A Progress Report of the IFCC Committee for Standardization of Thyroid Function Tests
Open accessThe DOI matches its Crossref record; 32 of the 34 references it cites were found in a registry or an index.
Abstract
Background: The IFCC Committee for Standardization of Thyroid Function Tests aims at equivalence of laboratory test results for free thyroxine (FT4) and thyrotropin (TSH). Objectives: This report describes the phase III method comparison study with clinical samples representing a broad spectrum of thyroid disease. The objective was to expand the feasibility work and explore the impact of standardization/harmonization in the clinically relevant concentration range. Methods: Two sets of serum samples (74 for FT4, 94 for TSH) were obtained in a clinical setting. Eight manufacturers participated in the study (with 13 FT4 and 14 TSH assays). Targets for FT4 were set by the international conventional reference measurement procedure of the IFCC; those for TSH were based on the all-procedure trimmed mean. The manufacturers recalibrated their assays against these targets. Results: All FT4 assays were negatively biased in the mid- to high concentration range, with a maximum interassay discrepancy of approximately 30%. However, in the low range, the maximum deviation was approximately 90%. For TSH, interassay comparability was reasonable in the mid-concentration range, but worse in the pathophysiological ranges. Recalibration was able to eliminate the interassay differences, so that the remaining dispersion of the data was nearly entirely due to within-assay random error components. The impact of recalibration on the numerical results was particularly high for FT4. Conclusions: Standardization and harmonization of FT4 and TSH measurements is feasible from a technical point of view. Because of the impact on the numerical values, the implementation needs careful preparation with the stakeholders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Current immunoassays appear to be less affected by glycosylation changes in TSH, which occur in pituitary disease.22,104”
From Thyroid Stimulating Hormone and Thyroid Hormones (Triiodothyronine and Thyroxine): An American Thyroid Association-Commissioned Review of Current Clinical and Laboratory Status (2023) · cites this paper as [104]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Alternatively, the state-of-the-art APS can be derived from the evaluation and comparison of laboratory methods99–104 or using peer comparison data from proficiency testing programs.105–107”
From Thyroid Stimulating Hormone and Thyroid Hormones (Triiodothyronine and Thyroxine): An American Thyroid Association-Commissioned Review of Current Clinical and Laboratory Status (2023) · cites this paper as [104]
Experimental — accuracy not yet measuredIn the citing paper
“In addition, the overall excellent correlation of most of the immunoassays' results to the APTM in patients with both hypo- and hyperthyroidism led the committee to conclude that the assays measured TSH in an equimolar fashion, regardless of differences in glycosylation (31).”
From Harmonization of Serum Thyroid-Stimulating Hormone Measurements Paves the Way for the Adoption of a More Uniform Reference Interval (2017) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De Groot, L., Abalovich, M., Alexander, E. K., Amino, N., Barbour, L., Cobin, R. H., Eastman, C. J., Lazarus, J. H., Luton, D., Mandel, S. J., et al. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-2803 · Cited by 1,866
Mittal, M., Kumar, A., Ramji, S., Narula, S., & Thirupuram, S. (1990) · PubMed · Cited by 1,764
Garber, J. R., Cobin, R. H., Gharib, H., Hennessey, J. V., Klein, I., Mechanick, J. I., Pessah-Pollack, R., Singer, P. A., & Woeber, K. A. (2012) · Endocrine Practice · doi:10.4158/ep12280.gl · Cited by 1,567
Myers, G. L. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.0525144 · Cited by 1,232
Laboratory Support for the Diagnosis and Monitoring of Thyroid Disease
(2003) · Thyroid · doi:10.1089/105072503321086962 · Cited by 1,212
Demers, L. M., & Spencer, C. A. (2003) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01681.x · Cited by 460
The Evidence for a Narrower Thyrotropin Reference Range Is Compelling
Wartofsky, L., & Dickey, R. A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0455 · Cited by 424
Vitamin D status as an international issue: national surveys and the problem of standardization.
