The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation
Abstract
BACKGROUND: The purpose of this study was to provide an updated worldwide report on the methods, efficacy, and safety of catheter ablation of atrial fibrillation (AF). METHODS AND RESULTS: A questionnaire with 46 questions was sent to 521 centers from 24 countries in 4 continents. Complete interviews were collected from 182 centers, of which 85 reported to have performed 20,825 catheter ablation procedures on 16,309 patients with AF between 2003 and 2006. The median number of procedures per center was 245 (range, 2 to 2715). All centers included paroxysmal AF, 85.9% also included persistent and 47.1% also included long-lasting AF. Carto-guided left atrial circumferential ablation (48.2% of patients) and Lasso-guided ostial electric disconnection (27.4%) were the most commonly used techniques. Efficacy data were analyzed with centers representing the unit of analysis. Of 16,309 patients with full disclosure of outcome data, 10 488 (median, 70.0%; interquartile range, 57.7% to 75.4%) became asymptomatic without antiarrhythmic drugs and another 2047 (10.0%; 0.5% to 17.1%) became asymptomatic in the presence of previously ineffective antiarrhythmic drugs over 18 (range, 3 to 24) months of follow-up. Success rates free of antiarrhythmic drugs and overall success rates were significantly larger in 9590 patients with paroxysmal AF (74.9% and 83.2%) than in 2800 patients with persistent AF (64.8% and 75.0%) and 1108 patients with long-lasting AF (63.1% and 72.3%) (P<0.0001). Major complications were reported in 741 patients (4.5%). CONCLUSIONS: When analyzed in a large number of electrophysiology laboratories worldwide, catheter ablation of AF shows to be effective in approximately 80% of patients after 1.3 procedures per patient, with approximately 70% of them not requiring further antiarrhythmic drugs during intermediate follow-up.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In patients who experience symptomatic recurrences of AF despite antiarrhythmic drug therapy, all RCTs showed better sinus rhythm maintenance with catheter ablation than on antiarrhythmic drugs.586,713,727,728”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [727]
In the citing paper
“Five to seven per cent of patients will suffer severe complications after catheter ablation of AF, and 2-3% will experience life-threatening but usually manageable complications.727,[748][749][750]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [727]
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Nademanee, K., McKenzie, J. P., Kosar, E. M., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,004
Calkins, H. G., Brugada, J., Packer, D. L., Cappato, R., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Haines, D. E., Haı̈ssaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,690
Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary Veins
Chen, S., HSIEH, M., TAI, C., Tsai, C.-F., Prakash, V. S., Yu, W., Hsu, T., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,442
Cappato, R., Calkins, H. G., Chen, S., Davies, W. D., Iesaka, Y., Kalman, J. M., Kim, Y.-H., Klein, G. J., Packer, D. L., & Skanes, A. C. (2005) · Circulation · doi:10.1161/01.cir.0000157153.30978.67 · Cited by 1,303
A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jaı̈s, P., Haı̈ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Clémenty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,114
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S. A., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Circumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation
Oral, H., Pappone, C., Chugh, A., Good, E. D., Bogun, F. M., Pelosi, F., Bates, E., Lehmann, M. H., Vicedomini, G., Augello, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa050955 · Cited by 975
Haı̈ssaguerre, M., Jaı̈s, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R. P., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 921
Catheter Ablation for Paroxysmal Atrial Fibrillation
Oral, H., Scharf, C., Chugh, A., HALL, B. W., Cheung, P. W., Good, E. D., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Cited by
Sorted by citations
Items 401–500 of 1,003
Sohara, H., Satake, S., Takeda, H., YAMAGUCHI, Y., & Nagasu, N. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12394 · Cited by 69
Yu, H. T., Shim, J., Park, J., Kim, I., Kim, T., Uhm, J., Joung, B., Lee, M., Kim, Y., & Pak, H. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004915 · Cited by 68
“After blanking period, n (%) 29 (26) 13 (22) 16 (30) 0.”
