Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Background —Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. Methods and Results —Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% ( P <0.001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% ( P <0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P <0.001). Among patients with CAD, there was a good correspondence with disease. Conclusions —Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
The Nuclear Induction Experiment
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.70.474 · Cited by 1,192
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801
A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography
Manning, W. J., Li, W., & Edelman, R. R. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281202 · Cited by 544
Self-citationFast algorithms for low-level vision
Deriche, R. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.41386 · Cited by 492
Wang, Y., Riederer, S. J., & Ehman, R. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330517 · Cited by 491
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
Bottomley, P. A., Hardy, C. J., Argersinger, R. E., & Allen‐Moore, G. (1987) · Medical Physics · doi:10.1118/1.596111 · Cited by 471
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Wang, Y., Rossman, P. J., Grimm, R. C., Riederer, S. J., & Ehman, R. L. (1996) · Radiology · doi:10.1148/radiology.198.1.8539406 · Cited by 386
Coronary arteries: breath-hold MR angiography.
Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991) · Radiology · doi:10.1148/radiology.181.3.1947074 · Cited by 361
Self-citationStuber, M., Botnar, R. M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au50579 · Cited by 256
Self-citationLi, D., Paschal, C. B., Haacke, E. M., & Adler, L. P. (1993) · Radiology · doi:10.1148/radiology.187.2.8475281 · Cited by 224
NMR relaxation times of blood: dependence on field strength, oxidation state, and cell integrity.
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · PubMed · Cited by 213
Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating.
Li, D., Kaushikkar, S., Haacke, E. M., Woodard, P. K., Dhawale, P. J., Kroeker, R. M., Laub, G., Kuginuki, Y., & Gutierrez, F. R. (1996) · Radiology · doi:10.1148/radiology.201.3.8939242 · Cited by 205
NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198707000-00025 · Cited by 195
Magnetic resonance imaging of coronary arteries: technique and preliminary results.
Pennell, D. J., Keegan, J., Firmin, D. N., Gatehouse, P. D., Underwood, S. R., & Longmore, D. B. (1993) · Heart · doi:10.1136/hrt.70.4.315 · Cited by 171
Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography.
Goldfarb, J. W., & Edelman, R. R. (1998) · Radiology · doi:10.1148/radiology.206.3.9494509 · Cited by 158
Assessment of coronary artery stenosis by magnetic resonance imaging.
Pennell, D. J., Bogren, H. G., Keegan, J., Firmin, D. N., & Underwood, S. R. (1996) · Heart · doi:10.1136/hrt.75.2.127 · Cited by 158
Magnetization Transfer and T2 Relaxation Components in Tissue
Harrison, R., Bronskill, M. J., & Henkelman, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330406 · Cited by 140
Hofman, M. B. M., Henson, R. E., Kov�cs, S. J., Fischer, S., Lauffer, R. B., Adzamli, K., Becker, J. D., Wickline, S. A., & Lorenz, C. H. (1999) · Magnetic Resonance in Medicine · Cited by 77
Cited by
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
Self-citationWRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Self-citationClinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Self-citationFayad, Z. A., Fuster, V., Fallon, J. T., Jayasundera, T., Worthley, S. G., Helft, G., Aguinaldo, J. G., Badimon, J. J., & Sharma, S. K. (2000) · Circulation · doi:10.1161/01.cir.102.5.506 · Cited by 581
Metadata
- Authors
- Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J.
- Venue
- Circulation
- Published
- 1999-06-22
- Volume
- 99
- Issue
- 24
- Pages
- 3139-3148
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2036115983
- Cited by
- 425
- References
- 21
- FWCI
- 25.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.