Sempos, C. T., Vesper, H. W., Phinney, K. W., Thienpont, L. M., & Coates, P. M. (2012) · PubMed · doi:10.3109/00365513.2012.681935 · Cited by 303
Self-citationToward Excellence in Testosterone Testing: A Consensus Statement
Rosner, W., & Vesper, H. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-1314 · Cited by 248
Roadmap for Harmonization of Clinical Laboratory Measurement Procedures
Greg Miller, W., Myers, G. L., Lou Gantzer, M., Kahn, S. E., Schönbrunner, E. R., Thienpont, L. M., Bunk, D. M., Christenson, R. H., Eckfeldt, J. H., Lo, S. F., et al. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.164012 · Cited by 213
Self-citation
Cited by
Seger, C., Shipkova, M., Christians, U., Billaud, E., Wang, P., Holt, D. W., Brunet, M., Kunicki, P. K., Pawiński, T., Langman, L. J., et al. (2016) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000269 · Cited by 145
Thienpont, L. M., Van Uytfanghe, K., De Grande, L. A. C., Reynders, D., Das, B., Faix, J. D., MacKenzie, F., Decallonne, B., Hishinuma, A., Lapauw, B., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.269456 · Cited by 101
Self-citationVan Uytfanghe, K., Ehrenkranz, J., Halsall, D., Hoff, K., Loh, T. P., Spencer, C. A., Köhrle, J., & ATA Thyroid Function Tests Writing Group (2023) · Thyroid® · doi:10.1089/thy.2023.0169 · Cited by 100
“22,104 They require appropriate assay calibrators and quality control samples.”
BackgroundReference intervals in the diagnosis of thyroid dysfunction: treating patients not numbers
Jonklaas, J., & Razvi, S. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(18)30371-1 · Cited by 100
Korevaar, T. I. M., Leung, A. M., Alexander, E. K., Bliddal, S., Boelaert, K., Brenta, G., Chou, R., Dhillon‐Smith, R. K., Dosiou, C., Eaton, J. L., et al. (2026) · Thyroid · doi:10.1177/10507256261445624 · Cited by 66
De Grande, L. A. C., Van Uytfanghe, K., Reynders, D., Das, B., Faix, J. D., MacKenzie, F., Decallonne, B., Hishinuma, A., Lapauw, B., Taelman, P., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2017.274407 · Cited by 54
Self-citationWang, D., Yu, S., Ma, C., Li, H., Qiu, L., Cheng, X., Guo, X., Yin, Y., Li, D., Wang, Z., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-1099 · Cited by 47
“It is well documented that significant differences exist between commercial immunoassay methods for TSH [36, 37] as well as for thyroid hormones [38, 39].”
BackgroundImproving Science by Overcoming Laboratory Pitfalls With Hormone Measurements
Hillebrand, J. J., Wickenhagen, W. V., & Heijboer, A. C. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa923 · Cited by 34
Approach to the Patient With Raised Thyroid Hormones and Nonsuppressed TSH
Moran, C., Schoenmakers, N. A., Halsall, D. J., Oddy, S., Lyons, G., van den Berg, S. A. A., Gurnell, M., & Chatterjee, K. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad681 · Cited by 33
Mirjanić-Azarić, B., Stojaković-Jelisavac, T., Vuković, B., Stojanović, D., Vujnić, M., & Uletilović, S. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.08.020 · Cited by 35
D’Aurizio, F., Kratzsch, J., Gruson, D., Ovčariček, P. P., & Giovanella, L. (2022) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2022.2121960 · Cited by 35
“The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests (IFCC C-STFT) developed and established a reference measurement system for FT4 standardization [4,8,95,96] and is now working with national partners on implementing it [97].”
BackgroundResultProgress in standardizing and harmonizing thyroid function tests
Faix, J. D., & Miller, W. G. (2016) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.110379 · Cited by 30
Self-citationMethod-dependent variation in TSH and FT4 reference intervals in pregnancy: A systematic review
Okosieme, O. E., Agrawal, M., Usman, D., & Evans, C. (2021) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632211026955 · Cited by 34
“The establishment of reference intervals should follow criteria set by international bodies.(11,63) Furthermore, the reporting of gestational thyroid function tests should be assay and pregnancy specific and clinicians should be alert to the potential for methodrelated differences.”
BackgroundHarmonization protocols for TSH immunoassays: a multicenter study in Italy
Clerico, A., Ripoli, A., Fortunato, A., Alfano, A., Carrozza, C., Correale, M., Dittadi, R., Gessoni, G., Migliardi, M., Rizzardi, S., et al. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0899 · Cited by 28
Osinga, J. A. J., Derakhshan, A., Feldt-Rasmussen, U., Huang, K., Vrijkotte, T. G. M., Männistö, T., Bassols, J., López-Bermejo, A., Aminorroaya, A., Vafeiadi, M., et al. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad564 · Cited by 27
“Furthermore, use of an adaptable rule based on nonpregnancy reference intervals would leave beneficial effects of international laboratory-specific standardization and harmonization efforts intact (33, 34).”