Respiratory motion compensation by model-based catheter tracking during EP procedures
Brost, A., Liao, R., Strobel, N. K., & Joachim Hornegger, A. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.006 · Cited by 68
Guiot, A., Jongnarangsin, K., Chugh, A., Suwanagool, A., Latchamsetty, R., Myles, J. D., Jiang, Q., Crawford, T. C., Good, E. D., Pelosi, F., et al. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02141.x · Cited by 68
Hoyer, F. F., Lickfett, L., Mittmann-Braun, E. L., Ruland, C., Kreuz, J., Pabst, S., SCHRICKEL, J. W., Juergens, U. R., Tasci, S., Nickenig, G., et al. (2010) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9502-8 · Cited by 68
“Beside conventional drug therapy, pulmonary vein isolation is an established and promising method for treating AF and usually results in elimination or significant reduction of AF burden [6–9].”
BackgroundLacomis, J. M., Goitein, O., Deible, C. R., & SCHWARTZMAN, D. S. (2007) · Journal of Thoracic Imaging · doi:10.1097/rti.0b013e3180317aaf · Cited by 68
A Review of Recent Advances in Registration Techniques Applied to Minimally Invasive Therapy
Liao, R., Zhang, L., Sun, Y., Miao, S., & Chefd'Hotel, C. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244869 · Cited by 71
Bordignon, S., Chun, K. R. J., Gunawardene, M., Fuernkranz, A., URBAN, V., Schulte‐Hahn, B., Nowak, B., & Schmidt, B. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12192 · Cited by 67
External Arrhythmia Ablation Using Photon Beams
Lehmann, H. I., Deisher, A., Takami, M., Kruse, J. J., Song, L., Anderson, S. E., Cusma, J. T., Parker, K. D., Johnson, S. B., Asirvatham, S. J., et al. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004304 · Cited by 67
“In addition, catheter-ablation is associated with many different risks such as thromboembolic events,(6,7) pulmonary vein stenosis, and atrial–esophageal fistula formation.(8,9)”
BackgroundGorog, D. A., Gue, Y. X., Chao, T., Fauchier, L., Ferreiro, J. L., Huber, K., Konstantinides, S., Lane, D. A., Marín, F. R., Oldgren, J., et al. (2022) · EP Europace · doi:10.1093/europace/euac020 · Cited by 70
Everett, T. H., Lee, K. W., Wilson, E., Palmero, M. J. G., Varosy, P. D., & Olgin, J. E. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01305.x · Cited by 67
Richmond, L., Rajappan, K., Voth, E. J., RANGAVAJHALA, V., Earley, M. J., Thomas, G., Harris, S. J., Sporton, S. C., & SCHILLING, R. J. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01127.x · Cited by 67
Chao, T., Kibos, A., Tsao, H.-M., Lin, Y., Chang, S., Lo, L., Hu, Y., Tuan, T., Suenari, K., Li, C.-H., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.03.007 · Cited by 67
Lin, Y., Chao, T., Tsao, H.-M., Chang, S., Lo, L., Chiang, C., Hu, Y., Hsu, P., Chuang, S., Li, C.-H., et al. (2012) · EP Europace · doi:10.1093/europace/eus336 · Cited by 67
Suenari, K., Nakano, Y., Hirai, Y., Ogi, H., Oda, N., Makita, Y., Ueda, S., Kajihara, K., Tokuyama, T., Motoda, C., et al. (2012) · Heart and Vessels · doi:10.1007/s00380-012-0253-6 · Cited by 67
Winkle, R. A., Mead, R. H., Engel, G., & Patrawala, R. A. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02990.x · Cited by 66
Phillips, K. P., Romanov, A., Николаевич, А. С., Folkeringa, R., Szili‐Törok, T., Senatore, G., Steín, K. M., Omar, R., Gordon, N. T., & Boersma, L. V. A. (2019) · EP Europace · doi:10.1093/europace/euz286 · Cited by 66
“Further the results show good periprocedural safety for high-volume ablation operators with procedural complication rates similar to those reported for catheter ablation therapy alone.(12) The results are consistent with two other multicentre reports of mid to long-term outcomes following combined ablation and LAAC pr…”
ResultKupó, P., Pap, R., Sághy, L., Tényi, D., Bálint, A., Debreceni, D., Basu‐Ray, I., & Komócsi, A. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00683-z · Cited by 66
