In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background— The current understanding of the pathophysiology of coronary artery disease is based largely on postmortem studies. Optical coherence tomography (OCT) is a high-resolution (≈10 μm), catheter-based imaging modality capable of investigating detailed coronary plaque morphology in vivo. Methods and Results— Patients undergoing cardiac catheterization were enrolled and categorized according to their clinical presentation: recent acute myocardial infarction (AMI), acute coronary syndromes (ACS) constituting non-ST-segment elevation AMI and unstable angina, or stable angina pectoris (SAP). OCT imaging was performed with a 3.2F catheter. Two observers independently analyzed the images using the previously validated criteria for plaque characterization. Of 69 patients enrolled, 57 patients (20 with AMI, 20 with ACS, and 17 with SAP) had analyzable images. In the AMI, ACS, and SAP groups, lipid-rich plaque (defined by lipid occupying ≥2 quadrants of the cross-sectional area) was observed in 90%, 75%, and 59%, respectively ( P =0.09). The median value of the minimum thickness of the fibrous cap was 47.0, 53.8, and 102.6 μm, respectively ( P =0.034). The frequency of thin-cap fibroatheroma (defined by lipid-rich plaque with cap thickness ≤65 μm) was 72% in the AMI group, 50% in the ACS group, and 20% in the SAP group ( P =0.012). No procedure-related complications occurred. Conclusions— OCT is a safe and effective modality for characterizing coronary atherosclerotic plaques in vivo. Thin-cap fibroatheroma was more frequently observed in patients with AMI or ACS than SAP. This is the first study to compare detailed in vivo plaque morphology in patients with different clinical presentations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Virmani, R., Kolodgie, F. D., Burke, A. P., Farb, A., & Schwartz, S. M. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.5.1262 · Cited by 4,084
Falk, E., Shah, P. K., & Fuster, V. (1995) · Circulation · doi:10.1161/01.cir.92.3.657 · Cited by 3,536
Thrombosis and Acute Coronary-Artery Lesions in Sudden Cardiac Ischemic Death
Davies, M. J., & Thomas, A. (1984) · New England Journal of Medicine · doi:10.1056/nejm198405033101801 · Cited by 1,694
Current Concepts of the Pathogenesis of the Acute Coronary Syndromes
Libby, P. (2001) · Circulation · doi:10.1161/01.cir.104.3.365 · Cited by 1,558
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Self-citationJang, I.-K., Bouma, B. E., Kang, D.-H., Park, S.-J., Park, S.-W., Seung, K.-B., Choi, K.-B., Shishkov, M., Schlendorf, K., Pomerantsev, E., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01799-5 · Cited by 1,000
Self-citationStability and Instability: Two Faces of Coronary Atherosclerosis: The Paul Dudley White Lecture 1995
Davies, M. J. (1996) · Circulation · doi:10.1161/01.cir.94.8.2013 · Cited by 915
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
Self-citationHigh-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Self-citation
Cited by
Concept of Vulnerable/Unstable Plaque
Finn, A. V., Nakano, M., Narula, J., Kolodgie, F. D., & Virmani, R. (2010) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.108.179739 · Cited by 1,191
Multislice Computed Tomographic Characteristics of Coronary Lesions in Acute Coronary Syndromes
Motoyama, S., Kondo, T., Sarai, M., Sugiura, A., Harigaya, H., Sato, T., Inoue, K., Okumura, M., Ishii, J., Anno, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.044 · Cited by 1,026
Prati, F., Regar, E., Mintz, G. S., Arbustini, E., Di Mario, C., Jang, I.-K., Akasaka, T., Costa, M., Guagliumi, G., Grube, E., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp433 · Cited by 880
Self-citationAssessment of Culprit Lesion Morphology in Acute Myocardial Infarction
Kubo, T., Imanishi, T., Takarada, S., Kuroi, A., Ueno, S., Yamano, T., Tanimoto, T., Matsuo, Y., Masho, T., Kitabata, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.082 · Cited by 867
Stone, P. H., Saito, S., Takahashi, S., Makita, Y., Nakamura, S., Kawasaki, T., Takahashi, A., Katsuki, T., Nakamura, S., Namiki, A., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.096438 · Cited by 609
Assessment of Coronary Arterial Plaque by Optical Coherence Tomography
Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.035 · Cited by 573
Molecular imaging: current status and emerging strategies
Pysz, M. A., Gambhir, S. S., & Willmann, J. K. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.03.011 · Cited by 572
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Narula, J., Nakano, M., Virmani, R., Kolodgie, F. D., Petersen, R., Newcomb, R., Malik, S., Fuster, V., & Finn, A. V. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.10.054 · Cited by 529
Comprehensive volumetric optical microscopy in vivo