Global FT4 immunoassay standardization: an expert opinion review
Kratzsch, J., Baumann, N. A., Ceriotti, F., Lu, Z. X., Schott, M., van Herwaarden, A. E., Vieira, J. G. H., Kasapic, D., & Giovanella, L. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1696 · Cited by 29
“Data from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee for Standardization of Thyroid Function Tests (C-STFT) have demonstrated differences in results across 13 FT4 assays [19].”
BackgroundMethodResultInfluentialRichards, K., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2017.01.032 · Cited by 23
Variables Contributing to Thyroid (Dys)Function in Pregnant Women: More than Thyroid Antibodies?
Veltri, F., & Poppe, K. G. (2018) · European Thyroid Journal · doi:10.1159/000488279 · Cited by 24
Gestation specific reference intervals for thyroid function tests in pregnancy
Akarsu, S., Akbıyık, F., Karaismailoğlu, E., & Dikmen, Z. G. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0569 · Cited by 21
Kalaria, T., Sanders, A., Fenn, J. S., Ashby, H. L., Mohammed, P., Buch, H., Ford, C., & Gama, R. M. (2021) · Clinical Endocrinology · doi:10.1111/cen.14423 · Cited by 22
Padoan, A., Clerico, A., Zaninotto, M., Trenti, T., Tozzoli, R., Aloe, R., Alfano, A., Rizzardi, S., Dittadi, R., Migliardi, M., et al. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1167 · Cited by 19
“Considering these inclusion and exclusion criteria for the enrollment of the reference population, as well as the systemic bias between TSH immunoassay methods, it is not surprising that RIs for TSH have remained poorly defined [2, 13].”
BackgroundMass spectrometry in the diagnosis of thyroid disease and in the study of thyroid hormone metabolism
Borsò, M., Agretti, P., Zucchi, R., & Saba, A. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21673 · Cited by 21
Jansen, H. I., van der Steen, R., Brandt, A. M., Olthaar, A. J., Vesper, H. W., Shimizu, E., Heijboer, A. C., Uytfanghe, K. V., & van Herwaarden, A. E. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1134 · Cited by 20
Subclinical hypothyroidism: a ‘laboratory-induced’ condition?
Coene, K. L. M., Demir, A. Y., Broeren, M. A. C., Verschuure, P., Lentjes, E. G. W. M., & Boer, A. (2015) · European Journal of Endocrinology · doi:10.1530/eje-15-0684 · Cited by 17
Mass spectrometry – a key technique for traceability in clinical chemistry
Keßler, A. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.03.017 · Cited by 16
Implementing reference systems for thyroid function tests – A collaborative effort
Vesper, H. W., Van Uytfanghe, K., Hishinuma, A., Raverot, V., Patru, M. M., Danilenko, U., van Herwaarden, A. E., & Shimizu, E. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.04.019 · Cited by 15
De Grande, L. A. C., Goossens, K., Van Uytfanghe, K., Das, B., MacKenzie, F., Patru, M.-M., & Thienpont, L. M. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.04.032 · Cited by 15
Self-citationScreening for Congenital Hypothyroidism
Lau, C. S., Joseph, R., & Aw, T. C. (2020) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.2020618 · Cited by 15
Dirks, N. F., den Elzen, W. P. J., Hillebrand, J. J., Jansen, H. I., ten Boekel, E., Brinkman, J. W., Buijs, M. M., Demir, A. Y., Dijkstra, I. M., Endenburg, S. C., et al. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1237 · Cited by 14
Thienpont, L. M., Faix, J. D., & Beastall, G. H. (2015) · European Thyroid Journal · doi:10.1159/000440614 · Cited by 14
Self-citationTSH and fT4 during pregnancy: an observational study and a review of the literature
Joosen, A. M. C. P., van der Linden, I. J. M., de Jong-Aarts, N., Hermus, M. A. A., Ermens, A. A. M., & de Groot, M. J. M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0629 · Cited by 14
“Differences between assays used are evident [21] and directly related to differences in non-pregnant reference interval.”