Ma, W., Liu, J., Zeng, Y. J., Chen, S., Zheng, Y., Ye, S., Lan, L., Liu, Q., Weig, H., & Liu, Q. (2011) · Herz · doi:10.1007/s00059-011-3428-5 · Cited by 66
Sohns, C., Sohns, J. M. S., Vollmann, D., Lüthje, L., Bergau, L., Dorenkamp, M., Zwaka, P., Hasenfuss, G. P., Lotz, J., & Zabel, M. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet017 · Cited by 66
Lim, H. E., Pak, H., Tse, H., Lau, C., Hwang, C., & Kim, Y. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.026 · Cited by 66
Bai, R., Biase, L. D., Valderrábano, M., Lorgat, F., MLCOCHOVA, H., Tilz, R. R., Meyerfeldt, U., Hranitzky, P. M., Wazni, O. M., Kanagaratnam, P., et al. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02316.x · Cited by 66
Wieczorek, M., Lukat, M., Hoeltgen, R., Condie, C., HILJE, T., Missler, U., Hirsch, J., & Scharf, C. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12006 · Cited by 66
Scaglione, M., Blandino, A., Raimondo, C., Caponi, D., Donna, P. D., Toso, E., Ebrille, E., Cesarani, F., Ferrarese, E., & Gaïta, F. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02298.x · Cited by 65
Rostamian, A., Narayan, S. M., Thomson, L., Fishbein, M. C., & Siegel, R. J. (2014) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-014-9885-z · Cited by 65
“4 %) [7, 9–20], whereas more recent studies report a statistically significant (p<0.”
BackgroundCoronary artery pathophysiology after radiofrequency catheter ablation: Review and perspectives
Castaño, A., Crawford, T., Yamazaki, M., Avula, U. M. R., & Kalifa, J. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.07.006 · Cited by 65
Calvo, N., Bisbal, F., Guiu, E., Ramos, P., Nadal, M., Tolosana, J. M., Arbelo, E., Berruezo, A., Sitges, M., Brugada, J., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.07.017 · Cited by 64
“27% of cases, in accordance with complication rates reported in the literature [36].”
ResultAldaas, O. M., Malladi, C., Han, F. T., Hoffmayer, K. S., Krummen, D. E., Ho, G., Raissi, F., Birgersdotter-Green, U. M., Feld, G. K., & Hsu, J. C. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01660-3 · Cited by 64
Abdulhak, A. A. B., Khan, A. R., Tleyjeh, I. M., Spertus, J. A., Sanders, S. U., Steigerwalt, K. E., Garbati, M. A., Bahmaid, R. A., & Wimmer, A. P. (2013) · EP Europace · doi:10.1093/europace/eut239 · Cited by 64
Chierchia, G., Capulzini, L., Droogmans, S., Sorgente, A., Sarkozy, A., Muller-Burri, A., Paparella, G., de Asmundis, C., Yazaki, Y., Kerkhove, D., et al. (2010) · EP Europace · doi:10.1093/europace/eup422 · Cited by 64
Long-term follow-up after radiofrequency catheter ablation for atrial fibrillation
Katritsis, D. G., Wood, M. A., Giazitzoglou, E., Shepard, R. K., Kourlaba, G., & Ellenbogen, K. A. (2008) · EP Europace · doi:10.1093/europace/eun018 · Cited by 64
Fassini, G. M., Conti, S., Moltrasio, M., Maltagliati, A. C., Tundo, F., Riva, S. I., Russo, A. D., Casella, M., Majocchi, B., Zucchetti, M., et al. (2016) · EP Europace · doi:10.1093/europace/euw007 · Cited by 64
A Prospective Randomized Trial of Apixaban Dosing During Atrial Fibrillation Ablation
Reynolds, M. R., Allison, J. S., Natale, A., Weisberg, I., Ellenbogen, K. A., Richards, M., Hsieh, W.-H., Sutherland, J., & Cannon, C. P. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.11.005 · Cited by 64
Grecu, M., Blomström‐Lundqvist, C., Kautzner, J., Laroche, C., Gelder, I. C. V., Jordaens, L. J. L. M., Tavazzi, L., Cihak, R. J., Campal, J. M. R., Kalarus, Z. F., et al. (2019) · EP Europace · doi:10.1093/europace/euz225 · Cited by 64
Thomas, M., Wu, L., & Win, K. (2014) · Journal of Biomedical Research · doi:10.7555/jbr.28.20130191 · Cited by 68
“A worldwide survey recently documented the most frequent serious complications associated with catheter ablation as tamponade (the most common cause of death), esophageal-atrial fistula, and embolic stroke([266]).”
