The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients.
Abstract
To assess the accuracy of positron emission tomography (PET) for evaluation of coronary artery disease (CAD), cardiac PET perfusion images were obtained at rest and with dipyridamole-handgrip stress in 193 patients undergoing coronary arteriography. PET images were reviewed by two independent readers blinded to clinical data. Subjective defect severity scores were assigned to each myocardial region on a 0 (normal) to 5 (severe) scale. Results were compared with arteriographic stenosis severity expressed as stenosis flow reserve (SFR), with continuous values ranging from 0 (total occlusion) to 5 (normal), calculated from quantitative arteriographic dimensions using automated detection of the vessel borders. There were 115 patients with significant CAD (SFR less than 3), 37 patients with mild CAD (3 less than or equal to SFR less than 4), and 41 patients with essentially normal coronaries (SFR greater than or equal to 4). With increasingly severe impairment of stenosis flow reserve, subjective PET defect severity increased. Despite wide scatter, a PET score of 2 or more was highly predictive of significant flow reserve impairment (SFR less than 3). For each patient, the score of the most severe PET defect correlated with the SFR of that patient's most severe stenosis (rs = 0.77 +/- 0.06). For each of 243 stenoses, PET defect score correlated with the SFR of the corresponding artery (rs = 0.63 +/- 0.08). PET defect location closely matched the region supplied by the diseased artery, and readers agreed whether the most severe PET defect was less than or more than 2 for 89% of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
White, C. W., Wright, C. B., Doty, D. B., Hiratza, L. F., Eastham, C. L., Harrison, D. G., & Marcus, M. L. (1984) · New England Journal of Medicine · doi:10.1056/nejm198403293101304 · Cited by 1,222
Documenta Geigy; scientific tables.
(1963) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1963.03700140139041 · Cited by 778
Brown, B. G., Bolson, E., Frimer, M., & Dodge, H. T. (1977) · Circulation · doi:10.1161/01.cir.55.2.329 · Cited by 633
Wilson, R. F., Laughlin, D. E., Ackell, P. H., Chilian, W. M., Holida, M. D., Hartley, C. J., Armstrong, M. L., Marcus, M. L., & White, C. W. (1985) · Circulation · doi:10.1161/01.cir.72.1.82 · Cited by 509
N-13 ammonia as an indicator of myocardial blood flow.
Schelbert, H. R., Phelps, M. E., Huang, S. C., MacDonald, N. S., Hansen, H. W., Selin, C. E., & Kuhl, D. E. (1981) · Circulation · doi:10.1161/01.cir.63.6.1259 · Cited by 452
Kirkeeide, R. L., Gould, K. L., & Parsel, L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80266-2 · Cited by 325
Self-citationGould, K. L., Goldstein, R. A., Mullani, N. A., Kirkeeide, R. L., Wong, W.-H., Tewson, T. J., Berridge, M. S., Bolomey, L. A., Hartz, R. K., Smalling, R. W., et al. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80336-9 · Cited by 275
Self-citationVisual estimates of percent diameter coronary stenosis: “A battered gold standard”
Marcus, M. L., Skorton, D. J., Johnson, M. R., Collins, S. M., Harrison, D. G., & Kerber, R. E. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90226-4 · Cited by 262
Brown, B. G., Josephson, M. A., Petersen, R. B., Pierce, C. D., Wong, M., Hecht, H. S., Bolson, E., & Dodge, H. T. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90323-4 · Cited by 227
Ritchie, J. L., Zaret, B. L., Strauss, H. W., Pitt, B., Berman, D. S., Schelbert, H. R., Ashburn, W. L., Berger, H. J., & Hamilton, G. W. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90926-8 · Cited by 208
Cited by
Relation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Coronary flow reserve as a physiologic measure of stenosis severity
Gould, K. L., Kirkeeide, R. L., & Buchi, M. (1990) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80078-6 · Cited by 548
Self-citationSchindler, T. H., Schelbert, H. R., Quercioli, A., & Dilsizian, V. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.04.007 · Cited by 424
Di Carli, M., Czernin, J., Hoh, C. K., Gerbaudo, V. H., Brunken, R. C., Huang, S.-C., Phelps, M. E., & Schelbert, H. R. (1995) · Circulation · doi:10.1161/01.cir.91.7.1944 · Cited by 372
Yoshinaga, K., Chow, B. J. W., Williams, K., Chen, L., deKemp, R. A., Garrard, L., Lok-Tin Szeto, A., Aung, M., Davies, R. A., Ruddy, T. D., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.025 · Cited by 349
Mc Ardle, B. A., Dowsley, T. F., deKemp, R. A., Wells, G. A., & Beanlands, R. S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.038 · Cited by 348
Caiati, C., Montaldo, C., Zedda, N., Bina, A., & Iliceto, S. (1999) · Circulation · doi:10.1161/01.cir.99.6.771 · Cited by 347
Gould, K. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530110056036 · Cited by 329
Self-citationGould, K. L., Pan, T., Loghin, C., Johnson, N. P., Guha, A., & Sdringola, S. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.039792 · Cited by 292
Self-citationClinical Myocardial Perfusion PET/CT
Di Carli, M. F., Dorbala, S., Meserve, J., El Fakhri, G., Sitek, A., & Moore, S. C. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032789 · Cited by 290
New Technology for Noninvasive Evaluation of Coronary Artery Disease
Di Carli, M. F., & Hachamovitch, R. (2007) · Circulation · doi:10.1161/circulationaha.106.629808 · Cited by 282
Ritchie, J. L., Bateman, T. M., Bonow, R. O., Crawford, M. H., Gibbons, R. J., Hall, R. J., O'Rourke, R. A., Parisi, A. F., Verani, M. S., Cheitlin, M. D., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)90027-6 · Cited by 281
Parkash, R., deKemp, R. A., Ruddy, T. D., Kitsikis, A., Hart, R., Beauschene, L., Williams, K., Davies, R. A., Labinaz, M., & Beanlands, R. S. B. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.04.005 · Cited by 277
Sampson, U. K., Dorbala, S., Limaye, A., Kwong, R., & Di Carli, M. F. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.015 · Cited by 277
Gould, K. L., Ornish, D., Kirkeeide, R., Brown, S., Stuart, Y., Buchi, M., Billings, J., Armstrong, W., Ports, T., & Scherwitz, L. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90781-s · Cited by 111
Self-citationThe Estrogen Replacement and Atherosclerosis (ERA) Study
Herrington, D. M., Reboussin, D. M., Klein, K. P., Sharp, P. C., Shumaker, S. A., Snyder, T. E., & Geisinger, K. R. (2000) · Controlled Clinical Trials · doi:10.1016/s0197-2456(00)00054-4 · Cited by 74
Metadata
- Authors
- Demer, L. L., Gould, K. L., Goldstein, R. A., Kirkeeide, R. L., Mullani, N. A., Smalling, R. W., Nishikawa, A., & Merhige, M. E.
- Venue
- Circulation
- Published
- 1989-04
- Volume
- 79
- Issue
- 4
- Pages
- 825-835
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2060404777
- Cited by
- 316
- References
- 16
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.