BackgroundThienpont, L. M., Faix, J. D., & Beastall, G. H. (2015) · Endocrine Journal · doi:10.1507/endocrj.ej15-0382 · Cited by 13
“Different phases of method comparison studies were performed to investigate and confirm the feasibility of standardization of FT4 and harmonization of TSH tests, but also with attention to fit-for-the-purpose analytical quality [4-5].”
MethodSelf-citationThienpont, L. M., Faix, J. D., & Beastall, G. H. (2015) · Thyroid · doi:10.1089/thy.2015.0309 · Cited by 13
Self-citationXiong, J., Liu, S., Hu, K., Xiong, Y., Wang, P., & Xiong, L. (2020) · PLoS ONE · doi:10.1371/journal.pone.0239579 · Cited by 13
“The results of the various epidemiological studies conducted in different regions are closely related to the experimental methods used, such as previously used radioimmunoassay methods, the diagnostic criteria, and the different individuals diagnosed [1, 15, 16].”
ResultDonadio-Andréi, S., Chikh, K., Heuclin, C., Kuczewski, E., Charrié, A., Gauchez, A.-S., & Ronin, C. (2017) · European Thyroid Journal · doi:10.1159/000449463 · Cited by 11
Association between N-desethylamiodarone/amiodarone ratio and amiodarone-induced thyroid dysfunction
Yamato, M., Wada, K., Fujimoto, M., Hosomi, K., Hayashi, T., Oita, A., & Takada, M. (2017) · European Journal of Clinical Pharmacology · doi:10.1007/s00228-017-2195-5 · Cited by 12
Ursem, S. R., Boelen, A., Hillebrand, J. J., den Elzen, W. P. J., & Heijboer, A. C. (2023) · European Thyroid Journal · doi:10.1530/etj-23-0123 · Cited by 10
Jin, Y., Zhai, T., Wang, Y., Li, J., Wang, T., & Huang, J. (2024) · Journal of Separation Science · doi:10.1002/jssc.202400466 · Cited by 11
Pantalone, K. M., Hatipoğlu, B., Gupta, M. K., Kennedy, L., & Hamrahian, A. H. (2015) · Case Reports in Endocrinology · doi:10.1155/2015/965191 · Cited by 10
“…of the serum FTI may be helpful in making the diagnosis of central hypothyroidism in the appropriate clinical setting and when free T4 is in the low-normal range, particularly in patients with multiple anterior pituitary hormone deficiencies and/or with symptoms suggestive of hypothyroidism.”
BackgroundBarhanovic, N. G., Antunović, T., Kavarić, S., Djogo, A., & Spasojevic, V. K. (2018) · Journal of Medical Biochemistry · doi:10.2478/jomb-2018-0020 · Cited by 11
“The possible standardization of fT4 assays, according to an international conventional reference procedure, would change results significantly – perhaps by as much as 80% at the upper limit of the normal range – for some assays (39).”
MethodOsinga, J. A. J., Nelson, S. M., Walsh, J. P., Ashoor, G., Palomaki, G. E., López‐Bermejo, A., Bassols, J., Aminorroaya, A., Broeren, M. A. C., Chen, L., et al. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgae528 · Cited by 8
A Fresh Look at the Relationship between TSH and Free Thyroxine in Cross-Sectional Data
Grande, L. A. C. D., Uytfanghe, K. V., & Thienpont, L. M. (2015) · European Thyroid Journal · doi:10.1159/000369796 · Cited by 8
Self-citationThienpont, L. M., Faix, J. D., & Beastall, G. H. (2015) · Endocrine · doi:10.1007/s12020-015-0752-1 · Cited by 6
“(3) Implementation We wish to hear your views on how clinical laboratories can minimize the identified risks from free T4 standardization and TSH harmonization, and on the role that you could play yourself in your contact with the patients you treat.”
