Stroke Risk as a Function of Atrial Fibrillation Duration and CHA 2 DS 2 -VASc Score
Open accessAbstract
Background: Studies of patients with cardiovascular implantable electronic devices show a relationship between atrial fibrillation (AF) duration and stroke risk, although the interaction with CHA 2 DS 2 -VASc score is poorly defined. The objective of this study is to evaluate rates of stroke and systemic embolism (SSE) in patients with cardiovascular implantable electronic devices as a function of both CHA 2 DS 2 -VASc score and AF duration. Methods: Data from the Optum electronic health record deidentified database (2007–2017) were linked to the Medtronic CareLink database of cardiovascular implantable electronic devices capable of continuous AF monitoring. An index date was assigned as the later of either 6 months after device implantation or 1 year after electronic health record data availability. CHA 2 DS 2 -VASc score was assessed using electronic health record data before the index date. Maximum daily AF burden (no AF, 6 minutes–23.5 hours, and >23.5 hours) was assessed over the 6 months before the index date. SSE rates were computed after the index date. Results: Among 21 768 nonanticoagulated patients with cardiovascular implantable electronic devices (age, 68.6±12.7 years; 63% male), both increasing AF duration ( P <0.001) and increasing CHA 2 DS 2 -VASc score ( P <0.001) were significantly associated with annualized risk of SSE. SSE rates were low in patients with a CHA 2 DS 2 -VASc score of 0 to 1 regardless of device-detected AF duration. However, stroke risk crossed an actionable threshold defined as >1%/y in patients with a CHA 2 DS 2 -VASc score of 2 with >23.5 hours of AF, those with a CHA 2 DS 2 -VASc score of 3 to 4 with >6 minutes of AF, and patients with a CHA 2 DS 2 -VASc score ≥5 even with no AF. Conclusions: There is an interaction between AF duration and CHA 2 DS 2 -VASc score that can further risk-stratify patients with AF for SSE and may be useful in guiding anticoagulation therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000665 · Cited by 2,744
Miyasaka, Y., Barnes, M. E., Gersh, B. J., Cha, S. S., Bailey, K. R., Abhayaratna, W. P., Seward, J. B., & Tsang, T. S. M. (2006) · Circulation · doi:10.1161/circulationaha.105.595140 · Cited by 2,564
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879 · cited 1×
“Stroke/transient ischemic attack 2994 (14) 1838 (29)”
Self-citationGlotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT
Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx042 · Cited by 599
Turakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2018.09.002 · Cited by 474
Smartwatch Algorithm for Automated Detection of Atrial Fibrillation
Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.003 · Cited by 446
Validity of diagnostic codes for acute stroke in administrative databases: a systematic review.
McCormick, N., Bhole, V., Lacaille, D., & Avina-Zubieta, J. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135834 · Cited by 414
Goldstein, L. B. (1998) · Stroke · doi:10.1161/01.str.29.8.1602 · Cited by 408
Capucci, A., Santini, M., Padeletti, L., Gulizia, M., Botto, G., Boriani, G., Ricci, R., Favale, S., Zolezzi, F., Di Belardino, N., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 401
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Lopes, R. D., Alings, M., Connolly, S. J., Beresh, H., Granger, C. B., Mazuecos, J. B., Boriani, G., Nielsen, J. C., Conen, D., Hohnloser, S. H., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.04.008 · Cited by 290
Go, A. S., Reynolds, K., Yang, J., Gupta, N., Lenane, J., Sung, S. H., Harrison, T. N., Liu, T. I., & Solomon, M. D. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1176 · Cited by 286
Moving the Tipping Point: The Decision to Anticoagulate Patients With Atrial Fibrillation
Eckman, M. H., Singer, D. E., Rosand, J., & Greenberg, S. M. (2011) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.958108 · Cited by 275
Kirchhof, P., Blank, B. F., Calvert, M., Camm, A. J., Chlouverakis, G., Diener, H.-C., Goette, A., Huening, A., Lip, G. Y. H., Simantirakis, E., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.04.015 · Cited by 227
Turakhia, M. P., Ziegler, P. D., Schmitt, S. K., Chang, Y., Fan, J., Than, C. T., Keung, E. K., & Singer, D. E. (2015) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.114.003057 · Cited by 197
Self-citationSwiryn, S., Orlov, M. V., Benditt, D. G., Dimarco, J., Lloyd‐Jones, D. M., Karst, E., Qu, F., Slawsky, M., Turkel, M., & Waldo, A. L. (2016) · Circulation · doi:10.1161/circulationaha.115.020252 · Cited by 173
Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies
PURERFELLNER, H., GILLIS, A. M., HOLBROOK, R., & HETTRICK, D. A. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00569.x · Cited by 162
Perino, A. C., Fan, J., Askari, M., Heidenreich, P. A., Keung, E. C., Raitt, M. H., Piccini, J. P., Ziegler, P., & Turakhia, M. P. (2019) · Circulation · doi:10.1161/circulationaha.118.038988 · Cited by 107
Self-citationAccuracy of Mode Switch Algorithms for Detection of Atrial Tachyarrhythmias
PASSMAN, R. S., Weinberg, K. M., Freher, M., Schaechter, A., Goldberger, J. J., & Kadish, A. H. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03537.x · Cited by 101
Self-citationCharitos, E. I., Ziegler, P., Stierle, U., Robinson, D., GRAF, B., Sievers, H., & Hanke, T. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12389 · Cited by 46
Self-citationOvervad, T. F., Nielsen, P. B., & Lip, G. Y. H. (2016) · European Heart Journal - Cardiovascular Pharmacotherapy · doi:10.1093/ehjcvp/pvw022 · Cited by 37
Kaplan, R. M., Ziegler, P., Koehler, J. L., Glotzer, T. V., & PASSMAN, R. S. (2017) · Clinical Cardiology · doi:10.1002/clc.22766 · Cited by 3
Self-citation
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Metadata
- Authors
- Kaplan, R. M., Koehler, J., Ziegler, P. D., Sarkar, S., Zweibel, S., & Passman, R. S.
- Venue
- Circulation
- Published
- 2019-11-12
- Volume
- 140
- Issue
- 20
- Pages
- 1639-1646
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2979231018
- Cited by
- 284
- References
- 26
- FWCI
- 20.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.