A Progress Report of the IFCC Committee for Standardization of Thyroid Function Tests
Open accessThe DOI matches its Crossref record; 32 of the 34 references it cites were found in a registry or an index.
Abstract
Background: The IFCC Committee for Standardization of Thyroid Function Tests aims at equivalence of laboratory test results for free thyroxine (FT4) and thyrotropin (TSH). Objectives: This report describes the phase III method comparison study with clinical samples representing a broad spectrum of thyroid disease. The objective was to expand the feasibility work and explore the impact of standardization/harmonization in the clinically relevant concentration range. Methods: Two sets of serum samples (74 for FT4, 94 for TSH) were obtained in a clinical setting. Eight manufacturers participated in the study (with 13 FT4 and 14 TSH assays). Targets for FT4 were set by the international conventional reference measurement procedure of the IFCC; those for TSH were based on the all-procedure trimmed mean. The manufacturers recalibrated their assays against these targets. Results: All FT4 assays were negatively biased in the mid- to high concentration range, with a maximum interassay discrepancy of approximately 30%. However, in the low range, the maximum deviation was approximately 90%. For TSH, interassay comparability was reasonable in the mid-concentration range, but worse in the pathophysiological ranges. Recalibration was able to eliminate the interassay differences, so that the remaining dispersion of the data was nearly entirely due to within-assay random error components. The impact of recalibration on the numerical results was particularly high for FT4. Conclusions: Standardization and harmonization of FT4 and TSH measurements is feasible from a technical point of view. Because of the impact on the numerical values, the implementation needs careful preparation with the stakeholders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Current immunoassays appear to be less affected by glycosylation changes in TSH, which occur in pituitary disease.22,104”
From Thyroid Stimulating Hormone and Thyroid Hormones (Triiodothyronine and Thyroxine): An American Thyroid Association-Commissioned Review of Current Clinical and Laboratory Status (2023) · cites this paper as [104]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Alternatively, the state-of-the-art APS can be derived from the evaluation and comparison of laboratory methods99–104 or using peer comparison data from proficiency testing programs.105–107”
From Thyroid Stimulating Hormone and Thyroid Hormones (Triiodothyronine and Thyroxine): An American Thyroid Association-Commissioned Review of Current Clinical and Laboratory Status (2023) · cites this paper as [104]
Experimental — accuracy not yet measuredIn the citing paper
“In addition, the overall excellent correlation of most of the immunoassays' results to the APTM in patients with both hypo- and hyperthyroidism led the committee to conclude that the assays measured TSH in an equimolar fashion, regardless of differences in glycosylation (31).”
From Harmonization of Serum Thyroid-Stimulating Hormone Measurements Paves the Way for the Adoption of a More Uniform Reference Interval (2017) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De Groot, L., Abalovich, M., Alexander, E. K., Amino, N., Barbour, L., Cobin, R. H., Eastman, C. J., Lazarus, J. H., Luton, D., Mandel, S. J., et al. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-2803 · Cited by 1,866
Mittal, M., Kumar, A., Ramji, S., Narula, S., & Thirupuram, S. (1990) · PubMed · Cited by 1,764
Garber, J. R., Cobin, R. H., Gharib, H., Hennessey, J. V., Klein, I., Mechanick, J. I., Pessah-Pollack, R., Singer, P. A., & Woeber, K. A. (2012) · Endocrine Practice · doi:10.4158/ep12280.gl · Cited by 1,567
Myers, G. L. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.0525144 · Cited by 1,232
Laboratory Support for the Diagnosis and Monitoring of Thyroid Disease
(2003) · Thyroid · doi:10.1089/105072503321086962 · Cited by 1,212
Demers, L. M., & Spencer, C. A. (2003) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01681.x · Cited by 460
The Evidence for a Narrower Thyrotropin Reference Range Is Compelling
Wartofsky, L., & Dickey, R. A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0455 · Cited by 424
Vitamin D status as an international issue: national surveys and the problem of standardization.
