Laminar Arrangement of Ventricular Myocytes Influences Electrical Behavior of the Heart
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The response of the heart to electrical shock, electrical propagation in sinus rhythm, and the spatiotemporal dynamics of ventricular fibrillation all depend critically on the electrical anisotropy of cardiac tissue. A long-held view of cardiac electrical anisotropy is that electrical conductivity is greatest along the myocyte axis allowing most rapid propagation of electrical activation in this direction, and that conductivity is isotropic transverse to the myocyte axis supporting a slower uniform spread of activation in this plane. In this context, knowledge of conductivity in two directions, parallel and transverse to the myofiber axis, is sufficient to characterize the electrical action of the heart. Here we present new experimental data that challenge this view. We have used a novel combination of intramural electrical mapping, and experiment-specific computer modeling, to demonstrate that left ventricular myocardium has unique bulk conductivities associated with three microstructurally-defined axes. We show that voltage fields induced by intramural current injection are influenced by not only myofiber direction, but also the transmural arrangement of muscle layers or myolaminae. Computer models of these experiments, in which measured 3D tissue structure was reconstructed in-silico, best matched recorded voltages with conductivities in the myofiber direction, and parallel and normal to myolaminae, set in the ratio 4:2:1, respectively. These findings redefine cardiac tissue as an electrically orthotropic substrate and enhance our understanding of how external shocks may act to successfully reset the fibrillating heart into a uniform electrical state. More generally, the mechanisms governing the destabilization of coordinated electrical propagation into ventricular arrhythmia need to be evaluated in the light of this discovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spatial and temporal organization during cardiac fibrillation
Gray, R. A., Pertsov, A. M., & Jalife, J. (1998) · Nature · doi:10.1038/32164 · Cited by 958
LeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.2.h571 · Cited by 842
Self-citationDirectional differences of impulse spread in trabecular muscle from mammalian heart.
Clerc, L. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011283 · Cited by 659 · cited 7×
“ented at any location (1) along myofibers, (2) transverse to”
BackgroundMethodInfluentialMathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657
Self-citationScollan, D. F., Holmes, A., Winslow, R., & Forder, J. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.6.h2308 · Cited by 457
Roberts, D. E., Hersh, L. T., & Scher, A. M. (1979) · Circulation Research · doi:10.1161/01.res.44.5.701 · Cited by 437 · cited 8×
“5 mm) in spatial registration of the tissue slices, (2) minor tissue distortions introduced during tissue transfer from cryostat blade to glass slide, (3) departures (typically 5°) from orthogonality of the section orientations, and (4) occasional nonlamina features (such as blood vessels) influencing the angle detect…”
BackgroundMethodInfluentialShear properties of passive ventricular myocardium
Dokos, S., Smaill, B. H., Young, A. A., & LeGrice, I. J. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00111.2002 · Cited by 373
Self-citationSpach, M. S., Miller, W. T., Miller-Jones, E., Warren, R. B., & Barr, R. C. (1979) · Circulation Research · doi:10.1161/01.res.45.2.188 · Cited by 302 · cited 1×
“5 mm) in spatial registration of the tissue slices, (2) minor tissue distortions introduced during tissue transfer from cryostat blade to glass slide, (3) departures (typically 5°) from orthogonality of the section orientations, and (4) occasional nonlamina features (such as blood vessels) influencing the angle detect…”
BackgroundThree-dimensional analysis of regional cardiac function: a model of rabbit ventricular anatomy
Vetter, F. J., & McCulloch, A. D. (1998) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(98)00006-6 · Cited by 255
Effect of tissue anisotropy on extracellular potential fields in canine myocardium in situ.
Roberts, D. E., & Scher, A. M. (1982) · Circulation Research · doi:10.1161/01.res.50.3.342 · Cited by 246 · cited 5×
“5 mm) in spatial registration of the tissue slices, (2) minor tissue distortions introduced during tissue transfer from cryostat blade to glass slide, (3) departures (typically 5°) from orthogonality of the section orientations, and (4) occasional nonlamina features (such as blood vessels) influencing the angle detect…”
BackgroundMethodInfluential
Cited by
Bayer, J. D., Blake, R. C., Plank, G., & Trayanova, N. A. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0593-5 · Cited by 557
Arevalo, H. J., Vadakkumpadan, F., Guallar, E., Jebb, A., Malamas, P., Wu, K. C., & Trayanova, N. A. (2016) · Nature Communications · doi:10.1038/ncomms11437 · Cited by 465
Physiological Implications of Myocardial Scar Structure
Richardson, W. J., Clarke, S. A., Quinn, T. A., & Holmes, J. W. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140067 · Cited by 268
Three-dimensional transmural organization of perimysial collagen in the heart
Pope, A. J., Sands, G. B., Smaill, B. H., & LeGrice, I. J. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00484.2008 · Cited by 205
“It has been demonstrated experimentally that the left ventricular (LV) myocardium has significantly different bulk electrical conductivities associated with both fiber and laminar orientation (20).”
BackgroundSelf-citationBishop, M. J., Plank, G., Burton, R. A. B., Schneider, J. E., Gavaghan, D. J., Grau, V., & Kohl, P. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00606.2009 · Cited by 171
Mapping Myocardial Fiber Orientation Using Echocardiography-Based Shear Wave Imaging
Lee, W.-N., Pernot, M., Couade, M., Messas, E., Bruneval, P., Bel, A., Hagege, A. A., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2172690 · Cited by 171
“This transmural structural variation is highly associated with myocardial deformation [3]–[5], mechanical properties, and electrical activation [6]–[9].”
BackgroundPlank, G., Burton, R. A. B., Hales, P., Bishop, M., Mansoori, T., Bernabeu, M. O., Garny, A., Prassl, A. J., Bollensdorff, C., Mason, F., et al. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0056 · Cited by 158
“with z being one of three possible eigendirections of the conductivity tensor (Hooks et al. 2007).”
InfluentialCarruth, E. D., McCulloch, A. D., & Omens, J. H. (2016) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2016.11.004 · Cited by 38
“timing of contraction is also affected by sheet structures (Hooks et al., 2007), which in turn also affects regional stresses and strains (Krishnamurthy et al.”
BackgroundAssessing Myocardial Architecture: The Challenges and Controversies
Agger, P., & Stephenson, R. S. (2020) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd7040047 · Cited by 11
“Evidence also suggests that the organisation into structural subunits determines the properties of electric conduction through the myocardium [90,91].”
Background
Metadata
- Authors
- Hooks, D. A., Trew, M. L., Caldwell, B. J., Sands, G. B., LeGrice, I. J., & Smaill, B. H.
- Venue
- Circulation Research
- Published
- 2007-11-09
- Volume
- 101
- Issue
- 10
- Pages
- e103-12
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2143421921
- Cited by
- 187
- References
- 38
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.