BackgroundMugnai, G., de Asmundis, C., Ciconte, G., Irfan, G., Saitoh, Y., Velagić, V., Ströker, E., Wauters, K., Hünük, B., Brugada, P., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.04.001 · Cited by 63
Arbelo, E., Guiu, E., Ramos, P., Bisbal, F., Borràs, R., Andreu, D., Tolosana, J. M., Berruezo, A., Brugada, J., & Mont, L. (2014) · Journal of the American Heart Association · doi:10.1161/jaha.114.000877 · Cited by 63
Chao, T., Cheng, C., Lin, W., Tsao, H.-M., Lin, Y., Chang, S., Lo, L., Hu, Y., Tuan, T., Suenari, K., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.03.016 · Cited by 63
Kuwahara, T., Takahashi, A., Okubo, K., Takagi, K., Yamao, K., Nakashima, E., Kawaguchi, N., Takigawa, M., Watari, Y., Sugiyama, T., et al. (2014) · EP Europace · doi:10.1093/europace/eut368 · Cited by 63
Metabolic Syndrome and Risk of Recurrence of Atrial Fibrillation After Catheter Ablation
Tang, R., Dong, J.-Z., Liu, X.-P., LONG, D., Yu, R.-H., Kalifa, J., & Ma, C.-S. (2009) · Circulation Journal · doi:10.1253/circj.cj-08-0832 · Cited by 62
Taclas, J. E., Nezafat, R., Wylie, J. V., Josephson, M. E., Hsing, J. M., Manning, W. J., & Peters, D. C. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.12.007 · Cited by 63
Accurate modeling and positioning of a magnetically controlled catheter tip
Le, V. N. T., Nguyen, N. H., Alameh, K., Weerasooriya, R., & Pratten, P. (2016) · Medical Physics · doi:10.1118/1.4939228 · Cited by 63
Consensus document on antithrombotic therapy in the setting of electrophysiological procedures
Blanc, J. J., Almendral, J. M., Brignole, M., Fatemi, M., Gjesdal, K., González‐Torrecilla, E., Kułakowski, P., Lip, G. Y. H., Shah, D. C., & Wolpert, C. (2008) · EP Europace · doi:10.1093/europace/eun104 · Cited by 63
High-power, low-flow, short-ablation duration—the key to avoid collateral injury?
Ali‐Ahmed, F., Goyal, V., Patel, M., Orelaru, F., Haines, D. E., & Wong, W. S. (2018) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-018-0473-5 · Cited by 63
Multiple flavonoid-binding sites within multidrug resistance protein MRP1
Chang, X. B., Maitrejean, M., Barron, D., Riordan, J. R., Trompier, D., Baubichon-Cortay, H., & Pietro, A. D. (2003) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-003-3177-6 · Cited by 63
Dillier, R., Ammar, S., Hessling, G., Kaess, B. M., Pavaci, H., Buiatti, A., Semmler, V., Kathan, S., Hofmann, M., Lennerz, C., et al. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001586 · Cited by 62
Hunter, R. J., Berriman, T., Diab, I. G., Baker, V., Finlay, M., Richmond, L., Duncan, E. R., Kamdar, R., Thomas, G., Abrams, D. J., et al. (2010) · Heart · doi:10.1136/hrt.2009.188128 · Cited by 62
Rationale and current perspective for early rhythm control therapy in atrial fibrillation
Gelder, I. C. V., Haegeli, L., Brandes, A., Heidbüchel, H., Aliot, E., Kautzner, J., Szumowski, Ł. J., Mont, L., Morgan, J. M., Willems, S., et al. (2011) · EP Europace · doi:10.1093/europace/eur192 · Cited by 61
“Feared complications include tamponade, stroke, pulmonary vein stenosis, permanent diaphragmatic paralysis, and oesophageal fistula.(60) Repeat procedures, however, are necessary in up to 40% of all patients.”
