The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation
Abstract
BACKGROUND: The purpose of this study was to provide an updated worldwide report on the methods, efficacy, and safety of catheter ablation of atrial fibrillation (AF). METHODS AND RESULTS: A questionnaire with 46 questions was sent to 521 centers from 24 countries in 4 continents. Complete interviews were collected from 182 centers, of which 85 reported to have performed 20,825 catheter ablation procedures on 16,309 patients with AF between 2003 and 2006. The median number of procedures per center was 245 (range, 2 to 2715). All centers included paroxysmal AF, 85.9% also included persistent and 47.1% also included long-lasting AF. Carto-guided left atrial circumferential ablation (48.2% of patients) and Lasso-guided ostial electric disconnection (27.4%) were the most commonly used techniques. Efficacy data were analyzed with centers representing the unit of analysis. Of 16,309 patients with full disclosure of outcome data, 10 488 (median, 70.0%; interquartile range, 57.7% to 75.4%) became asymptomatic without antiarrhythmic drugs and another 2047 (10.0%; 0.5% to 17.1%) became asymptomatic in the presence of previously ineffective antiarrhythmic drugs over 18 (range, 3 to 24) months of follow-up. Success rates free of antiarrhythmic drugs and overall success rates were significantly larger in 9590 patients with paroxysmal AF (74.9% and 83.2%) than in 2800 patients with persistent AF (64.8% and 75.0%) and 1108 patients with long-lasting AF (63.1% and 72.3%) (P<0.0001). Major complications were reported in 741 patients (4.5%). CONCLUSIONS: When analyzed in a large number of electrophysiology laboratories worldwide, catheter ablation of AF shows to be effective in approximately 80% of patients after 1.3 procedures per patient, with approximately 70% of them not requiring further antiarrhythmic drugs during intermediate follow-up.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In patients who experience symptomatic recurrences of AF despite antiarrhythmic drug therapy, all RCTs showed better sinus rhythm maintenance with catheter ablation than on antiarrhythmic drugs.586,713,727,728”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [727]
In the citing paper
“Five to seven per cent of patients will suffer severe complications after catheter ablation of AF, and 2-3% will experience life-threatening but usually manageable complications.727,[748][749][750]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [727]
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Nademanee, K., McKenzie, J. P., Kosar, E. M., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,004
Calkins, H. G., Brugada, J., Packer, D. L., Cappato, R., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Haines, D. E., Haı̈ssaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,690
Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary Veins
Chen, S., HSIEH, M., TAI, C., Tsai, C.-F., Prakash, V. S., Yu, W., Hsu, T., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,442
Cappato, R., Calkins, H. G., Chen, S., Davies, W. D., Iesaka, Y., Kalman, J. M., Kim, Y.-H., Klein, G. J., Packer, D. L., & Skanes, A. C. (2005) · Circulation · doi:10.1161/01.cir.0000157153.30978.67 · Cited by 1,303
A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jaı̈s, P., Haı̈ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Clémenty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,114
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S. A., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Circumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation
Oral, H., Pappone, C., Chugh, A., Good, E. D., Bogun, F. M., Pelosi, F., Bates, E., Lehmann, M. H., Vicedomini, G., Augello, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa050955 · Cited by 975
Haı̈ssaguerre, M., Jaı̈s, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R. P., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 921
Catheter Ablation for Paroxysmal Atrial Fibrillation
Oral, H., Scharf, C., Chugh, A., HALL, B. W., Cheung, P. W., Good, E. D., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Cited by
Sorted by citations
Items 701–800 of 1,003
Arshad, A., Johnson, C. K., Mittal, S., Buch, E. F., Hamam, I. R. T., Tran, T., Shaw, R. E., Musat, D. L., Preminger, M. W., Sichrovsky, T., et al. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12401 · Cited by 36
O'Neill, M. D., Jaı̈s, P., Derval, N., Hocini, M., & Haı̈ssaguerre, M. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00973.x · Cited by 36
Kriatselis, C., Tang, M., Nedios, S., Roser, M., Gerds-Li, H., & Fleck, E. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.02.037 · Cited by 36
Scaglione, M., Caponi, D., Anselmino, M., CLEMENTE, F. D., Blandino, A., Ferraris, F., Donna, P. D., Ebrille, E., Halimi, F., Leclercq, J. F., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12500 · Cited by 36
Muneretto, C., Bisleri, G., Bontempi, L., Cheema, F. H., & Curnis, A. (2012) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e31826f0462 · Cited by 36
Thai, W.-E., Wai, B., Lin, K. Y., Cheng, T., Heist, E. K., Hoffmann, U., Singh, J. P., & Truong, Q. A. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.968313 · Cited by 36
“repeat procedures are often necessary.(14,15) Hence, minimizing CT radiation dose remains a priority because patients may be further exposed to ionizing radiation during postprocedural follow-up scans and need for repeat ablation procedures, which includes reimaging the PV anatomy beforehand.”
