The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Catheter Ablation for the Treatment of Electrical Storm in Patients With Implantable Cardioverter-Defibrillators: Short- and Long-Term Outcomes in a Prospective Single-Center Study
Open accessAbstract
Background— Electrical storm (ES) caused by recurrent episodes of ventricular tachycardia (VT) can cause sudden death in patients with implantable cardioverter-defibrillators and adversely affects prognosis in survivors. Catheter ablation has been proposed for treating ES, but its long-term effect in a large population has never been verified. Methods and Results— Ninety-five consecutive patients with coronary artery disease (72 patients), idiopathic dilated cardiomyopathy (10 patients), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (13 patients) undergoing catheter ablation for drug-refractory ES were prospectively evaluated. Short-term efficacy was defined by a complete protocol of programmed electric stimulation and by in-hospital outcome; long-term analysis addressed ES recurrence, cardiac mortality, and VT recurrence. Pleomorphic/nontolerated VTs required electroanatomic and noncontact mapping in 48 and 22 patients, respectively, and percutaneous cardiopulmonary support in 10 patients. An epicardial approach was used in 10 patients. After 1 to 3 procedures, induction of any clinical VT(s) by programmed electrical stimulation was prevented in 85 patients (89%). ES was acutely suppressed in all patients; a minimum period of 7 days with stable rhythm was required before hospital discharge. At a median follow-up of 22 months (range, 1 to 43 months), 87 patients (92%) were free of ES and 63 patients (66%) were free of VT recurrence. Eight of 10 patients with persistent inducibility of clinical VT(s) had ES recurrence; 4 of them died suddenly despite appropriate implantable cardioverter-defibrillator intervention. All together, 11 of 95 patients (12%) died of cardiac-related reasons. In the group of patients presenting with all clinical VTs acutely abolished, no ES recurrence was documented, and cardiac mortality was significantly lower compared with the group of patients showing ≥1 clinical VT still inducible after catheter ablation. Conclusions— Advanced strategies of catheter ablation applied to a large population of patients are effective in the short-term treatment of ES. By preventing ES recurrence, catheter ablation may play a protective role over the long term and, together with long-term pharmacological therapy, may favorably affect cardiac mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E. (2000) · Circulation · doi:10.1161/01.cir.101.11.1288 · Cited by 1,220
A New Technique to Perform Epicardial Mapping in the Electrophysiology Laboratory
SOSA, E., SCANAVACCA, M., D'AVILA, A., & PILLEGGI, E. (1996) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1996.tb00559.x · Cited by 876
Gepstein, L., Hayam, G., & Ben-Haim, S. A. (1997) · Circulation · doi:10.1161/01.cir.95.6.1611 · Cited by 759
Writing Committee Members, Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., et al. (2006) · Europace · doi:10.1093/europace/eul108 · Cited by 738
Soejima, K., Stevenson, W. G., Sapp, J. L., Selwyn, A. P., Couper, G., & Epstein, L. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.029 · Cited by 485
Soejima, K., Suzuki, M., Maisel, W. H., Brunckhorst, C. B., Delacretaz, E., Blier, L., Tung, S., Khan, H., & Stevenson, W. G. (2001) · Circulation · doi:10.1161/hc3101.093764 · Cited by 409
Exner, D. V., Pinski, S. L., Wyse, D. G., Renfroe, E. G., Follmann, D., Gold, M., Beckman, K. J., Coromilas, J., Lancaster, S., & Hallstrom, A. P. (2001) · Circulation · doi:10.1161/01.cir.103.16.2066 · Cited by 396
Electrical storm in patients with transvenous implantable cardioverter-defibrillators
Credner, S. C., Klingenheben, T., Mauss, O., Sticherling, C., & Hohnloser, S. H. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00495-1 · Cited by 376
Successful Catheter Ablation of Electrical Storm After Myocardial Infarction
Bänsch, D., Oyang, F., Antz, M., Arentz, T., Weber, R., Val-Mejias, J. E., Ernst, S., & Kuck, K.-H. (2003) · Circulation · doi:10.1161/01.cir.0000103701.30662.5c · Cited by 307
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citationESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2008
Dickstein, K., Authors/Task Force Members, Cohen-Solal, A., Filippatos, G., McMurray, J. J. V., Ponikowski, P., Poole-Wilson, P. A., Strömberg, A., van Veldhuisen, D. J., Atar, D., et al. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.08.005 · Cited by 3,512
Self-citationZeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Authors/Task Force Members, Dickstein, K., Cohen-Solal, A., Filippatos, G., McMurray, J. J. V., Ponikowski, P., Poole-Wilson, P. A., Stromberg, A., van Veldhuisen, D. J., Atar, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn309 · Cited by 2,696
Self-citation(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Kuck, K.-H., Schaumann, A., Eckardt, L., Willems, S., Ventura, R., Delacrétaz, E., Pitschner, H.-F., Kautzner, J., Schumacher, B., & Hansen, P. S. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61755-4 · Cited by 799
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Tsutsui, H., Isobe, M., Ito, H., Ito, H., Okumura, K., Ono, M., Kitakaze, M., Kinugawa, K., Kihara, Y., Goto, Y., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0342 · Cited by 704
Tung, R., Vaseghi, M., Frankel, D. S., Vergara, P., Di Biase, L., Nagashima, K., Yu, R., Vangala, S., Tseng, C.-H., Choi, E.-K., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.036 · Cited by 499
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationDi Biase, L., Santangeli, P., Burkhardt, D. J., Bai, R., Mohanty, P., Carbucicchio, C., Dello Russo, A., Casella, M., Mohanty, S., Pump, A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.044 · Cited by 422
Self-citationAliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Dinov, B., Fiedler, L., Schönbauer, R., Bollmann, A., Rolf, S., Piorkowski, C., Hindricks, G., & Arya, A. (2014) · Circulation · doi:10.1161/circulationaha.113.003063 · Cited by 390
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Self-citationHernández-Madrid, A., Paul, T., Abrams, D., Aziz, P. F., Blom, N. A., Chen, J., Chessa, M., Combes, N., Dagres, N., Diller, G., et al. (2018) · EP Europace · doi:10.1093/europace/eux380 · Cited by 317
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.024 · Cited by 288
Ventricular arrhythmias and sudden cardiac death
John, R. M., Tedrow, U. B., Koplan, B. A., Albert, C. M., Epstein, L. M., Sweeney, M. O., Miller, A. L., Michaud, G. F., & Stevenson, W. G. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61413-5 · Cited by 286
Droogan, C., Patel, C., Yan, G.-X., & Kowey, P. R. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.003 · Cited by 10
Metadata
- Authors
- Carbucicchio, C., Santamaria, M., Trevisi, N., Maccabelli, G., Giraldi, F., Fassini, G., Riva, S., Moltrasio, M., Cireddu, M., Veglia, F., & Della Bella, P.
- Venue
- Circulation
- Published
- 2008-01-29
- Volume
- 117
- Issue
- 4
- Pages
- 462-469
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1998487877
- Cited by
- 460
- References
- 32
- FWCI
- 21.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.