Sempos, C. T., Vesper, H. W., Phinney, K. W., Thienpont, L. M., & Coates, P. M. (2012) · PubMed · doi:10.3109/00365513.2012.681935 · Cited by 303
Self-citationToward Excellence in Testosterone Testing: A Consensus Statement
Rosner, W., & Vesper, H. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-1314 · Cited by 248
Roadmap for Harmonization of Clinical Laboratory Measurement Procedures
Greg Miller, W., Myers, G. L., Lou Gantzer, M., Kahn, S. E., Schönbrunner, E. R., Thienpont, L. M., Bunk, D. M., Christenson, R. H., Eckfeldt, J. H., Lo, S. F., et al. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.164012 · Cited by 213
Self-citationIs there a need to redefine the upper normal limit of TSH?
Brabant, G., Beck-Peccoz, P., Jarzab, B., Laurberg, P., Orgiazzi, J., Szabolcs, I., Weetman, A. P., & Wiersinga, W. M. (2006) · European Journal of Endocrinology · doi:10.1530/eje.1.02136 · Cited by 211
The IFCC Reference Measurement System for HbA1c: A 6-Year Progress Report
Weykamp, C., John, W. G., Mosca, A., Hoshino, T., Little, R., Jeppsson, J.-O., Goodall, I., Miedema, K., Myers, G., Reinauer, H., et al. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.097402 · Cited by 206
Traceability in Laboratory Medicine
Vesper, H. W., & Thienpont, L. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.107052 · Cited by 168
Self-citationMyers, G. L., Kimberly, M. M., Waymack, P. P., Smith, S. J., Cooper, G. R., & Sampson, E. J. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.11.1762 · Cited by 160
Thienpont, L. M., Van Uytfanghe, K., Beastall, G., Faix, J. D., Ieiri, T., Miller, W. G., Nelson, J. C., Ronin, C., Ross, H. A., Thijssen, J. H., et al. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.140194 · Cited by 135
Self-citationThienpont, L. M., Van Uytfanghe, K., Beastall, G., Faix, J. D., Ieiri, T., Miller, W. G., Nelson, J. C., Ronin, C., Ross, H. A., Thijssen, J. H., et al. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.140178 · Cited by 128
Self-citationSapin, R., & d’Herbomez, M. (2003) · Clinical Chemistry · doi:10.1373/49.9.1531 · Cited by 104
Determination of free thyroid hormones
Thienpont, L. M., Van Uytfanghe, K., Poppe, K., & Velkeniers, B. (2013) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2013.05.012 · Cited by 102
Self-citationPerformance Characteristics of Six Third-Generation Assays for Thyroid-Stimulating Hormone
Rawlins, M. L., & Roberts, W. L. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039156 · Cited by 98
Thienpont, L. M., Van Uytfanghe, K., Beastall, G., Faix, J. D., Ieiri, T., Miller, W. G., Nelson, J. C., Ronin, C., Ross, H. A., Thijssen, J. H., et al. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.140228 · Cited by 97
Self-citationAnckaert, E., Poppe, K. G., Uytfanghe, K. V., Schiettecatte, J., Foulon, W., & Thienpont, L. M. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.05.032 · Cited by 95
Self-citationVan Houcke, S. K., Van Uytfanghe, K., Shimizu, E., Tani, W., Umemoto, M., & Thienpont, L. M. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.639 · Cited by 64
Self-citationNonthyroidal illness syndrome: evaluation of thyroid function in sick patients
Langton, J. E., & Brent, G. A. (2002) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(01)00008-1 · Cited by 55
Standardization of Hormonal Assays for the 21st Century
Wartofsky, L., & Handelsman, D. J. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2369 · Cited by 46
Standardization in clinical enzymology: a challenge for the theory of metrological traceability
Infusino, I., Schumann, G., Ceriotti, F., & Panteghini, M. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.075 · Cited by 43
Donadio, S., Pascual, A., Thijssen, J. H., & Ronin, C. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.058172 · Cited by 37
Standardization activities in the field of thyroid function tests: a status report
Thienpont, L. M., Van Uytfanghe, K., & Van Houcke, S. (2010) · cclm · doi:10.1515/cclm.2010.321 · Cited by 29
Self-citationDonadio, S., Morelle, W., Pascual, A., Romi-Lebrun, R., Michalski, J.-C., & Ronin, C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.091 · Cited by 28
Thienpont, L. M., & Houcke, S. K. V. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.09.001 · Cited by 24
Self-citationAccuracy in clinical chemistry – who will kiss Sleeping Beauty awake?