BackgroundKim, J. S., Jongnarangsin, K., Latchamsetty, R., Chugh, A., Ghanbari, H., Crawford, T., Yokokawa, M., Good, E. D., Bogun, F. M., Pelosi, F., et al. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.000143 · Cited by 36
“Then the goodness-of-fit of the data across different polynomial logistic regression models were assessed using the Akaike Information Criterion under (1) the null model (β=0, γ=0), (2) the linear model (γ=0), (3) the quadratic model, and (4) the cubic model with the additional parameter, X(3).”
BackgroundMethodMurakawa, Y., Nogami, A., Shoda, M., Inoue, K., Naito, S., Kumagai, K., Miyauchi, Y., Yamane, T., Morita, N., Okumura, K., et al. (2014) · Circulation Journal · doi:10.1253/circj.cj-14-0099 · Cited by 36
“atrioesophageal fistula, gastric hypomotility, and phrenic nerve paralysis, differs from that associated with other catheter ablation procedures [15], and their incidence in Japan remains to be elucidated.”
BackgroundGastrointestinal complications associated with catheter ablation for atrial fibrillation
Garg, L., Garg, J., Gupta, N., Shah, N. N., Krishnamoorthy, P. M., Palaniswamy, C., Bozorgnia, B., & Natale, A. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.09.069 · Cited by 36
Sharma, S. P., Sangha, R. S., Dahal, K. B., & Krishnamoorthy, P. M. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-016-0198-2 · Cited by 36
“1 % during SVCI in previous studies [13, 26].”
ResultFemoral vascular complications following catheter ablation of atrial fibrillation
Prudente, L. A., Moorman, J. R., Lake, D. E., Xiao, Y., Greebaum, H., Mangrum, J. M., Dimarco, J., & Ferguson, J. (2009) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-009-9402-y · Cited by 36
“Left atrial catheter ablation is increasingly used to treat patients with symptomatic atrial fibrillation (AF) who have failed antiarrhythmic drug therapy [ 1 ].”
BackgroundBingen, B. O., Neshati, Z., Askar, S. F. A., Kazbanov, I. V., Ypey, D. L., Panfilov, A. V., Schalij, M. J., de Vries, A. A. F., & Pijnappels, D. A. (2013) · Circulation · doi:10.1161/circulationaha.113.005019 · Cited by 36
Finlay, M., Hunter, R. J., Baker, V., Richmond, L., Goromonzi, F., Thomas, G., Rajappan, K., Duncan, E. R., Tayebjee, M. H., Dhinoja, M., et al. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9632-7 · Cited by 35
“Technological developments appear to have reduced X-ray doses and may help newer centres establish an AF ablation programme [2].”
Mapping and Isolation of the Pulmonary Veins Using the PVAC Catheter
Duytschaever, M. F., Anné, W., Papiashvili, G., Vandekerckhove, Y. R., & Tavernier, R. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02609.x · Cited by 35
Linhart, M., Lewalter, T., Mittmann-Braun, E. L., Karbach, N. C., Andrié, R., Hammerstingl, C., Fimmers, R., Kreuz, J., Nickenig, G., SCHRICKEL, J. W., et al. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9803-9 · Cited by 35
“Reported long-term single procedure success rates for maintained sinus rhythm (SR) vary widely, ranging from less than 40 % to more than 70 % [3–5].”