Yun, S. H., Tearney, G. J., Vakoc, B. J., Shishkov, M., Oh, W. Y., Desjardins, A. E., Suter, M. J., Chan, R. C., Evans, J. A., Jang, I.-K., et al. (2006) · Nature Medicine · doi:10.1038/nm1450 · Cited by 438
Self-citationST-segment elevation myocardial infarction
Vogel, B., Claessen, B. E., Arnold, S. V., Chan, D., Cohen, D. J., Giannitsis, E., Gibson, C. M., Goto, S., Katus, H. A., Kerneis, M., et al. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0090-3 · Cited by 419
Prati, F., Guagliumi, G., Mintz, G. S., Costa, M., Regar, E., Akasaka, T., Barlis, P., Tearney, G. J., Jang, I.-K., Arbustini, E., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs095 · Cited by 400
Self-citationKang, S.-J., Mintz, G. S., Akasaka, T., Park, D.-W., Lee, J.-Y., Kim, W.-J., Lee, S.-W., Kim, Y.-H., Whan Lee, C., Park, S.-W., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.988436 · Cited by 359
Prevalence of spontaneous coronary artery dissection in patients with acute coronary syndrome
Nishiguchi, T., Tanaka, A., Ozaki, Y., Taruya, A., Fukuda, S., Taguchi, H., Iwaguro, T., Ueno, S., Okumoto, Y., & Akasaka, T. (2016) · European Heart Journal: Acute Cardiovascular Care · doi:10.1177/2048872613504310 · Cited by 343
Three-Dimensional Coronary Artery Microscopy by Intracoronary Optical Frequency Domain Imaging
Tearney, G. J., Waxman, S., Shishkov, M., Vakoc, B. J., Suter, M. J., Freilich, M. I., Desjardins, A. E., Oh, W.-Y., Bartlett, L. A., Rosenberg, M., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.06.007 · Cited by 324
Self-citationNiccoli, G., Montone, R. A., Di Vito, L., Gramegna, M., Refaat, H., Scalone, G., Leone, A. M., Trani, C., Burzotta, F., Porto, I., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv029 · Cited by 292
Measurement of the thickness of the fibrous cap by optical coherence tomography
Kume, T., Akasaka, T., Kawamoto, T., Okura, H., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.030 · Cited by 273
Clinical classification of plaque morphology in coronary disease
Otsuka, F., Joner, M., Prati, F., Virmani, R., & Narula, J. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.62 · Cited by 266
Soeda, T., Uemura, S., Park, S.-J., Jang, Y., Lee, S., Cho, J.-M., Kim, S.-J., Vergallo, R., Minami, Y., Ong, D. S., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.014704 · Cited by 260
Self-citationXu, C., Schmitt, J. M., Carlier, S. G., & Virmani, R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2927464 · Cited by 255
From Bench to Bedside A Novel Technique of Acquiring OCT Images
Prati, F., Cera, M., Ramazzotti, V., Imola, F., Giudice, R., Giudice, M., Propris, S. D., & Albertucci, M. (2008) · Circulation Journal · doi:10.1253/circj.72.839 · Cited by 254
Ferrante, G., Nakano, M., Prati, F., Niccoli, G., Mallus, M. T., Ramazzotti, V., Montone, R. A., Kolodgie, F. D., Virmani, R., & Crea, F. (2010) · Circulation · doi:10.1161/circulationaha.110.955302 · Cited by 235
Takarada, S., Imanishi, T., Kubo, T., Tanimoto, T., Kitabata, H., Nakamura, N., Tanaka, A., Mizukoshi, M., & Akasaka, T. (2009) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2008.05.014 · Cited by 225
Nadkarni, S. K., Pierce, M. C., Park, B. H., de Boer, J. F., Whittaker, P., Bouma, B. E., Bressner, J. E., Halpern, E., Houser, S. L., & Tearney, G. J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.11.040 · Cited by 223
Self-citationLiang, W., Mavadia, J., & Li, X. (2013) · Series in Medical Physics and Biomedical Engineering · doi:10.1201/b16289-14 · Cited by 215
Tan, Y., Sheng, Z., Zhou, P., Liu, C., Zhao, H., Song, L., Li, J., Zhou, J., Chen, Y., Wang, L., et al. (2019) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.118.007281 · Cited by 113
High-resolution three-dimensional imaging of biofilm development using optical coherence tomography
Xi, C., Marks, D. L., Schlachter, S., Luo, W., & Boppart, S. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2209962 · Cited by 106
Yamaura, H., Otsuka, K., Ishikawa, H., Shirasawa, K., Fukuda, D., & Kasayuki, N. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.824470 · Cited by 40
“Although the concept of rupture-prone “vulnerable plaque” was a driving motivation of the identification of patients at risk of ACS (5, 29), there are debates regarding how to diagnose patients who are most likely to develop coronary atherosclerotic disease burden leading to ACS (3).”
BackgroundYoshikawa, D., Ishii, H., Kurebayashi, N., Sato, B., Hayakawa, S., Ando, H., Hayashi, M., Isobe, S., Okumura, T., Hirashiki, A., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.05.047 · Cited by 33
Metadata
- Authors
- Jang, I.-K., Tearney, G. J., MacNeill, B., Takano, M., Moselewski, F., Iftima, N., Shishkov, M., Houser, S., Aretz, H. T., Halpern, E. F., & Bouma, B. E.
- Venue
- Circulation
- Published
- 2005-03-29
- Volume
- 111
- Issue
- 12
- Pages
- 1551-1555
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2147801509
- Cited by
- 896
- References
- 20
- FWCI
- 34.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.