CoChat
Cited by 400

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Patent Foramen Ovale Is an Important Predictor of Adverse Outcome in Patients With Major Pulmonary Embolism

Open access
Konstantinides, Stavros, Geibel, Annette, Kasper, Wolfgang, Olschewski, Manfred, Blümel, Liane, Just, Hanjörg · 1998 · Circulation

Abstract

Background —Right-to-left shunt through a patent foramen ovale is frequently diagnosed by contrast echocardiography and can be particularly prominent in the presence of elevated pressures in the right side of the heart. Its prognostic significance in patients with pulmonary thromboembolism, however, is unknown. Methods and Results —The present prospective study included 139 consecutive patients with major pulmonary embolism diagnosed on the basis of clinical, echocardiographic, and cardiac catheterization criteria. All patients underwent contrast echocardiography at presentation. The end points of the study were overall mortality and complicated clinical course during the hospital stay defined as death, cerebral or peripheral arterial thromboembolism, major bleeding, or need for endotracheal intubation or cardiopulmonary resuscitation. Patent foramen ovale was diagnosed in 48 patients (35%). These patients had a death rate of 33% as opposed to 14% in patients with a negative echo-contrast examination ( P =.015). Logistic regression analysis demonstrated that the only independent predictors of mortality in the study population were a patent foramen ovale (odds ratio [OR], 11.4; P <.001) and arterial hypotension at presentation (OR, 26.3; P <.001). Patients with a patent foramen ovale also had a significantly higher incidence of ischemic stroke (13% versus 2.2%; P =.02) and peripheral arterial embolism (15 versus 0%; P <.001). Overall, the risk of a complicated in-hospital course was 5.2 times higher in this patient group ( P <.001). Conclusions —In patients with major pulmonary embolism, echocardiographic detection of a patent foramen ovale signifies a particularly high risk of death and arterial thromboembolic complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.97.19.1946

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Konstantinides, S., Geibel, A., Kasper, W., Olschewski, M., Blümel, L., & Just, H.
Venue
Circulation
Published
1998-05-19
Volume
97
Issue
19
Pages
1946-1951
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1996930100
Cited by
400
References
10
FWCI
9.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.