BackgroundWadehra, V., Buxton, A. E., Antoniadis, A. P., McCready, J. W., Redpath, C. J., Segal, O. R., Rowland, E., LOWE, M. D., Lambiase, P. D., & CHOW, A. W. C. (2011) · EP Europace · doi:10.1093/europace/eur155 · Cited by 35
Holmqvist, F., Simon, D. N., Steinberg, B. A., Hong, S. J., Kowey, P. R., Reiffel, J. A., Naccarelli, G. V., Chang, P., Gersh, B. J., Peterson, E. D., et al. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.001901 · Cited by 35
“, catheter ablation of atrial fibrillation (AF) by electrically isolating the pulmonary veins has evolved over the past 15 years and is now a commonly performed procedure in many major centers throughout the world.(1,2) Small, randomized, clinical trials have demonstrated that catheter ablation results in increased fr…”
BackgroundPersonalized Models of Human Atrial Electrophysiology Derived From Endocardial Electrograms
Corrado, C., Whitaker, J., Chubb, H., Williams, S. E., Wright, M. J., Gill, J. S., O'Neill, M. D., & Niederer, S. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2574619 · Cited by 34
“However, many patients require multiple procedures to achieve sinus rhythm [5].”
BackgroundRolf, S., Sommer, P., Gaspar, T., John, S., Arya, A., Hindricks, G., & Piorkowski, C. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.971705 · Cited by 35
Hamaya, R., Miyazaki, S., Taniguchi, H., Kusa, S., Nakamura, H., Hachiya, H., Kajiyama, T., Watanabe, T., Igarashi, M., Hirao, K., et al. (2017) · EP Europace · doi:10.1093/europace/eux307 · Cited by 35
Insights into ablation of persistent atrial fibrillation: Lessons from 6‐year clinical outcomes
Brooks, S., Metzner, A., Wohlmuth, P., Lin, T., Wißner, E., Tilz, R. R., Rillig, A., Mathew, S., Saguner, A. M., Heeger, C.-H. H., et al. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13401 · Cited by 35
Kadado, A. J., Akar, J. G., & Hummel, J. P. (2018) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2018.09.010 · Cited by 35
Sex differences in rate and rhythm control for atrial fibrillation
Weberndörfer, V., Beinart, R., Ricciardi, D., Ector, J., Mahfoud, M., Széplaki, G., Hemels, M. E. W., & 2017/2018, D.-C. P. (2018) · EP Europace · doi:10.1093/europace/euy295 · Cited by 35
Safety, Feasibility and Economic Impact of Same-Day Discharge Following Atrial Fibrillation Ablation
Reddy, S. A., Nethercott, S. L., Chattopadhyay, R. K., Heck, P. M., & Virdee, M. S. (2020) · Heart Lung and Circulation · doi:10.1016/j.hlc.2020.02.016 · Cited by 35
Yu, S., Zhao, Q., Wu, P., Qin, M., Huang, H., Cui, H., & Huang, C. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02436.x · Cited by 35
Lee, K., Yeh, H.-Y., Tung, C.-P., Chu, C.-S., Cheng, K., Tsai, W., Lu, Y., Chang, J., Sheu, S., & Lai, W. (2010) · Cardiology · doi:10.1159/000318172 · Cited by 35
Maguire, P. J., Gardner, E. A., Jack, A., Zei, P. C., Al‐Ahmad, A., Fajardo, L. F., Ladich, E. R., & TAKEDA, P. A. (2011) · Cureus · doi:10.7759/cureus.32 · Cited by 35
“5-5%, can range from vascular complication to stroke, cardiac perforation, and tamponade [8, 9].”
How to recognize, manage, and prevent complications during atrial fibrillation ablation
Dixit, S., & Marchlinski, F. E. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.10.034 · Cited by 35
Apixaban, Rivaroxaban, and Dabigatran in Patients Undergoing Atrial Fibrillation Ablation
Rillig, A., Lin, T., PLESMAN, J., Heeger, C.-H. H., Lemeš, C., Metzner, A., Mathew, S., Wißner, E., Wohlmuth, P., Ouyang, F. O., et al. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12856 · Cited by 34
Six-Year Follow-up of Catheter Ablation in Paroxysmal Atrial Fibrillation
Uchiyama, T., Miyazaki, S., Taniguchi, H., Komatsu, Y., Kusa, S., Nakamura, H., Hachiya, H., & Iesaka, Y. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0468 · Cited by 34
Cryoballoon Ablation for Atrial Fibrillation
Andrade, J. G., Dubuc, M., Guerra, P. G., Macle, L., Rivard, L., Roy, D., Talajic, M. R., Thibault, B., & Khairy, P. (2012) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30479-x · Cited by 34
“The rate of acute procedural complications reported with cryoballoon-based ablation (CBA) is relatively low (<3-5%) and compares favourably with irrigated RF and duty-cycled multi-electrode RF ablation [7,9,10,21].”