BackgroundBourland, J. D. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-24098-7.00006-x · Cited by 63
Damiano, R. J., Badhwar, V., Acker, M. A., Veeragandham, R. S., Kress, D. C., Robertson, J. O., & Sundt, T. M. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.10.004 · Cited by 61
Epidemiology of atrial fibrillation
Albert, C. M. (2009) · Swiss Medical Weekly · doi:10.4414/smw.2009.12500 · Cited by 61
Guideline for the surgical treatment of atrial fibrillation
Dunning, J., Nagendran, M., Alfieri, O., Elia, S., Kappetein, A. P., Lockowandt, U., Sarris, G. E., Kolh, P. H., Maruthappu, M., Nicholas, S., et al. (2013) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt413 · Cited by 61
“ternative, although its variable efficacy has prompted some to suggest that it may be most appropriate for selected groups of patients such as those with paroxysmal AF [4].”
BackgroundAblation of Atrial Fibrillation
Link, M. S., Haı̈ssaguerre, M., & Natale, A. (2016) · Circulation · doi:10.1161/circulationaha.116.021727 · Cited by 64
Relationship Between Catheter Stability and 12-Month Success After Pulmonary Vein Isolation
Reddy, V. Y., Pollak, S. J., Lindsay, B. D., McElderry, H. T., Natale, A., Kantipudi, C., MANSOUR, M. C., Melby, D. P., Lakkireddy, D., Levy, T., et al. (2016) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.07.014 · Cited by 61
Toupin, S., Bour, P., Lepetit‐Coiffé, M., Ozenne, V., de Senneville, B. D., Schneider, R., Vaussy, A., Chaumeil, A., Cochet, H., Sacher, F., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0323-0 · Cited by 61
“On the other hand, an excessive temperature exposure may translate into collateral extra cardiac damages in organs such as lungs, bronchi, phrenic nerves or esophagus [4].”
BackgroundCerebral safety after pulsed field ablation for paroxysmal atrial fibrillation
Reinsch, N., Füting, A., Höwel, D., Bell, J., Lin, Y., & Neven, K. G. E. J. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.06.018 · Cited by 60
Persistent iatrogenic atrial septal defect after pulmonary vein isolation
Rillig, A., Meyerfeldt, U., Birkemeyer, R., Treusch, F., Kunze, M., & Jung, W. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9257-7 · Cited by 61
“Despite ongoing improvement of ablation skills and success rates in PVI, several complications have been reported in the past including pulmonary vein stenosis, atriooesophageal fistula, phrenic nerve injury, atrial tachycardia and thromboembolic complications such as stroke [ 8 ].”
BackgroundSalinet, J. L., Tuan, J., Sandilands, A., Stafford, P. J., Schlindwein, F. S., & Ng, G. A. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12331 · Cited by 60
Ammar, S., Hessling, G., Reents, T., Fichtner, S., Wu, J., Zhu, P., Kathan, S., Estner, H., Jilek, C., Kolb, C., et al. (2011) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.963256 · Cited by 60
Dodson, J. A., Neilan, T. G., Shah, R. V., Farhad, H., Blankstein, R., Steigner, M. L., Michaud, G. F., John, R. M., Abbasi, S. A., Jerosch‐Herold, M., et al. (2014) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.113.001472 · Cited by 60
“Identifying novel markers that predict recurrent AF after PVI may help physicians and patients better make informed decisions about the expected success rate of a procedure that carries an expected complication rate of 5%.(2,7) It has been hypothesized that one of the key underlying mechanisms involved in the occurren…”
Camm, A. J., Savelieva, I., Ho, S. Y., Lindsay, B. D., Nattel, S., & Shinagawa, K. (2009) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00044-2 · Cited by 60
La Meir, M., Gelsomino, S., Lorusso, R., Lucà, F., Pison, L., Parise, O., Wellens, F., Gensini, G. F., & Maessen, J. (2012) · Journal of Cardiothoracic Surgery · doi:10.1186/1749-8090-7-71 · Cited by 59
“This approach might still be considered a possible alternative to PCA in selected patients with paroxysmal lone atrial fibrillation and impaired pulmonary function referred to surgery when the LAA excision/ligation is not deemed necessary.”
BackgroundInfluentialLiu, Z., Finet, J. E., Wolfram, J. A., Anderson, M. E., Ai, X., & Donahue, J. K. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.01.013 · Cited by 60
“A total of 35 Yorkshire pigs were divided into 3 groups: (1) 7-day sinus rhythm (SR); (2) 7-day AF; and (3) 14-day AF.”
