CoChat
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Fluorescence Tomography and Magnetic Resonance Imaging of Myocardial Macrophage Infiltration in Infarcted Myocardium In Vivo

Open access
Sosnovik, David E., Nahrendorf, Matthias, Deliolanis, Nikolaos, Novikov, Mikhail, Aikawa, Elena, Josephson, Lee, Rosenzweig, Anthony, Weissleder, Ralph, Ntziachristos, Vasilis · 2007 · Circulation

Abstract

Background— Fluorescence imaging of the heart is currently limited to invasive ex vivo or in vitro applications. We hypothesized that the adaptation of advanced transillumination and tomographic techniques would allow noninvasive fluorescence images of the heart to be acquired in vivo and be coregistered with in vivo cardiac magnetic resonance images. Methods and Results— The uptake of the magnetofluorescent nanoparticle CLIO-Cy5.5 by macrophages in infarcted myocardium was studied. Ligation of the left coronary artery was performed in 12 mice and sham surgery in 7. The mice were injected, 48 hours after surgery, with 3 to 20 mg of iron per kilogram of CLIO-Cy5.5. Magnetic resonance imaging and fluorescence molecular tomography were performed 48 hours later. An increase in magnetic resonance imaging contrast-to-noise ratio, indicative of myocardial probe accumulation, was seen in the anterolateral walls of the infarcted mice but not in the sham-operated mice (23.0±2.7 versus 5.43±2.4; P <0.01). Fluorescence intensity over the heart was also significantly greater in the fluorescence molecular tomography images of the infarcted mice (19.1±5.2 versus 5.3±1.4; P <0.05). The uptake of CLIO-Cy5.5 by macrophages infiltrating the infarcted myocardium was confirmed by fluorescence microscopy and immunohistochemistry. Conclusions— Noninvasive imaging of myocardial macrophage infiltration has been shown to be possible by both fluorescence tomography and magnetic resonance imaging. This could be of significant value in both the research and clinical settings. The techniques developed could also be used to image other existing fluorescent and magnetofluorescent probes and could significantly expand the role of fluorescence imaging in the heart.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.663351

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Sosnovik, D. E., Nahrendorf, M., Deliolanis, N., Novikov, M., Aikawa, E., Josephson, L., Rosenzweig, A., Weissleder, R., & Ntziachristos, V.
Venue
Circulation
Published
2007-03-20
Volume
115
Issue
11
Pages
1384-1391
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2006439362
Cited by
195
References
1
FWCI
12.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.