BackgroundInfluentialImamura, K., Yoshida, A., Takei, A., Fukuzawa, K., Kiuchi, K., Takami, K., Takami, M., Itoh, M., Fujiwara, R., Suzuki, A., et al. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9801-y · Cited by 34
“However, the periprocedural anticoagulation protocol varies among centers [5].”
BackgroundCatheter ablation of atrial fibrillation as first-line therapy--a single-centre experience
Tanner, H., Makowski, K., Roten, L., Seiler, J., Schwick, N. G., Muller, C., Fuhrer, J., & Delacrétaz, E. (2011) · EP Europace · doi:10.1093/europace/eur065 · Cited by 34
Management of Atrio-Esophageal Fistula Following Left Atrial Ablation
Yousuf, T., Keshmiri, H., Bulwa, Z. B., Kramer, J. B., Arshad, H. M. S., Issa, R., Woznicka, D., Gordon, P. J., & Abi‐Mansour, P. (2016) · Cardiology Research · doi:10.14740/cr454e · Cited by 34
“The indications and application of left atrial ablation in the treatment of AF have progressively expanded in the past decade [1, 2].”
BackgroundNakamura, K., Naito, S., Sasaki, T., Minami, K., Take, Y., Goto, E., Shimizu, S., Yamaguchi, Y., Suzuki, N., Yano, T., et al. (2016) · Circulation Journal · doi:10.1253/circj.cj-15-1368 · Cited by 34
“signals averaged [NSA], 2); (2) fluid-attenuated inversion recovery (FLAIR) sequence (TR/TE, 8,000/100 ms; inversion time, 2,300 ms; matrix, 288×157; FOV, 240×190 mm; slice thickness/gap, 5.”
El‐Chami, M. F., Kowal, R. C., Soejima, K., Ritter, P., Duray, G. Z., Neužil, P., Mont, L., Kypta, A., Sagi, V. S., Hudnall, J. H., et al. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13094 · Cited by 34
Hsieh, Y., Chen, Y., Chien, K., Chung, F., Lo, L., Chang, S., Chao, T., Hu, Y., Lin, C., Tuan, T., et al. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.12.016 · Cited by 34
Same‐day discharge after cryoballoon ablation of atrial fibrillation: A multicenter experience
Kowalski, M., Parikh, V. K., Salcido, J. A. R., Chalfoun, N. T., Albano, A. J., O’Neill, P. G., Bowers, M. R., Gauri, A. J., Braegelmann, K. M., Lim, H. W., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14843 · Cited by 34
“30%, which is slightly higher than observed in our study.(12,13) Uninterrupted anticoagulation with warfarin or direct oral anticoagulant‐facilitated early ambulation on continued anticoagulation, may have contributed to a low risk of stroke complications.”
BackgroundResultAcute pericarditis after atrial fibrillation ablation: Incidence, characteristics, and risk factors
Nakhla, S., Mentias, A. G., Rymer, C. C., Hussein, A. A., Wazni, O. M., Rickard, J., Baranowski, B. J., Cantillon, D. J., Klein, A. L., Cremer, P. C., et al. (2022) · Heart Rhythm O2 · doi:10.1016/j.hroo.2022.02.008 · Cited by 34
“Complications, such as stroke, pulmonary vein stenosis, esophageal injury, and phrenic nerve paralysis, are rare and have also decreased.(1,2) Acute pericarditis after AF ablation has been described, although primarily through case reports and series, and a broader understanding of postablation pericarditis is lacking.”
BackgroundWinkle, R. A., Mead, R. H., Engel, G., & Patrawala, R. A. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.10.048 · Cited by 34
Pulmonary vein stenosis following catheter ablation of atrial fibrillation
rerfellner, H. P., & Martinek, M. (2005) · Current Opinion in Cardiology · doi:10.1097/01.hco.0000179816.80576.3c · Cited by 34
Datino, T., Arenal, Á., Pelliza, M., Hernández-Hernández, J., Atienza, F., González‐Torrecilla, E., Ávila, P., Bravo, L., & Fernández‐Avilés, F. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.11.030 · Cited by 34
Gillis, A. M., & Skanes, A. C. (2011) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2010.11.003 · Cited by 32
Witt, C. M., Fenstad, E. R., Cha, Y., Kane, G. C., Kushwaha, S. S., Hodge, D. O., Asirvatham, S. J., Oh, J. K., Packer, D. L., & Powell, B. D. (2014) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-014-9875-1 · Cited by 34
Kızılırmak, F., Demır, G. G., Gökdeniz, T., Güneş, H. M., Çakal, B., Güler, E., Karaca, I. O., Omaygenç, M. O., Yılmaz, F., Olgun, F. E., et al. (2016) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12364 · Cited by 34
“(3) AF recurrence after CBA was not associated with Pwd or Pdis.”