MethodBode, F., Blanck, O., Gebhard, M., Hunold, P., Großherr, M., Brandt, S., Vonthein, R., Thiele, H., Dunst, J., & Rades, D. (2015) · EP Europace · doi:10.1093/europace/euu406 · Cited by 59
Abhishek, F., Heist, E. K., Barrett, C. D., Danik, S. B., Blendea, D. C., Correnti, C. M., Khan, Z. U., Ruskin, J. N., & MANSOUR, M. C. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9539-8 · Cited by 59
“(AV fistulae). In the worldwide survey from 777 centers on catheter ablation of AF published in 2005 by Cappato et al., the reported incidence of femoral pseudoaneurysm and AV fistula was 0.53% and 0.42%, respectively [ 3 ].”
BackgroundInfluentialWieczorek, M., Hoeltgen, R., Akin, E., Salili, A. R., Oral, H., & Morady, F. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01640.x · Cited by 59
“of RF applications 24 ± 9 [10–46] Mean no.”
BackgroundKonduru, S. V., Cheema, A., Jones, P. G., Li, Y., Ramza, B. M., & Wimmer, A. P. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9719-9 · Cited by 59
“Although there has been variability in the use of antiplatelet and anticoagulation agents, the general trend has been towards more continuous and higher levels of anticoagulation [1–6].”
BackgroundAtrial Fibrillation Ablation in Patients with Therapeutic International Normalized Ratios
Schmidt, M. U., Segerson, N. M., Marschang, H., AKOUM, N. W., Rittger, H., Clifford, S., Brachmann, J., Daccarett, M., & MARROUCHE, N. F. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02429.x · Cited by 59
Chun, K. R. J., Brugada, J., Elvan, A., Gellér, L., Busch, M., Barrera, A., SCHILLING, R. J., Reynolds, M. R., Hokanson, R. B., Holbrook, R., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006043 · Cited by 59
Acquired Pulmonary Vein Stenosis After Radiofrequency Ablation for Atrial Fibrillation
Schoene, K., Arya, A., Jahnke, C., Paetsch, I., Nedios, S., Hilbert, S., Bollmann, A., Hindricks, G., & Sommer, P. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.05.016 · Cited by 59
Tanaka‐Esposito, C., Chung, M. K., Abraham, J. M., Cantillon, D. J., Abi‐Saleh, B., & TCHOU, P. J. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9796-4 · Cited by 58
Jesel, L., Abbas, M., Toti, F., Cohen, A. A., Arentz, T., & Morel, O. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.03.031 · Cited by 58
“In our experience, the extent of tissue damage and the subsequent prothrombotic state induced by RF appeared to be similar to that observed after cryoablation [60] in terms of thromboembolic complications [62].”
BackgroundMALCOLME‐LAWES, L. C., Lim, P. B., Wright, I., Kojodjojo, P., Koa‐Wing, M., Jamil‐Copley, S., Dehbi, H., Francis, D. P., Davies, D. W., Peters, N. S., et al. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000193 · Cited by 58
Sobolev, M., Shiloh, A. L., Biase, L. D., & Slovut, D. P. (2016) · EP Europace · doi:10.1093/europace/euw113 · Cited by 58
“Bleeding complications, the need for transfusions, and surgical intervention associated with vascular access have been related to prolonged hospital length of stay, increased morbidity, and increased mortality.(4)”
BackgroundInfluentialBiase, L. D., Briceno, D. F., Trivedi, C. G., Mohanty, S., Gianni, C., Burkhardt, J. D., Mohanty, P. K., Bai, R., Gunda, S., Horton, R., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.024 · Cited by 57
Pokushalov, E. A., Romanov, A. B., CORBUCCI, G., Байрамова, С. А., Losik, D., Туров, А. Н., Shirokova, N., Karaskov, A. M., Mittal, S., & Steinberg, J. S. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.03.047 · Cited by 57
“Catheter ablation of AF is an effective therapy for treating AF-related symptoms and preventing arrhythmia recurrences.(9,10) However, symptoms cannot be used as a surrogate of AF recurrences or as a surrogate of AF burden, especially after ablation.”