BackgroundSelf-citationLaboratory evaluation of thyroid function
Lin, D. C., & Straseski, J. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-815499-1.00040-5 · Cited by 5
Meng, F., Jonklaas, J., & Leow, M. K. (2021) · Biology · doi:10.3390/biology10010045 · Cited by 6
Xiong, J., Liu, S., Hu, K., Xiong, Y., Wang, P., & Liang, X. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253359 · Cited by 5
Bohn, M. K., Nyholt, D., Balion, C. M., Cembrowski, G. S., Collier, C. P., Guire, V. D., Higgins, V., Jung, B., Landon, O., Mohammed‐Ali, Z., et al. (2025) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2025.110986 · Cited by 5
Freitas, C., Rodrigues, F., Rocha, G., Simões, H., Miguel, M., & Azevedo, T. (1999) · Revista Portuguesa de Endocrinologia Diabetes e Metabolismo · doi:10.26497/na190056 · Cited by 6
Thienpont, L. M., Faix, J. D., & Beastall, G. H. (2016) · Endocrine Practice · doi:10.4158/1934-2403-22.3.374 · Cited by 4
Self-citationKuzmanovska, S., & Miladinova, D. (2020) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2020.4318 · Cited by 3
“For the FT4 immunoassays, IFCC WG-STFT and later the C-STFT, proposed standardization against reference method based on equilibrium dialysisisotope dilution-mass spectrometry [21].”
MethodThe new Roche Elecsys TSH assay conforms with current IFCC C-STFT standards
Kratzsch, J., Baumann, N. A., Ceriotti, F., Lu, Z. X., Schott, M., van Herwaarden, A. E., Vieira, J. G. H., Lehmann, H., Kasapic, D., & Giovanella, L. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0352 · Cited by 3
Thienpont, L. M., Faix, J. D., & Beastall, G. H. (2015) · Clinical Endocrinology · doi:10.1111/cen.12861 · Cited by 3
Self-citationInstability of harmonized thyroid‐stimulating hormone immunoassays in clinical practice
Uto, K., Bando, H., Fukuoka, H., Yamamoto, M., Ogasahara, A., Ono, S., Oyabu, C., Sato, I., Imanishi, T., Saegusa, J., et al. (2023) · Clinical Endocrinology · doi:10.1111/cen.14938 · Cited by 2
“TSH (IFCC) reference interval of Japanese adults (120 healthy subjects, 20–60 years of age) was determined by Committee of Standardization of Japanese Society of Laboratory Medicine.(16) UTO ET AL.”
MethodBolton, T. A., Marino, C. L., Derré, M. G., Moore, G. E., Piccione, J., & Delovio, M. L. (2025) · Frontiers in Veterinary Science · doi:10.3389/fvets.2025.1657215 · Cited by 2
Cho, G. W., Min-Jeong, K. I. M., Lee, M. Y., Kim, M. H., Lee, W. I., & Kang, S. Y. (2025) · Laboratory Medicine · doi:10.1093/labmed/lmaf091 · Cited by 2
Rasche, F. M., Rettig, R. K., Frese, T., Rasche, W., Barinka, F., Roesl, G., Keller, F., Lindner, T. H., Schneider, J. G., Beige, J., et al. (2018) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-0043-123184 · Cited by 3
“5 or > 5 mIU/l in the assays for TSH was demonstrated for patients with normal kidney function and normal albumin [20].”
BackgroundDirks, N. F., den Elzen, W. P. J., Hillebrand, J. J., Jansen, H. I., ten Boekel, E., Brinkman, J. W., Buijs, M. M., Demir, A. Y., Dijkstra, I. M., Endenburg, S. C., et al. (2024) · Laboratory Service · doi:10.17116/labs20241303150 · Cited by 1
New Immunoassays of Bioactive TSH Improve Detection of Thyroid Disorders
Donadio, S., & Ronin, C. (2017) · Journal of Thyroid Disorders & Therapy · doi:10.4172/2167-7948.1000223 · Cited by 1
“Efforts are currently done by the IFCC Committee for Standardization of Thyroid Function Tests which recently proposed a mathematical recalibration to harmonize values among manufacturers [50,51].”
MethodDoggui, R., Mahjoub, R., Aissa, W. L., Tounsi, I., Allagui, Z., Cherif, Z., Sassi, S. H., Ennigrou, S., Edriss, D., Ati, J. E., et al. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2018.07.045 · Cited by 1
Hepatoprotective Effect of Quercetin on Oxidative Stress Via TRX-1 in Metabolic Syndrome Male Rats
Bilginoğlu, A. (2019) · International Archives of Endocrinology Clinical Research · doi:10.23937/2572-407x.1510015 · Cited by 1
Harmonization of results among laboratories
Miller, W. G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-815499-1.00017-x · Cited by 1
Kalaria, T., Fenn, J. S., Sharrod–Cole, H., Sanders, A., Ford, C., & Gama, R. M. (2021) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632211042560 · Cited by 1
“Our data, however, indicate that at least one of the Abbott or Roche TSH assays is not ‘blind’ to the pituitary TSH isoforms when compared to circulating TSH.”