BackgroundQualitätskriterien zur Durchführung der Katheterablation von Vorhofflimmern
Kück, K., Böcker, D., Chun, K. R. J., Deneke, T., Hindricks, G., Hoffmann, E., Piorkowski, C., & Willems, S. (2017) · Der Kardiologe · doi:10.1007/s12181-017-0146-0 · Cited by 31
Dysfunction of the autonomic nervous system in atrial fibrillation.
Xi, Y. T., & Cheng, J. (2015) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2072-1439.2015.01.12 · Cited by 33
Hayashi, H., Hayashi, M., Miyauchi, Y., Takahashi, K., Uetake, S., Tsuboi, I., Yodogawa, K., Iwasaki, Y., & Shimizu, W. (2014) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-014-9894-y · Cited by 33
“Radiofrequency catheter ablation (RFCA) has emerged as a cure for AF in patients without structural heart disease [5], and several studies have also shown the effectiveness of this treatment in patients with HCM [6–9].”
BackgroundSairaku, A., Nakano, Y., Oda, N., Makita, Y., Kajihara, K., Tokuyama, T., & Kihara, Y. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9552-6 · Cited by 33
“Furthermore, vascular access complications, such as pseudoaneurysm and femoral arteriovenous fistula, have been reported as the most common complications of AF ablation [6–9].”
BackgroundMaat, G. E. D., Gelder, I. C. V., Rienstra, M., Quast, A. B. E., Tan, E. S., Wiesfeld, A. C. P., Pozzoli, A., & Mariani, M. A. (2013) · EP Europace · doi:10.1093/europace/eut208 · Cited by 33
Fink, T., Metzner, A., Willems, S., Eckardt, L., İnce, H., Brachmann, J., Spitzer, S. G., Deneke, T., Schmitt, C., Hochadel, M., et al. (2019) · Clinical Research in Cardiology · doi:10.1007/s00392-019-01471-5 · Cited by 33
Halbfaß, P., Berkovitz, A., Pavlov, B., Sonne, K., Nentwich, K., Ene, E., Hörning, F., Barth, S., Zacher, M., & Deneke, T. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14193 · Cited by 33
“6% in patients.(2,4,5) Limiting ablation time, contact force, and ablation energy at the LA posterior wall has been recommended in all AF ablations to decrease the risk of esophageal complications.”
BackgroundKupó, P., Riesz, T., Sághy, L., Vámos, M., Bencsik, G., Makai, A., Kohári, M., Benak, A., Miklós, M., & Pap, R. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15893 · Cited by 33
“The most frequent complications of these procedures are related to vascular access ranging in frequency from 1% to 13%.(5,7,8) Traditionally, femoral vein puncture is guided by palpation of the femoral artery below the inguinal ligament and the needle is inserted next to the pulsation to target the femoral vein.”
BackgroundTurco, P., Simone, A. D., Rocca, V. L., Iuliano, A., Capuano, V., Astarita, C., Napoli, T. D., Messina, V., Baldi, S., & Stabile, G. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00618.x · Cited by 33
Nakahara, S., Ramírez, R. J., Buch, E. F., Michowitz, Y., Vaseghi, M., Diego, C. D., Boyle, N. G., Mahajan, A., & Shivkumar, K. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.09.022 · Cited by 33
Lu, Z., Nie, L., He, B., Yu, L., Salim, M., Huang, B. S., Cui, B., He, W., Wu, W., & Jiang, H. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.03.014 · Cited by 33
“Radiofrequency catheter ablation to electrically isolate the pulmonary veins is widely used in the treatment of AF (Haïssaguerre et al., 1998; Cappato et al., 2010; Ouyang et al., 2010).”