BackgroundKornej, J., Hindricks, G., Kosiuk, J., Arya, A., Sommer, P., Husser, D., Rolf, S., Richter, S., Piorkowski, C., Gaspar, T., et al. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000869 · Cited by 57
Catheter Ablation to Maintain Sinus Rhythm
Calkins, H. G. (2012) · Circulation · doi:10.1161/circulationaha.111.019943 · Cited by 57
Cesare, E. D., Carbone, I., Carriero, A., Centonze, M., COBELLI, F. D., Rosa, R. D., Renzi, P. D., Esposito, A., Faletti, R., Fattori, R., et al. (2012) · La radiologia medica · doi:10.1007/s11547-012-0814-x · Cited by 56
Pulmonary Vein Re-Isolation as a Routine Strategy Regardless of Symptoms
Das, M., Wynn, G. J., Saeed, Y., Gomes, S., Morgan, M., Ronayne, C., Bonnett, L. J., Waktare, J. E. P., TODD, D. M., Hall, M. C. S., et al. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.01.016 · Cited by 57
“While clinical success rates have remained relatively static, the safety of AF ablation has improved significantly over recent years (16,17).”
BackgroundQuinidine—A legacy within the modern era of antiarrhythmic therapy
Serdoz, L. V., Rittger, H., Furlanello, F., & Bastian, D. (2019) · Pharmacological Research · doi:10.1016/j.phrs.2019.04.028 · Cited by 57
McLellan, A. J. A., Ling, L.-H., Azzopardi, S., Lee, G. A., Lee, G., Kumar, S., Wong, M. C. G., Walters, T. E., Lee, J. M., Looi, K.-L., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv139 · Cited by 56
“3 procedures in patients with paroxysmal AF undergoing catheter ablation.(4) Despite advances in catheter ablation technology, imaging and operator experience PV reconnection remains the ‘achilles heel’ of PV isolation (PVI).”
BackgroundWang, X., Li, Z., Mao, J., & He, B. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.05.022 · Cited by 56
“The requirement of repeated procedures and concern of safety [15,16] became the major pitfalls of SA approach.”
BackgroundEvolving Contemporary Management of Atrial Fibrillation in Hypertrophic Cardiomyopathy
Rowin, E. J., Link, M. S., Maron, M. S., & Maron, B. J. (2023) · Circulation · doi:10.1161/circulationaha.123.065037 · Cited by 61
JCS/JHRS 2024 Guideline Focused Update on Management of Cardiac Arrhythmias
Iwasaki, Y., Noda, T., Akao, M., Fujino, T., Hirano, T., Inoue, K., KUSANO, K. F., Nagai, T., Satomi, K., Shinohara, T., et al. (2025) · Circulation Journal · doi:10.1253/circj.cj-24-0073 · Cited by 57
Kang, K., Kim, T., PARK, J., Uhm, J., Joung, B., Hwang, C., Lee, M., & Pak, H. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12398 · Cited by 56
“875 Diabetes mellitus, n (%) 22 (15) 16 (14) 6 (18) 0.”
Pokushalov, E. A., Romanov, A. B., Николаевич, А. С., Викторовна, Б. В., Losik, D., Байрамова, С. А., Karaskov, A. M., Mittal, S., & Steinberg, J. S. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12038 · Cited by 56
The Convergent Procedure: A Multidisciplinary Atrial Fibrillation Treatment
Kiser, A. C., Landers, M., Horton, R., Hume, A., Natale, A., & Geršak, B. (2010) · The Heart Surgery Forum · doi:10.1532/hsf98.20091112 · Cited by 57
Lehmann, H. I., Richter, D., Prokesch, H., Graeff, C., Prall, M., Simoniello, P., Fournier, C., Bauer, J., Kaderka, R., Weymann, A., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.002436 · Cited by 56
“Catheter ablation requires extensive training, can be tedious, and also carries risk of several complications, such as thrombembolic events, pulmonary vein stenosis, and often letal atrial-esophageal fistula formations.(1) Invasive delivery of β-irradiation to distinct arrhythmogenic cardiac locations has demonstrated…”
BackgroundChen, J., Yang, Z., Xu, H., Shi, K., Long, Q., & Guo, Y. (2016) · European Radiology · doi:10.1007/s00330-016-4411-6 · Cited by 56
Adiyaman, A., Buist, T. J., Beukema, R. J., Smit, J. J. J., Delnoy, P. P. H. M., Hemels, M. E. W., Sie, H. T., Misier, A. R. R., & Elvan, A. (2018) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006182 · Cited by 56
