).”
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Self-citationProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Self-citationTsuji, M., Saul, J. P., du Plessis, A., Eichenwald, E., Sobh, J., Crocker, R., & Volpe, J. J. (2000) · Pediatrics · doi:10.1542/peds.106.4.625 · Cited by 571
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Self-citationTime domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
Self-citationvan der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Self-citationNear-infrared spectroscopy: A report from the McDonnell infant methodology consortium
Gervain, J., Mehler, J., Werker, J. F., Nelson, C. A., Csibra, G., Lloyd-Fox, S., Shukla, M., & Aslin, R. N. (2011) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2010.07.004 · Cited by 363
Measurement of the optical properties of the skull in the wavelength range 650-950 nm
Firbank, M., Hiraoka, M., Essenpreis, M., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/4/002 · Cited by 305
Self-citationNear‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Effects of indomethacin on cerebral haemodynamics in very preterm infants
Edwards, A. D., Wyatt, J. S., Richardson, C., Potter, A., Reynolds, E. O. R., Cope, M., & Delpy, D. T. (1990) · The Lancet · doi:10.1016/0140-6736(90)93030-s · Cited by 296
Self-citationFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Near-Infrared spectroscopy: Theory and applications
Wahr, J. A., Tremper, K. K., Samra, S., & Delpy, D. T. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(96)80107-8 · Cited by 227
Self-citationMosca, F., Bray, M., Lattanzio, M., Fumagalli, M., & Tosetto, C. (1997) · The Journal of Pediatrics · doi:10.1016/s0022-3476(97)70060-x · Cited by 211
Spectral dependence of temporal point spread functions in human tissues
Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T. (1993) · Applied Optics · doi:10.1364/ao.32.000418 · Cited by 195
Self-citationFrequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory
Pogue, B. W., & Patterson, M. S. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/7/008 · Cited by 184
Cerebral Oxygenation during Pediatric Cardiac Surgery Using Deep Hypothermic Circulatory Arrest
Kurth, D. C., Steven, J. M., & Nicolson, S. C. (1995) · Anesthesiology · doi:10.1097/00000542-199501000-00011 · Cited by 172
Skov, L., Pryds, O., & Greisen, G. (1991) · Pediatric Research · doi:10.1203/00006450-199112000-00016 · Cited by 168
A Comparison of the INVOS 4100 and the NIRO 300 Near-Infrared Spectrophotometers
Yoshitani, K., Kawaguchi, M., Tatsumi, K., Kitaguchi, K., & Furuya, H. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00020 · Cited by 162
Metadata
- Authors
- Wyatt, J. S., Cope, M., Delpy, D. T., van der Zee, P., Arridge, S., Edwards, A. D., & Reynolds, E. O. R.
- Venue
- Developmental Neuroscience
- Publisher
- S. Karger AG
- Published
- 1990
- Volume
- 12
- Issue
- 2
- Pages
- 140-144
- ISSN
- 0378-5866 (ISSN-L)
- 1421-9859
- OpenAlex
- W2057377618
- Cited by
- 182
- References
- 0
- FWCI
- 11.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.