Edriss, H., Denega, T., Test, V. J., & NUGENT, K. M. (2016) · Respiratory Medicine · doi:10.1016/j.rmed.2016.06.014 · Cited by 33
Mujović, N. M., Marinković, M. M., Marković, N., Kocijančić, A., Kovacevic, V., Simic, D. V., Ristić, A. D., Stankovic, G. R., Miličić, B., Putnik, S. M., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-016-0402-x · Cited by 33
“Although the CA success rates have improved, the rate of complications has remained unchanged, probably because of an increase in the number of complex procedures [1, 2].”
BackgroundCatheter Ablation Therapy for Supraventricular Arrhythmias
Marine, J. E. (2007) · JAMA · doi:10.1001/jama.298.23.2768 · Cited by 32
Catheter Ablation Therapy for Atrial Fibrillation
Marine, J. E., Dong, J., & Calkins, H. G. (2005) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2005.06.011 · Cited by 33
Surgical Treatment for Isolated Atrial Fibrillation Minimally Invasive vs Classic Cut and Sew Maze
Lee, R., McCarthy, P. M., PASSMAN, R. S., Kruse, J. T., Malaisrie, S. C., McGee, E. C., Lapin, B. R., Jacobson, J. T., Goldberger, J. J., & Knight, B. P. (2011) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e318248f3f4 · Cited by 32
The Myocardial Electrical Blockade Induced by Photosensitization Reaction
Ito, A., Hosokawa, S., Miyoshi, S., Soejima, K., Ogawa, S., & Arai, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2031315 · Cited by 32
“However, this heat generated during the treatment induces severe complications [ 28 ], [29].”
BackgroundSauren, L. D. C., Meir, M. L., Roy, L. D., Pison, L., van der Veen, F. H., Mess, W. H., Crijns, H. J. G. M., & Maessen, J. G. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.05.004 · Cited by 32
“The success rate of the ENDO PVI method in paroxysmal AF patients in this study is 90%, which is consistent with the previous studies in paroxysmal endocardial catheter approach PVI (75—95%) [2].”
BackgroundMethodResultPredictors for Progression of Atrial Fibrillation in Patients Awaiting Atrial Fibrillation Ablation
Kochhäuser, S., Dechering, D. G., Trought, K., Hache, P., Haig-Carter, T., Khaykin, Y., Wulffhart, Z. A., Pantano, A. A., Tsang, B., Eckardt, L., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.031 · Cited by 32
Yamaji, H., Murakami, T., Hina, K., Higashiya, S., Kawamura, H., Murakami, M., Kamikawa, S., Komtasubara, I., & Kusachi, S. (2016) · Clinical Drug Investigation · doi:10.1007/s40261-016-0435-6 · Cited by 32
Greenstein, E., PASSMAN, R. S., LIN, A. C., & Knight, B. P. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.968040 · Cited by 32
Latchamsetty, R., & Morady, F. (2017) · Annual Review of Medicine · doi:10.1146/annurev-med-041316-090015 · Cited by 32
Kraft, M., Büscher, A., Wiedmann, F., L’hoste, Y., Haefeli, W. E., Frey, N., Katus, H. A., & Schmidt, C. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.638445 · Cited by 31
Atrial fibrillation and female sex
Anselmino, M., Battaglia, A., Gallo, C., Gili, S., Matta, M., Castagno, D., Ferraris, F., Giustetto, C., & Gaïta, F. (2015) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000239 · Cited by 31
New drugs vs. old concepts: A fresh look at antiarrhythmics
Thireau, J., Pasquié, J., Martel, E., Guennec, J. L., & Richard, S. (2011) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2011.03.003 · Cited by 33
“Besides drug therapy to maintain the sinus rhythm, nondrug treatments such as catheter ablation show promising results (Cappato et al., 2005; Ellis et al., 2009), despite a 6–8% global complication rate with a mortality rate as high as 0.5%.”
BackgroundInfluentialAtrial fibrillation management in Asia: From the Asian expert forum on atrial fibrillation
Chiang, C., Zhang, S., Tse, H., Teo, W. S., Omar, R., & Sriratanasathavorn, C. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.12.033 · Cited by 32
“5% [69] to 6.”