Thienpont, L. M. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.245 · Cited by 21
Self-citationHoucke, S. K. V., Aelst, S. V., Uytfanghe, K. V., & Thienpont, L. M. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0661 · Cited by 19
Self-citationPanteghini, M., Young, I. S., & Gillery, P. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.320 · Cited by 4
Cited by
Seger, C., Shipkova, M., Christians, U., Billaud, E., Wang, P., Holt, D. W., Brunet, M., Kunicki, P. K., Pawiński, T., Langman, L. J., et al. (2016) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000269 · Cited by 143
Thienpont, L. M., Van Uytfanghe, K., De Grande, L. A. C., Reynders, D., Das, B., Faix, J. D., MacKenzie, F., Decallonne, B., Hishinuma, A., Lapauw, B., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.269456 · Cited by 101
Self-citationVan Uytfanghe, K., Ehrenkranz, J., Halsall, D., Hoff, K., Loh, T. P., Spencer, C. A., Köhrle, J., & ATA Thyroid Function Tests Writing Group (2023) · Thyroid® · doi:10.1089/thy.2023.0169 · Cited by 100
“22,104 They require appropriate assay calibrators and quality control samples.”
BackgroundReference intervals in the diagnosis of thyroid dysfunction: treating patients not numbers
Jonklaas, J., & Razvi, S. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(18)30371-1 · Cited by 100
Korevaar, T. I. M., Leung, A. M., Alexander, E. K., Bliddal, S., Boelaert, K., Brenta, G., Chou, R., Dhillon‐Smith, R. K., Dosiou, C., Eaton, J. L., et al. (2026) · Thyroid · doi:10.1177/10507256261445624 · Cited by 66
Metadata
- Authors
- Thienpont, L. M., Van Uytfanghe, K., Van Houcke, S., Das, B., Faix, J. D., MacKenzie, F., Quinn, F. A., Rottmann, M., & Van den Bruel, A.
- Affiliations
- Ghent University (BE)
- 1Laboratory for Analytical Chemistry, Faculty of Pharmaceutical Sciences, Gent University, Gent
- Kokilaben Dhirubhai Ambani Hospital (IN)
- Stanford University (US)
- University Hospitals Birmingham NHS Foundation Trust (GB)
- Abbott (United States) (US)
- 7Roche Diagnostics GmbH, Penzberg, Germany
- 2Department of Endocrinology, General Hospital Sint Jan, Bruges, Belgium
- Corresponding author
- Thienpont, Linda M.
- Venue
- European Thyroid Journal
- Publisher
- Bioscientifica
- Published
- 2014-05-07
- Volume
- 3
- Issue
- 2
- Pages
- 109-116
- ISSN
- 2235-0640 (ISSN-L)
- 2235-0802
- PMC
- PMC4109515
- OpenAlex
- W2057479314
- Cited by
- 72
- References
- 34
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 6 · 2023: 8 · 2022: 1 · 2021: 6 · 2020: 9 · 2019: 3 · 2018: 5 · 2017: 6 · 2016: 7 · 2015: 11 · 2014: 1
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- European Thyroid Journal (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- thyroid function tests, free thyroxine, thyroid-stimulating hormone, assay standardization, harmonization, method comparison, inter-assay variability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.