MethodInfluentialSchilddrüse und Schwangerschaft – Update 2023
Benker, G., & Rösler, S. (2023) · Frauenheilkunde up2date · doi:10.1055/a-1710-8889 · Cited by 1
“Die Ergebnisse der FT4-Messung hängen vom Messverfahren ab [5, 6].”
BackgroundKang, S. Y., Kim, M., Lee, M. Y., Kim, M. H., & Lee, W. I. (2024) · Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance · doi:10.15263/jlmqa.2024.46.4.214 · Cited by 1
Validation of plasma thyroxine and triiodothyronine methods on the ADVIA Centaur ® XP
Kristiansen, S., & Friis-Hansen, L. J. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2019.1571624
“In contrast, they were negatively as well as positively biased for serum FT4< 9 pmol/L [10].”
BackgroundXÂY DỰNG CƠ SỞ LIÊN THÔNG XÉT NGHIỆM TSH, FT3, FT4 THÔNG QUA CHƯƠNG TRÌNH NGOẠI KIỂM MIỄN DỊCH RIQAS
Đào, T. H., Nguyễn, T. N. H., Văn, H. T., Phạm, T. T. A., & Hà, M. T. (2023) · Tạp chí Y học Việt Nam · doi:10.51298/vmj.v520i2.4202
Al-Obaid, Q. Y., Aljenedil, S., Tamimi, W., & Alsumaily, K. (2024) · Open Journal of Medicinal Chemistry · doi:10.4236/ojmc.2024.144004
Analytical measurement of thyroid-related hormones, proteins, and autoantibodies in serum
Feldt‐Rasmussen, U. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-13825-6.00386-1
Warringa, L., Osinga, J. A. J., Derakhshan, A., Jaddoe, V. W. V., Sjoerd, A. A. V. D. B., Peeters, R. P., & Korevaar, T. I. M. (2026) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgag082
Mise en oeuvre de dosages pour le diagnostic précoce de l'hypothyroïdie
Iss, C. (2015) · theses.fr (ABES) · doi:10.70675/f9f2aeebza5a8z4cf3zb9afzd52e7504b286
Sun, Q., Lǐ, Y., Liu, Y., Wang, L., & Cao, H. (2026) · Separation Science Plus · doi:10.1002/sscp.70230
Yılmaz, E., & Yılmaz, H. K. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15155778
“While such harmonization efforts have been comparatively successful for TSH, free T4 standardization remains incomplete [52], and our findings derived independently from an external, population-based cohort provide empirical support for this ongoing concern.”
Zheng, J., Peng, G., Chen, X., Yuan, L., Gu, B., 黄, 淑., Wei, J., & 严海燕 (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.122958
Metadata
- Authors
- Thienpont, L. M., Van Uytfanghe, K., Van Houcke, S., Das, B., Faix, J. D., MacKenzie, F., Quinn, F. A., Rottmann, M., & Van den Bruel, A.
- Affiliations
- Ghent University (BE)
- 1Laboratory for Analytical Chemistry, Faculty of Pharmaceutical Sciences, Gent University, Gent
- Kokilaben Dhirubhai Ambani Hospital (IN)
- Stanford University (US)
- University Hospitals Birmingham NHS Foundation Trust (GB)
- Abbott (United States) (US)
- 7Roche Diagnostics GmbH, Penzberg, Germany
- 2Department of Endocrinology, General Hospital Sint Jan, Bruges, Belgium
- Corresponding author
- Thienpont, Linda M.
- Venue
- European Thyroid Journal
- Publisher
- Bioscientifica
- Published
- 2014-05-07
- Volume
- 3
- Issue
- 2
- Pages
- 109-116
- ISSN
- 2235-0640 (ISSN-L)
- 2235-0802
- PMC
- PMC4109515
- OpenAlex
- W2057479314
- Cited by
- 72
- References
- 34
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 6 · 2023: 8 · 2022: 1 · 2021: 6 · 2020: 9 · 2019: 3 · 2018: 5 · 2017: 6 · 2016: 7 · 2015: 11 · 2014: 1
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- European Thyroid Journal (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- thyroid function tests, free thyroxine, thyroid-stimulating hormone, assay standardization, harmonization, method comparison, inter-assay variability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.