Prior antiarrhythmic drug use and the outcome of atrial fibrillation ablation
Winkle, R. A., Mead, R. H., Engel, G., Kong, M. H., & Patrawala, R. A. (2012) · EP Europace · doi:10.1093/europace/eur370 · Cited by 32
Nölker, G., Gutleben, K., Muntean, B. G., Vogt, J., Horstkotte, D., Abkenari, L. D., Akca, F., & Szili‐Törok, T. (2012) · EP Europace · doi:10.1093/europace/eus169 · Cited by 32
Srivatsa, U. N., Danielsen, B. H., Anderson, I., Amsterdam, E. A., Pezeshkian, N. G., Yang, Y., & White, R. H. R. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.017 · Cited by 32
Brooks, A. G., Wilson, L., Chia, N., Lau, D. H., Alasady, M., Leong, D. P., Laborderie, J., Roberts‐Thomson, K. C., Young, G. D., Kalman, J. M., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.03.130 · Cited by 32
“In the last decade, catheter ablation procedures for atrial fibrillation (AF) have increased dramatically [1,2] and this therapy is now a well”
BackgroundSchietinger, B. J., Bozlar, U., Hagspiel, K. D., Norton, P. T., Greenbaum, H. R., Wang, H., Isbell, D. C., Patel, R. A. G., Ferguson, J., Gay, S. B., et al. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.10.008 · Cited by 32
Kim, H. J., Kim, J. S., & Kim, T. S. (2016) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivw027 · Cited by 32
Chronic Kidney Disease and Atrial Fibrillation: A Contemporary Overview.
Kulkarni, N. N., Gukathasan, N., Sartori, S., & Baber, U. (2012) · Europe PMC (PubMed Central) · doi:10.4022/jafib.448 · Cited by 32
Autofluorescence hyperspectral imaging of radiofrequency ablation lesions in porcine cardiac tissue
Gil, D. A., Swift, L., Asfour, H., Muselimyan, N., Mercader, M. A., & Sarvazyan, N. A. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201600071 · Cited by 32
Effect of Left Atrial Wall Thickness on Radiofrequency Ablation Success
INOUE, J., Skanes, A. C., Gula, L. J., & Drangova, M. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13065 · Cited by 32
How to select patients for atrial fibrillation ablation
Oral, H., & Morady, F. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.01.016 · Cited by 32
Han, S. W., Shin, S. Y., Im, S. I., Na, J. O., Choi, C. U., Kim, S. H., Kim, J. W., Kim, E. J., Rha, S., Park, C. G., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.11.041 · Cited by 31
In vivo dose measurement using TLDs and MOSFET dosimeters for cardiac radiosurgery
Gardner, E. A., Sumanaweera, T. S., Blanck, O., Iwamura, A. K., Steel, J. P., Dieterich, S., & Maguire, P. (2012) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v13i3.3745 · Cited by 31
“5%),(3) and long-term efficacy JOurnAL OF APPLIED cLInIcAL MEDIcAL PHYSIcS, VOLuME 13, nuMBEr 3, 2012”
BackgroundKuwahara, T., Takahashi, A., Takahashi, Y., KOBORI, A., Miyazaki, S., Takei, A., Fujino, T., Okubo, K., Takagi, K., Fujii, A., et al. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12069 · Cited by 31
Learning curve for ablation of atrial fibrillation in medium-volume centers
Sairaku, A., Nakano, Y., Oda, N., Makita, Y., Kajihara, K., Tokuyama, T., & Kihara, Y. (2011) · Journal of Cardiology · doi:10.1016/j.jjcc.2011.01.005 · Cited by 31
MALCOLME‐LAWES, L. C., Lim, P. B., Koa‐Wing, M., Whinnett, Z. I., Jamil‐Copley, S., Hayat, S. A., Francis, D. P., Kojodjojo, P., Davies, D. W., Peters, N. S., et al. (2012) · EP Europace · doi:10.1093/europace/eus244 · Cited by 31
Advances in Imaging for Atrial Fibrillation Ablation
D’Silva, A., & Wright, M. J. (2011) · Radiology Research and Practice · doi:10.1155/2011/714864 · Cited by 29
Nakatani, Y., Kumagai, K., Minami, K., Nakano, M., Inoue, H., & Oshima, S. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.10.020 · Cited by 31
Neuberger, H., Tilz, R. R., Bonnemeier, H., Deneke, T., Estner, H., Kriatselis, C., Kuniss, M., Luik, A., Sommer, P., Steven, D., et al. (2013) · EP Europace · doi:10.1093/europace/eut149 · Cited by 31
Catheter ablation of atrial fibrillation—patient satisfaction from a single-center UK experience
Ezzat, V., Chew, A., McCready, J. W., Lambiase, P. D., CHOW, A. W. C., LOWE, M. D., Rowland, E., & Segal, O. R. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9763-5 · Cited by 31
“The relevance of these findings should not be underestimated as ablation for AF is an increasingly common procedure [22].”