Chun, K. R. J., Okumura, K., Scazzuso, F., On, Y. K., Kueffer, F. J., Braegelmann, K. M., Khelae, S. K., Al‐Kandari, F., Földesi, C., & the Cryo Global Registry Investigators (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12504 · Cited by 55
“Finally, one procedurerelated death was reported in this registry (0.03%), which indicates the improved safety of AF ablation since the Cappato et al 2010 survey, which reported 0.15% AF procedure-related deaths.16 This dataset of nearly 3000 patients treated according to standard of care by 239…”
ResultInfluentialWynn, G. J., Haq, I. J., Hung, J., Bonnett, L. J., Lewis, G. A., Webber, M. R., Waktare, J. E. P., Modi, S. S., SNOWDON, R. L., Hall, M. C. S., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12404 · Cited by 55
Tschabrunn, C. M., Silverstein, J. R., Berzin, T. M., Ellis, E., Buxton, A. E., Josephson, M. E., & Anter, E. (2015) · EP Europace · doi:10.1093/europace/euu356 · Cited by 55
“04%.(2,3) Although the pathophysiology is not entirely understood, it is clear that thermal injury to the oesophagus during ablation of the posterior left atrial wall plays a crucial role in triggering a cascade of events that eventually results in the development of AEF.”
BackgroundYamaji, H., Murakami, T., Hina, K., Higashiya, S., Kawamura, H., Murakami, M., Kamikawa, S., Hirohata, S., & Kusachi, S. (2013) · Clinical Drug Investigation · doi:10.1007/s40261-013-0081-1 · Cited by 55
“AF ablation is one of the most complex interventional electrophysiological procedures and is thus associated with several complications [8, 9].”
BackgroundTang, R. B., Dong, J., Zhang, Z. Q., Li, Z. A., Liu, X. P., Kang, J. P., Yu, R. H., Long, D., & Sheng, C. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9243-0 · Cited by 55
“As stroke is a major potential complication of catheter manipulation in the setting of LA/LAA thrombus [ 6 ], it is imperative that such thrombi be detected prior to attempting catheter ablation procedures.”
BackgroundEvonich, R. F., Nori, D. M., & Haines, D. E. (2007) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-007-9142-9 · Cited by 55
Pokushalov, E. A., Romanov, A. B., Melis, M. D., Николаевич, А. С., Викторовна, Б. В., Losik, D., Байрамова, С. А., Karaskov, A. M., Mittal, S., & Steinberg, J. S. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000495 · Cited by 55
“The single-procedure success rate of catheter ablation is ≈60%, and performing additional ablation procedures and adding AAD therapy can increase the success rate to ≈75%.(10,11) When the first ablation fails and the patient has AF recurrences, the physician must choose the optimal treatment to halt or minimize AF pro…”
BackgroundTops, L. F., Schalij, M. J., & Bax, J. J. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq005 · Cited by 55
Wudel, J. H., Chaudhuri, P., & Hiller, J. J. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.08.014 · Cited by 55
Metadata
- Authors
- Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., Skanes, A., Ambrogi, F., & Biganzoli, E.
- Affiliations
- The Royal Melbourne Hospital (AU)
- ORCID
- Venue
- Circulation Arrhythmia and Electrophysiology
- Published
- 2010-02
- Volume
- 3
- Issue
- 1
- Pages
- 32-38
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2146673314
- Cited by
- 2,852
- References
- 34
- Citations by year
- 2026: 26 · 2025: 42 · 2024: 51 · 2023: 68 · 2022: 81 · 2021: 110 · 2020: 126 · 2019: 125 · 2018: 141 · 2017: 177 · 2016: 199 · 2015: 184 · 2014: 220 · 2013: 246 · 2012: 218
- FWCI
- 156.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation Arrhythmia and Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- catheter ablation, atrial fibrillation, paroxysmal atrial fibrillation, persistent atrial fibrillation, ablation efficacy, ablation safety, procedural complications, CARTO system
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Anticoagulants, Atrial Fibrillation, Data Collection, Female, Humans, Male, Middle Aged, Surveys and Questionnaires, Treatment Outcome, Catheter Ablation, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review