BackgroundStabile, G., Bertaglia, E., Pappone, A., Themistoclakis, S., Tondo, C., Calzolari, V., Bottoni, N., Arena, G., Rebellato, L., Greco, M. D., et al. (2014) · EP Europace · doi:10.1093/europace/euu002 · Cited by 31
Yoshimura, A., Iriki, Y., Ichiki, H., Oketani, N., Okui, H., Maenosono, R., Namino, F., Miyata, M., & Ohishi, M. (2016) · Journal of Cardiology · doi:10.1016/j.jjcc.2016.03.014 · Cited by 32
Recognizing and reacting to complications of trans-septal puncture
Salghetti, F., Sieira, J. A., Chierchia, G., Curnis, A., & de Asmundis, C. (2017) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2017.1408411 · Cited by 31
“A similar refinement, using a smaller J-shaped needle within a Brockenbrough needle has been evaluated as a bailout approach in resistant, aneurysmal or thick FO and in IAS patches [66,67,68].”
MethodVoskoboinik, A., SPARKS, P. B., Morton, J. B., Lee, G., Joseph, S., Hawson, J. J., Kistler, P. M., & Kalman, J. M. (2018) · Heart Lung and Circulation · doi:10.1016/j.hlc.2018.01.002 · Cited by 31
Challenges and limitations in the diagnosis of atrioesophageal fistula
Ha, F. J., Han, H., Sanders, P., Teh, A. W., O’Donnell, D., Farouque, O., & Lim, H. S. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13494 · Cited by 30
Elgendy, A. Y., Mahmoud, A. N., Khan, M. S., Sheikh, M. R., Mojadidi, M. K., Omer, M. A., Elgendy, I. Y., Bavry, A. A., Ellenbogen, K. A., Miles, W. M., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.05.009 · Cited by 31
Safety of Same Day Discharge after Atrial Fibrillation Ablation
Lakkireddy, D. (2020) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2150 · Cited by 30
Simon, J., Mahdiui, M. E., Smit, J. M., Száraz, L., van Rosendael, A. R., Herczeg, S., Zsarnóczay, E., Nagy, A. I., Kolossváry, M., Szilveszter, B., et al. (2021) · Clinical Cardiology · doi:10.1002/clc.23748 · Cited by 31
Kim, M., Lee, J. J., Kim, S.-A., Kim, Y. H., Choi, J., Park, S., Park, S. W., Kim, Y., & Shim, W. (2014) · International Heart Journal · doi:10.1536/ihj.13-370 · Cited by 31
Bordignon, S., Chun, K.-R. J., Gunawardene, M., Schulte‐Hahn, B., Nowak, B., Fuernkranz, A., & Schmidt, B. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.86 · Cited by 31
Metadata
- Authors
- Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., Skanes, A., Ambrogi, F., & Biganzoli, E.
- Affiliations
- The Royal Melbourne Hospital (AU)
- ORCID
- Venue
- Circulation Arrhythmia and Electrophysiology
- Published
- 2010-02
- Volume
- 3
- Issue
- 1
- Pages
- 32-38
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2146673314
- Cited by
- 2,852
- References
- 34
- Citations by year
- 2026: 26 · 2025: 42 · 2024: 51 · 2023: 68 · 2022: 81 · 2021: 110 · 2020: 126 · 2019: 125 · 2018: 141 · 2017: 177 · 2016: 199 · 2015: 184 · 2014: 220 · 2013: 246 · 2012: 218
- FWCI
- 156.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation Arrhythmia and Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- catheter ablation, atrial fibrillation, paroxysmal atrial fibrillation, persistent atrial fibrillation, ablation efficacy, ablation safety, procedural complications, CARTO system
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Anticoagulants, Atrial Fibrillation, Data Collection, Female, Humans, Male, Middle Aged, Surveys and Questionnaires, Treatment Outcome, Catheter Ablation, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review